• Title/Summary/Keyword: Fire Test

Search Result 1,899, Processing Time 0.025 seconds

Nursing Students' Patient Safety Competency and Patient Safety Management Practice (간호대학생의 환자안전 역량과 환자안전관리 행위)

  • Park, Jung-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.216-223
    • /
    • 2019
  • This study was conducted to identify the effects of patient safety competency on patient safety management practice by nursing students and provide basic data for the development of the program to improve patient safety management practice. Participants were 293 fourth year nursing students who had clinical practice as student nurses for more than one year. Data were collected from April 26 to May 9, 2018. Collected data were analyzed for frequency, percentage, mean, standard deviation, t-test, ANOVA, Pearson' s correlation coefficient, and multiple regression with SPSS/WIN 24.0 computer program. Nursing students' patient safety competency was an average $2.90{\pm}0.38$ points (patient safety knowledge $2.68{\pm}0.65$; patient safety skills $3.26{\pm}0.56$; patient safety attitudes $2.75{\pm}0.40$). The average core of management practices to patient safety recorded $4.13{\pm}0.57$ points. In terms of the correlation among subjects' patient safety knowledge, skills, attitudes and patient safety management practices, significant correlation existed between skills and management practices (r=.337, p<.001), attitudes and management practices (r=-.150, p =.010), knowledge and management practices (r=.171, p=.003). Regression analysis revealed that 15.7% of the variance in patient safety management practice by nursing students could be explained by patient safety skills (${\beta}=.307$, p<.001), patient safety accident experience of Fire (${\beta}=-.127$, p=.026), patient safety attitudes (${\beta}=-.121$, p=.026), and patient safety accident experience of patient education (${\beta}=-.119$, p=.034). Additional studies to determine the various factors affecting patient safety management practice of nursing students and to develop educational program for increasing patient safety management practice should be conducted.

A Case Study on Performance Analysis of Antimicrobial Copper Film Attaching to Window for Responding to COVID-19 and Others (코로나19 등 대응을 위한 "유리창 부착용 항바이러스 동필름" 성능분석 사례연구)

  • Kim, Seong Je
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.1
    • /
    • pp.23-40
    • /
    • 2021
  • In the era of the global coronal 19 pandemic, there is a risk of cross-infection in hospitals at the stage where treatments and vaccines are currently being developed and marketed, so individuals should enhance their acquired immunity and generalize their living systems by the performance of copper ions in the social environment. In order to prevent the spread of infection, the need for anti-bacterial film and its efficacy were analyzed through anti-viral performance tests based on research and development cases of worldwide and immemorial time. he Korea Construction Research Institute (KCL) has received anti-bacterial performance certification and anti-viral test scores from the "National Approval Performance Certification Agency." At the time, NCCP 43326 Human Corona virus (BetaCoV/Korea/KCDC03/2020), which was approved by the Centers for Disease Control and Prevention, was introduced to ensure that the activity rate of infected cells was satisfied in the anti-viral performance test. Anti-proliferation measures for the Corona 19 virus require a quality clinical trial study comparing the experimental group within the glass space where the antiviral copper film is constructed with the comparator of the same condition without copper film.

Influence of Transverse Reinforcement Elements for Flexural Strength of Lap Spliced Ultra-high-strength Reinforced Concrete Beams (겹침이음된 초고강도콘크리트 보의 휨강도에 횡방향보강 요소가 미치는 영향)

  • Bae, Baek-Il;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.135-142
    • /
    • 2022
  • In this study, lap spliced ultra-high strength reinforced concrete beams were tested and the code criteria for calculating the lap splice length which was affected by the transverse reinforcement and concrete covering performance were reviewed. The main variables for test were set as fiber volume fraction and transverse reinforcing bar arrangement to improve the confining performance of the concrete cover. The change of the confining performance of concrete cover according to the increase in the fiber mixing amount at 1% and 2% volume ratio was examined, and D10 stirrups with a spacing of 100 mm were placed in the lap spliced region. As a result of the test, the specimens confined by the stirrups showed a sudden drop of load bearing capacity with horizontal cracking at the position of tensile longitudinal reinforcement. However, horizontal cracks were not appeared at the location of longitudinal reinforcement for the specimens with steel fiber. And these specimens showed gradual decrease of load bearing capacity after experiencing peak load. In particular, it was found that the strain at the position of the tensile longitudinal reinforcements of the specimens to which the mixing ratio of 2% was applied exceeds the yield strain. As a result of measuring the strain on the concrete surface, it was found that the fiber was more effective in preventing damage to the concrete surface than the stirrups for short lap spliced region.

