• 제목/요약/키워드: Fine Particulate Matter

검색결과 285건 처리시간 0.025초

PM10/2.5/1/0 Trichotomous 도입부 설계 밀 성능평가 (Design and performance of Low-Volume PM10/2.5/1.0 Trichotomous Sampler Inlet)

  • Song Chang-Byeong;Kim Hyeon-Tae;Lee Gyu-Won
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 추계학술대회 논문집
    • /
    • pp.358-359
    • /
    • 2002
  • Particulate matter smaller than $10{\mu}textrm{m}$ in aerodynamic diameter (PM10) is known as thoracic particles that are capable of reaching the thoracic region of humans. PM10 is further divided into two size ranges, which are fine particles (nuclei mode plus accumulation mode) and coarse particles, based on different sources and chemical composition. Fine particles can penetrate deep into the alveolar region of the human lungs, while coarse particles be deposited in the upper respiratory system. (omitted)

  • PDF

Development of a High-Volume Simultaneous Sampler for Fine and Coarse Particles using Virtual Impactor and Cyclone Techniques

  • Okuda, Tomoaki;Shishido, Daiki;Terui, Yoshihiro;Fujioka, Kentaro;Isobe, Ryoma;Iwaki, Yusuke;Funato, Koji;Inoue, Kozo
    • Asian Journal of Atmospheric Environment
    • /
    • 제12권1호
    • /
    • pp.78-86
    • /
    • 2018
  • Filter-based sampling techniques are the conventional way to collect particulate matter, but particles collected and entangled in the filter fibers are difficult to be removed and thus not suited for the following cell- and animal-based exposure experiments. Collecting aerosol particles in powder form using a cyclone instead of a filter would be a possible way to solve this problem. We developed a hybrid virtual-impactor/cyclone high-volume fine and coarse particle sampler and assessed its performance. The developed system achieved 50% collection efficiency with components having the following aerodynamic cut-off diameters: virtual impactor, $2.4{\mu}m$; fine-particle cyclone, $0.18-0.30{\mu}m$; and coarse-particle cyclone, $0.7{\mu}m$. The virtual impactor used in our set-up had good $PM_{2.5}$ separation performance, comparable to that reported for a conventional real impactor. The newly developed sampler can collect fine and coarse particles simultaneously, in combination with exposure testing with collected fine- and coarse-particulate matter samples, should help researchers to elucidate the mechanism by which airborne particles result in adverse health effect in detail.

부산지역 미세먼지 최근 경향 분석 - 수도권과 비교연구 (I) (Analysis of Recent Trends of Particulate Matter Observed in Busan - Comparative Study on Busan vs. Seoul Metropolitan Area (I))

  • 김종민;조유진;양금희;허국영;김철희
    • 한국환경과학회지
    • /
    • 제29권2호
    • /
    • pp.177-189
    • /
    • 2020
  • We analyzed the recent characteristics of Particulate Matter (PM) including PM10 (PM with diameter of less than 10 ㎛) and PM2.5 (PM with diameter of less than 2.5 ㎛) observed in Busan metropolitan area, and compared them with those measured in Seoul metropolitan area. This analysis includes the monthly, seasonal, and annual variations and differences, in emissions and chemical compositions observed in both Busan and Seoul areas. Synoptic meteorological conditions were investigated at the time when high PM concentrations occurred in each of the two areas. The results showed clearly decreasing trends of annual mean concentrations with strong seasonal variations: lower in summer and higher in winter in both areas. In comparison with Seoul, the seasonal variation in Busan demonstrated relatively lower, but showed greater summer fluctuations than in Seoul metropolitan area. This is implying the importance of secondary generation of PM in summer via active photochemical reaction in Busan area. In high concentration days, Busan's chemical composition of sulfate was higher than that of nitrate in summer, whereas nitrate was higher than sulfate in Seoul. The ratios of NO3- to SO42-(N/S ratio) showed lower in Busan approximately by a factor of 1/2(half of N/S ratio) in Busan compared with that in Seoul. Others such as synoptic characteristics and emission differences were also discussed in this study.

