• Title/Summary/Keyword: Fire Safety Measures

Search Result 331, Processing Time 0.025 seconds

A Study on Improvement of Professional Fire Investigation Education and Certification System (화재조사전문교육 및 자격증제도 개선에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.32-42
    • /
    • 2009
  • This study aims to analyze operation status of the professional fire investigation education in Korea and derive improvement measures. Study results showed that professional fire investigation educations are conducted mainly by public sectors (Fire Service, Police, Korea Electrical Safety Corp, Korea Gas Safety Corp, etc.) and the educations conducted by National Fire Service Academy are most systematic. In addition, there was no professional fire investigation educations conducted for private sector (fire accident suffers, common peoples, etc.) In order to improve the problems, this study suggests changing the National Fire Service Academy to lifelong education system in coordinance with the scholar's courses of universities, classifying the fire inspector qualification course (executed by National Emergency Management Agency) in five stages, and opening the fire inspector qualification test to the public.

Analysis on Chemical Accident Characteristics of Facilities Handling Hydrochloric Acid (염산 취급시설 화학사고 특성분석에 관한 연구)

  • Shin, Chang-Hyun;Lee, Hyun-Seung;Kim, Tae-Hong;Park, Jai Hak
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.14-22
    • /
    • 2016
  • This study analyzed the chemical accidents of hydrochloric acid which is the most frequent chemical in order to make safety management improvement plans. 28 Cases have occurred for the last 4 years, 8 cases of which were casualty accidents, and more efficient plans are needed to minimize the accidents. For this purpose, this study investigated the problems through yearly statistics of the chemical accidents, and suggested appropriate measures of facility management, safety culture and management plans. It is important for businesses to make and implement the improvement measures according to time schedule.

Research and Analysis of the Causes and Preventive Measures of Fires Caused by a Disposable Gas Lighter (1회용 가스라이터로 인한 화재 원인과 예방대책의 조사·분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • This study analyzed the regulatory actions of disposal gas lighters as well as the situations, causes, and preventive measures of fires, and accidents caused by disposal gas lighters. Since child-resistant lighters became mandatory, the percentage of fires caused by playing with fire has decreased in Korea as it did in America and Japan. Fires caused by disposal gas lighters can occur by afterburning, unintentional lighting, large flames, or explosion or bursting as well as by arson and playing with fire. This study suggests the preventive measures of fires caused by disposal gas lighters as follows: Taking a step not to be used as child's tool for playing with fire, the warning of fire cases caused by afterburning, warning of the dangers of leaving disposal gas lighters on the car dashboard or high temperature places, improving the protective synthetic resin cover of the stop part of a vehicle seat rail, and providing information on precautions for keeping in drawers or disposition methods.

A Study on the ways to minimize Casualties through a consideration of the CO gas generated during combustion (연소시 생성된 CO가스의 고찰을 통한 인명피해 최소화 방안에 관한 연구)

  • Choi, Man-Chul;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.133-140
    • /
    • 2013
  • Recently developed a variety of architectural interior decoration according hwadoeme type of toxic gases generated during fire also are becoming diversified, resulting in fatal casualties occurred in the trend is also being increased. During a fire, toxic gas that is generated varies depending on the combustible material occurs. However, all combustible materials, including carbon, incomplete combustion of carbon monoxide which is generated in the most common toxic gases can be seen as one. Accordingly, in this study of organic solids that are generated in case of fire toxic gases, and briefly discuss the characteristics of the risks and, by far the most common Co gas for measures to prevent human casualties, seolbijeok, the temperature dependence, divided into four aspects of administrative daechaekdeung explained.

A Study on the Precautions Effects of the Enclosure Integrity Test for the Gaseous Extinguishing Systems: Focusing on the Power Plant (가스계 소화설비의 밀폐도 시험에 영향을 미치는 사전조치에 관한 연구: 발전소를 중심으로)

  • Kim, Young-Chul;Jo, Il-Hyun;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • The present study was aimed to analyze enclosure integrity test, which is the performance experiment of soaking time, in a fire zone equipped with gaseous extinguishing system in an effort to find understand the effect of precaution factors upon the success of fire extinguishment. To achieve the goal of this study, it divided the fire zones of internal and external power plants into ones taking precaution measures and not taking them and then enclosure integrity test was given respectively. Therefore, this study examined the success rate if the test according to the presence and absence of the precaution measure and confirmed the failure factors, designed concentration soaking time and proportion of leakage area to total volume area by type of gaseous extinguishing system and rooms. Precaution measures were applied to the fire zones without them to confirm the increase of the success rate of enclosure integrity test. By doing so, it was found that reduced number of experiments caused by failure led to cost saving.

Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant (BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책)

  • Woo, In-Sung;Lee, Joong-Hee;Lee, In-Bok;Chon, Young-Woo;Park, Hee-Chul;Hwang, Seong-Min;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.22-28
    • /
    • 2012
  • For a methanol separation column of the BPA (Bisphenol A) plant, HAZOP (hazard and operability) assessment was performed and damage ranges were predicted from the accident scenarios for the fire and the explosion. As a result, the damage range of the jet fire was 20 m in the case of rupture of the discharge pipe (50 mm diameter) of safety valve, and that of the flash fire was 267 m in the case of catastrophic rupture. Also, the damage ranges of the unconfined vapor cloud explosion (UVCE) for the rupture of the discharge pipe and for the catastrophic rupture were 22 m and 542 m, respectively. For the worst case of release scenarios, safety measures were suggested as follows: the pressure instruments, which can detect abnormal rise of the internal pressure in the methanol separation column, should be installed by the 2 out of 3 voting method in the top section of the column. Through the detection, the instruments should simultaneously shut down the control and the emergency shut-off valves.

A Study on the Fire Risk of ESS through Fire Status and Field Investigation (화재현황 및 현장조사를 통한 ESS의 화재 위험성 연구)

  • Park, Kwang-Muk;Kim, Jae-Hyun;Park, Jin-Yeong;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.91-99
    • /
    • 2018
  • Recently, the spread of ESS in Korea has increased and a fire accident has also occurred. By July 2018, there were a total of 7 cases. All 7 cases were ESS systems consisting of lithium-ion batteries and were burned down. Both the automatic fire extinguisher and the fire department were not able to digest. In this paper, the characteristics of ESS fire are analyzed based on recent ESS fire situation and field investigation, and the cause of fire is divided into environmental, electrical and thermal factors. As a result, it was found that the ESS fire was correlated with the installation environment of the system. In the domestic and overseas lithium ion battery test standard and ESS facility standard survey, the trends and differences of domestic and overseas facilities standards were identified. Based on the fire status and field investigationy, and domestic and overseas facility standard survey, measures were suggested to prevent and prevent the spread of fire in ESS fire.

A Study on Railway Safety Index for the Safety Management (철도안전관리를 위한 안전지표 선정에 관한 연구)

  • Kwak, Sang-Log;Wang, Jong-Bae;Cho, Yun-Ok;Park, Chan-Woo
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1053-1058
    • /
    • 2006
  • Many railway safety measures reduce railway fatalities into half for last 10 years. But more improvement in railway safety is required to meet the social need after railway fire accident in Daegue. Reasonable railway safety index is needed to find out the weak point and efficiencies of various safety measures. But we still have only 2 kinds of safety index which are set for 10 years ago. In order to derive guideline for setting up safety index, we analyze accident cause, previous studies for railway safety improvement in Korea, and other countries safety plan. As a result some proposal for safety index was driven in this study.

  • PDF

Fire due to an important national cultural protection measures research (화재로 인한 국가 중요 문화재 보호대책 연구)

  • Lee, Jeong-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.485-500
    • /
    • 2013
  • Cultural assets of the country's history and cherish the living conditions of the people, conscious and cohesive crystals, and the pride of the hearts of the people as a haven. In the country worth preserving national treasure, bomulgeup, local cultural heritage as a major cultural property protection are. Cultural properties, etc. Most are wooden, is vulnerable to fire, and, moreover battling to far away from the city and due to the geographical conditions are very challenging aspects. The national cultural assets, such as the many temples, vows to fire one if the loss of a centuries-old cultural property is a big loss of national posterity to great shame is not. Still cultural assets and a large number of visitors have flocked temples. All of us to keep the look and feel of the cultural assets pleasure to conserve cultural assets preserved to ensure that fire prevention is always unmistakably bear in mind that sees.

  • PDF

Namsan 1.2.3 Tunnel accident disaster countermeasures (남산 1·2·3호 터널사고에 대한 재난대응방안)

  • Lee, Jeong-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • Namsan road are taxis in the engine room fires (07/14/2011 18:05) in the tunnel, and the driver of the vehicle was 100 passenger car and more than 500 evacuated were disasters. Pole road vehicles within the tunnel if there is a fire tunnel fire occurred at a two-way evacuation difficult and rapid evacuation is difficult and mass casualties are concerned, the number of casualties is feared. In this study, by considering the problems and improve the Namsan 1,2,3 Tunnel In case of fire, the best disaster response is to come up with ways.