• Title/Summary/Keyword: Fire curtain

Search Result 63, Processing Time 0.024 seconds

Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain (에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

The Transfer Characteristics of $CO_2$ Extinguishant According with the Location of Fire Plume (화재위치에 따른 $CO_2$소화제 전달특성)

  • 박찬수;최주석
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2003
  • To analyze the transfer characteristics of $CO_2$ extinguishant when extinguishant is injected into a closed space similar to a marine engine room, a numerical simulation was performed. Flow and Concentration fields are calculated according with the variation of the fire plume,s location. The results show that tile variation of fire plumes, location greatly effected on the flow patterns and the characteristics of $CO_2$ extinguishant transfer. In case of the fire plume located at left region of the 2nd floor center in the engine room consisted of first and second floor, The effects similar to the air curtain is found and cut off the mass transfer. In the characteristics with hight, the iso-concentration line below the extinguishable limit is formed in the left region of the 1st and 2nd floor center after the $CO_2$ extinguishant is completely injected. therefore I think that the results of this study are considered to arrange the $CO_2$ injection nozzles for the $CO_2$ fire fighting equipments.

A Study on Design Method of Blast Hardened Bulkhead Considering the Response of Shock Impulse (충격량에 대한 응답을 고려한 폭발강화격벽 설계 방법 연구)

  • Myojung Kwak;Joonyoung Yoon;Seungmin Kwon;Yoojeong Noh
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.1
    • /
    • pp.10-19
    • /
    • 2023
  • Blast Hardened Bulkhead (BHB) is an important measure that can increase the ship's survivability as well as protect the lives of the crew by mitigating the damage extent caused by an internal explosion in the ship. In particular, both the pressure and the shock impulse should be considered when designing the BHB against reflected shock waves having a high pressure with a short duration. This study proposes a design method for BHB that considers both the pressure and the shock impulse generated during the internal explosion. In addition, analysis and design concepts for accident loads such as explosion, fire, and collision of NORSOK and DNVGL, one of the international design guidelines for the curtain plate type blast hardened bulkhead type applied by the Korean Navy, are utilized. If this method is applied, it is expected that it can be used as a design concept for the pressure as well as the shock impulse of the explosion load of the curtain plate.

An Experimental Study on the Optimum Design Conditions of Curtain-wall Flame in Fire (화재시 커튼월 프레임 최적설계조건 도출을 위한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Jung-Hyun;Kim, Heoung-Youl;Lee, Jae-Sung;Lim, Hyun-Chang
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.351-356
    • /
    • 2011
  • 본 연구에서는 국외 커튼월 내화 Code인 EN 13830, EN 13501-1, EN 1364-3을 사용하여 알루미늄과 스틸프레임에 대해 화재시 최적설계조건 도출을 위한 실험을 실시하였다. 현재 국내 커튼월의 내화 법규는 2008년 '내화 충전구조 세부 운영지침'에서 조인트 부분에 대해서만 내화규정이 정립되어 있다. 따라서 본 연구에서는 EN 13830과 그 하위법을 이용하여 알루미늄과 스틸 커튼월의 최적설계조건 도출을 위한 실험을 실시하였다. 실험 결과 차염성은 알루미늄 커튼월과 스틸 커튼월의 성능시간이 각각 10분 26분으로 약 16분의 차이가 발생하였고, 차열성은 알루미늄 커튼월과 스틸 커튼월이 최고온도에서 6분과 9분으로 약 3분정도의 차이를 보였고 평균온도에서는 9분, 24분으로 약 15분의 차이를 보였다. 그리고 복사열은 성능기준 $15Kw/m^2$를 통과하는데 알루미늄 커튼월은 16분 스틸 커튼월은 24분을 기록하였다.

