• Title/Summary/Keyword: Filtration

Search Result 3,344, Processing Time 0.034 seconds

A Study on the Water Reuse Systems (중수도개발연구(中水道開發研究))

  • Park, Chung Hyun;Lee, Seong Key;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.113-125
    • /
    • 1984
  • Water supply has been mainly dependent on the construction of the dams in Korea. It is difficult, however, to continue to construct dams for many reasons, such as the decrease of construction sites, the increase of construction costs, the compensation of residents in flooded areas, and the environmental effects. Water demands have increased and are expected to continue increasing due to the concentration of people in the cities, the rise of the living standard, and rapid industrial growth. It is acutely important to find countermeasures such as development of ground water, desalination, and recycling of waste water to cope with increasing water demands. Recycling waste water includes all means of supplying non-potable water for their respective usages with proper water quality which is not the same quality as potable water. The usages of the recycled water include toilet flushing, air conditioning, car washing, yard watering, road cleaning, park sprinkling, and fire fighting, etc. Raw water for recycling is obtained from drainage water from buildings, toilets, and cooling towers, treated waste water, polluted rivers, ground water, reinfall, etc. The water quantity must be considered as well as its quality in selecting raw water for the recycling. The types of recycling may be classified roughly into closed recycle systems and open recycle systems, which can be further subdivided into individual recycle systems, regional recycle systems and large scale recycle system. The treatment methods of wastewater combine biochemical and physiochemical methods. The former includes activated sludge treatment, bio-disc treatment, and contact aeration treatment, and the latter contains sedimentation, sand filtration, activated carbon adsorption, ozone treatment, chlorination, and membrane filter. The recycling patterns in other countries were investigated and the effects of the recycling were divided into direct and indirect effects. The problems of water reuse in recycle patterns were also studied. The problems include technological, sanitary, and operational problems as well as cost and legislative ones. The duties of installation and administrative organization, structural standards for reuse of water, maintenance and financial disposal were also studied.

  • PDF

Study on Permeability, Optimum Yield and Long-term Stability in Alluvial Well with Filter Layer Change (충적우물에서 필터층 변화에 따른 투수특성, 적정양수량 및 장기적 안정성에 대한 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Kim, Ki-Joon;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.101-115
    • /
    • 2018
  • This study was carried out to evaluate the effects of various filter conditions on unconfined aquifer (alluvial aquifer). We made model test device which has filter layer, pumping well and observation well which consist of sand layer and gravel layer to test. Step drawdown test and long term pumping tests were carried out using the device. The permeability characteristics of each test group were confirmed and the optimal yield was calculated. As a result of comparing the optimal yield of double filter and single filter in sand, dual-filter SD-300 was valued at 216.8 % higher final optimal yield than single-filter SS-300. Comparing the dual filter SD-300 and the single filter SS-100 with a thin filter layer, dual-filter SD-300 was valued at 709.2% higher final optimal yield than single-filter SS-300. As a result of analysis of optimal yield change over time, It was confirmed that the ratio of optimal yield of single filter and dual filter increase over time. In order to evaluate the long-term change in water intake efficiency, we considered the point at which the initial optimal yield was reduced by 50%. The dual filter SD-300 is about 351.1% higher than SS-300, which is the same thickness filter, and about 579.0% higher than SS-100. From these results, Assuming that the point at which the initial quantity of water intake is reduced to 50% is the well life, double filters are expected to increase their lifespan by about 3.5 times over single filters of the same thickness and by about 5.8 times over typical single filter. These results can be used to design wells to river bank filtration or filtered seawater. In addition, it is possible to clarify the effect of the double filter through the comparison with the future field test results.

Comparisons of Regeneration Methods Using Physical and Chemical Treatment for Phosphate Removal Restoration of Filter Media (여재의 인 제거기능 회복을 위한 물리화학적 재사용 방안 비교)

