• 제목/요약/키워드: Filtration plant

검색결과 269건 처리시간 0.037초

Status of Membrane Filtration in Japan : Application for Water Supply

  • Minami, Katsuyoshi
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 심포지움시리즈 Jan-97 수처리용 분리막 기술 및 응용
    • /
    • pp.55-62
    • /
    • 1997
  • In Japan, the membrane filtration is becoming a common technology for municipal water supply system especially for small plant. 6 years before (1991), the national research project of membrane filtration for small plant has started. The project was named as "MAC 21", MEMBRANE AQUA CENTURY 21. In the project the Ministry of Health and Welfare, 8 universities and 18 water treatment plant companies have been involved. This was the first attempt to research a common theme in joint with government, universities and private companies. After three years, the guide line for membrane filtration application for small plant has been established. This has promoted to install some actual plant. And also, another joint research for "RESEARCH OF MEMBRANE FILTRATION FOR ADVANCED WATER TREATMENT" has started in 1994 and completed in March, 1997. The project was named as MAC21. In the former project the main objectives were removal of turbidity and bacteria from water. However, in new project the objective was establishment of the further advanced membrane filtration technology which would be applicable for trace chemical components removal such as tri-halo-methane pre-courser, agricultural chemicals removal, offensive smell and taste removal and virus removal. For the objectives, application of nanofiltration and hybrid-system, a combination of micro-filtration ultra-filtration with biological, ozone and activated carbon treatment process have been studied. In addition, application of membrane filtration for treatment of back-wash waste water originated from membrane filters and conventional sand filters has.been studied. At the end of March of this year, about 30 membrane filtration plants are actually supplying the water, the total treatment capacity is about 6,000 m$^{3}$/day and another 20 will be installed within one year.led within one year.

  • PDF

정수처리장내 급속모래 여과지의 이단복합여과시스템으로의 개량 (Improvement of Rapid Sand Filtration to Two Stage Dual Media Filtration System in Water Treatment Plant)

  • 우달식;황규원;김준언;황병기;조관형
    • 한국환경보건학회지
    • /
    • 제37권2호
    • /
    • pp.141-149
    • /
    • 2011
  • This study aimed for developing a two stage dual media filtration system. It has a sand and activated carbon layer above the under-drain system, and a sand layer above the middle-drain system for pretreatment. When retrofitting an old sand filter bed or designing a new one, this technology can substitute the existing sand filter bed without requiring a new plant site. The removal rate of total particle is 93, and 3~7 ${\mu}m$ and 5~15 ${\mu}m$ particles are all 97%. These high removal efficiencies of each pollutant due to adsorption and biological oxidation in activated carbon filter layer. The best backwashing method of two stage dual media filtration system is ascertained by air injection, air + water injection and water injection sequence. In this study, a pilot plant of two stage and dual filtration system was operated for 4 months in water treatment plant. The stability of turbidity was maintained below 1 NTU. The TOC, THMFP and HAAFP were removed about 90% by two stage and dual media filtration system, which is almost 2 times higher than existing water treatment plant.

고도정수처리에서 사여과와 정밀여과의 유기물처리특성에 관한 연구 (Treatment Characteristics of Sand Filtration and Microfiltration (MF) in Advanced Water Treatment)

  • 김형석;이병호
    • 상하수도학회지
    • /
    • 제24권6호
    • /
    • pp.723-734
    • /
    • 2010
  • With a belief of high water quality production and less chemical usage, membrane technology including Microfiltration (MF), Ultrafiltration (UF), and Nanofiltration(NF) is being employed more and more in drinking water treatment process. However, due to higher energy consumption of UF and NF, MF is normally used for drinking water treatment especially in a plant of large scale. In this investigation, performance ofsand filtration and membrane filtration was compared regarding removal of various water quality parameters, such as TOC, DOC, KMnO4 consumption, THMFP, and HAAFP. Two lines of pilot plant have been operated, one of which line is a traditional advanced water treatment process which includes sedimentation, sand filtration, ozonation, and activated carbon, and the other line is an alternative treatment process which includes sedimentation with inclined plate, MF membrane, ozonation, and activated carbon. For the first about 4months of period, MF filtration showed similar or little bit higher performance than sand filtration. However, after about 4month later, sand filtration showed much higher performance in removing all parameters monitored in the investigation. It was found that sand filtration is a better option than MF filtration as far as microbial community is fully activated in sand filter bed.