Satellite-based Assessment of Ecosystem Services Considering Social Demand for Reduction of Fine Particulate Matter in Seoul

  • Lim, Chul-Hee
    • 대한원격탐사학회지
    • /
    • 제38권4호
    • /
    • pp.421-434
    • /
    • 2022
  • Fine particulate matter (PM2.5) has been the biggest environmental problem in Korea since the 2010s. The present study considers the value of urban forests and green infrastructure as an ecosystem service (ES) concept for PM2.5 reduction based on satellite and spatial data, with a focus on Seoul, Korea A method for the spatial ES assessment that considers social demand variables such as population and land price is suggested. First, an ES assessment based on natural environment information confirms that, while the vitality of vegetation is relatively low, the ES is high in the city center and residential areas, where the concentration of PM2.5 is high. Then, the ES assessment considering social demand (i.e., the ESS) confirms the existence of higher PM2.5 values in residential areas with high population density, and in main downtown areas. This is because the ESS of urban green infrastructure is high in areas with high land prices, high population density, and above-average PM2.5 concentrations. Further, when a future green infrastructure improvement scenario that considers the urban forest management plan is applied, the area of very high ESS is increased by 74% when the vegetation greenness of the green infrastructure in the residential area is increased by only 20%. This result suggests that green infrastructure and urban forests in the residential area should be continuously expanded and managed in order to maximize the PM2.5 reduction ES.

사이클론 전처리부를 지닌 터널집진차량의 집진효율 최적화 (Dust collection optimization of tunnel cleaning vehicle with cyclone-based prefilter)

  • 정우태
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.679-686
    • /
    • 2018
  • 지하철 터널 내에 축적된 미세먼지와 초미세먼지를 제거하기 위해서는 새로운 형식의 분진흡입차량이 필요하다. 따라서 최근 개발된 분진흡입차는 초미세먼지 제거를 위한 흡입시스템과 사이클론형식의 전처리부 및 전기집진기를 장착하고 있다. 본 논문에서는 집진차량의 하부에 설치된 먼지 흡입시스템이 다양한 크기의 먼지입자를 효과적으로 흡입하고 처리하기 위해 사이클론형식의 전처리부가 포함된 집진시스템을 설계하고 집진효율을 ANSYS FLUENT의 전산유체해석을 통해 확인하였다. 흡입구와 사이클론형 프리필터가 연결된 격자모델을 기반으로 공기유동과 상차분모델(Discrete Phase Model)을 이용하여 다양한 입자의 크기와 종류 및 흡입팬의 용량에 따른 입자의 거동을 해석하였다. 다양한 입자의 크기와 종류, 흡입팬의 용량에 대해서 해석결과 집진차량의 운영속도 5km/h에서 미세먼지처리를 위해서는 흡입팬의 용량 $1500m^3/min$에서 흡입구가 궤도면으로부터 약 100mm이내일 때 $100{\mu}m$ 이하 크기의 먼지를 모두 처리할 수 있음을 확인하였다. 이러한 흡입구와 사이클론형식의 프리필터를 탑재한 터널집진차량은 후단에 설치된 전기집진기의 부하를 줄이고, 지하 터널내의 미세먼지와 초미세먼지의 제거에 효과적으로 활용될 수 있을 것으로 기대된다.