  • PDF

Numerical analysis on effect of hole size on Emergency Evacuation Support System (수치해석을 통한 비상피난지원 시스템의 급기구 크기에 따른 유동분석)

  • Kim, Ji Tae;Park, Won Hee;Lee, Duck Hee;Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.324-329
    • /
    • 2020
  • The emergency evacuation support system provides a safe means of evacuation by preventing the inflow of smoke through the formation of a smoke shield curtain in fire situations and pressurizing fresh air to the inside of the smoke shield curtain. In this study, numerical analysis was performed to examine the effects of the hole size on the flow inside the smoke curtain. As the air supply size decreased, the flow rate through the air supply was formed relatively uniformly from the inlet to the outlet length of the emergency support system. In addition, the size of the air supply hole was more than 20 mm, the flow rate was very low near the outlet, so the air supply hole size should be smaller than 20 mm. In addition, the minor loss of the air supply hole was calculated to be K = 1.5 from the numerical results. Therefore, the proper design of an emergency evacuation support system is possible using the flow characteristics according to the size and minor loss of the air supply hole.

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

Study on the Limiting Oxygen Index of Curtain Exposed to High Temperature (고온에 노출된 커튼의 한계산소지수에 관한 연구)

  • Kim, Hwang-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.1-5
    • /
    • 2018
  • Curtains are used for shading in windows. Since most curtains are made of flammable materials and are installed vertically, curtains can be an important factor in fire spreading. Accordingly, it is important to predict fire behaviors in studies on the combustion characteristics of flammable interior decorations, such as curtains. In this study, to analyze the combustion characteristics of six kinds of curtains, which are widely used interior decorations, the oxygen index was measured at room temperature and higher temperature. As a result of the experiment, the oxygen index at higher temperature of all specimens was about 3%~7.5% lower than that at room temperature and difference of 0.2% of oxygen index show big differences in combustion phenomenon of specimens. Therefore, when flame retardancy is evaluated with the oxygen index value of flammable interior decorations, the oxygen index value at higher temperature should be sufficiently considered.

Web Based Smart Home Automation Control System Design

  • Hwang, Eui-Chul
    • International Journal of Contents
    • /
    • v.11 no.4
    • /
    • pp.70-76
    • /
    • 2015
  • The development of technology provides and increases security as well as convenience for humans. The development of new technology directly affects the standard of life thanks to smart home automatic control systems. This paper describes a door control, automatic curtain, home security (CCTV, fire, gas, safe, etc.), home control (energy, light, ventilation, etc.) and web-based smart home automatic controller. It also describes the use of ARM (Advanced RISC Machines) for automatic control of home equipment, a Multi-Axes Servo Controller using FPGA (Field Programmable Gate Array) and PLC (programmable logic controller). Additionally, it describes the development of a HTML editor using web auto control software. The tab loading time (7 seconds) is faster when using ARM-based web browser software instead of Chrome and Firefox is used because the browser has a small memory footprint (300M). This system is realized by web auto controller language which controls and uses PLCs that are easier than existing devices. This smart home automatic control technology can control smart home equipment anywhere and anytime and provides a remote interface through mobile equipment.

Experimental Study on Flame Extinction in Buoyancy-minimized Counterflow Diffusion Flame (부력의 영향을 최소화한 조건에서 대향류 확산화염의 화염 소화에 관한 실험적 연구)

  • Chung, Yong Ho;Park, Jin Wook;Park, Jeong;Kwon, Oh Boong;Yun, Jin-Han;Keel, Sang-In
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.2
    • /
    • pp.8-14
    • /
    • 2014
  • Experiments were conducted to clarify role of the outermost edge flame on low-strain-rate flame extinction in buoyancy-suppressed non-premixed methane flames diluted with He and $N_2$. The use of He curtain flow produced a microgravity level of $10^{-2}-10^{-3}g$ in $N_2$- and He-diluted non-premixed counterflow flame experiments. The critical He and $N_2$ mole fractions at extinction with a global strain rate were examined at various burner diameters (10, 20, and 25 mm). The results showed that the extinction curves differed appreciably with burner diameter. Before the turning point along the extinction curve, low-strain-rate flames were extinguished via shrinkage of the outermost edge flame with and without self-excitation. High-strain-rate flames were extinguished via a flame hole while the outermost edge flame was stationary. These characteristics could be identified by the behavior of the outermost edge flame. The results also showed that the outermost edge flame was not influenced by radiative heat loss but by convective heat addition and conductive heat losses to the ambient He curtain flow. The numerical results were discussed in detail. The self-excitation before the extinction of a low-strain-rate flame was well described by a dependency of the Strouhal number on global strain rate and normalized nozzle exit velocity.

