• 제목/요약/키워드: Fire escape

검색결과 233건 처리시간 0.024초

고층건축물의 피난경로 가압제연시스템 성능개선대책에 관한 연구 (A Study on Performance Improvement Measures of Pressurized Smoke Control Systems for Exit Passageways of High-Rise Buildings)

  • 손봉세;김진수
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.703-714
    • /
    • 2009
  • One of the biggest problems in smoke control systems for high-rise buildings is stack effect, but there are no recognized methods or measures to solve the problem of stack effect as yet. The stack effect can be overcome by forming the uprising current inside the stair hall properly, but there is a limit to the height in supplying into the stair hall the smoke control air volume to be supplied to a floor in case of escape from fire. The limit to the height can be extended by over-coming the stack effect by pressurizing the stair hall and the ancillary room simultaneously. It can also be anticipated that the stack effect can be overcome by connecting the air supply shaft to the stair hall at the top. As a result of computer simulations using a network type of tool, it is found that adequate performance can be achieved by pressurizing the stair hall only for a building of 190m or less, and up to 360m when pressurizing the stair hall and the ancillary room simultaneously. In all those cases, however, an overpressure venting damper is required which operates within a suitable range for venting the overpressure outside.

자동차압·과압조절형댐퍼의 개폐동작횟수 증가에 따른 누설량 실험 연구 (The Experimental Study on the Leakage of Automatic Pressure Differential·Overpressure Control Dampers by Increasing the Number of Damper Operation)

  • 신평식;김학중
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.56-61
    • /
    • 2016
  • 최근 건축물은 대형화, 고층화되어 화재발생시 소방대의 활동이 제한되어 화염 및 연기에 의한 인명피해가 증가할 수 있다. 이러한 인명피해를 저감하기 위하여 제연설비가 필수적이며 특별피난계단 부속실 및 비상용승강기 승강장에 급기가압제연설비를 적용하고 있다. 국가 화재안전기준에서는 부속실 및 승강장과 거실과의 차압을 40 Pa 이상 요구하고 있으나 실제 현장에서는 과도한 과압이 다수 발생하고 있다. 이러한 과압의 원인은 댐퍼의 누설량의 과다에 의한 것으로 알려져 있다. 과압은 피난자의 문개방을 어렵게 하여 피난을 불가능하게 할 수 있다. 이러한 문제점을 확인하고자 자동차압 과압조절형댐퍼의 개폐 동작횟수 증가에 따른 누설량을 측정하여 초기에 공급된 댐퍼의 누설량과 비교 분석하였다. 실험결과 초기 제품과 반복동작 후 누설량의 차이가 발생했으며 정압이 증가함에 따라 누설량 차이가 증가되었다. 선행연구와 비교분석한 결과도 정압에 따른 선형적 증가의 경향이 유사한 추세를 보이고 있다.

FDS를 이용한 특별피난계단 부속실 제연설비의 방연풍속 기류특성 (Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator)

  • 류성호;이수경;홍대화;최금란
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.153-159
    • /
    • 2010
  • 본 연구는 국내 고층건물 특별피난계단 부속실에 급기가압 제연시스템이 설치되어 있음에도 불구하고 화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 형성되는 방연풍속의 기류가 거실 방향으로 정상적으로 형성되지 않고 부속실로 역류되는 사실을 설치 현장의 실측과 CFD기반 시뮬레이션을 통하여 확인하였다. 그 내용을 보면 방연풍속의 기류 특성은 부속실의 면적이 작을 경우 심하게 출입문 상부로 기류가 역류되었다. 시뮬레이션 결과 급기댐퍼의 날개각도가 45도 상향인 경우는 출입문 하단부에 일부 역기류 현상이 발생하였지만 상단부에서는 기류분포가 양호하였다. 부속실 면적이 $4m^2$인 경우는 출입문에서 거실방향으로 정상적인 기류 분포를 보였다. 이러한 상황에서 부속실 면적이 작게 설계될 경우 성능위주 설계를 실시하여야 한다.

