• Title/Summary/Keyword: Fine Tube

Search Result 117, Processing Time 0.028 seconds

Fine Structural Study on the Capture Threads-producing Organs in Nephila clavata L. Koch (Araneae: Araneidae) II. Flagelliform Glands (무당거미(Nephila clavata L. Koch))

  • 문명진;김우갑
    • The Korean Journal of Zoology
    • /
    • v.33 no.3
    • /
    • pp.354-364
    • /
    • 1990
  • The ultrastructure and silk formational process of the flagelliform glands, one of the capture thread producing organs in the orb web spider (Nephila clavata L. Koch), have been studied with electron microscope. A pair of flagelliform glands consist of three distinct regions: excretory duct, storage sac and convoluted tail. This gland is connected to the large spinning tube (spigot) of the posterior spinnerets with two pairs of aggregate glands, and showed a characteristic spigot structure called "triad". The excretory duct consists of three long segments surrounded by the same sheath of connective tissue. The distal duct near the spinning tube bears the electron lucent subcuticles which have the functions of water removal and orientation of the silk fiber, whereas the proximal duct near the sac contains the cuticule precursor transported through the intercellular space. Cytoplasms of the sac and tail regions have well developed rough endoplasmic reticulum and contain the round secretory granules commonly, but the electron densities and internal textures of the granules do not coincided. Adjacent epithelial cells are connected with the specialized septate junctions, and secretory granules accumulated at the apical pole are released to the lumen by the apocrine secretion.secretion.

  • PDF

A study on Phantom image of Mammography in some area (일부지역 유방촬영술의 팬톰영상에 관한 연구)

  • Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.301-306
    • /
    • 2005
  • Purpose : The goal of this study was to survey the quality control of mammographic phantom images in some area. Methods : Between May and June, 2005, I have got a total of 47 mammographic phantom images collected from 49 hospitals and were analized about phantom score of fibrous, speck, tumor with enlargement scope. By critic level of experimental mammographic phantom case images, classified through the pass case that fibrous score 4, speck score 3, tumor score 3 over. Result : It passed 33case (70.3%), failed 14 case (29.7%) about 47 case. Passing case images showed tube voltage $23{\sim}30\;kVp$, tube current $20{\sim}60\;mAs$, photographic density $0.48{\sim}1.77$ Conclusion : It passed case about 70.3% of mammographic phantom image in some area. Optimum range of tube voltage, tube current, photographic density have to use to get fine quality of mammographic images.

  • PDF

Verification of dilution ratio of the newly developed ejector-porous tube diluter for measurement of fine dust in coal-fired power plant stack (화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증)

  • Shin, Dongho;Kim, Young-Hoon;Hong, Keejung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Lee, Ga-Young;Chun, Sung-Nam;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.15 no.3
    • /
    • pp.105-113
    • /
    • 2019
  • The exhaust emissions from coal-fired power plants have received much attention because coal-fired power plants are the one of the largest sources of particulate matter (PM) emissions in South Korea. To measure the PM10 and PM2.5, we developed the novel diluter which is comprised of ejector and porous tube in series. The dilution ratio must be defined to calculate particle concentrations of the sampled air as well as to probe match for the isokinetic sampling. For this reason, we verified the dilution ratio of the developed diluter by the flow rate, numerical solution, gas concentration and particle concentration. The ejector-supplied flow rates were 10-50 L/min and the porous tube-supplied flow rates were 30, 50 L/min in this study. All methods above showed similar dilution ratios to each other within 10 % error rate. The dilution ratio was confirmed by comparing mass concentrations before and after the dilution process.

Installation Technology and Behavior of Silty Clay Filled Geotextile Tube (실트질 점토 채움 시 지오텍스타일 튜브의 거동 및 시공 방법에 관한 연구)

  • Shin, Eun-Chul;Oh, Young-In
    • Journal of the Korean Geosynthetics Society
    • /
    • v.1 no.1
    • /
    • pp.13-21
    • /
    • 2002
  • Geotextile tubes hydraulically or mechanically filled with dredged materials have been applied in hydraulic and coastal engineering in recent years(detached breakwater, groins and jetty). The geotextile tubes are made of sewn geosynthetics sheets. If the sandy soil is use to fill material, these inlets should be spaced closely to assure uniform filling of the tubes because sandy soil and geosynthetic is very pervious. However, the clayey soil or contaminated slurry is used, the inlets can be located relatively long distance. The fine clayey particles tend to rapidly blind the fabric slowing down water escape through the geotextile. This paper presents a field test result of a geotextile tube in the land reclamation project for the Songdo New City construction site. The dredged silty clay was dredged by the dredging ship and hydraulically pumped into the geotextile tube. The height of geotextile tube was measured at every filling stage and also measured width and diameter of geotextile tube with the elapsed time. Based on the test results, if the clayey filling material is used, the pumping step must be divided 3~4 stages for drainage and sediment. After complete drainage, the height of the geotextile tube reduces by approximately 50%.

