• Title/Summary/Keyword: Fire Inspection

Search Result 300, Processing Time 0.028 seconds

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

The Characteristics of Tongue Inspection and Relationship between Tongue Inspection and Differenitiation of Syndrome (중풍초기환자의 설상(舌象) 분포와 변증의 유용성에 관한 임상고찰)

  • Choi, Dong-Jun;Park, Sung-Uk;Moon, Sang-Kwan;Joh, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.20 no.2
    • /
    • pp.187-197
    • /
    • 1999
  • To assess the usefulness of tongue inspection for evaluating the Pattern identification in oriental medicine, we observed stroke patient's tongue and tongue coat and compared it with Pattern identification. The test group was composed of 85 acute stroke stage patients(within 72 hours of onset). Subjects were randomly selected from stroke patients admitted in the KyungHee University, Hospital of Oriental Medicine from December 1 1998 to June 30 1999. We took pictures of patient's tongue and tongue coat within 72hours from onset and checked Pattern identification at the same time. Tongues colored pale rose or red greatly outnumbered other colors. Tongue shape tended to be prickly or fissured, and tongue condition tended to be unflexible or deviated. Regarding tongue coat color, there were great amounts of yellow or clark yellow tongue coats, which were moist, thick or greasy in substance. The red tongue was significantly related to Fire-heat and deficiency of Yin syndrome, while faint white tongue to Damp syndrome(P=0.006). In terms of tongue coat, thin coat was related to Wind and Fire-heat syndromes, thick coat to Damp and Blood stasis syndrome, respectively (P=0.002). In conclusion, we thought that tongue inspection could be a useful Oriental medicine diagnosis in stroke.

  • PDF

A Study on the Fire Risk of the Kimchi Refrigerator through Case Analysis of Fire Accidents (사례 분석을 통한 김치냉장고의 화재 위험성에 관한 연구)

  • Park, Nam Kyu;Ji, Hong Keun;Song, Jae Yong
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • In this paper, we describe fire risk of Kimchi refrigerator. The Kimchi refrigerator has been widely spread and used starting from the first half of 2000 and recently fire accidents caused by the Kimchi refrigerator emerged as social concern. In particular, in products of a specific manufacturer, it is not an environmental factor, but a characteristic that the fire is caused due to a defect of the product itself is shown. These features are judged to be formed by unique defects regardless of external factor by forming electrically arc mark in the relay element. In this paper, we analyzed the cause of the fire occurring in the Kimchi refrigerator and finally confirmed the characteristic that the fire occurred mainly in the relay element due to insufficient capacity of the relay element. Therefore, when a fire occurs in a product of the same maker as the Kimchi refrigerator mentioned in this paper, it is always judged that the inspection of the relay element should be carried out.

Condition assessment of fire affected reinforced concrete shear wall building - A case study

  • Mistri, Abhijit;Pa, Robin Davis;Sarkar, Pradip
    • Advances in concrete construction
    • /
    • v.4 no.2
    • /
    • pp.89-105
    • /
    • 2016
  • The post - fire investigation is conducted on a fire-affected reinforced concrete shear wall building to ascertain the level of its strength degradation due to the fire incident. Fire incident took place in a three-storey building made of reinforced concrete shear wall and roof with operating floors made of steel beams and chequered plates. The usage of the building is to handle explosives. Elevated temperature during the fire is estimated to be $350^{\circ}C$ based on visual inspection. Destructive (core extraction) and non-destructive (rebound hammer and ultrasonic pulse velocity) tests are conducted to evaluate the concrete strength. X-ray diffraction (XRD) and Field Emission Scanning Electron Microscopy (FESEM) are used for analyzing micro structural changes of the concrete due to fire. Tests are conducted for concrete walls and roof slab on both burnt and unburnt locations. The analysis of test results reveals no significant degradation of the building after the fire which signifies that the structure can be used with full expectancy of performance for the remaining service life. This document can be used as a reference for future forensic investigations of similar fire affected concrete structures.

Spalling Reduction Methods of Ultra High-Strength Reinforced Concrete Columns (초고강도 콘크리트 기둥의 폭렬저감방안에 관한 실험적 연구)

  • Shin, Sung-Woo;Yoo, Suk-Hyeong;Kim, In-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.171-178
    • /
    • 2006
  • It was presented that the spalling of high strength concrete exposed to high temperature could be reduced by using polypropylene fiber. However, as the concrete strength increase, the demanded quantity of PP fiber increase and this results in the loss of workability of ultra high strength concrete. The silica fume which is essentially mixed in ultra high strength concrete decrease the permeability of concrete, and this will increase the degree of spalling. In this study the effect of silica fume on the spalling of ultra high strength concrete and the fire resisting efficiency of PP fiber and poly vinyl alchol, instead of PP fiber, for the security of workability were experimentally examined.