부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 2개 출입문이 존재할 경우 균일한 방연풍속을 얻기 위한 댐퍼 위치 선정방법 (Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Damper Locationfor Uniform Air Egress Velocity in the case of Two Fire Doors)

  • 서찬원;신원규
    • 한국화재소방학회논문지
    • /
    • 제28권6호
    • /
    • pp.1-7
    • /
    • 2014
  • 부속실 가압시스템의 가장 중요한 역할은 건축물 내부에 화재가 발생 시 피난을 위하여 방화문이 개방 될 경우 균일한 방연풍속을 형성하여 연기의 침입을 방지하는 것이다. 이러한 설비의 성능확보를 위하여 균일한 방연풍속이 형성될 수 있도록 공기 공급 유니트를 배치하는 것이 중요하다. 본 연구에서는 대형건물에 설치되는 2개의 출입문을 갖는 부속실의 경우, 방연풍속이 균일하게 형성될 수 있는지 수치해석을 수행하였고, 나타난 문제점을 해결하기 위한 주요변수로 댐퍼의 위치 및 루버의 각도를 선정하고, 두 변수를 조정하여 균일한 방연풍속을 얻을 수 있는 해결책을 찾아보았다. 그 결과, 부속실의 댐퍼 위치의 중요성을 확인하였으며, 2개의 방화문이 존재할 경우 출입문 맞은편 중간 벽에 배치할 경우 성능에 있어서 좋은 결과를 얻을 수 있었다.

자동차압 · 과압조절형댐퍼의 누설량 실험 연구 (The Experimental Study on the Leakage of Automatic Pressure Differential · Overpressure Control Dampers)

  • 신평식;김학중
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.71-75
    • /
    • 2015
  • 최근 건축물은 대형화, 고층화되어 화재발생시 소방대의 활동이 제한되어 화염 및 연기에 의한 인명피해가 증가할 수 있다. 이러한 인명피해를 저감하기 위하여 제연설비가 필수적이며 특별피난계단 부속실 및 비상용승강기 승강장에 급기 가압제연설비를 적용하고 있다. 국가 화재안전기준에서는 부속실 및 승강장과 거실과의 차압을 40 Pa~60 Pa을 요구하고 있으나 실제 현장에서는 60 Pa 이상의 과압이 다수 발생하고 있다. 이러한 과압의 원인은 댐퍼의 누설량의 과다에 의한 것으로 알려져 있다. 과압은 피난자의 문개방을 어렵게 하여 피난을 불가능하게 할 수 있다. 이러한 문제점을 확인하고자 국내에 사용되고 있는 자동차압 과압조절형댐퍼의 누설량을 측정하여 실제 누설량이 얼마인지 분석하였다. 실험결과 제조사 별로 최대 누설량은 $0.154m^3/s$로 나타났으며, 최소 누설량은 $0.090m^3/s$로 나타났다. 이 누설량으로 인하여 과압이 발생하면 피난문 폐쇄력이 증가하여 피난에 방해가 될 수 있으므로 댐퍼의 누설량 제한 기준이 필요하다.

Environment Adaptive Emergency Evacuation Route GUIDE through Digital Signage Systems