선박 디젤엔진 배출 미세먼지 저감을 위한 정전 여과 매연 집진기 개발에 관한 연구 (An Electrostatic Diesel Particulate Filtration System for Removal of Fine Particulate Matters from Marine Diesel Engines)

  • 김영훈;이건희;홍기정;김용진;김학준;박인용;한방우
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.101-110
    • /
    • 2023
  • In order to reduce particulate matters (PM) from marine diesel engines, we developed novel electrostatic diesel particulate matter filtration system. Electrostatic diesel particulate filtration (DPF) system consists of electrostatic charger and filtration part. The electrostatic charger and filtration part are composed of a metal discharge electrode and a metal fiber filter (porosity: 68.1-86.1%), respectively. In the electrostatic charger part, diesel soot particles are reduced by electrostatic force. The filtration part after electrostatic charger part reduces diesel soot particles through inertial and diffusion forces. The filtration efficiency of electrostatic DPF system was examined through the experiments using engine dynamometer system (300 kW) and ship (200 kW). The PM reduction efficiencies due to inertial and electrostatic forces showed about 70-75% and 80-90%, respectively, according to the RPM of the engine. The differential pressure of the electrostatic DPF system applied to the ship was about 1-9 mbar, which was less than the allowable differential pressure for ship engines in South Korea (100 mbar). The results show that the electrostatic DPF system is suitable for application to the PM reduction emitted from ships.

금속필터를 사용한 석탄가스화 분진 및 표준 분진의 집진 효율과 운전특성 (Dust Removal Efficiency and Operation Characteristics of Metal Filters for Coal Gasification Fines and Standard Dust Sample)

  • 윤용승;정석우;이승종
    • Korean Chemical Engineering Research
    • /
    • 제57권4호
    • /
    • pp.461-468
    • /
    • 2019
  • 석탄화력발전소에서 발생하는 분진 효율을 높이고 미세먼지와 극미세먼지까지 집진할 필요성이 높아지고 있다. 상압 영역에서 운전되는 플랜트 발생 분진 제거를 위해서는 백필터나 전기집진기를 사용하나, 고온고압에서 운전되는 석탄가스화와 같은 경우는 금속필터나 세라믹필터가 사용된다. 고온고압에서 분진 집진을 위해 2종의 5겹 압착/소결한 금속필터를 제작하였고 이를 사용했을 때 분진 포집효율과 $10{\mu}m$ 이하 입자에 대한 포집 성능을 파악하였다. 석탄가스화 분진에 대한 금속필터의 집진효율은 무게기준으로 99%대에 달하였다. 제작한 금속필터 2종의 미세먼지 입자 이하(< $2.5{\mu}m$) 크기까지 집진성능을 파악하고자 JIS 분진 표준시료를 대상으로 실험을 수행하였고, $1{\sim}2.5{\mu}m$ 입자크기 범위에 대해 97%와 70~82%의 집진 성능을 확인하였다. $1{\mu}m$ 이하 입자크기 영역에서는 입자크기가 작아짐에 따라 제작한 금속필터의 집진효율이 급격히 낮아짐을 볼 수 있었다. 이러한 $1{\mu}m$ 이하 입자들에 대한 집진 제한점을 극복하고자 금속필터 성능의 개선 방안을 제시하였다.

공동주택에서 미세먼지 저감을 위한 에어샤워 성능실험 (Experiment of Air-Shower to Reduce Particulate Matter in Apartment Housing)

  • 박진철;정홍구
    • 토지주택연구
    • /
    • 제12권2호
    • /
    • pp.91-97
    • /
    • 2021
  • 본 연구는 에어샤워 시스템의 가동에 따른 5종의 의류(Dress Suit, Hiking Clothes, Knit, Cotton T-Shirt, Coat)의 미세먼지의 제거성능을 파악하고자 한 것으로 그 연구결과를 요약하면 다음과 같다. 첫째, 에어샤워 시스템 가동 실험결과, 미세먼지 제거율은 1회 가동시에만 평균 59.4%가 제거 되고 있었다. 특히, 2회 및 3회 가동시에는 68.5%에서 최고 73.3% 까지 제거율을 나타내고 있었다. 둘째, 5종류의 의류종류별 제거율은 Dress Suit 74.0% > Hiking Clothes 70.6% > Knit 63.3% > Cotton T-Shirt 50.5% > Coat 38.8% 순으로 나타났다. 즉, 의류 종류에 따라 코트 등 털 소재의 의류는 정전기 등의 원인으로 미세먼지 제거율이 다른 소재에 비해 적게 나타났지만 보통 의류인 경우는 50% 이상의 제거율을 보이고 있었다.

