• 제목/요약/키워드: Fire Hazard Assessment

검색결과 109건 처리시간 0.022초

Evaluation of Evacuation Safety in University Libraries Based on Pathfinder

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.237-246
    • /
    • 2024
  • In recent years, the frequent occurrence of fire accidents in university libraries has posed significant threats to the safety of students' lives and property, alongside negative social impacts. Accurately analyzing the factors affecting evacuation during library fires and proposing optimized measures for safe evacuation is thus crucial. This paper utilizes a specific university library as a case study, simulating fire evacuation scenarios using the Pathfinder software, to assess and validate evacuation strategies and propose relevant optimizations. Pathfinder, developed by Thunderhead Engineering in the United States, is an intuitive and straightforward personnel emergency evacuation assessment system, offering advanced visualization interfaces and 3D animation effects. This study aims to construct evacuation models and perform simulation analysis for the selected university library using Pathfinder. The library's structural layout, people flow characteristics, and the nature of fire and smoke spread are considered in the analysis. Additionally, evacuation scenarios involving different fire outbreak locations and the status of emergency exits are examined. The findings underscore the importance of effective evacuation in fire situations, highlighting how environmental conditions, individual characteristics, and behavioral patterns significantly influence evacuation efficiency. Through these investigations, the study enhances understanding and optimization of evacuation strategies in fire scenarios, thereby improving safety and efficiency. The research not only provides concrete and practical guidelines for building design, management, and emergency response planning in libraries but also offers valuable insights for the design and management of effective evacuation systems in buildings, crucial for ensuring occupant safety and minimizing loss of life in potential hazard situations

대도시 위해.위험시설에 대한 안전도 수용기준 정립에 관한 연구 (Study on the Establishment of a Safety Allowance Level of Disastrous and Hazardous Facilities in Large Cities)

  • 고재선;윤명오
    • 한국화재소방학회논문지
    • /
    • 제15권1호
    • /
    • pp.84-92
    • /
    • 2001
  • 현대 사회에 있어서 인구 과밀화와 더불어 대도시의 사회기반시설(SOC)증가에 따른 화학물질 사용시설의 중대사고의 경향이 높아져 가고 있다. 기존 위해·위험시설의 안전사고의 문제점과 더불어 신규 위해·위험시설물의 증가에 따른 안전사고의 심각성을 낮추기 위해 필요한 노력을 하지 않으면 안된다. 선진국에서는 산업시설 그리고 지역사회의 전문위원회가 잠재적인 위해 산업의 사고에 대한 off site 및 on site의 피해 심각성에 대한 평가와 이에 대한 적절한 조언 및 대책을 강구하고 있다. 따라서 본 연구에서는 국내의 위해·위험시설에 대한 안전도 수용기준 성립을 위하여 첫째, 영국 HSE(Heath & Safety Executive)의 QRA(Quantified Risk Assessment)와 Matrix of Risk of Evaluated Sources of Hazard를 적용한 사회적 위험성 평가 방법과 둘째, FTA(Fault Tree Analysis) 또는 ETA(Event Tree Analysis) 등 정량적인 사고 발생 확률과 시뮬레이션 및 계산식을 통해 국내 임의의 지역에 대하여(서울시 위해·위험시설)사고 피해 정도의 개인적 위험성을 평가, 적용함으로서 기존 시설 또는 신설 부지 개발을 위한 제한시 포괄적 안전도 수용기준(수용가능성) 여부를 판별하고자 한다.

  • PDF

30 MeV 사이클로트론 시설 위험성 평가 (Risk Assessment of 30 MeV Cyclotron Facilities)

  • 정교성;김종일;이진우
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.39-45
    • /
    • 2017
  • A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce $^{18}F$, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fires and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a fire. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.

Limonene - Expanded Polystyrene 혼합물의 자연발화 특성 (Autoignition Characteristics of Limonene - Expanded Polystyrene Mixture)

  • 송영호;하동명;정국삼
    • 한국화재소방학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2004
  • 감용제 limonene을 이용하는 EPS 자원 재활용 공정에 있어서, limonene - EPS 혼합 액체의 저장$.$취급시의 화재위험성 평가에 대한 기초 자료로 제시하고자 혼합물의 농도 및 시료양의 변화에 따른 최저발화온도를 측정하였고, 발화와 비발화 영역을 비교하였다. 발화온도를 예측하는데 있어서 가장 과학적인 원리로서 이용되고 있는 발화 지연 시간, 활성화 에너지 및 발화온도의 관계식을 선형회귀분석을 이용하여 ln t = 0.704/T-5.819로서 제시하였다. 또, 가연성 혼합물의 농도 변화에 따른 발화위험성을 예측하기 위하여 혼합물의 농도와 발화온도의 관계식을 비선형회귀분석을 이용하여 $T_m=248.32+69.27X+172.60X^2$로서 제시하였다. 그 결과, 발화 지연 시간과 발화온도와의 관계식 및 혼합물의 농도와 발화온도와의 관계식에 의해서 limonene - EPS 혼합물의 발화온도의 추정이 가능하게 되었다.

