• Title/Summary/Keyword: Fire conditions

Search Result 963, Processing Time 0.031 seconds

Nonlinear Thermo-mechanical Analysis Considering Heat Flow under Fire Conditions (화재 열 유동을 고려한 구조물의 열응력해석)

  • Pak, Hongrak;Kang, Jun Won;Lee, Jinwoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.4
    • /
    • pp.369-376
    • /
    • 2016
  • In this study, a numerical analysis framework for investigating the nonlinear behavior of structures under fire conditions is presented. In particular, analysis procedure combining fire-driven flow simulation and thermo-mechanical analysis is discussed to investigate the mechanical behavior of fire-exposed representative volume structures made of steel and concrete, respectively. First of all, fire-driven flow analysis is conducted using Fire Dynamics Simulator(FDS) in a rectangular parallelepiped domain containing the structure. The FDS simulation yields the time history of temperature on the surface of the structure under fire conditions. Second, mechanical responses of the fire-exposed structure with respect to prescribed uniformly distributed loads are calculated by a coupled thermo-mechanical analysis using the time-varying surface temperature as boundary conditions. Material nonlinearities of steel and concrete have been considered in the thermo-mechanical analysis. A series of numerical results are presented to demonstrate the feasibility of the multiphysics structural fire analysis for investigating the structural behavior under fire conditions.

Transient heat transfer analysis using Galerkin finite element method for reinforced concrete slab exposed to high elevated temperature

  • Han, Byung-Chan;Kwon, Young-Jin;Lee, Byung-Jae;Kwon, Seung-Jun;Chae, Young-Suk
    • Computers and Concrete
    • /
    • v.18 no.6
    • /
    • pp.1097-1112
    • /
    • 2016
  • Fire loading causes a critical collapse of RC (Reinforced Concrete) Structures since the embedded steels inside are relative week against high elevated temperature. Several numerical frameworks for fire resistance have been proposed, however they have limitations such as unstable convergence and long calculation period. In the work, 2-D nonlinear FE technique is proposed using Galerkin method for RC structures under fire loading. Closed-form element stiffness with a triangular element is adopted and verified with fire test on three RC slabs with different fire loading conditions. Several simulations are also performed considering fire loading conditions, water contents, and cover depth. The proposed numerical technique can handle time-dependent fire loading, convection, radiation, and material properties. The proposed technique can be improved through early-aged concrete behavior like moisture transport which varies with external temperature.

Computational study of road tunnel exposure to severe wind conditions

  • Muhic, Simon;Mazej, Mitja
    • Wind and Structures
    • /
    • v.19 no.2
    • /
    • pp.185-197
    • /
    • 2014
  • Ventilation and fire safety design in road tunnels are one of the most complex issues that need to be carefully considered and analysed in the designing stage of any potential upgrade of ventilation and other fire safety systems in tunnels. Placement road tunnels space has an important influence on fire safety, especially when considering the effect of adverse wind conditions that significantly influence ventilation characteristics. The appropriate analysis of fire and smoke control is almost impossible without the use of modern simulation tools (e.g., CFD) due to a large number of influential parameters and consequently extensive data. The impact of the strong wind is briefly presented in this paper in the case of a longitudinally ventilated road tunnel Kastelec, which is exposed to various severe wind conditions that significantly influence its fire safety. The possibility of using CFD simulations in the analysis of the tunnel placement in space terms negative effect of wind influence on the tunnel ventilation is clearly indicated.

Characteristics of Water Spray for Extinguishment of Gasoline Pool Fire (가솔린 화재의 소화를 위한 수분무의 특성)

  • Jang, Yong-Jae;Kim, Myeong-Bae
    • 연구논문집
    • /
    • s.25
    • /
    • pp.129-135
    • /
    • 1995
  • This study discribes characteristics of water spray for extinguishment of gasoline pool fire. Experiments are carried out for the gasoline pool fire in a small tank with a diameter of 150mm and a height of 8mm. Droplet size, spray pressure, amount of water which reaches the flame base and velocity of water spray are measured to find extinguishment conditions and air entrainment due to the water spray is visualized. Critical conditions of water spray for extinguishment of gasoline pool fire is quantitatively shown.

  • PDF

A New Forest Fire Detection Algorithm using Outlier Detection Method on Regression Analysis between Surface temperature and NDVI

  • Huh, Yong;Byun, Young-Gi;Son, Jeong-Hoon;Yu, Ki-Yun;Kim, Yong-Il
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.574-577
    • /
    • 2006
  • In this paper, we developed a forest fire detection algorithm which uses a regression function between NDVI and land surface temperature. Previous detection algorithms use the land surface temperature as a main factor to discriminate fire pixels from non-fire pixels. These algorithms assume that the surface temperatures of non-fire pixels are intrinsically analogous and obey Gaussian normal distribution, regardless of land surface types and conditions. And the temperature thresholds for detecting fire pixels are derived from the statistical distribution of non-fire pixels’ temperature using heuristic methods. This assumption makes the temperature distribution of non-fire pixels very diverse and sometimes slightly overlapped with that of fire pixel. So, sometimes there occur omission errors in the cases of small fires. To ease such problem somewhat, we separated non-fire pixels into each land cover type by clustering algorithm and calculated the residuals between the temperature of a pixel under examination whether fire pixel or not and estimated temperature of the pixel using the linear regression between surface temperature and NDVI. As a result, this algorithm could modify the temperature threshold considering land types and conditions and showed improved detection accuracy.