한국형 IGCC 대용량 집진시스템 개발 (Development of Filtration System for Korean Model IGCC Demonstation Plant)

  • 박석주;임경수;임정환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.812-815
    • /
    • 2007
  • Computational simulation has been performed to design the filtration system for Korea model IGCC demonstration plant. The filtration system for optimal design has four effective filters corresponding to the clusters composed of a group of ceramic candle filters. It was analyzed how the different entrance geometry influences the flow field and the particle behavior in the filtration system. The particle loading is minimum when the gas mixed with particles flows into the filter vessel with a shroud tube through a tangential inlet. However, the particle loading is maximum when the gas with particles enters the filter vessel through a normal inlet which a entrance tube extended from. By controling adequately both conditions of inflow, the filtration system can be operated optimally to prolong the filter life-time and to save the energy for cleaning filters.

  • PDF

하수처리장 방류수를 이용한 인공함양 가능성 평가

  • 김병군;서인석;홍성택;김형수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.257-260
    • /
    • 2002
  • The main purpose of this research is to find suitable treatment methods of wastewater effluent for artificial recharge. For this purpose, we search the effluent quality of wastewater treatment plant and possibility of additional filtration process. Particles ranged 2 ~ 5 ${\mu}{\textrm}{m}$ and 15~20 ${\mu}{\textrm}{m}$ in "T" WWTP(Waste Water Treatment Plant) effluent were relatively dominant. In dual-media filtration system operation, head-loss development of column 1 was about two times faster than column 2, and head-loss development within 5 cm from surface was very important factor in operation, Conclusively, for the stable filtration and running time of 1.5~2 day, influent turbidity must keep 5 NTU or below, and filtration system must operated at 280 m/day or below. After filtration of WWTP effluent, water quality reached satisfactory level. This water has potential of agricultural reusing, flushing water in building, recharging water to river or stream at dry season and artificial recharge of ground water.und water.

  • PDF

완속여과 공정에서 표층 생물막 생성 및 제어와 원인조류 규명 (Analysis and effectiveness of biological thin Layer (Schmutzdecke) on the sand surface in slow sand filtration processes)

  • 김성수;박노석;김충환;박종근
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.289-298
    • /
    • 2008
  • Because of their simplicity, efficiency, and economy, slow sand filters are appropriate means of water treatment for small water systems. Biological activity within the sand bed have the strongest influence on removal efficiency of pollutants by slow sand filtration. This report investigated the microorganisms(algae) of slow sand filtration pilot plant at Y water treatment plant. Data were collected at inflow and slow sand filtration from May to October, 2007. The results indicated that the light exposure was influenced on microorganism in slow sand filtration according to the formation of algal biofilm. The relative contribution of biomass and accumulated particulates to head loss development in slow sand filters requires further study.

정수처리장 사여과지의 이단이중여과재 시스템으로의 개량 (Improvement of Rapid Sand Filtration to Two Stage Dual Media Filtration System in Water Treatment Plant)

  • 우달식;김준언;황병기;채수권;조관형
    • 한국환경과학회지
    • /
    • 제23권4호
    • /
    • pp.737-742
    • /
    • 2014
  • This study aimed for evaluating the applicability of the two stage dual media filtration system in field water treatment plant. The field plant of two stage and dual media filtration system was operated for 2 months. Average iron concentrations of the settled water, existing filtered water and second stage filtered water was 0.041 mg/L, 0.007 mg/L and 0.005 mg/L, respectively. Removal efficiency of iron concentration in the second stage is appropriately 35% more than in existing filtered water. Also removal efficiency of residual chlorine in the dual media filtration system is relatively 42.3% more than in existing filtered water due to adsorption of activated carbon, but the removal of ammonia nitrogen by adsorption is insufficient. Average concentrations of THM and chloroform in the settled water are 0.033 mg/L, 0.026 mg/L, respectively and in existing filtered water are 0.023 mg/L and 0.023 mg/L. Average concentrations of THM and chloroform in the dual media filtration system are 0.008 mg/L and 0.013 mg/L. Therefore removal efficiency of THM concentration in second stage is more than 66.4% in existing filtrated water. Also removal efficiency of chloroform in the dual media filtration system is more than 50.0% in existing filtered water because of the adsorption of activated carbon. In this case backwashing period in dual stage system is 4~5 days, but in existing filtration system is 1~2 days.