A Study on Characteristics of Fire in Vertical Space Using CFAST (화재시뮬레이션을 이용한 수직공간의 화재특성 분석 연구)

  • Park, Hyun-Jun;Kwon, Jin-Suk;Choi, Jae-Hyouk
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.190-190
    • /
    • 2011
  • 사회 다변화 및 급속한 경제성장과 도시밀집화로 인하여, 화재의 발생으로 인하여 막대한 인명피해 및 대규모의 재산상의 피해가 지속적으로 발생하고 있다. 이러한 화재의 피해를 예측하기 위해서는 실제 규모의 화재실험이 매우 유용하지만, 막대한 비용과 현실적 제약조건으로 인하여 실제 실험에는 많은 어려움이 따른다. 따라서 막대한 예산이 소요되는 실제규모의 화재실험의 대체방법으로 실제를 모사하는 축소모형 화재모의실험 및 컴퓨터를 이용한 화재 시뮬레이션 기법이 널리 이용되고 있다. 본 논문에서는 범용 컴퓨터를 이용한 화재 시뮬레이션 기법(CFAST)을 이용하여 수직 공간 구성을 가지는 단독주택의 화재 성상을 검토하였다. 시뮬레이션 모델로는 단독주택을 대상건물로 하여 2층으로 수직 공간을 가지는 단독주택 건물에 대한 모의 화재 시뮬레이션을 수행 하였다. 화재 시뮬레이션 결과는 각 구획실별 온도, 일산화탄소량, 공기 중 산소량 등을 도출하여 기존 이론에 의한 화재성장 그래프와 시뮬레이션 데이터를 비교하여 정확도를 검토하였다. 본 논문에서는 두가지의 시나리오를 작성하여 화재 시뮬레이션 프로그램의 결과 값을 분석하였다. (1) 시나리오 1 : 화재시뮬레이션 대상건물 1층 거실(2번방)에서 스프링클러 미 설치시 화재가 발생한 경우를 가정하여 수평방향인 3번방과 수직방향인 7번방의 화재 확산 피해정도를 살펴보고, 화재 그래프의 이론값과 실험값의 차이를 비교하여 그 정합성을 검토하였다. 발화물질은 Curtain, TV set, Sofa, Table으로 하며 시간은 60초 간격으로 총 3600초(1시간)를 분석 하였고, 발화지점의 온도, 일산화탄소, 공기중 산소 농도를 분석하였다. (2) 시나리오 2 : 시나리오 1과 동일한 화재발현 조건으로 스프링클러가 설치되어 있을 때 화재 발생 했을 경우, 수평방향인 3번방과 수직방향인 7번방의 화재 확산 피해를 시나리오 1과 비교 검토 하였다. 기존 이론에 의한 화재 성장 그래프와 이번 시뮬레이션 결과값을 토대로 만든 그래프 형태를 비교해보면 두 그래프의 형태가 비슷한 형태를 나타내어 Flash Over 현상과 Back Draft 현상이 이론값과 같은 경향을 나타내고 있음을 확인 할 수 있었다. 따라서, 본 논문에서 수행한 화재 시뮬레이션 기법으로 건축물의 실제 화재시의 피해정도를 예측하는 데 유용하게 활용될 것으로 판단된다.

  • PDF