• 제목/요약/키워드: Fire Extinguishing

검색결과 391건 처리시간 0.022초

미세 물분무를 이용한 객차내의 화재제어 성능시험 (Performance Tests of Fire Control Using Water Mist in a Coach)

  • 김동현;박원희;장용준;이한수;유홍선;강중구;박정렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1814-1818
    • /
    • 2007
  • The Korea Railroad Research Institute developed a fire control system for coaches using water mist. The fire control technology using water mist is used in the fire control system embedded in coaches developed through research. Such environment-friendly, automatic fire-extinguishing device is also economical because the amount used is significantly less than that of the existing sprinkler system. The paper introduces the developed fire control system and fire control performance tests using such system.

  • PDF

소형항공기의 화재방지 요건 및 시험에 관한 연구 (A Study on Fire Prevention Requirements and Tests for Small Aircraft)

  • 유승우;진영권
    • 항공우주시스템공학회지
    • /
    • 제5권1호
    • /
    • pp.7-12
    • /
    • 2011
  • The goal of fire prevention research is to eliminate fires as a cause of fatal accidents and there are two main areas of research. One is to prevent flame propagation during in-flight and it addresses fire hazards. The other is to minimize the possibility of flame penetration or fuselage burn-through and it aims toward post-crash survival include crash protection, emergency evacuation and post-evacuation survival. Civil aviation authorities world-wide are trying to identify threats and measure performance for fire prevention. The results of research are standardized and given as general directions of test methods. This paper has prepared to study and present the means of compliance to the fire prevention requirements and applicable test methods.

고체에어로졸 소화장치의 B, C급 소공간 화재 소화성능 연구 (Fire Extinguishing Performance of Condensed Aerosol Extinguisher on the B,C Class Fire in a Small Cabinet)

  • 박용환;김범규;이성미
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2009년도 춘계학술논문발표회 논문집
    • /
    • pp.139-146
    • /
    • 2009
  • 현재 배전반, 소규모 유류저장고 등은 법적 의무 대상 공간이 아니어서 화재시 초기소화 실패로 인해 큰 재산상의 피해를 겪고 있으며, 이러한 소공간 화재에 대응할 수 있는 적합한 소화장치의 제도적 뒷받침이 시급한 실정이다. 현재 소공간용 소화장치에 대한 KFI 인정기준은 제정되어 있는 상태지만 다양한 새로운 기술에 부합하지 못하고 있어 소공간 소화장치에 대한 세분화된 법적기준 마련이 필요한 실정이다. 이에 본 연구에서는 국내외적으로 큰 관심을 받고 있을 뿐만 아니라 현재 KFI 인정기준으로도 제정되어 있는 고체에어로졸 소화장치가 B,C급 배전반, 분전반 등의 소공간 화재에 미칠 수 있는 소화성능을 실험적으로 분석하고 고체에어로졸 소화장치의 소공간화재 적합성 여부를 고찰해보고자 한다.

  • PDF

Application of reinforcement learning to fire suppression system of an autonomous ship in irregular waves

  • Lee, Eun-Joo;Ruy, Won-Sun;Seo, Jeonghwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.910-917
    • /
    • 2020
  • In fire suppression, continuous delivery of water or foam to the fire source is essential. The present study concerns fire suppression in a ship under sea condition, by introducing reinforcement learning technique to aiming of fire extinguishing nozzle, which works in a ship compartment with six degrees of freedom movement by irregular waves. The physical modeling of the water jet and compartment motion was provided using Unity 3D engine. In the reinforcement learning, the change of the nozzle angle during the scenario was set as the action, while the reward is proportional to the ratio of the water particle delivered to the fire source area. The optimal control of nozzle aiming for continuous delivery of water jet could be derived. Various algorithms of reinforcement learning were tested to select the optimal one, the proximal policy optimization.

최초의 평가시험 방법을 고려한 수격흡수기의 장치에 관한 연구 (A Study on the Water Hammer Arrester Considering the Way of First Assessment Test)

  • 염문천;한용택
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.53-59
    • /
    • 2015
  • 배관시스템의 불안정한 유동에 의해 생성되는 수격현상은 관내 압력의 과도한 변화, 진동 및 소음을 일으킬 수 있다. 이러한 수격현상은 관로, 펌프 및 밸브등의 시설물에 기계적인 사고를 유발시키는 원인이 되기도 한다. 한편, 국내에서는 수격현상으로 인한 피해를 최소화하기 위하여 수격흡수기를 제조 및 사용하여 왔으며, 그동안 별도의 기준이 없어 저가 위주로 생산 및 설치되어 왔다. 따라서, 본 연구에서는 수격흡수기 성능에 대한 최소 가이드라인을 제시하기 위하여, 하나의 배관으로 검증 가능한 시험방법, 수계소화설비에서 수격발생을 가정한 시험방법, 개방충격압과 차단충격압으로 구분한 흡수시험 방법, 배관을 분기한 시험시설 구성 방법 등의 다양한 방법들을 통하여 수격흡수기의 성능을 기준화 할 수 있는 방법등에 대하여 고안하였다. 그리고, 최종적으로는 U자형 배관과 시험용 추를 이용한 간단한 기계적 방식으로 수격흡수기의 수격압 흡수성능을 검증할 수 있는 실험 장치를 최초로 고안하여, 소방용 수격흡수기의 인정기준이 제정되었다.

