• Title/Summary/Keyword: Fire accident

Search Result 701, Processing Time 0.025 seconds

Interference and Re-Inflow of Contaminated Air in Successive Tunnel (연속터널에서의 오염물질 재유입 및 환기영향평가)

  • Kim, Young-Geun;Kim, Woo-Sung;Wye, Yong-Gon;Kim, Nam-Yung;Lee, Ho-Suk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.2
    • /
    • pp.115-134
    • /
    • 2003
  • Recently, there are many cases in the roadway design for successive tunnel with small distance between two tunnels. In this case, the degree of interference for successive tunnels is a significant consideration in the design of ventilation systems. Also, Re-inflows of contaminated air in successive tunnel make serious ventilation problems in case of fire accident in the tunnel. In this study, for successive tunnels in Donghae highway project, the concentration of contaminant such as CO, NOx and Smoke were calculated by numerical analysis using 1D and 3D-CFD analysis. And, the rate of re-inflow at the portals of successive tunnel according to the direction of wind were analysed.

  • PDF

A Study on Consequence Analysis of LNG/LPG/Gasoline Station (LNG/LPG/가솔린 Station의 사고피해영향평가 비교)

  • Yoo, Jin-Hwan;Kim, Bum-Su;Lee, Heon-Seok;Ko, Euy-Seok;Lee, Gi-Baek
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.54-60
    • /
    • 2009
  • The advancement of industry have increased domestic energy demands and energy facilities such as storage facility, compressed gas pipe, station, and tank lorry. Also, concern about environment have diversified energy source to clean energy such as LNG. In these major energy facilities, major accident can happen to result in fire, explosion, toxic release and etc. In addition, it may cause chain accidents to the adjacent energy facilities. In this research, safety assessment was performed through the consequence analysis of LPG liquefied petroleum gas) station, gasoline station and LNG(liquiefied natural gas) station. The obtained result will be helpful to make a safety guideline of the LPG/LNG station built adjacent to the gasoline station.

  • PDF

A Study on Estimation of Human Damage for Overpressure by Vapor Cloud Explosion in Enclosure Using Probit Model (프로빗모델을 통한 밀폐공간에서의 증기운폭발 과압에 의한 인체피해예측)

  • Leem, Sa-Hwan;Lee, Jong-Rark;Huh, Yong-Jeong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.42-47
    • /
    • 2008
  • The demand of gas as an eco-friendly energy source has being increased. With the demand of gas, the use of gas is also increased, so injury and loss of life by the explosion and fire have been increasing every year. Hence the influence on over-pressure caused by Vapor Cloud Explosion in enclosure of experimental booth was calculated by using the Hopkinson's scaling law and damage effect by the accident to a human body was estimated by applying the probit model. As a result of the damage estimation conducted by using the probit model, both the damage possibility of explosion overpressure to human over 3 meters away and that of overpressure to tympanum rupture over 25 meters away from the explosion shows nothing.

  • PDF

A Study on the Development of Smart Control Valve (스마트 컨트롤 밸브 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.582-590
    • /
    • 2019
  • As Korea's low fertility and aging progress, Korea is facing a social change such as an increase of one generation by entering an aging society that has raised 14% of the population. An effective way to prevent a gas fire accident caused by an increase in one generation in an aging society is to install a control valve to forcibly shut off the gas after a set time. In this study, we developed a valve that can be opened and closed by rotating the valve left and right by transmitting power to the worm gear and the helical gear by using a motor by pressing the switch. It is easy to assemble and inspect by developing a dedicated valve that is easy to attach and detach. It was developed to enhance competitiveness by reducing cost by reducing the number of parts and product size. In addition, through endurance test, it was developed to be used for more than 9 years by repeating ON / OFF once every 12 seconds so that it can operate stably for 10,000 times for 34 hours. The instrument and PCB were designed using solid works and Altium Designer tools. Firmware development was developed in IAR Embedded Workbench environment.

Development of a Standard Checklist for Protection to Electrical Accidents of Laboratory (연구실 전기사고방지를 위한 표준체크리스트개발)

  • Lee, Dong-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.108-115
    • /
    • 2011
  • This paper informs the standard guideline of electrical inspection for the University laboratories and R&D institutes. A routine electrical inspection is there to prevent an electric shock and electrical fire accident in the Lab. The main issue of this paper is to check the problem of a routine electrical inspection and this paper provides a detailed guideline of a checklist for the Lab which do not have detailed instruction. It mentions the standard model of an effective routine inspection to upgrade the weak electrical environment in the Lab. One of the main purposes of this paper is to develop a routine checklist to control the electrical environment in the Lab. The evaluation checklist we develop will then be applied to every Lab. Introducing an electrical safety checklist builds a clear standard guideline for a real safety check. This will be used as a regular routine check-up for every Lab. The goal of this paper is to enforce safety from electrical accidents in the lab and it will provide safety guidelines for every Lab.