공조풍량별 식생바이오필터의 입자상 오염물질 저감효과 연구 (A Study on Particulate Matter Reduction Effects of Vegetation Bio-Filters by Airflow Volume)

  • 최부헌;김태한
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.89-95
    • /
    • 2021
  • As the influence of fine dust on society spreads gradually, the public's interest in indoor air is increasingly rising. Air-purifying plants are drawing keen attention due to their natural purifying function enabled by plant physiology. However, as their fine dust reduction mechanism is limited to adsorption only, vegetation bio-filters that optimize purification effects through integration with air-conditioning systems is rising as an alternative. In accordance with the relevant standard test methods, this study looked into the fine dust reduction assessment method by air-conditioning airflow volume that can be used for the industrial spread of vegetation bio-filters. In the case of PM10 at 300 ㎍/m3, it was in the order of EG-B(3,500CMH, 29 min.) < EG-A (2,500CMH, 37 min.) < CG(0CMH, 64 min.) for reaching the maintenance level (100 ㎍/m3) of publicly used facilities. For reaching the WHO Guideline(50 ㎍/m3) requirement, it was in the order of EG-B (51 min.) < EG-A (160 min.) < CG (170 min.). In the case of PM2.5, it was in the order of EG-B (26 min.) < EG-A (33 min.) < CG (57 min.) for reaching the maintenance level (50 ㎍/m3) of publicly used facilities. It was in the order of EG-B (48 min) < EG-A (140 min) < CG (158 min) for reaching the WHO Guideline (25 ㎍/m3) requirement. The findings from the analysis showed that fine dust can be reduced most efficiently when the system is operated at 3,500CMH level. The limitation of this study is that due to the absence of a way of assessing the stress of plants in vegetation bio-filters, generating optimal air-conditioning air flow of the relevant system and economics analysis against the existing facility-type air purification system have been clarified, which should be explored further though follow-up studies.

황사기간도안 제주, 고산지역에서 호흡성 분진의 입자 분포 특성 (Characteristics According to the Size Distributions of Respirable Particulate During Yellow Sand Episode in Kosan, Jeju Island)

  • Kim, Jeong-Ho;Ahn, Jun-Young;Han, Jin-Seok;Lee, Jeong-Joo
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.91-96
    • /
    • 2003
  • This study was intended as an investigation of characteristics of background site atmospheric respirable particulate matters(RPM), and fine particles(<2.5 ${\mu}{\textrm}{m}$). The particle size distributions during the phenomenon of Yellow Sand(YS) occurs from April, 2001. Atmospheric aerosol particulate matter was directly collected on the Jeju island between 1 to 30, April, 2001 using an eight-stage cascade impacter(particle size range: 0.43-11 ${\mu}{\textrm}{m}$), and cyclone separator(cut size: 2.5, 10 ${\mu}{\textrm}{m}$). The episode of YS observed in background monitoring site, Kosan and appeared 2 times at sampling period. The mass concentrations of fine and coarse particles for YS episode were 34.2 and 59.6 $\mu\textrm{g}$/㎥, respectively, which were significantly increased amounts compared to 13.3 and 13.0 $\mu\textrm{g}$/㎥ for NonYS(NYS). Most size distributions had two peaks, one at 0.43∼.65 ${\mu}{\textrm}{m}$ and the other at 3.3${\mu}{\textrm}{m}$4.7 ${\mu}{\textrm}{m}$. The result of analysis of water-soluble ion component indicated that sulfate was mainly ion component, but nitrate and calcium ion was significantly increased at the YS episode.