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

Explosion Likelihood Investigation of Facility Using CVD Equipment Using SEMI S6 (SEMI S6를 적용한 CVD 설비의 폭발분위기 조성 가능성 분석)

  • Mi Jeong Lee;Dae Won Seo;Seong Hee Lee;Dong Geon Lee;Se Jong Bae;Jong-Bae Baek
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.62-67
    • /
    • 2023
  • Due to the prolonged impact of COVID-19, the demand for Information Technology (IT) products is increasing, and their production facilities are expanded. Consequently, the use of harmful and dangerous chemicals are increased, the risk of fire(s) and explosion(s) is also elevated. In order to mitigate these risks, the government sets standards, such as KS C IEC 60079-10-1, and manages explosion-prone hazardous facilities where flammable substances are manufactured, used, and handled. However, using the standards of KS, it is difficult to predict the actual possibility of an explosion in a facility, because ventilation (an important factor) is not considered when setting up a hazardous work environment. In this study, the SEMI S6, Tracer Gas Test was applied to the chemical vapor deposition (CVD) facility, a major part of the display industry, to evaluate ventilation performance and to confirm the possibility of creating a less explosive environment. Based on the results, it was confirmed that the ventilation performance in the assumed scenarios met the standards stipulated in SEMI S6, along with supporting the possibility of creating a less explosive working condition. Therefore, it is recommended to use the prediction tool using engineering techniques, as well as KS standards, in such hazardous environments to prevent accidents and/or reduce economic burden following accidents.

Predictive Factors on Blood Donation Intention in Middle Aged Base on the Theory of Planned Behavior : Focused on the Firefighter and Prison Officer (계획된 행위 이론에 근거한 중장년층의 헌혈 의도 영향요인 : 소방직과 교정직 중심으로)

  • Da Jung Lee;Hye-Kyung Lee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.199-209
    • /
    • 2023
  • This study is a descriptive research to identify the factors that influence blood donation intentions of the middle-aged firefighters and prison officer based on Ajzen's (1991) planned behavior theory. The subjects of the study were 223 middle-aged firefighters and prison officer at a fire station and prison located in G City and District B. The Data were analyzed by descriptive statistics and t-test, one-way ANOVA, Pearson's correlation coefficient, Turkey, and multiple regression with the SPSS 21.0 program. There were statistically significant differences in blood donation intention according to the blood donation experience, attempted blood donation within a year, participate plan in blood donation within 3 months. The blood donation intention of middle aged showed significant positive correlations with attitude, subjective norms, and perceived behavioral control towards blood donation. Multiple regression analysis for blood donation intention revealed that the significant predictors were participate plan in blood donation within 3 months, perceived behavior control, subjective norms, attitude towards blood donation, and attempted blood donation within a year. These factors explained 69% of the variance. In order to enhance the middle aged's intention to blood donation, we need a program that can improve middle aged's attitude, subjective norms, perceived behavior control.

District-Level Seismic Vulnerability Rating and Risk Level Based-Density Analysis of Buildings through Comparative Analysis of Machine Learning and Statistical Analysis Techniques in Seoul (머신러닝과 통계분석 기법의 비교분석을 통한 건물에 대한 서울시 구별 지진취약도 등급화 및 위험건물 밀도분석)

  • Sang-Bin Kim;Seong H. Kim;Dae-Hyeon Kim
    • Journal of Industrial Convergence
    • /
    • v.21 no.7
    • /
    • pp.29-39
    • /
    • 2023
  • In the recent period, there have been numerous earthquakes both domestically and internationally, and buildings in South Korea are particularly vulnerable to seismic design and earthquake damage. Therefore, the objective of this study is to discover an effective method for assessing the seismic vulnerability of buildings and conducting a density analysis of high-risk structures. The aim is to model this approach and validate it using data from pilot area(Seoul). To achieve this, two modeling techniques were employed, of which the predictive accuracy of the statistical analysis technique was 87%. Among the machine learning techniques, Random Forest Model exhibited the highest predictive accuracy, and the accuracy of the model on the Test Set was determined to be 97.1%. As a result of the analysis, the district rating revealed that Gwangjin-gu and Songpa-gu were relatively at higher risk, and the density analysis of at-risk buildings predicted that Seocho-gu, Gwanak-gu, and Gangseo-gu were relatively at higher risk. Finally, the result of the statistical analysis technique was predicted as more dangerous than those of the machine learning technique. However, considering that about 18.9% of the buildings in Seoul are designed to withstand the Seismic intensity of 6.5 (MMI), which is the standard for seismic-resistant design in South Korea, the result of the machine learning technique was predicted to be more accurate. The current research is limited in that it only considers buildings without taking into account factors such as population density, police stations, and fire stations. Considering these limitations in future studies would lead to more comprehensive and valuable research.

