• 제목/요약/키워드: Filtration Tests

검색결과 107건 처리시간 0.026초

강변 대수층 매질 시료의 오염물질 지연능 평가 (Evaluation of Contaminant Retardation Capacities of Bank Aquifer Materials)

  • 김재영;오동익;박동운
    • 상하수도학회지
    • /
    • 제13권4호
    • /
    • pp.62-71
    • /
    • 1999
  • The containment retardation capacities of four different aquifers were evaluated in a preliminary study for development of bank filtration in the Young San river area. $NO_3-N$, $NO_2-N$, $NH_4^+-N$, Fe, Mn, phenol, and chloride were selected as the target contaminants and a nonreactive tracer, respectively. Batch isotherm tests were conducted to measure the partition coefficients of the target contaminants. The mass transport parameters of nonreactive tracer were estimated from column tests. From the results of bath isotherm tests, it was shown that lower stream aquifer materials have greater partition coefficients of $NO_3-N$, $NH_4^+-N$, Mn, and phenol than the upper stream aquifer materials; however, there was no significant position-dependent trend for Fe. All aquifer materials tested have the same range of partition coefficients for $NO_2-N$. Column tests showed that the molecular diffusion of Cl- was much less than the mechanical dispersion; and there was no significant difference between the estimated dispersivities of tested aquifer materials. Consequently, it seems that the difference in the containment retardation capacities between four aquifers tested in this study would primarily result not from hydrodynamic dispersion but from partitioning.

  • PDF

대기공 정밀여과막의 수처리 응용 및 문제점 (Water Treatment Application of a Large Pore Micro-Filtration Membrane and Its Problems)

  • 윤창한;김정학;이강원;박성호
    • 멤브레인
    • /
    • 제24권3호
    • /
    • pp.194-200
    • /
    • 2014
  • 본 연구의 목적은 대기공 정밀여과(Large Pore Micro-Filtration, LPMF)막의 수처리 응용을 위한 실험실 규모에서의 성능을 평가한 것으로 이를 통해 문제점 및 해결방안을 제시하는 것이다. 본 연구에 사용된 평균 기공이 $5{\mu}m$ LPMF막은 PET Braid가 보강되어 있는 PVDF 재질의 외압형 중공사막으로 여과실험은 30 cm의 수두차 혹은 1.5 bar 이하의 압력차로 수행하였으며, 역세는 여과수에 압축공기로 약 4 bar의 압력을 가한 후 수초 내에 순간 역세하는 가압역세였다. 0.2 bar의 TMP (Trans Membrane Pressure)에서 $0.05{\mu}m$ UF로 전처리한 시수로 $0.4{\mu}m$의 MF와 flux를 비교한 결과 UF에 비해 LPMF의 flux가 약 2배 정도 높았으며, 동일한 시수에 대해 15~30 cm의 수두차에 따른 flux를 측정한 결과 30 cm 수두차에서 800 LMH 이상의 높은 flux를 확인하였다. 또한 여과수의 탁도 향상과 여과 flux의 안정적 유지를 위해 여러 가지 무기응집제에 대한 $5{\mu}m$ 기공의 여지를 이용한 Time-To-Filter (TTF)를 통해 적정 응집제 및 그 주입량을 결정하였다. 고농도 무기응집제 주입 및 30 cm 이상의 수두차로 LPMF를 중력식으로 운전하였을 때 flux는 80 LMH 이상이었고, 탁도 제거율은 93.5~99.5%이었다. 특히 약 4 bar의 압력의 순간 가압역세를 한 결과 막의 충진율이 19%인 경우 여과수의 회수율을 약 97%로 유지하면서도 여과 flux가 안정적으로 유지되었으나, 막충진율을 약 43%인 경우 순간 가압역세만으로는 역세가 불안정하였던 관계로 여과압력이 지속적으로 상승하는 등의 여과공정이 불안정한 문제점을 보였다.

Correlation between microleakage and screw loosening at implant-abutment connection

  • Sahin, Cem;Ayyildiz, Simel
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.35-38
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS. Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titanium) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (${\alpha}=0.05$). RESULTS. Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION. Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.