  • Lee, Dongwoo;Kim, Daehyun;Lee, Junghoon;Lee, Seungyoun;Hwang, Hyunsuk;Mariappan, Vinayagam;Lee, Minwoo;Cha, Jaesang
    • International Journal of Advanced Culture Technology
    • /
    • 제5권1호
    • /
    • pp.90-97
    • /
    • 2017
  • Nowadays, the most of commercial buildings are build-out with complex architecture and decorated with more complicated interiors of buildings so establishing intelligible escape routes becomes an important case of fire or other emergency in a limited time. The commercial buildings are already equipped with multiple exit signs and these exit signs may create confusion and leads the people into different directions under emergency. This can jeopardize the emergency situation into a chaotic state, especially in a complex layout buildings. There are many research focused on implementing different approached to improve the exit sign system with better visual navigating effects, such as the use of laser beams, the combination of audio and video cues, etc. However the digital signage system based emergency exit sign management is one of the best solution to guide people under emergency situations to escape. This research paper, propose an intelligent evacuation route GUIDE that uses the combination centralized Wireless Sensor Networks (WSN) and digital signage for people safety and avoids dangers from emergency conditions. This proposed system applies WSN to detect the environment condition in the building and uses an evacuation algorithm to estimate the safe route to escape using the sensor information and then activates the signage system to display the safe evacuation route instruction GUIDE according to the location the signage system is installed. This paper presented the prototype of the proposed signage system and execution time to find the route with future research directions. The proposed system provides a natural intelligent evacuation route interface for self or remote operation in facility management to efficiently GUIDE people to the safe exit under emergency conditions.

터널 내부 기류 변화에 따른 피난연락갱 간격 설정에 관한 연구 (A study on an interval of tunnel cross passage considering inclination and internal airflow)

  • 이동호;김하영;유지오
    • 한국터널지하공간학회 논문집
    • /
    • 제12권1호
    • /
    • pp.43-49
    • /
    • 2010
  • 도로터널내의 피난연락갱은 화재시 터널내 통행자의 안전성 확보를 위한 방재시설 중 하나이며 국내의 경우 500 m이상 터널에서는 250 m 간격 이하로 설치하도록 규정하고 있다. 그러나 이러한 일괄적인 피난연락갱 간격 산정은 터널내 풍속이나 구배, 화재강도 및 터널의 내공단면적 등 터널의 특성에 대한 고려가 되지 않기 때문에 과대 및 과소 설비가 될 우려가 발생한다. 본 연구에서는 터널 내 풍속 및 구배의 영향을 고려한 피난연락갱 적정간격 산정 방식을 제시하여 터널 설계시 피난연락갱의 효율적인 적용을 목표로 한다. 결과로 터널내 풍속이 0 m/s와 1.0 m/s의 경우 구배에 의한 영향이 뚜렷한 것으로 분석되었으나 2.0 m/s 이상의 경우 터널내 구배에 의한 연기의 이동은 큰 영향을 미치지 못하는 것으로 나타났다. 터널 내부 기류속도 및 터널 구배에 따른 적정 피난연락갱 간격이 상이하게 나타나 250 m 간격인 기존의 일괄적인 피난연락갱 간격 산정이 아닌 터널 내 풍속이나 구배, 화재강도 및 터널의 내공단면적 등 터널의 특성에 대한 고려값을 적용한 적정 피난연락갱 산정이 필요하다.

선박 구조 개선을 통한 승무원의 피난 효율 향상을 위한 연구 (A study on the efficiency advancement for evacuation of the crews by ship structural improvement)

  • 김원욱;이명호;김종수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.342-348
    • /
    • 2014
  • 육상구조물의 대형화재는 특수한 소방장비와 그에 적합한 방법에 의해서 소방관에 의해서 진압된다. 하지만 해양구조물은 육상으로부터 어떠한 도움없이 승무원에 의해서 진압되고 이들은 선박의 구조적 특성과 선박의 충돌 및 화재와 같은 여러 가지 원인에 의하여 신속한 탈출이 어렵다. 일반적으로 화재에 의한 인명손상의 경우에는 연기에 의한 질식사가 대부분을 차지하므로 탈출 시간의 단축은 생존율을 향상에 아주 중요한 역할을 한다. 본 연구에서는 3차원 화재 분석 전용 프로그램인 FDS(Fire Dynamic Simulator)를 이용하여 화재 발생 시 승무원 생존율 분석을 위한 거주 공간내의 온도 및 연기유동에 의한 가시거리를 분석한다. 기존의 선박은 화재 경보 발령 시 방화문이 자동으로 폐쇄되도록 설계되어 있다. 이는 화재가 발생한 구역에 승무원이 없을 경우에는 화재의 확산 및 연기의 유동 지연에 아주 효과적이다. 그러나 대피시간이 지연될 경우에는 방화문 안쪽에 위치한 승무원들에게는 치명적일 수 있다. 이 논문에서는 화재로 인해 방화문이 폐쇄되어 승무원들이 이 방화문을 열고 탈출하는 경우와 연구에서 제안하는 차단막을 설치했을 경우의 화재 구역의 온도상승 및 연기유동 속도를 비교 분석한다.