  • Kim, Ji Ah;Choi, I Song;Oh, Jong Min;Kim, Won Jae;Park, Jae Roh
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • The purpose of this study is to find the regeneration method of filter media using physical and chemical treatment for restoration of phosphorus adsorption ability. The filtration material used in this study is called Adphos. In an experiment of heating treatment, re-used filter media is heated to a high temperature before the adsorption test. The results show that the $PO{_4}^{3-}-P$ adsorption capacity is in the range of 0.0021 - 0.0030 mg/g and the removal efficiency is in the range of 26.1 - 39.4%. In the experiment of acid or basic treatment, re-used filter media is exposed to a different pH condition before the adsorption test. The results show that the $PO_4^{3-}-P$ adsorption capacity is in the range of 0.0010 - 0.0066 mg/g and the removal efficiency is in the range of 15.8 - 87.1% after the acid treatments which have pH values of 1 - 5. However, after the basic treatments which have pH values of 8 - 11, the results show that the $PO{_4}^{3-}-P$ adsorption capacity is in the range of 0.0018 - 0.0034 mg/g and the removal efficiency is in the range of 26.7 - 48.0%. In an experiment of chemical treatment using NaCl, re-used filter media was exposed to a different NaCl concentration before the adsorption test. The results show that the $PO{_4}^{3-}-P$ adsorption capacity is in the range of 0.0036 - 0.0050 mg/g and the removal efficiency is in the range of 50.5 - 71.1%. In conclusion, chemical treatment using NaCl shows a high recovery probability of phosphorus adsorption ability of filter media.

Effects of High Glucose and Advanced Glycosylation Endproducts (AGE) on ZO-1 Expression in cultured Glomerular Epithelial Cells (GEpC) (당과 후기당화합물에 의한 사구체 상피세포 ZO-1 발현의 변화)

  • Lee Jin-Seok;Lee Hae- Soo;Yoon Ok-Ja;Ha Tae-Sun
    • Childhood Kidney Diseases
    • /
    • v.8 no.2
    • /
    • pp.138-148
    • /
    • 2004
  • Purpose: Regardless of the underlying diseases, the proteinuric condition demonstrates ultrastructural changes in podocytes with retraction and effacement of the highly specialized interdigitating foot processes. We examined the molecular basis for this alteration of the podocyte phenotypes, including quantitative and distributional changes of ZO-1 protein as a candidate contributing to the pathogenic changes in the barrier to protein filtration. Methods: To investigate whether high glucose and advanced glycosylation endproduct(AGE) induce podocyte cytoskeletal changes, we cultured rat GEpC under 1) normal glucose(5 mM=control) or 2) high glucose(30 mM) or 3) AGE-added or 4) high glucose plus AGE-added conditions. The distribution of ZO-1 was observed by confocal microscope and the change of ZO-1 expression was measured by Western blotting and RT-PCR. Results: By confocal microscopy, we observed that ZO-1 moves from peripheral cytoplasm to inner actin filaments complexes in both AGE-added and high glucose condition. In Western blotting, high glucose or AGE-added condition decreased the ZO-1 protein expression by 11.1%(P>0.05) and 2.3%(P>0.05), respectively compared to the normal glucose condition. High glucose plus AGE-added condition further decreased ZO-1 protein expression to statistically significant level(12%, P<0.05). No significant change was seen in the osmotic control. In RT-PCR, high glucose plus AGE-added condition significantly decreased the expression of ZO-1 mRNA by 12% compared to normal glucose condition. Conclusion: We suggest that both high glucose and AGE-added condition induce the cytoplasmic translocation and suppresses the production of ZO-1 at transcriptional level and these changes may explain the functional changes of podocytes in diabetic conditions.

  • PDF

A study for Beating Filter Press Dewatering Technology (열(熱) 필터프레스 기술(技術)을 통한 슬러지 탈수율(脫水率) 향상(向上)을 위한 연구(硏究))

