• Title/Summary/Keyword: Fire Damper

Search Result 74, Processing Time 0.022 seconds

사격충격력 저감을 위한 연식주퇴계의 제어 (Control of a Soft Recoil System for Recoil Force Reduction)

  • 신철봉;배재성;황재혁;강국정;안상태;한태호
    • 한국소음진동공학회논문집
    • /
    • 제18권7호
    • /
    • pp.764-774
    • /
    • 2008
  • A fire-out-of-battery(FOOB) mechanism, which is a new recoil technology, can reduce dramatically the level of a recoil force compared to the conventional recoil system. The FOOB mechanism pre-accelerates the recoil parts in direction opposite of conventional recoil before ignition. This momentum of the recoil parts due to pre-acceleration can reduce the firing impulse. In this paper, the dynamics of the recoil system with this FOOB mechanism is formulated and simulated numerically. The results of the simulation show that the FOOB system can reduce the recoil force and stroke compared to the conventional system under normal condition. When the fault modes happen, the FOOB system may not perform well and may be damaged seriously due to excessive recoil force and stroke. Hence, the control of the fault modes is necessary to achieve the normal operation of the FOOB system. The results that an additional MR damper enables the FOOB system to perform well under all firing condition.

제연구역의 주요 매개 변수 및 누설 면적 변화를 고려한 차압 형성 관계 분석 (An Analysis on the Major Parameter and the Relations of Pressure Difference Effect of Leakage Area in the Smoke-Control Zone)

  • 유우준;고권현;사공성호;남준석;유홍선
    • 한국화재소방학회논문지
    • /
    • 제27권1호
    • /
    • pp.20-25
    • /
    • 2013
  • 본 연구에서 부속실 단독 가압 구조인 급기가압 제연설비의 성능 확보에 영향을 주는 주요 매개 변수를 분석하고 공급유량과 누설면적 변화에 따라서 풍도와 부속실 차압 형성 관계를 실험적으로 분석하였다. 이를 위해서 3층 규모의 총 10개의 구획공간으로 구성된 모형 구조물과 방화문의 개폐력 측정장치를 제작하였으며, 각 구획공간과 외기의 차압, 방연풍속을 측정하기 위한 제어 계측 장비를 구성하였다. 그 결과 댐퍼의 차압조절 범위가 45 Pa~55 Pa인 경우 공급유량과 부속실 차압 크기에 따라서 45 Pa 이하인 저압 영역, 45 Pa~55 Pa 구간인 차압조절 영역 그리고 55 Pa 이상인 과압 영역을 구분하였으며, 저압 영역에서는 부속실, 차압조절 영역에서는 부속실과 댐퍼 그리고 과압 영역 에서는 댐퍼의 누설면적이 차압 형성에 중요한 관계를 갖고 있는 것을 확인하였다.

특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구 (Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System)

  • 이수경;홍대화
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.85-90
    • /
    • 2011
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템에서 화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 형성되는 방연풍속의 특성을 FDS를 이용하여 해석하였고, 해석 결과를 분산분석으로 기류의 특성에 따른 측정 방안을 분석하고자 한다. 부속실과 같은 구획공간의 설계 조건에서 급기댐퍼에서 토출되는 보충량은 심한 와류를 형성하고 형성된 와류의 범위 안에 출입문이 존재할 경우 비정상적인 기체의 유동이 출입문지점에 발생한다는 것을 선행연구를 통하여 확인할 수 있었다. 국가화재안전기준 NFSC 501A에서 방연풍속을 측정할 때에는 출입문의 개방에 따른 개구부를 대칭적으로 균등 분할하는 10 이상의 지점에서 측정하는 풍속의 평균치로 할 것으로 정하고 있으나 이러한 조건에서는 출입구 상부 지점에 기류의 유입 현상을 파악하기 어렵고 풍속의 편차가 심하기 때문에 측정점을 공기조화설비의 시험조정 평가 기술기준에서 제시하는 64점 이상으로 세분화하여 측정하여야 할 것이다.