대형 사력댐에서의 전단파속도 평가를 위한 단측선 빔형성기법 (Short-Array Beamforming Technique for the Investigation of Shear-Wave Velocity at Large Rockfill Dams)

  • 조성호;나디아
    • 대한토목학회논문집
    • /
    • 제33권1호
    • /
    • pp.207-218
    • /
    • 2013
  • 대형 사력댐의 내진성능 평가에서 필히 요구되는 입력상수는 사력재료, 코아매질의 전단파 속도이다. 이를 표면파 시험으로 평가하기 위해서는 사력골재의 불연속, 매질의 비균질, 사면 경계면 등 표면파 시험결과의 신뢰도를 떨어뜨리는 조건을 극복해야 한다. 본 연구에서는 이러한 표면파시험의 한계를 극복하기 위하여 기존 빔형성기법의 원리를 응용한 SBF (Short-Array Beamforming) 기법을 제안하였다. SBF 기법은 3~9 m의 짧은 측선과 원거리 발진원을 이용함으로써, 빔형성기법 고유의 장점인 측정자료의 자동화분석뿐만 아니라 근접장 문제의 해결, 국부적 이상대의 발견 등의 기능을 가지도록 개발되었다. 본 연구에서는 이러한 SBF 기법과 IRF(Impulse-Response Filtration) 기법을 활용하여 대형 사력댐의 전단파속도를 신뢰성 있게 평가하는 방법을 정립하였다. 정립된 기법은 사력댐의 사력재료와 유사한 암버럭으로 매립 성토된 철도 노반에서 다운홀 시험, CapSASW (Common-Array-Profiling SASW) 시험과의 비교를 통하여 그 신뢰성과 실용성을 검증하였다.

태영 침지식 막여과 고도정수처리 (Taeyoung Submerged-type Membrane Filtration for Advanced Drinking Water Treatment)

  • 연경호;조재범;이윤규;강호정;김우구
    • 한국지반환경공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.15-27
    • /
    • 2013
  • 본 연구에서는 대구 G정수장 막여과 정수처리시설을 계획하기 위해 원수수질 처리에 적합하고 경제적인 시스템을 적용하고자 현장모형실험을 통하여 동절기를 포함한 6개월 동안의 연속운전에 따른 수량과 수질, 그리고 공정의 안정성을 평가하였다. 환경부 막여과 정수시설의 설치기준에 의해 실시된 현장모형실험에서 1계열 목표수질 검증설비와 2계열 막공정 평가설비로 나누어 2계열로 수행되었다. 공정수질은 탁도 0.03 NTU 이하로서, 증류수 수질의 탁도를 나타내었으며 먹는 물 수질기준을 모두 충족하였다. 공정운전에서 99%의 회수율로 안정된 막차압을 나타내어 공정운전에 수질 및 수온 등의 영향에 대비한 공정설계가 되었음을 확인하였다. 따라서 지속적인 기술개발을 통해 설계 및 시공 노하우에 대한 지속적인 경험이 축적되어 막여과 고도정수처리 기술에 대한 엔지니어링 원천기술을 확립하고자 한다.

맥동식 침전지에서 맛·냄새 유발물질 제거 특성 (Removal Property of Taste and Odor Causing Material in Pulsator Clarifier)

  • 정일용;차민환
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.104-109
    • /
    • 2011
  • The removal efficiencies of 2-methylisoborneol (MIB) and geosmin were investigated to reveal removal characteristics of typical organic compounds causing disagreeable taste and odor at the conventional water treatment plant installed with pulsator clarifier patented by the French company $Degr{\acute{e}}mont$. The injection rate of Powdered Activated Carbon (PAC) into water was changed step wisely as we conducted jar tests in the laboratory and water treatment in the actual plant. 2-MIB concentration decreased linearly while geosmin did exponentially along with the injection rate of PAC at our jar tests. The removal efficiency of geosmin by PAC injection was considerably higher than that of 2-MIB. In the real pulsator clarifier, 2-MIB concentration started decreasing as the injection rate reached up to 10 mg/L of PAC. On the other hand, the concentration of geosmin in water decreased proportional to the injection rate of PAC. In the sand filtration, removal efficiencies of 2-MIB and geosmin on July were much higher than those on March. It was carefully suggested beforehand and found afterwards that general microorganisms notably existed in the sand filter with no chlorine in filter influent and backwash water and the sand filter biologically activated removed much more odor compounds. It was considered as the reason why the removal efficiency of 2-MIB and geosmin was increased. The microbial activity maybe increased in summer with water temperature rising and low filtration rate possibly increased contact time between odor compounds and general microorganisms.

