• 제목/요약/키워드: Filtration pressure

검색결과 356건 처리시간 0.024초

조사후시험시설에서의 방사성 오염배기체의 포집장치 및 여과효율 (Filtration System and its Efficiency of Exhaust System at Post Irradiation Examination Facility)

  • 황용화;이형권;전용범;민덕기;엄성호;홍권표
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.96-100
    • /
    • 2003
  • 조사후시험시설에는 시설내의 부압기준을 다르게 설정하여 시설의 운전조건을 최적화로 유지하고 방사성물질을 처리하기 위한 오염배기를 포집하는 여과장치가 설치되어 있다. 필터 포집장치에 대해 관련된 효율시험과 검사를 주기적으로 수행하여 운전효율과 안전을 향상시키고 있다.

  • PDF

Membrane Concentrate Thickening by Hollow-fiber Microfilter in Drinkin Water Treatment Processes

  • Lee, Byung-Ho
    • Korean Membrane Journal
    • /
    • 제1권1호
    • /
    • pp.100-105
    • /
    • 1999
  • A novel system to thicken the concentrated colloidal solution from membrane water treat-ment processes was developed. A hollow-fiber microfilter(hydrophilic polyethylene nominal pore size 0.1 ${\mu}$m total surface area 0.42 m2) was installed in an acrylic housing that has an aeration port 5 cm below the membrane and a clarifier in the bottom. The concentrate was uniformly supplied from the top of the housing. Bacuum filtration caused downward flow of concentrate and as a result thickening interface. The addition of poly-aluminum chloride (PAC) resulted in rapid increase of trans-membrane pressure (TMP) and in no improvement of the filtered water turbidity and thickening process. Two types of con-centrate and concentrate turbidity had little effect on the increase of TMP and concentrate thickening. It was observed that for the same height of membrane housing membrane surface area to housing volume (A/V) ratio had significant effect on the increase of TMP. When the housing volume was increased ten times the increasing rate of TMP was three times faster as compared to the original housing. A hydraulic model successfully simulated the formation and sedimentation of thickening interface.

  • PDF

Purification and Characterization of an Angiotensin Converting Enzyme Inhibitor from Squid Ink

  • Kim, So-youn;Kim, Sun-hye;Song, Kyung-Bin
    • 한국식품저장유통학회:학술대회논문집
    • /
    • 한국식품저장유통학회 2003년도 제23차 추계총회 및 국제학술심포지움
    • /
    • pp.135.2-135
    • /
    • 2003
  • Angiotensin converting enzyme (ACE) converts angiotensin I into angiotensin II by cleaving C-terminal dipeptide of angiotensin I and inactivates bradykinin. ACE inhibitors have been screened from various food sources since the inhibitors decrease blood pressure. Therefore, in this study, an ACE inhibitor was isolated and purified from squid ink using membrane filtration, gel permeation chromatography, normal phase HPLC, and fast protein liquid chromatography. The purified inhibitor was identified to be a molecular mass of 294 by mass spectrometry, and to have IC$\sub$50/ value of 4.9 $\mu\textrm{g}$/mL.

  • PDF

CFD를 활용한 DOC-DPF 조합의 유동 균질도 분석 (Flow Uniformity Analysis of DOC-DPF System using CFD)

  • 김태훈;박성욱
    • 한국분무공학회지
    • /
    • 제24권3호
    • /
    • pp.122-129
    • /
    • 2019
  • Flow uniformity in aftertreatment system is an important factor in determining uniform catalytic reaction and filtration. In this study, variety types of DOC-DPF system design were analyzed to increase flow uniformity. For this analysis, ANSYS Fluent was used with porous media setup for DOC and DPF. Turbulent flow was modeled by standard $k-{\varepsilon}$ model excepting porous media. Uniformity index was utilized to evaluate the flow uniformity quantitatively. Reference design showed low velocity region because two large vortex were generated before baffle. When radius of DOC-DPF system was increased, exhaust pressure acting on the inlet decreases and velocity distribution was shifted to one side. When inlet pipe was set to axial center of DOC-DPF system velocity distribution was symmetric. However, flow was not dissipated until the front end of DOC and showed higher uniformity index. When the volume of DOC was reduced while fixed volume of entire DOC-DPF system and baffle plate is located downstream of the DOC-DPF system, there was improvement in uniformity index.

