• 제목/요약/키워드: Fire casualties

검색결과 195건 처리시간 0.021초

건축물 제연시스템의 송풍기에 대한 해석기술 개발 (Development of Analysis Technology on Fan in Pressure Differential System for Smoke Management)

  • 김정엽;김지석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.352-357
    • /
    • 2009
  • The fact that the major cases of life casualties are from smoke in the fire accidents and the expected steep increase of skyscrapers, huge spaces, multiplexes and huge scaled underground spaces demand establishment of efficient smoke countermeasure. The core technology for development of smoke management system is analysis tool of fan used in pressure differential system. The development of analysis technology on sirroco-typed fan using experimental and numerical methods are carried out to evaluate the features and performance of fan used in pressure differential systems.

  • PDF

콘칼로리미터를 이용한 내장판용 복합재료의 화재특성 (Fire Characteristics of Composites for Interior Panels Using Cone calorimeter)

  • 이철규;정우성;이덕희
    • 한국철도학회논문집
    • /
    • 제7권1호
    • /
    • pp.55-59
    • /
    • 2004
  • Composite materials were used widely due to merit of light weight, low maintenance cost and easy installation. But it is the cause of enormous casualties to men and properties because of weak about the fire. Particularly, it is more serious in case of subway train installed composite materials. For this reason, experimental comparison has been done fur measuring heat release rate(H.R.R) and smoke production rate(S.P.R) of interior panels of electric motor car using cone calorimeter. A high radiative heat flux of 50kW/㎡ was used to bum out all materials and to simulate the condition of fully developed fire case in the tests. It was observed that Heat Release Rate and Smoke Production Rate curves were dependent on the kinds of the interior materials. From the heat release rate curves, the sustained ignition time, peak heat release rate and total heat release rate were deduced, These data are useful in classifying the materials by calculating two parameters describing the possibility to flashover.

고양종합터미널화재 시 소방시설의 작동실태 분석 (Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.95-107
    • /
    • 2018
  • 화재조사 결과를 토대로 고양종합터미널 건물 화재 시 소방시설 작동 실태를 분석하였다. 분석결과를 요약하면 다음과 같다. 첫째, 천장 우레탄폼에 불이 붙은 직후에 옥내소화전을 이용하여 진화할 수 있음에도 시도하지 않았다. 둘째, 지하1층 대수선공사 공간은 스프링클러 알람밸브를 잠가놓아 작동하지 않았지만, 지하2층과 지상1층, 지상2층, 지상3층은 스프링클러가 작동하여 지하1층 대수선공사 공간 이외의 층으로의 화재확산을 저지하였다. 셋째, 피난유도등은 정상 작동하였지만, 터미널 2층 대합실에서 승차장 쪽으로 통하는 출구(비상구)에 피난구유도등이 설치되어 있지 않아 터미널 2층에서 다수의 사상자가 발생하게 하는데 영향을 미쳤다. 넷째, 화재수신기에서 제연설비 배기 팬 제어반에 전기신호를 보냈지만 배기 팬의 제어반에서 수동으로 취급하여 터미널 2층 제연설비 배기 팬이 작동하지 않았다.

인공신경망 기반 상업용 건축물의 화재 피난허용시간 평가 (Evaluation on Fire Available Safe Egress Time of Commercial Buildings based on Artificial Neural Network)

  • 할리오나;허인욱;최승호;김재현;김강수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.111-120
    • /
    • 2021
  • 상업용 건축물에서 화재가 발생하는 경우에는 피난경로가 복잡하고 연기 및 화염의 진행방향이 재실자의 피난방향과 비슷하기 때문에 많은 인명피해가 발생하고 있다. 인명피해를 최소화하기 위해서는 건축물에 대한 성능기반 피난설계가 필수적으로 요구된다. 성능기반 피난설계를 건축물에 적용하기 위해서는 각 건축물에 대한 복잡한 화재 시뮬레이션을 필요로 하기 때문에 많은 인력과 시간이 소요된다. 이를 보완하기 위하여, 화재 시뮬레이션을 수행하지 않고도 합리적으로 피난허용시간을 도출할 수 있는 피난허용시간 예측 모델을 개발한다면 매우 유용하게 활용될 수 있을 것이다. 이 연구에서는 상업용 건축물에 대한 화재 시뮬레이션을 수행하여 온도와 가시거리, 온도와 유독가스 농도의 상관관계를 규명하였으며, 이에 대한 데이터베이스를 구축하였다. 또한, 이를 기반으로 피난허용시간을 예측할 수 있는 인공신경망(ANN) 모델을 개발하였다. 제안된 인공신경망 모델이 다른 상업용 건축물에도 적용될 수 있는지를 검토하기 위하여 다른 상업용 건축물에 대한 검증을 수행하였으며, 제안모델은 이 상업용 건축물의 화재 시 피난허용시간을 매우 우수한 정확도로 추정하는 것으로 나타났다.