고함수비물질의 탈수에 대한 지오텍스타일 튜브의 실험적 평가 (Laboratory Assessment of Geotextile Tube for Dewatering High Water Content Material)

  • Mo, Xinghua;Kim Tae-Hyung;Moo-Young. Horace K
    • 한국지반공학회논문집
    • /
    • 제18권5호
    • /
    • pp.261-269
    • /
    • 2002
  • 본 논문에서 고함수비 슬러지나 퇴적물들의 탈수에 지오텍스타일 튜브들의 이용이 연구되었고, 튜브들의 사용에 대한 실용성과 영향을 미치는 요인들도 평가되었다. 개조된 실험기를 사용하여 고함수비물질들과 두종류의 woven지오텍스타일 튜브에 대해서 압력여과시험들이 실험되었다. 실험결과, 1) 지오텍스타일 튜브안쪽에 형성된 필터케익이 튜브안에서 세립자 유지의 주 원인이며, 또한 튜브의 투수율 감수의 원인이고, 2) 필터케익형성을 조정해서 토사유지율과 투수율사이의 균형을 얻는것이 성공적인 지오텍스타일 튜브사용에 가장 중요한 것이며, 3) 지오텍스타일, 슬러지 특성, 여과압력등이 탈수효과 및 탈수율에 영향을 미침을 알 수 있었다

열안정 공기 여과막용 폴리페닐렌 설파이드 원단과 폴리테트라플루오로에틸렌 필름 사이의 접착력 향상 (Enhancing Adhesion between Polyphenylene Sulfide Fabric and Polytetrafluoroethylene Film for Thermally Stable Air Filtration Membrane)

  • 김진욱;손혜정;강상훈;이창수
    • 멤브레인
    • /
    • 제33권4호
    • /
    • pp.201-210
    • /
    • 2023
  • 먼지 필터 막은 인간의 건강, 안전 및 환경 보호의 몇 가지 중요한 측면에 기여하기 때문에 인간의 삶과 다양한 산업에서 중요한 역할을 한다. 이 연구는 고온 조건에 대한 우수한 열안정성과 접착 특성을 가진 polysulfone@polyphenylene sulfide/polytetrafluoroethylene (PSf@PPS/ePTFE) 복합 먼지 필터 막의 개발을 제시한다. FT-IR 분석은 PSF 접착제가 PPS 직물에 성공적으로 함침되고 ePTFE 지지체와의 상호 작용을 확인한다. FE-SEM 이미지는 향상된 섬유 상호 연결 및 PSf 농도와 함께 접착력을 보여준다. PSf@PPS/ePTFE-5는 가장 적합한 다공성 구조를 보여준다. 복합 막은 400℃까지 예외적인 열 안정성을 보여준다. 박리 저항 테스트는 먼지 여과에 대한 충분한 접착력을 보여 공기 투과성을 희생시키지 않고 힘든 고온조건에서 신뢰할 수 있는 성능을 보장한다. 이 막은 산업 응용 분야에서 유망한 잠재력을 제공한다. 더 나아가 최적화 및 응용 가능성을 탐구할 수 있다.

망간모래여과공정에서 망간제거에 미치는 영향인자 (Effect of Experimental Factors on Manganese Removal in Manganese Sand Filtration)

  • 김범수;윤재경;안효원;김충환
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.86-93
    • /
    • 2006
  • In the drinking water treatment, the aesthetic and color problem are caused by the manganese which is occurring and present in the surface, lake and ground water. The most common treatment processes for removing manganese are known for oxidation followed by filtration. In this study, the manganese sand process was used for removing manganese with river bank filtrate as a source. In the manganese sand process, the residual chlorine and pH are important factors on the continuous manganese oxidation. In addition, space velocity (SV) and alum dosage are play a role of manganese removal. Even though manganese removal increased with increasing chlorine concentration, the control of residual chlorine is actually difficult in this process As the results of tests, the residual chlorine concentration as well as manganese removal were effectively achieved at pH 7.5. The optimum attached manganese concentration on manganese sand was confirmed to 0.3mg/L by the experimental result of a typical sand converting to manganese sand.

Treatment of Industrial Wastewater with High Concentration of Hydrocarbons Using Membrane Reactors

  • Bienati, B.;Bottino, A.;Comite, A.;Ferrari, F.;Firpo, R.;Capannelli, G.
    • 멤브레인
    • /
    • 제17권2호
    • /
    • pp.112-117
    • /
    • 2007
  • The application of membrane bioreactors for the depuration of wastewater coming from the washing of mineral oil storage tanks is described. Microfiltration hollow-fibre membranes were used in the submerged configuration. Filtration tests were carried out with a biomass concentration of about 15 g/L in order to assess the critical flux of the hollow fibre membrane used. Then particular care was taken in carrying out the performance runs in the sub-critical flux region. The reactor performance was very high, with removal efficiencies ranging between 93% and 97% also when the concentration of hydrocarbon was very high. Some kinetic parameters for the COD and the hydrocarbon removal were estimated.