Change in Physical Properties of Engine oil Contaminated with Diesel (경유 혼입에 의한 엔진오일 물성 변화)

  • Lim, Young-Kwan;Lee, Jong-Eun;Na, Yong-Gyu;Kim, Jong-Ryeol;Ha, Jong-Han
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.45-51
    • /
    • 2017
  • Engine oil is a substance used for the lubrication of internal combustion systems. However, in some case, defects in engine systems may contaminate engine oil with fuel. Contaminated engine oil can cause problems in the normal functioning of a vehicle. In this study, we investigate the functional properties of engine oil contaminated with diesel fuel. The test results indicate that the engine oil contaminated with diesel fuel has low flash point, pour point, density, kinematic viscosity and cold cranking simulator value. The contaminated engine oil which has low plash point can cause fire and explosion accident. Furthermore, a four ball test indicates that the contaminated engine oil increases wear scar to poor lubricity. Moreover, we investigate the GC pattern using SIMDIST (simulated distillation) for determination of diesel in engine oil. The SIMDIST analytic result, diesel was detected at earlier retention time than engine oil in chromatogram. Thus the SIMDIST method can define whether engine oil is contaminated by diesel fuel or not. We can use the SIMDIST method for the diagnosis of oil condition instead of analyzing other physical properties that require many analytic instruments, large volume of oil sample and long analysis time.

Development of A News Event Reenactment System (사건재연 시스템 개발)

  • 윤여천;변혜원;전성규;박창섭
    • Journal of Broadcast Engineering
    • /
    • v.7 no.1
    • /
    • pp.21-27
    • /
    • 2002
  • This paper presents a mews event reenactment system (NERS), which generates virtual character animations in a quick and convenient manner. Thus, NERS can be used to produce computer graphics(CG) scenes of news events that are hard to photograph, such as fire, traffic accident, cases of murder, and so on. By using plenty of captured motion data and CG model data this system produces an appropriate animation of virtual characters straightforwardly without any motion capturing device and actors in the authoring stage. NERS is designed to be capable of making virtual characters move along user-defined paths, stitching motions smoothly and modifyingthe positions and of the articulations of a virtual character in a specific frame. Therefore a virtual character can be controlled precisely so as to interact with the virtual environments and other characters. NERS provides both an interactive and script-based (MEL: Maya Embedded Language) interface so that user can this system in a convenient way. This system has been implemented as a plug-in of commercial CG tool, Maya (Alias/wavefront), in order to make use of its advanced functions

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

Analysis on the Perception of Nuclear Power Plant and the Preference of its Policy Alternatives for Public Acceptance (원자력발전소에 대한 인식과 국민수용성 향상을 위한 정책대안들의 선호 분석)

  • Park, Young-Sung;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.27 no.1
    • /
    • pp.33-44
    • /
    • 1995
  • Public acceptance has become an important factor in nuclear power program particularly after Chernobyl accident and recent rapid democratization in Korea. Methods reflecting public opinions in order to improve public acceptance are firstly to understand what the public think about nuclear power plant and secondly to find out the public preference values for its policies. For this purpose, simplified multi-attribute utility (MAU) model was applied to analyze the public perception pattern for fire power production systems. And the conjoint analysis was applied to find out the quantitative values of public preferences for twelve policy alternatives to improve the safety and to support communities surrounding nuclear power plants in Korea. To implement these perception and preference analyses, mail survey was conducted to the Qualified sample who had the experience of visiting nuclear power plant. Diagnosis of their perception pattern for five power production systems was made by the simplified MAU model. Estimation of the quantitative preference values for potential policy alternatives was made by the conjoint measurement technique, which made it possible to forecast the effectiveness of each option. The results from the qualified sample and the methods used in this study would be helpful to set up new policy of nuclear power plant.

  • PDF

A Study on the Integrated Monitoring of a Leakage Current of the Grounding Wire of Neutral Point of the Low Voltage Side of Transformer (변압기 저압측 중성점 접지선의 누설전류 통합 감시에 관한 연구)

  • Hong, Soon-Seuk;Park, Joon-Yeol;Lee, Jung-Eun;Choi, Kyung-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.106-113
    • /
    • 2010
  • If leakage current is neglected, it can become a cause for disasters such as electric shock and fire, therefore a continuous monitoring is necessary. However in most cases, because management of substations is performed by unmanned systems, or walk-around inspections, continuous monitor is difficult. So when an accident occurs and the cause is not immediately resolved causing the emergency generator's OCGR getting activated by the leakage current that in turn cut off the ACB, the emergency generator may stop working. To prevent such a problem, a real-time integrated monitoring system for monitoring the leakage current returning to the grounding wire of neutral point of the low voltage side of transformer is proposed. Therefore in this paper, the effects of flow of leakage current, which is caused by insulation degradation phenomena or insulation destroy phenomena, were identified by simulation. And through cases studies; the excellence of integrated monitoring system was verified.