돌풍이 도로터널의 제연성능에 미치는 영향 연구 (A study on the effect of gusty wind on smoke control performance in road tunnel)

  • 백두산;조현석;이승철
    • 한국터널지하공간학회 논문집
    • /
    • 제24권1호
    • /
    • pp.95-108
    • /
    • 2022
  • 도로터널의 장대화에 따른 터널 이용객의 체류시간 증가는 화재 발생 시 피난시간이 증가하여 많은 인명피해가 발생할 수 있다. 화재에 따른 인명피해를 줄이기 위해 "도로터널설계 편람 제6편 터널"과 "도로터널 방재·환기시설 설치 및 관리지침"에서는 터널의 연장에 따른 제연설비를 설치하도록 규정하고 있다. 제연설비 설계 인자에는 외부자연풍의 풍속을 최소 2.5 m/s로 고려하도록 하고 있으며, 터널의 특성에 따라 상향하여 적용하도록 하고 있다. 그러나 터널 설계 시 외부자연풍의 풍속을 2.5 m/s로 일률적인 적용을 하고 있다. 최근 6년간 대관령 지역의 5분 평균풍속 자료를 분석한 결과 바람이 분 일 수 중 15.8%가 10 m/s 이상의 바람이 분 것으로 분석되었으며, 최대 20 m/s 까지 분 것으로 분석됐다. 따라서 본 연구에서는 터널 내 화재가 발생했을 때 터널로 유입되는 자연풍의 패턴과 최대풍속에 따른 터널 화재연기의 역류거리를 분석하였다. 그 결과 20 m/s의 돌풍이 분 경우 최대 490 m의 역류가 발생하는 것으로 분석됐다.

근접성이 불리한 대학 기숙사의 학생 의용소방대 도입에 관한 연구 (A Study on Introduction of Student Volunteer Fire Department in Dormitory far from Fire Station)

  • 백두산;이승철
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.65-69
    • /
    • 2015
  • 대학 기숙사는 기능이 다양하고 유동인구가 많아 화재발생시 많은 인명피해가 발생할 수 있다. 또한 119 안전센터와 근접성이 불리한 경우 소방대가 골든타임 내에 도착하기 어렵다. 따라서 자체적으로 화재에 대한 대응능력이 필요하다. 본 연구에서는 소방차의 현장 근접성이 불리한 강원도 K대학 기숙사 거주자를 대상으로 화재모의실험을 실시하여 재실자의 피난특성을 살펴본 결과 초기화재대응을 위한 기숙사 관리자의 부족과 피난경로의 부족으로 인하여 피난이 지연되었고, 일부 학생은 화재에 대한 의식이 부족한 것으로 나타났다. 그리고 소방대는 골든타임 내에 기숙사에 도착하지 못했다. 따라서 관리자의 부족과 소방대의 근접성이 불리함으로 발생하는 화재대응 문제를 해결하기 위해 학생의용소방대 도입을 제안했다.