재생에너지 기반 알칼라인 수전해 장치(2 Nm3/hr) 위험요인 고찰 (A Study on Hazard of Renewable Energy based Alkaline Water Exectrolysis Equipment)

  • 김현기;서두현;김태훈;이광원;이동민;신단비
    • 한국수소및신에너지학회논문집
    • /
    • 제33권1호
    • /
    • pp.55-60
    • /
    • 2022
  • As interest in sustainable and eco-friendly energy sources is increasing due to various problems in the carbon society, a hydrogen economy using hydrogen as a main energy source is emerging. While the natural gas reforming method generates carbon dioxide, the water electrolysis method based on renewable energy is eco-friendly. The water electrolysis device currently being developed uses a 2 Nm3/hr class alkaline aqueous solution as an electrolyte and produces hydrogen based on renewable energy. In this study, risk assessment was conducted for these water electrolysis devices

HAZOP을 통한 해양플랜트 흡착식 탈수공정 패키지의 위험성평가 및 안전도 향상 방안 (A Case Study on the Risk Assessment for Offshore Plant Solid Desiccant Dehydration Package by using HAZOP)

  • 노현정;박상현;조수길;강관구;김형우
    • 한국산업융합학회 논문집
    • /
    • 제23권4_2호
    • /
    • pp.569-581
    • /
    • 2020
  • Since the dehydration packages of offshore plant deal directly with oil & gas, there is a great risk of fire and explosion during operation. Therefore, this study performed risk assessment through HAZard & OPerability (HAZOP) for solid desiccant dehydration package that can remove water component of natural gas in offshore floating liquefied natural gas (LNG) production facilities below 0.1 ppmv. The risk matrix was determined by dividing the likelihood and the severity into five levels separately by asset, life, environment and reputation. The piping & instrumentation diagram (P&ID) of the dehydration package was divided into 9 nodes. Total 22 deviations were assessed in consideration of the adsorption and desorption conversion cycle. A risk assessment based on deviations revealed 14 major hazards. Three representative types of hazards were open/close failure of the control valve, control failure of the heater, and abnormal operation of the regeneration gas cooler. Finally, we proposed the installation of additional safety devices to improve safety against these major hazards, such as safety instrumented functions, alarms, etc.

체크리스트 기법을 이용한 국내 주요사찰의 정성적 산불위험성 평가 방법 (Method of Qualitative Hazard Assessment of Forest Fire for the Major Temple in Domestic Using by Checklist)

  • 김동현;이지희;이명선;김광일
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.432-435
    • /
    • 2011
  • 산불로 인한 피해는 비단 산림뿐만 아니라 산림인접지 가옥, 사찰과 같은 건축물에서도 발생된다. 특히, 사찰은 국보뿐만 아니라 다양한 문화재를 보유하고 있어 산불로 인해 소실될 경우 문화 자산의 피해가 불가피하다. 이에 국보보유사찰, 문화재 다량보유사찰, 조계종 교구 본사, 세계문화재 등재 사찰 등을 포함한 우리나라 주요사찰 42개소에 대해 미국 Firewise 및 캐나다의 Firesmart에서 제시한 산림인접지 시설물의 위험성 평가 방법을 기반으로 체크리스트 기법을 이용하여 '사찰 산불 위험성 평가'를 실시하였다. 체크리스트 주요 항목은 크게 입지 여건, 임상 및 산림과 사찰의 이격거리, 산불발생 개연성, 사찰 주변 가연물 화재위험성, 적정소방시설 여부, 기타 화재방지를 위한 시설물 평가 등 총 6개 항목으로 구분하여 26개 세부항목을 작성, 평가하였다. 정성적 위험성 평가 결과, 산불로 인한 화재 위험성이 높은 사찰과 산불피해 저감 대책을 제시하였고 향후, 정량적 위험성 평가를 통한 위험관리 모델 제시에 관한 연구를 수행하고자 한다.

