• Title/Summary/Keyword: Fire Risks

Search Result 193, Processing Time 0.029 seconds

화학공장의 안전성 평가에 관한 고찰

  • Park, Chang-Bok
    • Fire Protection Technology
    • /
    • s.16
    • /
    • pp.28-40
    • /
    • 1994
  • This objective of safety assessment is to determine the acceptability of risks of hazards, or the coping measures, if not acceptable, by identifying and quantifying the risks potentially involved in incidents, with the information of new technology and the disasterous cases.

  • PDF

A COMPUTER SIMULATION MODEL AS A MEANS OF EMERGENCY EVACUATION TRAINING FOR CONSTRUCTION PROJECTS

  • Chung-Suk Cho;Dong-Cheol Shin
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.864-868
    • /
    • 2009
  • Fire safety management on any construction site should start with recognizing fire risks in the workplace, understanding the extent of the risks, and proper assessment of the controls necessary to reduce the risks. However, the most important step to prevent fire-related accidents on jobsites is the constant review and monitoring of processes and controls by all individuals involved. This study was conducted to analyze the effectiveness of using computer simulation as an addition to maps or floor plans in safety training and management. Simulex was used on a real project to model various egress routes and to identify potential problem areas of the evacuation strategy. This study highlights the efficacy of simulated emergency evacuation as a training tool that visually shows constantly altering means of egress.

  • PDF

Experimental Study on the Explosion and Fire Risks of Mobile Phone Batteries (휴대폰 배터리의 폭발 및 화재 위험성에 관한 실험적 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.111-120
    • /
    • 2016
  • This is an experimental study to analyze the explosion and fire hazards of mobile phone batteries. Using the lithium-ion batteries currently used on smart phone as the experiment samples, the experiments were conducted by overcharging, internal and external short circuit, and thermal shock with the potential of explosion and fire caused by careless use or abnormal conditions. The experiment results showed that, in the case of overcharging and external short circuit, there was no explosion and fire hazard in the normal operation of the protection circuit module (PCM), but there were big risks when the PCM faulted conditions were assumed. In the case of the experiments by internal short circuit and thermal shock, such risks varied depending on a battery charge state. In other words, it could be verified that there were low risks of explosion and fire in a full discharge state, but there were high risks in a full charge state. These experiment results suggest that to minimize the explosion and fire hazards of mobile phone batteries, an alarm device is necessary when the PCM fault occurs. In addition, a solid battery case should be made and safety equipment, such as a cooling device to avoid high temperature, is needed.

Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current (고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구)

  • Sim, Sang-Bo;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.114-122
    • /
    • 2016
  • This study is to analyze the explosion and fire risks due to high temperature and short circuit current of Lithium batteries. This study selected the typical types of Li-polymer batteries and Li-ion batteries as the test samples. The result of explosion risk assessment due to the high temperature showed that, while a Li-polymer battery had $170^{\circ}C$ explosion on average, a Li-ion battery had $187^{\circ}C$ explosion. The measurement result of temperature increase due to short circuit current revealed that, in case that protection circuit module (PCM) was normally working, there was little of temperature increase due to over-current limitation. However, in case that PCM was out of order, the temperature of a Li-polymer battery increased up to an average of $115.7^{\circ}C$ and the temperature of a Li-ion battery increased up to an average of $80.5^{\circ}C$, which showed the higher risks of fire and burn.

Research on Disaster and Fire Response Capability and Hazard Analysis Using Basic Mapping Method (Mapping을 이용한 소방방재력 및 재해취약성의 연구)

  • Wang, Soon-Joo;Baek, Min-Ho
    • Journal of the Society of Disaster Information
    • /
    • v.3 no.1
    • /
    • pp.69-86
    • /
    • 2007
  • The fire department has one of the most important role as public resources of response to disasters in the aspect of supply and the adequate distribution of resources of response is essential, but the distribution of the response capability to disaster of fire department does not reflect the regional hazard vulnerability and hazard risks. Researchers performed database process with simple mapping based on the regional fire disaster response capability and the regional hazard vulnerability and hazard risks. The cities and towns are divided to four types each, total eight types and relative threat ratios are extracted from every type. The fire disaster response capability was extracted from number of firemen and fire vehicles in defined region. The distribution of the fire disaster response capability was inadequate and not matching to relative threat especially in small cities and some types of towns. The regional relative threat and resources should be analyzed by more delicate mapping and software development in the future.