철도 차량 화재시 화재강도 예측을 위한 연구 (A Study on the Prediction of Fire Load in case of a Train Fire)

  • 양성진;장정훈;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2101-2108
    • /
    • 2008
  • Most of train fires which occur in usual cases do not grow up significantly on a large scale enough to bring about casualties and harmful damages. However, the consequence of some train fire accidents can be devastating disaster so that it would be even recorded in history in unusual cases. Accordingly, such a probability of fire disaster cannot be ignored in aspect of the railway safety assesment. A scale of injury and damage is very difficult to predict and analyze. Because it is depend on various factors, i.e. fire load, burning period, facilities, environment condition, and so on. Thus, a prediction of fire load could be understood as a one methodology to estimate railway safety assesment. The summation method which is one of them is used to evaluate the overall fire load by assuming that sum of heat release rate per unit area or mass of each composite material equals the total. However, since the train fire is classified into a compartment fire in under-ventilation condition. The summation method do not estimate a fire load completely. In this journal, Various methods to predict fire load are introduced and evaluated. Especially the fire simulation tool FDS(Fire Dynamics Simulator)which is based on the CFD(Computational Fluid Dynamics) is introduced, too. Through the FDS simulation, numerical analyses for the fire load and flame spread are performed. Then, these results of the simulation are validated through the comparison study with the experimental data. Then, limitations and approximations including in simulation process are discussed. The future direction of research is proposed.

  • PDF

고층 건물 화재 관련 R&D 위상 분석 및 신기술 탐색 연구 (R&D Monitoring and Novel Technology Exploration Concerning Research Area about Fire in High-rise Building)

  • 심위;최재경;정현상;허요섭;서성호
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.271-280
    • /
    • 2020
  • Due to the development of the urban economy, high-density buildings and skyscrapers have continued to increase in order to alleviate high population densities and to make efficient use of urban space. However, a fire in a high-rise building is a disaster that can lead to massive casualties and property damage because of the difficulty of firefighting and escaping. Various studies have been conducted on these high-rise buildings because they are sympathetic to these difficulties all over the world. In this paper, trends of researches and technologies related to fire in high-rise buildings are analyzed synthetically through thesis and patent data. In other words, we explored the trends of various studies that have been carried out so far through the thesis, and performed technical monitoring on actual implemented technology and newly implemented technologies through patent data. Through this research, we have studied the present and the future of technology for high-rise building fire.

화재사고사례를 통해서 본 건설현장 지하공간에서의 유기용제의 위험성에 대한 연구 (A Study on the Risk of Organic Solvents for Underground Area under Construction Site through a Fire Accident Case)

  • 안병준;정기혁;이정석;임종국
    • 한국가스학회지
    • /
    • 제22권1호
    • /
    • pp.9-17
    • /
    • 2018
  • 건설현장은 다른 산업분야와 달리 다양한 형태의 공정을 동시에 진행하는 작업적 특성을 가지고 있어서 사고를 예방하는데 많은 어려움이 있다. 특히 소방설비가 정상적으로 설치되지 않은 상태에서 인화성물질과 화기작업이 동시 다발적으로 진행되는 경우가 많아서 큰 화재사고로 이어지고는 한다. 본 연구에서는 2016년 발생한 김포 화재사고를 통해서 작업자가 물질의 위험성을 인지할 수 있는 유일한 수단인 물질안전보건자료의 신뢰도와 유증기 분석으로 보다 합리적인 재발방지 대책을 제시하고자 하였다.

Evacuation Safety Evaluation of High School according to Hydrogen Fluoride Leakage

  • Boohyun Baek;Sanghun Han;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.255-266
    • /
    • 2024
  • The purpose is to evaluate evacuation safety by simulating the toxic effects of hydrogen fluoride leaks in areas surrounding national industrial complexes and to suggest alternatives for areas that do not satisfy evacuation safety. For human casualties caused by hydrogen fluoride leakage accidents, Available Safe Egress Time (ASET) is calculated by the toxic effects quantified with the Areal Locations of Hazardous Atmospheres (ALOHA), an off-site consequence assessment program. The Required Safe Egress Time (RSET) is calculated through Pathfinder, an evacuation simulation program. Evacuation safety is assessed by comparing ASET and RSET. The ALOHA program was used to evaluate the time to reach AEGL-2 concentration in 12 scenarios. The Pathfinder program was used to assess the total evacuation time of the high school among specific fire-fighting objects. Of the 12 accident scenarios, ASET was larger than RSET in the worst-case scenarios 1 and 9. For the remaining 10 accident scenarios, the ASET is smaller than the RSET, so we found that evacuation safety is not guaranteed, and countermeasures are required. Since evacuation safety is not satisfactory, we proposed to set up an evacuation area equipped with positive pressure equipment and air respirators inside specific fire-fighting objects such as the high school.