IoT-based Smart Tunnel Accident Alert System (사물 인터넷 기반의 스마트 터널 사고 경보 시스템)

  • Ki-Ung Min;Seong-Noh Lee;Yoon-Hwa Choi;Yeon-Taek Hong;Chul-Sun Lee;Yun-Seok Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.753-762
    • /
    • 2024
  • Tunnels have limited evacuation areas, and It is difficult for cars coming from behind to recognize the accident situation in front. Since an accident is very likely to lead to a serious secondary accident, a IoT-based smart tunnel accident warning system was studied to prepare for traffic accidents that occur in tunnels. If the measured values from the flame detection sensor, gas detection sensor, and shock detection sensor in the tunnel exceed the standard, it is judged to be an emergency situation and an alert system is designed to operate. The accident information message was designed to be displayed on the LCD and transmitted to drivers inside and outside the tunnel through a Wi-Fi communication network. A performance test system was established and performance evaluation was performed for several accident scenarios. As a result of the test, it was confirmed that the accident alert system can accurately detect accidents based on given reference values, perform alert procedures, and transmit alert messages to smart phones through Wi-Fi wireless communication. And through this, its effectiveness could be confirmed.

The effects of out of hospital ACLS simulation training on the paramedic's duty ability (구급대원의 전문심장소생술 시뮬레이션훈련이 직무수행융합능력에 미치는 영향)

  • Park, Yoo-Na;Cho, Byung-Jun;Kim, Gyoung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.99-106
    • /
    • 2019
  • The purpose of this study is to analyze the effects of the simulation-based professional cardiac resuscitation training on the performance of professional cardiac resuscitation performed by paramedics in the pre-hospital stage and to provide basic data for effective cardiac resuscitation. This study is an experimental study of the design before and after the control of non-equality. The subjects of this study were 16 newly recruited paramedics from K firefighting school. The simulation training program and evaluation papers used as the evaluation tool were reviewed and commented by 6 ACLS simulation experts (2 emergency medical doctor, 2 emergency medical professors, 2 KALS instructors)Respectively. The training consisted of 30 minutes of theory and 150 minutes of practical training. The lecturer first demonstrated for 5 minutes, and after training by individual debriefing after individual training, individual and team education was conducted The evaluation scale was given a 5 - point Likert scale. The SPSS 22.0 program for Windows was used. The general characteristics of the subjects were analyzed for frequency, the examination of homogeneity between the experimental group and the control group wasfulfilled by t test, and the difference test between the groups of the two groups was performed using the paired t-test. The homogeneity test was able to confirm the homogeneity between experimental group and control group. In the evaluation of six ACLS techniques, it was proven that the experimental group that received the simulation training had better performance in all aspects than the non - training control group. The following are the technical items to be performed. 1. Electrocardiogram 2. Specialized instrument 3. Treatment of fluid 4. Leadership and teamwork 5. Medical guidance 6. Evaluation during transfer. It was proved that paramedics who received simulation training were improved on their job performance ability than general lecture and training group. Therefore, if simulation training and education are applied to a student in the synthetic course or an emergency resident who is engaged in clinical practice, he / she will be able to perform his / her duties more proficiently. It is expected that emergency services provided to patients with cardiac arrest will be improved.

Evaluating Impact Resistance of Externally Strengthened Steel Fiber Reinforced Concrete Slab with Fiber Reinforced Polymers (섬유 보강재로 외부 보강된 강섬유 보강 콘크리트 슬래브의 충격저항성능 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.293-303
    • /
    • 2012
  • Recently, as construction technology improved, concrete structures not only became larger, taller and longer but were able to perform various functions. However, if extreme loads such as impact, blast, and fire are applied to those structures, it would cause severe property damages and human casualties. Especially, the structural responses from extreme loading are totally different than that from quasi-static loading, because large pressure is applied to structures from mass acceleration effect of impact and blast loads. Therefore, the strain rate effect and damage levels should be considered when concrete structure is designed. In this study, the low velocity impact loading test of steel fiber reinforced concrete (SFRC) slabs including 0%~1.5% (by volume) of steel fibers, and strengthened with two types of FRP sheets was performed to develop an impact resistant structural member. From the test results, the maximum impact load, dissipated energy and the number of drop to failure increased, whereas the maximum displacement and support rotation were reduced by strengthening SFRC slab with FRP sheets in tensile zone. The test results showed that the impact resistance of concrete slab can be substantially improved by externally strengthening using FRP sheets. This result can be used in designing of primary facilities exposed to such extreme loads. The dynamic responses of SFRC slab strengthened with FRP sheets under low velocity impact load were also analyzed using LS-DYNA, a finite element analysis program with an explicit time integration scheme. The comparison of test and analytical results showed that they were within 5% of error with respect to maximum displacements.