Case Study on Prevention of Fire/Explosion Accidents caused by Chemical Substances in Small/Medium Sized Construction Sites (중소규모 건설현장 화학물질로 인한 화재·폭발 재해예방 사례연구)

  • Shin, Woonchul;Kwon, Jun Hyuk;Lee, Yong Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.63-70
    • /
    • 2014
  • There has been an increase in fire/explosion accidents caused by chemical substances used in new small/medium sized construction, reconstruction, or extension sites. There is vast room for improvement, especially in safety training, safety inspection, and selection of countermeasures because training, technicality, and management systems regarding fire/explosion risks in small/medium sized construction sites are very immature in most cases. The purpose of this study is to propose a differentiated technical, educational, and management application plan for preventative management of fire/explosion accidents caused by chemical substances used in small/medium sized construction sites.

Study for Binary Liquid Type Fire Retardant White Paint of Polyurethane Lacquer (저연기성 이액형 방염우레탄락카 백색도료 연구)

  • Kwon, Kyungok
    • Applied Chemistry for Engineering
    • /
    • v.18 no.5
    • /
    • pp.527-530
    • /
    • 2007
  • The binary liquid type fire retardant paint of polyurethane (alkyd resin) lacquer is developed to cover the defect of one liquid type white paint of chlorinated rubber used generally but which has weak surface and poor adhesive strength to the wood as well as generating much black smoke when it is firing. The properties of the composition of binary liquid type of white paint of polyurethane lacquer developed in this study for using to wood has shown that the better suppressed smoke generation and enhanced the adhesive strength to the wood than that of fire retardant white paint used.

A Study on the Development of Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector (차동식열감지기 현장점검용기기 개발에 관한 연구)

  • Kim, Shi-Kuk;Lee, Chun-Ha;Jee, Seung-Wook;Yuk, Hyun-Dai;Yang, Seung-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.200-209
    • /
    • 2009
  • 본 논문은 차동식스포트형열감지기 현장점검용기기 개발에 관한 연구이다. 현재 소방점검 시 차동식스포트형열감지기의 성능확인을 위해 사용되는 점검기기(4 Type)들을 실험대상으로 선정하여 문제점을 찾고, 도출된 문제점을 바탕으로 감지기 형식승인 시 감도시험기준 조건과 동일한 온도조건인 주위온도 대비 30$^{\circ}C$ 높은 온도로 자동설정 할 수 있는 기능과 그 온도를 계속 유지할 수 있는 기능을 갖춘 새로운 차동식스포트형열감지기 현장점검용 기기의 시제품을 제작하고 그 성능을 확인하였다.

  • PDF

The Flame and Distributed Temperature Restraint Properties of Fire Venetian Blind Louver in Buildings (차양식 방화루버의 화염 및 온도 전파 억제 특성)

  • Chae, Young-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.120-127
    • /
    • 2015
  • The purpose of this study is to improve the fire prevention performance using the fire venetian blind louver subjected to burning by fire flame. The investigation is based on testing 2 full scale specimens, which is $3m{\times}3m$ module, $850mm{\times}1,500mm$ open, and $900mm{\times}900mm{\times}175mm$ venetian blind louver. Two louver thickness (1.5 and 2.0mm) were adopted. The specimens were exposed to fire flame temperature levels of ISO834 at the lower surface of the fire venetian blind louver specimens with exposure duration of one hour in Korea Institute of Construction Technology (KICT). It was found from the test results that the values of distributed temperature, decreased for all specimens for protecting to fire flame by venetian blind louver. The results of tests were a good fire prevention performance between in initial to 6 mins. At 60 minutes around ISO 834 fire loading, the percentages of distributed temperature in 500mm and 800mm height ranged between 11 and 10% respectively, regardless of louver thickness. This study, therefore, will improve the fire venetian blind louver for fire protection and prevention performance.

Impact of Fire Demand on Fire Service Budget (소방수요가 소방예산에 미치는 영향)

  • Lee, Wonjoo;Lim, Jae Hoon;Moon, Kwang Min
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.125-134
    • /
    • 2020
  • This paper aimed to statistically analyze the impact of fire needs not considered in previous reports based on preventive and preparedness strategies of fire administration and fire budget.. The panel data came from 16 metropolitan councils from 2008 to 2018 and was statistically analyzed based on the preventive measures of the fire administration (agreement for building permission, specific target for fire-fighting, public use facilities, and special fire inspection [SFI]), preparedness of the fire administration (fire safety education [FSE]), response of the fire administration (mobilization for fire suppression [MFS] and mobilization for ambulance service [MAS]), and fire budget. In the results, SFI, FSE, and MFS had a significant negative influence on the fire budget. Meanwhile, MAS had a significant positive effect on the fire budget (p < 0.01). These results reflect public policy in Korea; there has been a paradigm shift in fire administration: from disaster acceptance (focusing on recovery) to disaster response (focusing on field response) to disaster preparedness (focusing on preparedness).