양전하가 부가된 수처리 필터의 입자제거특성에 관한 연구 (A Study on the Positively Charged Filter for Removing Fine Particles in Water)

  • 정성학;김종원;김상희;전병헌;이승갑;이재근;안영철
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.454-460
    • /
    • 2012
  • The purpose of the present work is to investigate the removal characteristics of positively charged filters for capturing negatively charged particles such as bacteria and virus in water. In order to reduce the pressure drop and increase the filtration efficiency, the filter media, modified by charge modifier having positive functional groups, is developed and evaluated. Improved liquid filters have been developed with the modified surface charge to capture and adsorb particles by electrokinetic interaction between the filter surface and particles contained in an aqueous liquid. The positively charged filter media is composed of glass fiber, cellulose and poly-ethylenimine resin for positively charging with the variation of volume ratio. The zeta potential value of the positively charged filter is +37.92 mV at the glass fiber and cellulose content ratio of 50 : 50 with resin content of 100%, while that of the PSL test particle is -23.5 mV at pH 7. The removal efficiency of the electro-positively charged filter is 98% for PSL particles of 0.11 ${\mu}m$, while that of the negatively charged filter is 7%. The positively charged filter media showed the potential to be an effective method for removing fine particles from the contaminated water for liquid filtration.

세척용 구형입자 순환에 따른 활성슬러지내 침지식 평막의 막간차압 (Transmembrane Pressures for the Submerged Flat Membrane in the Activated Sludge Solution by Circulation of the Cleaning Spherical Beads)

  • 정도인;민지수;이수민;정건용
    • 멤브레인
    • /
    • 제28권1호
    • /
    • pp.62-66
    • /
    • 2018
  • 본 연구에서는 순수와 유사한 밀도의 세척형 구형 입자를 제작하고 순수 수조 내에서 산기량 및 입자 농도에 따른 입자의 유동 속도를 측정하였다. 세척형 구형 입자 1~3%를 MLSS 8,000 mg/L인 활성슬러지 용액에 주입하고 20 LMH 및 산기량 500 mL/min 조건에서 FR 및 SFCO 모드로 동시에 투과 실험하였다. 사용한 분리막은 유효 막면적이 $90cm^2$, 공칭 세공크기가 $0.4{\mu}m$인 평막이다. 입자 농도가 증가할수록 TMP가 감소하였으며 FR 모드, 입자 농도 2%일 때 가장 효과적인 것으로 확인되었다.

정수장의 노후 급속 모래여과지 진단 및 개량 (Diagnosis and Renovation of a Time-worn Rapid Sand Filter used for Drinking Water Treatment)

  • 김상구;박현석;손희종;이정규;류동춘;유평종
    • 한국환경과학회지
    • /
    • 제25권7호
    • /
    • pp.999-1005
    • /
    • 2016
  • The H water treatment plant has been operating since 1982 and has had no renovation. It is assumed that the filters have been operated for more than 30 years and therefore are deteriorated. Many of the filters show an unequal state of air scouring during backwashing. For this study one filter, which was presumed most deteriorated among eighteen filters, was selected as a model filter for renovation. Some of the effects seen after renovation of the underdrain system were a lower average filtrated turbidity by approximately 0.02 NTU and an equal backwash state throughout the filter bed. Sand wash efficiencies by backwash before renovation of the underdrain system were 28%, 8%, and 5% at the surface, 50 cm depth, and 100 cm depth, respectively, and after renovation of the underdrain system were 94%, 26%, and 15%, respectively. The standard deviation of the effective sand size was 0.025-0.033 mm before renovation of the underdrain system and 0.002-0.011 mm after renovation of the underdrain system, meanings there was equal backwash pressure throughout the filter. Filtration time after renovation was approximately 2 times longer than before renovation.