  • PDF

금속분말-난연제 함유 ABS의 난연 특성 평가 (Assessment of Flame Retardancy for Acrylonitrile Butadiene Styrene Containing Metal Powder and Flame Retardant)

  • 송영호;정국삼
    • 한국화재소방학회논문지
    • /
    • 제21권2호
    • /
    • pp.30-35
    • /
    • 2007
  • 고분자 물질의 화재 위험성 및 화재시 인명 피해의 감소를 위한 기초자료로 제시하고자 난연제 및 금속분말의 첨가에 의한 난연성 평가를 수행하였다. 본 연구를 위하여 중량감소율,한계산소지수 및 탄화층 생성량 측정, 연기 중량 농도 및 일산화탄소 발생량 측정의 실험을 수행하였다. 금속분말과 난연제를 함유한 acrylonitrile butadiene styrene은 낮은 중량감소율을 나타내었고, 한계산소지수 및 탄화충 생성량은 증가하였으며, 연기 중량 농도 및 일산화탄소의 발생량도 감소하는 결과를 나타내었다. 또한 가장 효과적인 복합체는 tricresyl phosphate-Mo 복합체로 나타났다.

붕소/실리콘 졸 화합물로 도포된 편백 목재의 연기유해성 평가 (Smoke Hazard Assessment of Cypress Wood Coated with Boron/Silicon Sol Compounds)

  • 진의;정영진
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.1-10
    • /
    • 2020
  • 본 연구는 건축 및 내구재용 목재인 편백 목재에 붕소/실리콘 졸 화합물을 처리한 후 화재위험성을 연기 유해성에 대하여 연기성능지수(SPI), 연기성장지수(SGI)와 연기강도(SI)를 중심으로 조사하였다. 화합물은 Tetraethoxyorthosilicate를 Boronic acid와 Boric acid 유도체와 반응시켜 합성하였다. 연기 특성은 편백목재에 대하여 Cone calorimeter (ISO 5660-1) 장비를 이용하여 조사하였다. 화재강도는 50 kW/㎡의 외부 열 유속(External heat flux)으로 고정시켰다. 연소 반응 후 측정된 연기성능지수는 편백목재와 비교하여 13.4~126.7% 증가하였다. 연기성능지수에 의한 화재위험성은 편백목재, PBA/Si, IBBA/Si, BA/Si 순서로 감소하였다. 연기성장지수는 편백목재와 비교하여 12.0~57.5% 감소하였다. 연기성장지수에 의한 화재위험성은 편백목재, PBA/Si, IBBA/Si, BA/Si 순서로 낮아졌다. 연기강도에 의한 화재위험성은 3.2~57.8% 감소하였으며 편백목재, PBA/Si, IBBA/Si, BA/Si 순서로 낮아졌다. COpeak 농도는 85~93 ppm였으며 공시편과 비교하여 37~43% 감소하였다. 화재위험성을 연기유해성에 대해 종합적으로 평가하면 편백목재, PBA/Si, IBBA/Si, BA/Si순서로 낮아졌다.

소나무, 굴참나무 낙엽의 연소 방출가스 분석 및 건강 위험성 평가 (Combustion Emission Gas Analysis and Health Hazard Assessment about P. densiflora and Q. variabilis Surface Fuel Beds)

  • 김동현;김응식;이명보
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.24-31
    • /
    • 2009
  • 본 연구에서는 우리나라 주요 침엽수종인 소나무(Pinus densiflora)와 활엽수종인 굴참나무(Quercus variabilis)의 낙엽에 대해 FTIR(Fourier Transform Infrared) 분광계를 이용하여 배출 연소가스 종류 및 농도를 측정하였다. 실험결과 소나무와 굴참나무 낙엽에서 Carbon monoxide, Carbon dioxide, Acetic acid, Butyl acetate, Ethylene, Methane, Methanol, Nitrogen dioxide, Ammonia, Hydrogen Fluoride, Sulfur dioxide, Hydrogen bromide 등 13개 연소가스가 검출되었고 굴참나무 낙엽에서는 Nitrogen monoxide가 추가로 검출되었다. 방출된 연소가스의 전체 농도는 소나무 낙엽이 굴참나무 낙엽에 비해 4.5배 많이 검출되었다. 특히, 시간가중평균가스농도(Time-Weighted Average, TWA, ppm) 기준을 초과하는 연소가스는 Carbon monoxide, Carbon dioxide, Butyl acetate가 검출되었고 단시간노출기준(Short Term Exposure Limit, STEL, ppm) 기준을 초과하는 연소가스는 Carbon monoxide, Carbon dioxide로 소나무 및 굴참나무 모두에서 나타났다. 이에 산불에서의 낙엽의 지표화 연소시 전체 가스 방출량의 99% 이상을 차지하고 있는 Carbon monoxide, Carbon dioxide의 건강 위험성이 높은 것으로 나타났다.