  • PDF

Analysis of the Working Conditions of Screen Fire Shutters in the Goyang Bus Terminal Fire (고양종합터미널화재 시 스크린방화셔터의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.82-91
    • /
    • 2018
  • This study analyzed the working conditions and problems of screen fire shutters in the Goyang Bus Terminal fire based on the fire investigation results. At that time, screen fire shutters in the 1st basement, which was under construction, did not work because the power was shut off. Four screen fire shutters in the 1st and 3rd floor did not work despite the power not being shut off. The following problems related to a screen fire shutter were found: shutting off the power to screen fire shutters for the fire compartment on each floor, even when the fire compartments were changed in each area; installing an integral type screen fire shutter without any regulations, installing a two-stage screen fire shutter in a place not related to obstacles during evacuation; stopping the function of the screen fire shutters for a fire compartment on each floor after a combustible sandwich panel was comparted; installing a screen fire shutter over 10 meters in width, in which its performance was not verified; and no safety control standards for reinstalling or maintaining a screen fire shutter.

A Study on Structural Analysis for Stability Evaluation According to Design Parameters of a Fire Ladder Vehicle (소방 고가사다리차의 설계 변수에 따른 안정성 평가를 위한 구조해석 연구)

  • Jung, Hoon;Kim, Cheol-Jung;Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.8
    • /
    • pp.64-72
    • /
    • 2020
  • In this study, a stability analysis was conducted through finite element analysis (FEA) of a simplified model of a fire ladder truck by changing the ascending angle, turning angle, and boundary conditions between the outrigger and the ground. The results of the analysis showed that decreasing the angle of the ladder car increases the moment due to the ladder weight, decreasing the safety factor despite being under the same load conditions. In the case of a rotating radius, the stability was found to vary depending on the boundary conditions. A comparative analysis in the future with these results and the experimental values from the actual fire ladder truck may determine the most appropriate boundary conditions based on the analysis program. It is expected to predict the risk of damage and rollover by assessing the stability of aerial ladder vehicles under different conditions.

Climate Change over Korea and Its Relation to the Forest Fire Occurrence (기후 변화에 따른 한반도 산불 발생의 시공간적 변화 경향)

  • Sung, Mi-Kyung;Lim, Gyu-Ho;Choi, Eun-Ho;Lee, Yun-Young;Won, Myoung-Soo;Koo, Kyo-Sang
    • Atmosphere
    • /
    • v.20 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This study analyzes the climate change in Korea and its impact on the occurrence of forest fire events. The forest fire occurrences in Korea tend to concentrate around large cities. In addition, the spatial distribution of the forest fire occurrence seems to agree with local climate conditions. Though the occurrence of the forest fire shows strong interannual variation, it also exhibits a positive trend. Because the forest fire frequently occurs during early spring, we examined long term climate variability in Korea for the early spring seasons. The climate change in Korea generally has brought warmer, drier, and less precipitable conditions during the early spring. The changes of the atmospheric conditions provide favorable condition for the forest fire. The climate changes in Korea also depict distinct spatial variability according to the atmospheric variables. We compared the regional trend of the fire occurrence with the climate trends. The results show the sharpest growing in the forest fire occurrence over southwest of Korea. This study suggests that the decrease in the precipitation day might affect the sharp increasement of the forest fire occurrence in the southwest of Korea.

An Analytic Study on Structural Stability according to Boundary Conditions and H-section Column Lengths Made of An Ordinary Grade Structural Steels (SS 400) at High Temperatures (일반구조용 강재(SS 400)기둥부재의 경계조건과 부재 길이변화에 따른 고온 내력의 해석적 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.20-25
    • /
    • 2014
  • Steel column is very important an structural element in steel framed building and plays a key role in sustataining the applied external load. Generally, the fire resistance performance of steel column has been executed by application of fire standard and vertical furnace having a limitation in height. Therefore, the fire resistance test was conducted with a H-section column having 3500 mm in length and hinge to hinge boundary condition. And the fire protective material derived from the fire test can be applied to any kind of boundary conditions and lengths. However, it is hard to determine the fire resistance. In this paper, to make sure the structural stability of them at high temperature according to various boundary conditions and lengths of H-section column, an analysis was done by using the mechanical properties and an heat transfer theory.