위험물 탱크로리 화재진압 방안 (Dangerous tanker fire fighting measures)

  • 이정일
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2012년 추계학술대회
    • /
    • pp.215-223
    • /
    • 2012
  • Or maybe moving dangerous goods tanks of motorists excluded from the scope of the supervision of the fire department and fire prevention education as a blind spot on the part of a large party evidence of markers of contamination loading of dangerous goods according to the type of education that can be handled only by preparing the institutional arrangements accident is blocking the moving path of Dangerous Goods moving tanks and loading dangerous goods on fire budget move the path that corresponds to the report received by securing the extinguishing agent is required to neutralize the ash and fire suppression and repression through skills training from large disasters in advance blocking devices should prepare that will.

  • PDF

2유체 미세 물분무 소화노즐의 분무유동 특성 (Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression)

  • 김봉환;최효성;김동건
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

변전소 주변압기실 미분무수 소화시스템 성능평가를 위한 화재시나리오 (A Fire Scenario for Application of Water Mist System to an Indoor Power Transformer Room)

  • 최병일;한용식;김명배
    • 한국화재소방학회논문지
    • /
    • 제19권3호
    • /
    • pp.52-57
    • /
    • 2005
  • 미분무수 소화시스템의 소화구조는 분무되는 물의 조건뿐만 아니라 방호대상 공간의 상태에도 의존하기 때문에 일반적인 설계기준을 마련 할 수 없는 실정이다. 따라서 보편적인 성능평가 방법도 있을 수 없기 때문에 방호 대상물과 공간이 결정되면 그에 적절한 성능평가 기준이 마련되어야 한다. 본 연구에서는 변전소 주변압기실에 미분무수 소화시스템을 적용하기 위하여 성능평가 기준을 제안하고자 한다. 이를 위하여 유사 화재사례 조사, 사고 분석, 유사 성능평가기준 분석 등을 수행하였다.

화재대응능력 향상을 위한 화재모의훈련의 개선방안에 관한 연구 : 업무시설의 화재모의훈련 중심으로 (A study on the improvement plan of fire simulation training for the improvement of fire response ability : Focusing on the fire simulation training of business facility)

  • 김봉준;류구환
    • 디지털융복합연구
    • /
    • 제18권9호
    • /
    • pp.191-198
    • /
    • 2020
  • 본 연구에서는 화재대응능력 향상을 위한 화재모의훈련의 개선방안을 제안하기 위해 3개의 업무시설물을 대상으로 화재모의훈련을 실시하고 훈련 교보재의 활용 여부와 대응단계별 대응시간의 훈련평가 반영 여부에 따라 변화하는 훈련 참여자들의 대응자세 및 대응능력을 관찰 및 분석하였다. 분석결과 대다수의 훈련 참가자들은 훈련 교보재 활용과 대응단계별 대응시간이 훈련평가에 반영될 때 훈련 참여도, 대응자세 및 대응능력이 향상되는 것으로 분석되었다. 화재모의훈련을 실시할 경우 훈련 참여자들의 화재대응능력(화재통보 및 화재신고, 초기소화, 대피) 향상과 유지를 위해 화재발생 상황을 유사하게 구현할 수 있는 훈련 교보재를 다수 활용하고 각 대응단계별 목표시간을 설정한 후 이를 기반으로 정량적인 훈련평가를 하여야만 화재대응능력 향상과 향후 화재모의훈련의 개선 및 피드백에 유용한 지표로 활용될 수 있다는 결과를 도출하였다.

건축용 압출법 단열판(XPS)의 자기소화성에 대한 실험적 연구 및 제도적 관리에 관한 제언 (Experimental Study on the Self-extinguishing Performance of Extruded Polystyrene Insulation for Buildings and Suggestions on Institutional Management)

  • 강정기;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.141-149
    • /
    • 2020
  • 한국산업표준(KS)은 발포 플라스틱 제품에 대하여 소형화염에 의한 수평 연소성의 측정 방법 및 시험절차를 규정(KS M ISO 9772:2018)하고 측정 결과에 대한 압출법 단열판(이하 XPS)의 자기소화성과 관련한 성능 및 기준을 KS 규격(KS M 3808:2020)에서 규정하고 있다. KS 규격에 적합함을 인증 받은 제품은 연소성(이하 '자기소화성')을 가지고 있어야 함에도 공사현장에서 용접불티 등에 의해 착화 및 확산되어 대량의 인명과 재산 피해가 발생하고 있는 실정이다. 본 연구에서는 KS 인증을 받고 시중에 판매 중인 5개사의 XPS 단열재를 구입하여 공사현장에서 발생되는 용접불티에 의한 착화 및 확산 여부를 실험하였다. 실험결과, 5개사의 제품 중 3개사는 성능의 차이는 있으나 자기소화성이 있는 것으로 확인되었으나, 2개사는 쉽게 착화 및 확산되어 자기소화성이 있다고 보기 어려웠다. 동종의 제품에 대하여 KS 규정에 따른 실험결과, 용접불티에 의해 착화되었던 제품 2종을 포함한 총 3종의 제품이 KS M 3808에서 규정한 자기소화성이 없는 것으로 확인되었다.