Delphi/AHP를 활용한 다중이용업 신종업종의 화재위험평가지표 분석 (Analysis of Fire Risk Assessment Indicators of Publicly-Used Establishments using Delphi/AHP)

  • 김명철;김학중;박경환;윤해권;이승호
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.87-94
    • /
    • 2019
  • 국민권익위원회 2018년 7월 17일 보도 자료에 의하면 방탈출카페, 실내양궁장 등 신종업종이 다중이용업에서 제외되어 지정을 검토하고 화재예방 대책을 수립하도록 소방청에 권고하였다. 본 연구는 Delphi 기법으로 다중이용업 신종업종의 화재위험평가 측정영역 및 측정지표를 계층화하고 적합도(3.00 이상) 분석결과, 적합도 평균값이 4.25로서 적합성을 확보하였다. AHP 분석결과, 화재위험평가 측정영역의 일관성 비율은 4.0%로서 CR ≤ 0.1(10%) 보다 낮게 분석되었고 하위 측정지표의 일관성 비율도 0.1%~3.6%로서 모두 일관성이 있음을 확인하였다. 통합 측정지표의 중요도와 우선순위는 영업장 내부통로의 형태 및 출구의 피난능력(0.316), 점화원관리(0.141), 고유위험(0.106), 화재감지시스템의 적절성 및 적응성(0.097), 가연물관리(0.084), 피난안내 및 피난설비(0.075), 내화구조 및 마감재료(0.060), 구획 및 비상구(0.049), 연소확대위험(0.046), 소화설비의 적절성 및 적응성(0.026)의 순으로 도출 되었다. 본 연구는 향후, 화재위험평가지표 개발 연구의 중요한 자료로 널리 활용 될 것이다.

화재 출동시간에 근거한 진주시 소방권역 분석 (An Analysis of Fire Area in Jinju City Based on Fire Mobilization Time)

  • 구슬;유환희
    • 대한공간정보학회지
    • /
    • 제20권4호
    • /
    • pp.127-134
    • /
    • 2012
  • 본 연구에서는 진주시지역의 소방서(5개 119안전센터, 1개 119지역대)를 대상으로 GIS의 네트워크 분석을 이용하여 진주시에 위치한 소방서의 화재진압출동시간별 서비스현황을 분석하였다. 그 결과 진주시 전체 소방서비스면적 중 출동시간 5분 이내 비율은 15.9%, 8분 이내 비율 34.7%, 20분 이내 비율 94%로 나타났으며, 20분 이상인 지역도 6%에 이른 것으로 분석되었다. 특히, 시외곽지역(진성, 지수, 사봉, 일반성, 이반성면 일대)의 소방서비스 접근 취약성을 해결하기 위하여 일반성면에 119지역대가 증설되어 운영되고 있지만 접근성은 여전히 낮은 수준에 머무르고 있다. 또한 천전 119안전센터의 경우 국가산업단지와 일반산업단지가 대규모로 조성되고 있으나 해당 지역의 소방서비스 수준을 분석해 보면 도달시간이 8분 이상 20분 이내지역이 넓게 존재하고 있었다. 이상의 진주시 소방서비스권역을 화재진압출동시간으로 분석한 결과 지방중소도시에서 도농통합에 의해 행정구역이 통합되어 관할지역이 크게 확장된 것에 비하여 소방서비스수준은 도농통합이전의 상태를 크게 벗어나지 못하고 있어서 이에 대한 개선대책이 필요하다.