특별피난계단 부속실 제연설비의 방연풍속 기류특성에 관한 실험적 연구 (Experimental Study on Features of Air Egress Velocity in Vestibule Pressurization System)

  • 류성호;이수경;홍대화;윤명오;최금란;박재현
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.79-86
    • /
    • 2010
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템의 방연 풍속 기류 가화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 거실 방향으로 정상적으로 형성되지 않고 부속실 내부로 역류되는 현상을 개선하기위해 실 모형실험을 통해 출입구 상부로 역류하지 않는 조건을 개발하였다. 부속실 바닥 면적이 $2m^2$$4m^2$인 두개의 실물 모형을 제작하여 실험을 실시한 결과, 방연풍속의 기류 특성은 바닥 면적이 $2m^2$인 경우 심하게 출입문 상부로 기류가 역류되었다. 다만, 급기댐퍼의 설치위치가 출입문 맞은편의 경우 날개각도가 45도 상향인 경우는 출입문 상부로는 역 기류 현상은 없었지만 하부로는 일부 역류 되었다. 부속실 면적이 $4m^2$ 인 경우는 출입문에서 거실방향으로 정상적인 기류 분포를 보였다. 부속실 바닥 면적이 작게 설계될 경우에는 성능위주 설계가 될 수 있도록 하여야 한다.

통합 제연시스템의 컨트롤러 개발에 관한 연구 (A Study on the Controller of Integration Smoke Control System)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제20권1호
    • /
    • pp.77-82
    • /
    • 2006
  • 본 연구에서는 온도가 보상된 압력을 제연구역의 기준압력으로 설정하기 위한 공학적인 메커니즘과 보상방법을 정립하였고, 통합 제연시스템의 컨트롤러의 개발을 위한 프로세스, 알고리즘 확립과 엔지니어링 데이터의 구축으로 신뢰성이 확보된 통합 제연시스템의 컨트롤러를 개발하였다. 컨트롤러를 개발함으로서 비제연구역의 압력측정을 위해서 별도로 설치되는 압력측정관을 생략할 수 있어 제작단가와 설치비용 및 작업공수를 줄일 수 있고, 층별 제연구역의 차압측정을 위한 비제연구역의 압력측정포트를 시스템에 일체화함으로서 차압의 정밀도를 향상시킬 수 있다. 기존의 개별제어 방식에서 통합 제연시스템의 컨트롤러로부터 중앙집중식 통합관리를 함으로서 보다 정확하고 신뢰성 있는 차압을 얻을 수 있으며, 제연시스템에 유연성을 부과시킬 수 있을 것으로 본다. 또한 통합 제연시스템의 기틀을 마련하고 제연의 유연성을 주며 방재성능을 향상시킬 것으로 본다.

동흡진기를 이용한 포신의 진동감쇠에 대한 연구 (A Study on the Vibration Damping of a Barrel Using Vibration Absorber)

  • 곽동기;배재성;황재혁;김헌수
    • 한국소음진동공학회논문집
    • /
    • 제21권5호
    • /
    • pp.408-415
    • /
    • 2011
  • Advanced tanks in the future combat system are expected to have the trends of large caliber, high explosive shell and light weight for destructive power and improvement in mobility. Their guns are required to have longer barrels to meet increased muzzle exit velocities. However, as the length of the barrel is extended, the vibrations induced by the breech forces in fire and the terrain lead to increased muzzle pointing errors. Therefore, the fire-induced and terrain-induced vibrations must be attenuated. A method to reduce these vibrations without the significant increase of the gun mass is to use the forward thermal shroud as part of a tuned mass damper. In this study, the dynamically-tuned-shroud using this shroud and leaf springs is introduced and its effectiveness on the vibration attenuations of the barrel are verified. The parametric studies on the stiffness of these leaf springs are performed and the analytical results are verified using the experimental model of the dynamically-tuned-shroud.

굴뚝효과와 외부출입문 개방을 고려한 부속실 제연 (Vestibule Smoke Control Considering the Stack Effect and the Opening of the Outside Door)

  • 김용광;손주달;김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.15-24
    • /
    • 2024
  • The purpose of this study is to improve the stack effect of the staircase and the failure to take into account the opening of the outside door of the staircase, which are the disadvantages of the existing smoke control only vestibule. As a result of the study, the new vestibule and the staircase simultaneous smoke control are equipped with an exhaust flap damper with an effective opening area of about 0.25 m2 in the upper part of the staircase, and a ventilator-type air supply fan of about 5 m3/s in the lower part, and take measures to prevent overpressure in the staircase. If you use the new simultaneous smoke control method of the vestibule and staircase, you can achieve the following effects. First, it is possible to open the external entrance door. Second, it can reduce the stack effect. Third, the staircase door closes automatically without fail. And a new method of preventing overpressure was proposed for the vestibule.