  • PDF

Development of End-milling Inspection System Using 450kVp Tube Voltage (450kVp Tube Voltage를 이용한 엔드밀링 검색 시스템 개발)

  • Yoon, Moon-Chul;Jung, Jin-Seok;Hwang, In-Ho;Yuk, Sun-Woo;Park, Su-Kang;Chin, Do-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.2
    • /
    • pp.10-17
    • /
    • 2009
  • Transillumination system used by radiation is widely applied to industrial imaging system. In this study, the linear detector array constructed with scintillator and pin diode, and a multi-channel data acquisition system was developed for precision inspection of end-milling. The detector module consists of $16-CdWO_4$crystal scintillator and photodiode array. The detector and data acquisition system was applied to precision inspection of end-mill and the images of the end-mill were successfully reconstructed. The total system can analyze the Detector Quantum Efficiency(DQE) of each system. The performance of developed photodiodes equipment was compared with each other for different crystal geometry and its characteristics. Finally fine details of the end-mill phantom were constructed for industrial application. The image acquired contains several objects on a real time data transfer and the linear X-ray scanning system can be applied to many fields of a industry.

  • PDF

A Control of Ice Packing Factor of Ice Slurry in a Pipe using IPF Controller (IPF 조절기를 이용한 배관내 아이스 슬러리의 빙충전율 제어)

  • Kwon, Jae-Sung;Lee, Yoon-Pyo;Yoon, Seok-Mann
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1105-1110
    • /
    • 2008
  • An experimental study was performed to control Ice Packing Factor (IPF) of ice slurry in a pipe in a real time. This paper presented the concept that IPF can be adjusted by the amount of the solution contained to ice slurry. Based on this concept, we designed IPF controller consisting of the outlet tube providing ice slurry and the upper tube discharging only a solution through holes, and investigated the technical validity and efficiency of the controller experimentally. As a result, the original proposed IPF controller could not control IPF of ice slurry in a pipe. This is because an ice of ice slurry was drained out into not only the outlet but also the upper of the controller due to the size of the holes relatively large compared to the ice particle. Therefore, we changed the hole size of IPF controller surface using fine meshes and then, observed that IPF in a pipe was increased by $4{\sim}7$ percent when the hole size was $80{\mu}m$ and less.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFICIENCY OF A LOCAL VENTILATION SYSTEM AND THE PROTECTING FACE MASKS IN DENTAL LABORATORIES

  • Kim, Uoong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.95-102
    • /
    • 1989
  • This study was performed to study the efficiency of a local ventilation system, installed in dental laboratories, and of two types of protecting face masks. The dust originating from the workpiece as well as from the wheels and stones was collected on air filters in the cutting cycle during coarse and fine grinding, and in the subsequent polishing procedures of each specific dental material. The efficiency of the ventilation system was measured on the basis of weight reduction of dust in the breathing air at a distance about 20-40 cm from workpiece. The results were as follows: 1. Use of the local ventilation system reduced the amounts of respirable dust to an average level of 21.4%, although the efficiency of the local ventilation system varied depending upon materials used. 2. Mounting a nozzle on the tube improved the efficiency of the ventilation system considerably. The efficiency of the local ventilation system also increased as the workpiece was closing to the tube inlet. 3. With or without the local ventilation system, the distance between the position of the workpiece and sampler greatly affected the dust level. 4. The face masks covering the sampler improved the efficiency of the ventilation system considerably.

