• Title/Summary/Keyword: Fire conditions

Search Result 963, Processing Time 0.026 seconds

Temperature-time analysis for steel structures under fire conditions

  • Wong, M.B.;Ghojel, J.I.;Crozier, D.A.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.3
    • /
    • pp.275-289
    • /
    • 1998
  • The objective of the paper is to present a method whereby the time required for a steel structure to sustain the effects of a prescribed temperature rise according to real fire curves can be calculated. The method is divided into two parts. The first part deals with the post-yield behaviour of steel structures at elevated temperatures. It takes into account the variation of the properties of steel material with temperature in an incremental elastoplastic analysis so that the safety factor of the structure under certain fire conditions can be assessed. The second part deals with the heat transfer problem of bare steel members in real fire. Factors affecting the heat transfer process are examined and a model for predicting the temperature variation with time under real fire conditions is proposed. This model results in more accurate temperature predictions for steel members than those obtained from previously adopted model.

Activation Conditions of Sprinkler Head Considering Fire Growth Scenario (화재성장시나리오에 따른 스프링클러 헤드의 작동조건)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.45-51
    • /
    • 2020
  • The aim of this study is to investigate the gas temperature and velocity during sprinkler activation considering the fire growth scenario based on the thermal response model of the sprinkler. The fire source is assumed to have time square fire growth scenarios with a maximum heat release rate of 3 MW. Eight types of standard and fast-response sprinkler heads with an operating temperature range of 65-105 ℃ and a response time index range of 25-171 m1/2s1/2 were adopted. The temperature difference between the gas stream and the sensing element of the sprinkler head decreased as the fire growth slowed down, and the RTI value decreased. The overall gas temperature and velocity conditions predicted using the FDS model at sprinkler activation were in reasonable agreement with those of standard test conditions of the sprinkler head response. However, the sprinkler head could be activated at lower limits of gas temperature and velocity under the current test conditions for a slowly growing fire scenario.

A Study on Pore Pressure Evaluation of Concrete Lining in Road Tunnel Fire (도로터널 라이닝 화재조건 콘크리트 라이닝 공극압력 특성에 관한 연구)

  • Park, Kyung-Hoon;Kim, Heung-Youl;Yoo, Yong-Ho;Lee, Chul-Ho;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.484-489
    • /
    • 2008
  • We carried out a one-way heating experiment on the PC panel manufactured by changing the filling depths(20,30,40,50mm) of concrete regarding the fire strength in order to measure the inner concrete pressure which is a direct cause of concrete spalling. This fire experiment was conducted under the fire strength conditions of ISO 834 Standard, Modified Hydrocarbon and the maximum value of Pore Pressure was measured. As a result of analyzing the time it took to reach maximum pressure, it showed that the time rising to the maximum pressure of high strength concrete of 40MPa is slower than that of a 24MPa tunnel lining. In case of ISO fire conditions, spalling damage might take place in heating period of $20{\sim}40$ minutes in the range of $100{\sim}200^{\circ}C$ temperature. In case of MHC fire conditions, the area damaged by fire can appear after a lapse of $25{\sim}50$ minutes in the range of $150{\sim}250^{\circ}C$ temperature.

  • PDF

Study on Changes of the Moisture Content of Sprayed Fire-Resistive Material according to Temperature Conditions (온도조건에 따른 내화뿜칠피복재의 함수율 변화 검토)

  • Lee, Gun-Cheol;Choi, Jung-Gu;Lee, Gun-Young;Kim, Dae-Hoi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.212-213
    • /
    • 2014
  • In case of fire spray protection sheath, fire resisting capacity is assessed for each material and installation method according to fire-resistive construction recognition. This study reviews effects of the percentage of water content that exist in fire spray protection sheath during the assess process of fire resisting capacity on fire resisting capacity, and changes of the percentage of water content according to temperature conditions. As a result of exams, as curing temperature is higher and thickness of specimen is thinner, decrease of the percentage of water content becomes significant.

  • PDF

Characteristics of Water Spray for Extinguishment of Gasoline Pool Fire (가솔린 화재의 소화를 위한 수분무의 특성에 관한 실험적 연구)

  • jang, Yong-Jae;Kim, Myung-Bae;Kim, Yu
    • Fire Science and Engineering
    • /
    • v.9 no.2
    • /
    • pp.10-16
    • /
    • 1995
  • This study discribes characteristics of water spray for extinguishment of gasoline fire. Experiments are carried out for the gasoline pool fire nth the atomizing nozzles. Droplet size, spray pressure, amount of water which reaches the flame base and velocity of water spray are measured to find extinguishment conditions. Air entrainment due to the water spray and extinguishing process of gasoline fire by water spray are visualized. Boundary conditions of water spray for extinguishment of gasoline pool fire is quantitatively shown. As the result of experiments, it is found that the velocity of entrainment air and sprayed water are almost same and the water droplets size having small diameter under 40$\mu\textrm{m}$ can not extinguish the fire because too small droplets does not reach the fuel surface.