처리수 재이용을 위한 최종침전지 유출수의 급속여과공정 처리특성 (Treatment Characteristics of Rapid filtration Process treating Secondary Clarifier Effluent for Wastewater Reuse)

  • 한동우
    • 한국수자원학회논문집
    • /
    • 제35권2호
    • /
    • pp.213-220
    • /
    • 2002
  • 하수 처리수의 재이용을 위하여 표준활성슬러지법에 의한 생물학적 처리 후 최종침전지 유출수를 급속여과공정으로 처리하기 위한 Pilot Plant 실험연구가 수행되었다. 또한, 활성슬러지와 연계된 급속여과공정과 포기조 후단에 응집제를 주입하는 활성슬러지 이후 급속여과 처리하는 공정과의 비교 실험도 행해졌다. 최종침전지 유출수를 급속여과공정으로 처리한 경우 여과속도는 100m/day, 여과지속시간은 40시간 이하로 운전하는 것이 타당한 것으로 나타났으며, 여과지의 역세척 주기는 여과속도 100m/day일 때 40시간에 1회 정도가 되었다. 여과지 역세척 시 역세척 방법은 공세 1분, 공세+수세 30초, 수세 1분, 공세·수세 2분, 수세 3분, 안정 30초, 배수 10분의 순으로 행하는 것이 효과적이었으며, 수세속도는 10LPM으로 전체 여과수량의 2%정도였다. 표준활성슬러지 시스템에 의한 2차 처리수를 잡용수로 재이용 하기 위해서는 폭기조 후단에 응집제를 첨가하여 여과 공정을 후속공정으로 하는 시스템으로 유용하게 사용할 수 있을 것으로 판단된다.

급속여과공정에서의 여과보조제 사용에 따른 여과특성 (Characteristics of High-Rate Filtration with Filtration Aids)

  • 안종호;윤재흥
    • 상하수도학회지
    • /
    • 제14권3호
    • /
    • pp.260-270
    • /
    • 2000
  • The objective of this study is to evaluate the effect of filter aids in the dual-media rapid filtration. Paper-filter tests were conducted to determine the proper dosages of coagulant and filter aid, and pilot plant tests using two dual-media filter columns were performed for a variety of filtration rates. Using a filter aid (non-ionic polymer), the maximum feasible filtration rate is 480m/day, while turbidity is less than 0.3 NTU and filter run-time is about 70 hours. It is possible to increase the filtration rate up to 360 m/day for keeping the turbidity less than 0.1 NTU. Turbidity increases for the filtration rate greater than 360m/day. In general, the quality of filtered water with a filter aid is stable, while the filter maintains a sufficient filter run-time for a maximum allowable head loss. Particularly, the initial breakthrough can be effectively controlled. The use of a filter aid may be one of the methods applicable if the turbidity of filtered water is required to be improved or if the filter breakthrough limits filter run-time.

  • PDF

Comparison of Gene Coding Clones Content in In vivo and In vitro Methyl-Filtration Libraries of Maize(Zea may)

  • Lee, Myung-Chul;Wing, Rod A;Suh, Seok-Cheol;Eun, Moo-Young
    • 한국자원식물학회지
    • /
    • 제20권6호
    • /
    • pp.491-498
    • /
    • 2007
  • It has been hypothesized that efficient exclusion of methylated retrotransposons and repeated DNA region is one of the rapid and cost-effective approaches for comprehensive gene discovery in large genome size of maize. Three kinds of methylation-sensitive restriction enzymes, HapII, MspI and McrBC, were used to identify the restriction frequency of cytosine methylation sites in maize genome. Roughly 60% of total maize genomic DNA was restricted less than 500bp by McrBC, and the most of restricted small size fraction was composed retrotransposon. In order to validate the efficient construction of gene-rich shotgun library, we compare two gene-rich methyl-filtration shotgun libraries using in vivo and in vitro methyl-filtration system. The size selected DNA fraction by Sau3A-McrBC enzyme treated was very stable and has not appeared modification in E. coli, but most insert DNA size of partially digested with Sau3A were decrease less than 500bp by bacterial methylation-modification system. In compare of retroelements portion, A 44.6% of the sequences were retroelement in unmethyl-filtered library, and the most of them was Copia type, such as Prem, Opie and Ji. The portion of retroelement was drastically decreased to 25% and 20% by in vivo and in vitro filtration system, respectively.