  • PDF

Airborne Fine Particle Measurement Data Analysis and Statistical Significance Analysis (공기중 미세입자 측정 데이터 분석 및 통계 유의차 분석)

  • Sung Jun An;Moon Suk Hwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.1-5
    • /
    • 2023
  • Most of the production process is performed in a cleanroom in the case of facilities that produce semiconductor chips or display panels. Therefore, environmental management of cleanrooms is very important for product yield and quality control. Among them, airborne particles are a representative management item enough to be the standard for the actual cleanroom rating, and it is a part of the Fab or Facility monitoring system, and the sequential particle monitoring system is mainly used. However, this method has a problem in that measurement efficiency decreases as the length of the sampling tube increases. In addition, a statistically significant test of deterioration in efficiency has rarely been performed. Therefore, in this study, the statistically significant test between the number of particles measured by InSitu and the number of particles measured for each sampling tube ends(Remote). Through this, the efficiency degradation problem of the sequential particle monitoring system was confirmed by a statistical method.

  • PDF

A Study on the Optimal Design of Soft X-ray Ionizer using the Monte Carlo N-Particle Extended Code (Monte Carlo N-Particle Extended 코드를 이용한 연X선 정전기제거장치의 최적설계에 관한 연구)

  • Jeong, Phil hoon;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.34-37
    • /
    • 2017
  • In recent emerging industry, Display field becomes bigger and bigger, and also semiconductor technology becomes high density integration. In Flat Panel Display, there is an issue that electrostatic phenomenon results in fine dust adsorption as electrostatic capacity increases due to bigger size. Destruction of high integrated circuit and pattern deterioration occur in semiconductor and this causes the problem of weakening of thermal resistance. In order to solve this sort of electrostatic failure in this process, Soft X-ray ionizer is mainly used. Soft X-ray Ionizer does not only generate electrical noise and minute particle but also is efficient to remove electrostatic as it has a wide range of ionization. X-ray Generating efficiency has an effect on soft X-ray Ionizer affects neutralizing performance. There exist variable factors such as type of anode, thickness, tube voltage etc., and it takes a lot of time and financial resource to find optimal performance by manufacturing with actual X-ray tube source. MCNPX (Monte Carlo N-Particle Extended) is used for simulation to solve this kind of problem, and optimum efficiency of X-ray generation is anticipated. In this study, X-ray generation efficiency was measured according to target material thickness using MCNPX under the conditions that tube voltage is 5 keV, 10 keV, 15 keV and the target Material is Tungsten(W), Gold(Au), Silver(Ag). At the result, Gold(Au) shows optimum efficiency. In Tube voltage 5 keV, optimal target thickness is $0.05{\mu}m$ and Largest energy of Light flux appears $2.22{\times}10^8$ x-ray flux. In Tube voltage 10 keV, optimal target Thickness is $0.18{\mu}m$ and Largest energy of Light flux appears $1.97{\times}10^9$ x-ray flux. In Tube voltage 15 keV, optimal target Thickness is $0.29{\mu}m$ and Largest energy of Light flux appears $4.59{\times}10^9$ x-ray flux.

Studies on the Testis of the Fall-web worms, Hyphantria cunea Drury I. Fine Structure of the Testis (미국흰불나방(Hyphantria cunea Drury) 정소(精巢)에 관한 연구 I. 정소(精巢)의 미세구조(微細構造))

  • Moon, Myung-Jin;Lee, Keun-Ok;Kim, Chang-Whan;Kim, Woo-Kap
    • Applied Microscopy
    • /
    • v.18 no.1
    • /
    • pp.49-59
    • /
    • 1988
  • Fine structures of the testis and vas deferens in the fall-web worm, Hyphantria cunea Drury, are studied with electron microscope. Adult worms have single testis close to the midlines of the abdomen. Testis is composed of 4 follicles which are incompletly separated from each other and bounded together by a peritoneal sheath. The peritoneal sheath consisted of outer cuticular layer and two kinds of inner layers, in which glycogen particles are dispersed commonly. These two layers are divided by the morphology of cytoplasmic granules. Follicular epithelium forming the wall of the follicles have melanin pigment granules, and trachea or tracheoles are extended through this epithelium. In the cysts of adult testis, matured spermatozoa are grouped together in bundles and after releasing the sperm bundles to the vas deferens, lamellar shaped lysosomes appeared in the cytoplasms of the cyst cells. The number of spermatozoa per cyst is exactly 256 ($2^8$), this number is characteristics of the Lepidoperan species. Vas deferens is a tube with a fairly thick bounding epithelium, a basement membrane and a layer of circular muscle outside it. At the apical portion of the epithelial cells, microvilli are well developed. And in the cytoplasms of these cells, numerous excretory granules are observed.

  • PDF