  • PDF

Recognition of scene activity risks among the firefighters (소방공무원의 현장 활동 위험도 인식)

  • Kim, Jong-Seo;Seong, Dong-Won;Hyeon, Seong-Min;Gal, Won-Mo;Lee, Dong-Ho;Park, Jong-Tae
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.105-111
    • /
    • 2013
  • This study aimed to identify the recognition of fire risks on their field operations among firefighters and contribute to setting up safety measures accordingly. A self-administered questionnaire were used to evaluate their recognition of job risks. About 93.4% of respondents answered they have exposed to job risks and 73.4% answered that they had high safety awareness. Our study showed that the lower service years and ranks the fire officers had, the lower relevance in statistics their awareness of the risk of the field operations and safety concerns had. The vulnerable group is those aged 20 to 39, with under 10 years of service, at a lower rank of senior fire sergeant. The study suggests coming up with the measures to motivate the officers to perform safe operations by improving their safety awareness.

Analysis of Fire Scenarios and Evaluation of Risks that might Occur in Operation Stage of CAES Storage Cavern (CAES 저장 공동 운영단계에서 발생 가능한 리스크 평가 및 화재 시나리오 분석)

  • Yoon, Yong-Kyun;Ju, Eun-Hye;Seo, Saem-Mul;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.25 no.1
    • /
    • pp.107-114
    • /
    • 2015
  • This study focuses on assessing risks which might occur in operation stage of CAES storage cavern and analyzing fire scenarios for the risk that have been assessed with highest risk level. Risks in operation stage were categorized into upper risk group and lower risk group. Components of upper risk group are technical risk, facility risk and natural disaster risk. Lower risk group is composed of 11 sub-risks. 20 experts were chosen to survey questionnaires. ANP model was applied to analyze the relative importance of 11 sub-risks. Results of risk analysis were compared with risk criterion to set risk priorities, and the highest risk was determined to be 'occurrence of the fire within the management opening'. Three fire scenarios were developed for the highest risk level and FDS (Fire dynamics Simulator) was used to analyze these scenarios. No. 3 scenario which air blows from tunnel into outside atmosphere represented that a rate of smoke spread was the fastest among three fire scenarios and a smoke descended most quickly below the limit line of breathing. Thus, No. 3 scenario turned out to be the most unfavorable condition when operating staffs were evacuated from access tunnel.

A Study on Risk Evaluation and Classification of Fire Equipments for Certification (소방용품의 강제인증을 위한 위험도평가 및 품목분류에 관한 연구)

  • Choi, Gi-Heung
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.7-12
    • /
    • 2009
  • This study focuses on the classification of fire equipments for certification based on the risk evaluation. In general, known statistics on fire equipment-related accidents needs to be used for risk evaluation. When statistics is not available, however, expected frequency and severity of accident for individual equipment can be taken into account in evaluating the related risks. Based on the level of inherent risks, each equipment is then classified into three categories for certification. For equipments that risk evaluation is not possible, characteristics of those products such as reliability are considered for classification. Once classified, each equipment is assigned an appropriate certification module.

전자공업에서의 위험과 대책(1)

  • Yu, Jae-Hwan
    • Fire Protection Technology
    • /
    • s.13
    • /
    • pp.27-37
    • /
    • 1992
  • As the progress in electronic industry is very rapid, various materials are used in this area and it is very difficult to find the hazard of those materials. Also expensive equipments are concentrated and flammable liguids or toxic gases are used in the procsses, the possibility of loss in the fire is very high. So it is very important to analyze various risks and take the proper measures.

  • PDF