다당류 생산공정에서의 청정기술개발에 관한 연구 (A Study on the development of cleaner production technology in the production of polysaccharide)

  • 전용보;김경수;배우근
    • 유기물자원화
    • /
    • 제11권3호
    • /
    • pp.51-59
    • /
    • 2003
  • 본 연구에서는 베타글루칸 생산공정에서 발생하는 공정수에 대한 M/F(micro filtration) 분리막 시스템의 효용성을 검토하였다. M/F 시스템의 운전을 위하여 M/F 분리막은 Millipore(USA)사의 Pellicon 2 Cassette Filter Module HVMP $0.45{\mu}m$를 사용하였다. 플럭스는 운전압력의 상승에 따라서는 증가하며, 운전시간의 경과에 따라서는 감소하였다. 농축비가 높을수록 농축액에 남아있는 베타글루칸 제품의 회수가 효과적이었다. 베타글루칸 발효액의 재이용시 투과액의 전환수율이 42.5%로 배양 패턴에 큰 변화가 없었다. 본 연구에서 얻어진 결과를 토대로 청정생산공정에서 투과액을 반응공정수로 재이용 가능하리라 판단된다.

  • PDF

Evaluation of flux stabilisation using Bio-UF membrane filter on KZN Rivers, South Africa

  • Thoola, Maipato I.;Rathilal, Sudesh;Pillay, Lingam V.
    • Membrane and Water Treatment
    • /
    • 제7권4호
    • /
    • pp.313-325
    • /
    • 2016
  • South Africa recognises piped water as the main source of safe drinking water supply. Remote areas do not have access to this resource and they rely solely on surface water for survival, which exposes them to waterborne diseases. Interim point of use solutions are not practiced due to their laboriousness and alteration of the taste. Bio-ultra low pressure driven membrane system has been noted to be able to produce stable fluxes after one week of operation; however, there is limited literature on South African waters. This study was conducted on three rivers namely; Umgeni, Umbilo and Tugela. Three laboratory systems were setup to evaluate the performance of the technology in terms of producing stable fluxes and water that is compliant with the WHO 2008 drinking water guideline with regards to turbidity, total coliforms and E.coli. The obtained flux rate trends were similar to those noted in literature where they are referred to as stable fluxes. However, when further comparing the obtained fluxes to the normal dead-end filtration curve, it was noted that both the Umbilo and Tugela Rivers responded similarly to a normal dead-end filtration curve. The Umgeni River was noted to produce flux rates which were higher than those obtainable under normal dead-end. It can be concluded that there was no stabilisation of flux noted. However, feed water with low E.coli and turbidity concentrations enhances the flux rates. The technology was noted to produce water of less than 1 NTU and 100% removal efficiency for E.coli and total coliforms.

UF pretreatment at elevated temperature within the scheme of hybrid desalination: Performance and environmental impact

  • Agashichev, Sergey;Kumar, Jayesh
    • Membrane and Water Treatment
    • /
    • 제8권3호
    • /
    • pp.279-292
    • /
    • 2017
  • This study was aimed at ultrafiltration (UF) as a pretreatment before reverse osmosis (RO) within the scheme of hybrid reverse osmosis-multistage flush (RO-MSF) desalination. Seawater at elevated temperature (after MSF heat-exchangers) was used as a feed in this process. The pretreatment system was represented as a set of functionally-linked technological segments such as: UF filtration, backwashing, chemical- enhanced backwashing, cleaning, waste disposal, etc. The process represents the sequences of operating cycles. The cycle, in turn, consists of the following unit operations: filtration, backwashing and chemical-enhanced backwashing (CEB). Quantitative assessment was based on the following indicators: normalized permeability, transmembrane pressure, specific energy and water consumption, specific waste generation. UF pre-treatment is accompanied by the following waste streams: $W1=1.19{\times}10$ power of $-2m^3$ (disposed NaOCl with 0.0044% wt.)/$m^3$ (filtrate); $W2=5.95{\times}10$ power of $-3m^3$ (disposed $H_2SO_4$ with 0.052% wt.)/$m^3$(filtrate); $W3=7.26{\times}10$ power of $-2m^3$ (disposed sea water)/$m^3$ (filtrate). Specific energy consumption is $1.11{\times}10$ power of $-1kWh/m^3$ (filtrate). The indicators evaluated over the cycles with conventional (non-chemical) backwashing were compared with the cycles accompanied by CEB. A positive impact of CEB on performance indicators was demonstrated namely: normalized UF resistance remains unchanged within the regime accompanied by CEB, whereas the lack of CEB results in 30% of its growth. Those quantitative indicators can be incorporated into the target function for solving different optimization problems. They can be used in the software for optimisation of operating regimes or in the synthesis of optimal flow- diagram. The cycle characteristics, process parameters and water quality data are attached.