  • PDF

A Study on the Estimation of Required Fire Resistance Time by Use of Building (건축물의 용도별 필요내화시간 산정에 관한 연구)

  • Kim, Yun-Seong;Han, Ji-Woo;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.115-116
    • /
    • 2020
  • Due to the nature of modern society, buildings are becoming larger and more complex. As a result, the design conditions of the building are changing. However, despite the complexities of buildings, the fire resistance performance is still equalized to one hour without considering fire engineering analysis in Korea, so there is a risk according to actual fire design conditions. Therefore, the purpose of this study is to calculate the required fire resistance time for actual fire through fire mechanics analysis and case study.

  • PDF

An Experimental Study on the Applicability of Plate Thermometer in Steady and Unsteady-State Fire Conditions (정상 및 비정상상태의 화재조건에서 판형 열유속계의 적용성에 관한 실험적 연구)

  • Yun, Hong-Seok;Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.34-41
    • /
    • 2015
  • The applicability of plate thermometer (PT), which feature simple installation and low cost, was experimentally examined in steady and unsteady-state fire conditions. An infrared radiation heater and a square burner with C3H8 as fuel were used as heat sources. The relative measurement accuracy of the PT was evaluated by comparing measurements made using a Gardon-type heat flux meter. From a practical point of view and in terms of measurement accuracy, the optimal size and thickness of the PT in steady and unsteady-state fire conditions were 100 mm and 0.6 mm, respectively. These results can be explained by the conductive heat losses and thermal inertia of the PT for different sizes and thicknesses. It can be also concluded that measurements of heat flux using the PT in conditions of faster fire growth rate than slow require considerable attention.

Consciousness of Fire Officers and Improving the Working Conditions (소방공무원 의식과 처우개선에 관한 연구)

  • Kim, Kook-Rae
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.7-18
    • /
    • 2007
  • This research intended to show a reasonable way to improve working conditions of fire officers in Korea. It shows that fire officers have dignity of their social roles even though they have the unfairness in a work time, rewards, promotions and opportunities of overseas training compared with those of other government officers. The unfairness needs to be solved. In addition, there are more demands in fire fighters, but part of a regional government system already composed of 64.06% of fire officers, which means, there are too many fire fighters in one regional government. Therefore, it is difficult to employ more fire fighters. This is one of barriers to prevent from improvement of the working conditions. To improve the working conditions and to overcome the barriers, there are important solutions to counter the problems. Those are application of alternative policies and systems. Compared with the employment system and workload of fire officers in USA, Japan and other advanced countries, it is necessary to introduce alternative policies which include operation of partial three-shift system, expansion of oversees training, expansion of rotational-off system and improvement of employees' welfare policies.

A Study on Possibility of fire ignition by Lime(CaO) (생석회에 의한 발화 가능성 연구)

  • Noh, Jeong-Yeob;Lee, Eui-Pyeong
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.102-116
    • /
    • 2011
  • With the spread of FMD and AI in the country livestock farmers have used lime(CaO) prevalently and due to incorrect storage lime served as a fire ignition source in a number of cases. As combined chemically with water, lime has exothermic reaction. Then In these experiments we want to know how exothermic reaction - caused by lime - acts as sources of fire ignition in any circumstances and conditions. So we have done experimental work of ignition temperature and ignition process in the artificial conditions as lime combined chemically with water. As a result, we have confirmed that lime could be flammable material sufficiently as a fire ignition source with the proper presence of heat and moisture conditions. If the lime served as sources of fire ignition, as identification techniques of fire scene, we must ascertain the existence of water, flammable material and Calcium Hydroxide($Ca(OH)_2$). We should take special precautions in order to prevent fire and educate the safe handling of lime to the manufacturer and agricultural cooperative's joint livestock farmers who product or use lime.

  • PDF

An Experimental Study on Relationship Between Global Equivalence Ratio and Fire Characteristics in Full-Scale Compartment Fires (실제 규모의 구획화재에서 총괄당량비와 화재특성의 상관관계에 관한 실험적 연구)

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon Hyun;Lock, Andrew
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.3
    • /
    • pp.32-39
    • /
    • 2010
  • An experimental study was conducted to investigate the relationship between global equivalence ratio(GER) and fire characteristics in an ISO 9705 room. Heptane fuel was burned with different fuel flow rates and doorway widths in order to force the room to be placed in different GER conditions. It was observed that after the onset of under-ventilated fire conditions, temperature and unburned fuel components such as CO and soot increased with increasing heat release rate (HRR), regardless of the doorway width. From the analysis of local mixture fraction, it was reconfirmed that the inclusion of soot production in the product composition was very important to predict accurately the chemical conditions inside the compartment, particularly for the under-ventilated fire conditions. In addition, the local equivalence ratio (LER) was directly proportional to the GER with a unit gradient regardless of doorway width when the soot production was included in the chemical products. This finding provided an important potential that the GER could be used to correlate the local thermal and chemical environment measured at the upper layer of a full-scale enclosure when soot was included.