• Title/Summary/Keyword: Fire alarm

Search Result 257, Processing Time 0.027 seconds

A Study on the Fire Alarm System of Vertical Fire Spread Structure by Using FDS (FDS을 이용한 수직 연소확대 구조의 화재경보방식에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.100-107
    • /
    • 2016
  • Today, high-rise buildings expected to meet various needs and improve the quality of frequency of fire and the potential risks are increasing. In particular, the fire spread risk in the vertical direction is increasing. As a result there is a problem with delays in the evacuation time of occupants. To overcome this problem, there is a need to consider the structure of the building and develop a system for the early detection of fire by applying a fire alarm system according to the risk ranking. Therefore, this paper describes the vertical fire spread characteristics of a multistory double-skin and stairs structure with risk. The data were compared with that from the national and international fire alarms as well as with. smoke density, smoke detectors, visibility, and CO concentration using FDS. A fire alarm system for each structure is proposed.

A Study on the Propagation Characteristics of Fire Alarm Sound in Buildings (화재비상경보음의 건물 내 전달특성에 관한 연구)

  • Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.153-160
    • /
    • 2009
  • This study aims to review the propagation characteristics of fire alarm sound in building through computer simulation. In order to achieve this goal, the sound power level of existing three different emergency alarms were measured in an anechoic chamber. Sound power level of alarm bell was 98.6dB and electronic-siren speaker was 95.7dB, and electronic-siren phon was 101.8dB at the voltage of DC 24V in the condition of anechoic chamber. As the results of acoustic simulation, it was shown that sound levels at the corridor of the building were relatively high and even. But, there were large difference in sound level at all the frequency bands between corridor and lecture rooms. This mean that alarm sound couldn't be recognized sometimes in lecture rooms. Through the computer simulation, the propagation characteristics of fire alarm sound could be forecasted and compared due to plans of buildings.

Prediction and Reduction of Alarm Sound Propagated through Elevator Shaft (엘리베이터 샤프트를 통한 경보음 전달 예측과 개선)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.89-96
    • /
    • 2019
  • In this study, alarm sound generated as a priority alert system propagation through an elevator shaft in apartment buildings were simulated using room acoustic simulation software. The simulations were conducted on three kinds of elevator hall plan with a different number of elevators and placement. First, the elevator shaft without sound absorption material was simulated as a condition of the present. When the distance from the alarm sound generating floor became farther, alarm sound level was decreased. However, the alarm sound level three-floor distance was about 54 dB(A)~56 dB(A) which were louder than a background sound level of typical apartment buildings. Sound absorption material placement proposed by previous studies were simulated and the alarm sound levels were decreased about 12 dB~16 dB. These levels were similar or lower than the background level of apartment buildings. From these results, it can be concluded that placing sound absorption material on the surface of the elevator shaft wall can be one of the methods to control the alarm sound as regulated in NFSC.

A study on the design of a general-purpose automatic fire detection system based on a private wireless network of the fire fighting communication frequency band (소방통신 주파수 대역 자가 무선망 기반 범용 자동 화재 탐지 시스템 설계를 위한 연구)

  • Kim, Minyoung;Choi, Donggyu;Jang, Jongwook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.246-248
    • /
    • 2021
  • This paper proposes a new general-purpose automatic fire detection system. And it deals with the contents of related research on how to design and develop for this system. The proposed system automatically notifies the user and the nearby fire department when a fire breaks out in a place where a fire alarm is installed. If this is the case, the nearby fire department can quickly confirm this fact and extinguish the fire at an early stage, thereby reducing human and property damage. The main targets of this system are houses and small buildings. The proposed fire alarm functions as a conventional fire alarm, and if a fire occurs, this fact is immediately transmitted to a nearby receiver through wireless data communication. The receiver in this paper communicates data using Korea's firefighting communication frequency band, and establishes one own network by installing it in various places to quickly receive fire alarm data at any time.

  • PDF

A Study on the Prevention and Extinguishment of Fire in Vinyl Temporary Buildings for Agriculture and Fishery (농·어업용 Vinyl 가설건축물의 화재 예방 및 진압에 관한 연구)

  • Bong-Woo Lee;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.599-603
    • /
    • 2023
  • Analyzed in the NFDS, The average number of fires in vinyl temporary buildings is more than 1,000 in annually. And the number of deaths and injuries was around 30 people in every year. According to the National Fire Agency, There are 142,386 vinyl temporary buildings for Agriculture and Fishery, of which 4,720 are residential vinyl temporary buildings in illegally. Model house is subject to regulation in fire-related law. But, even though it's the same temporary building, Vinyl temporary building is not subject to regulation. For this reason, Vinyl temporary buildings are left in the blind spot of fire safety. Therefore, In this study, We propose that amend of Act on installation and management of firefighting systems, make of temporary fire safety controller, develop and apply of alarm system that is connected to a single-alarm smoke dretector, organize and operate volunteer fire brigade of the crop group to prevent and extinguish the fire.

A Novel Design of the Distributed Fire Alarm Control System by Developing Intelligent Control Modules with LonTalk Protocol (지능형제어기를 이용한 분산 방계시스템에 관한 연구)

  • 홍원표;이승학
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.157-162
    • /
    • 2001
  • There are many economic and operational reasons to integrate fire alarm signaling system with other building automation system. Integration of this requires communication standard and careful design practices. The important point for this is also the development of intelligent control modules for replacing the conventional zone adapter in fire system. Therefore, this paper proposes an new conceptual design of the distributed fire alarm signaling system and a new intelligent control modules with LonTalk protocol. Newly proposed additions to LonWorks network make it very well suited for integrating fire systems with other building automation systems. Additionally, it is very important that best design practices, test procedures and building codes need to be modernized to accommodate Integrated building systems.

  • PDF

A Novel Design of the Distributed Fire Alarm Control System by Developing Intelligent Control Modules with LonTalk Protocol

  • Hong, Won-Pyo;Goo, Sung-Hoan;Park, Won-Guk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.70.6-70
    • /
    • 2001
  • There are many economic and operational reasons to integrate fire alarm signaling system with other building automation system. Integration of this requires communication standard and careful design practices. The important point for this is also the development of intelligent control modules for replacing the conventional zone adapter in fire system. Therefore, this paper proposes an new conceptual design of the distributed fire alarm signaling system and a new intelligent control modules with LonTalk Protocol. Newly proposed additions to Lonworks network make it very well suited for integration fire systems with other building automation systems. Additionally, it is very important that best design practices ...

  • PDF

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

A Study on the Smart Fire Detection System using the Wireless Communication (무선통신을 이용한 스마트 화재감지 시스템에 관한 연구)

  • Chung, Byoung-Chan;Na, Wonshik
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.37-41
    • /
    • 2016
  • In this paper, we propose a fire alarm system that utilizes Wi-Fi to alarm multiple people at once. This system, based on Arduino, uses smoke, flame and temperature sensor units to sense fire and send detection data to a server via wireless communication system. The server uses stored data to relay current fire situations gathered from nearby sensors to smartphones. It also automatically reports the fire using location data from sensors. Using this system, we were able to retrieve fire alarm from sensors via push notification of our smartphone. We also confirmed the establishment of linkage with sensors and automatic report of fire via SMS. From this result, the possibility of sending real-time notifications via the Internet toward nearby smartphones about disasters such as conflagration has been proven to be feasible.