제연 TAB를 통한 철도 지하환승통로의 거실제연설비 성능평가 (A Performance Evaluation of Zone Smoke Control Systems for Railway Underground Transit Passage by Smoke Control TAB)

  • 설석균;김준환;박민석;오승민;안용철;최준호
    • 한국화재소방학회논문지
    • /
    • 제31권1호
    • /
    • pp.1-9
    • /
    • 2017
  • 본 연구에서는 거실제연설비가 설치된 철도 지하환승통로에 현장성능평가시험인 제연 TAB(Test, Adjusting, Balancing)를 실시하여, 제연설비 성능 확보에 미치는 영향을 분석하고 개선방안을 도출하였다. 제연 TAB는 지하환승통로의 제연설비 설계자료 분석, 제연덕트 누기테스트, 제연송풍기와 덕트의 풍량 및 풍속 측정, Smoke test로 나누어 진행되었다. 제연덕트 누기시험을 통해 누기율을 측정하여 덕트의 기밀성을 확인하였고, 흡입측 덕트 정압손실로 인한 제연풍량 부족의 문제점을 개선하여 송풍기의 성능을 확보하였다. 또한, Smoke test을 통해 예상제연구역별 제연댐퍼 동작 시 자연풍, 열차풍 영향으로 인한 문제점을 분석하고 개선하여 예상 제연구역 내 제연이 원활하게 이루어짐을 확인하였다.

외팔보 구조물의 진동감쇠를 위한 동흡진기의 실험적 연구 (An Experimental study on the Vibration absorber for vibration attenuation of cantilever beam structure)

  • 곽동기;배재성;황재혁;김헌수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.627-632
    • /
    • 2011
  • This study was carried out vibration attenuation of vibration absorber attached to the cantilever beam structure. Modern tank guns are stabilized to allow fire on the move while traversing uneven terrain. However, as the length of the barrel is extended, to meet required muzzle exit velocities, the terrain induced vibrations lead to increased muzzle pointing errors. Thus, reducing these vibrations should lead to increased accuracy. The vibration absorber includes a compliant energy storage device, such as a spring, and a mass secured to the energy storage device. In this study, it accomplished a research in about gun barrel vibration attenuation using tuned mass damper. The barrel was hung from a bungee cord for free - free condition. It accomplished a vibration experiment for verified attenuation efficiency.

  • PDF

부속실제연설비 급기댐퍼의 설치위치 적정성 연구 (A Study on the Adequacy of the Installation Location of the Air Supply Damper of the Attached Actual Smoke Facility)

  • 양성훈
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2022년 정기학술대회 논문집
    • /
    • pp.193-194
    • /
    • 2022
  • 본 연구에서는 특별피난계단의 전실에 설치되는 부속실제연설비가 화재 시 발생한 연기가 부속실 내로 역류하지 않는 급기댐퍼의 적정한 설치위치를 알아보고자 하였으며, 이를 확인하기 위하여 FDS(Fire Dynamics Simulator)을 사용 하였다. 시뮬레이션 Case 총 15가지로 구분하고, 방연풍속은 총 64개의 지점에서 측정하는 시뮬레이션을 수행하였다. 시뮬레이션 결과 출입문 상부 및 하부에서 역 기류가 발행하는 Case가 있었으며, 대부분 출입문 하부에서의 연기 유입이 예상되는 경우가 많았다. 방연풍속은 측정 포인트 64점에서 관련기준에 단 한 곳도 미달하지 않고 만족하는 경우는 총 단 4가지 Case로서 매우 제한적인 것을 알 수 있었다. 그만큼 급기댐퍼의 위치 및 급기방향에 따라 부속실 제연설비의 성능이 다양하게 나타날 수 있다는 것이다. 본 연구를 바탕으로 앞으로 실물실험을 통하여 구체적인 자료가 입증되길 바라고, 더불어 부속실 제연설비의 성능을 개선하는 데 있어 도움이 되었으면 한다.

  • PDF