  • Lee, Jung-Eun;Kim, Dong-Su
    • Resources Recycling
    • /
    • v.15 no.3 s.71
    • /
    • pp.38-45
    • /
    • 2006
  • The thermal filter press dewatering(TFPD) technology to improve the dewaterability through increasing the inner vapor pressure, lowering the filtration viscosity and forming the porosity easily within cake as applying the heat at the sludge layer was developed in this study. The hot water with temperature of $95^{\circ}C$ and pressure of $1.2kg_f/cm^2$ was supplied to the heating plate equipped between filter plates with plate size of $470{\times}470mm$ and material of polypropylene. Sludge was dewaterd by supplying pressure of $5kg_f/cm^2$ and then by squeezing pressure of $15kg_f/cm^2$. As a results of estimating the characteristics of thermal dewatering to consider the initial water content and organic content to be influenced by a period of water shortage and rainwater, the dewatered cake water content was about 35 wt% and dewatering velocity was $4DSkg/m^2{\cdot}hr$ under the rainwater period, and the dewatered cake water content was about 50 wt% and dewatering velocity was $1.5DSkg/m^2{\cdot}hr$ in the case of sludge of water shortage season. These results was superior to the mechanical dewatering performance with water content of 70wt% and dewatering velocity of $0.9DSkg/m^2{\cdot}hr$. On the base of the results of TFPD, energy consumpted to deal with DS(Dry Solid) of 1kg was estimated by 300 kJ. It was analyzed that the energy consumption of TFPD was decreased about one third with comparison to the dryer system. Dewatering velocity of this technology was faster than the one of mechanical dewatering equipment and it was easier to product low water content cake. Therefore, this technology was recognized that dewaterability was predominant because of the fast of dewatering velocity and production of low water content cake, and also this known as economical efficiency was excellent because of low energy consumption in comparison with dryer.

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Renal Effects of Intracerebroventricular Bromocriptine in the Rabbit (가토에 있어서 측뇌실내 Bromocriptine의 신장작용)

  • Kook, Young-Johng;Kim, Kyung-Keun;Kim, Jae-Pil;Kim, Kyung-Ho
    • The Korean Journal of Pharmacology
    • /
    • v.21 no.1
    • /
    • pp.49-61
    • /
    • 1985
  • In view of the facts that dopamine (DA) when given directly into a lateral ventricle (i.c.v.) of the rabbit brain induces antidiuresis and that haloperidol, a non-specific antagonist of DA receptors, produces anti-diuresis in smaller doses and diuresis and natriuresis in larger doses, the present study was undertaken to delineate the roles of various DA receptors involved in the center-mediated regulation of renal function. Bromocriptine (BRC), a relatively specific agonist of D-2 receptors and at the same time a D-,1 antagonist, elicited natriuresis and diuresis when given i.c.v. in doses ranging from 20 to 600 {\mu}g/kg$, roughly in dose-related fashion, while the renal perfusion and glomerular filtration progressively decreased with doses, indicating that the diuretic, natriuretic action resides in the tubules, not related to the hemodynamic effects. These diuresis and natriuresis were most marked with 200 ${\mu}g/kg$, with the fractional sodium excretion reaching about 10%. With 600 ${\mu}g/kg$, however, the diuretic, natriuretic action was preceded by a transient oliguria resulting from severe reduction of renal perfusion, concomitant with marked but transient hypertension. When given intravenously, however, BRC produced antidiuresis and antinatriuresis along with decreases in renal hemodynamics associated with systemic hypotension, thus indicating that the renal effects produced by i.c.v. BRC is not caused by a direct renal effects of the agent which might have reached the systemic circulation. In experiments in which DA was given i.c.v. prior to BRC, 150 ${\mu}g/kg$ DA did not affect the effects of BRC (200 ${\mu}g/kg$), while 500 ${\mu}g/kg$ DA abolished the BRC effect. In rabbits treated with reserpine, 1 mg/kg i.v.,24 h prior to the experiment, i.c.v. BRC could unfold its renal effects not only undiminished but rather exaggerated and more promptly. In preparations in which one kidney is deprived of nervous connection, the denervated kidney responded with marked diuresis and natriuresis, whereas the innervated, control kidney exhibited antidiuresis. These observations suggest that i.c.v. BRC influences the renal function through release of some humoral natriuretic factor as well as by increasing sympathetic tone, and that various DA receptors might be involved with differential roles in the center-mediated regulation of the renal function.

  • PDF

Influence of Intracerebroventricular Haloperidol on the Renal Function of the Rabbit (가토신장기능에 미치는 측뇌실내 Haloperidol의 영향)

  • Kim, Joong-Ky;Choi, Bong-Kyu;Kook, Young-Johng
    • The Korean Journal of Pharmacology
    • /
    • v.18 no.2
    • /
    • pp.103-117
    • /
    • 1982
  • In an effort to provide evidence as to the regulatory role of the central dopaminergic system on the renal function, the effects of centrally administered dopamine and its specific antagonist haloperidol were investigated. Haloperidol (HA) given intracerebroventricularly (i.c.v.) induced antidiuresis in doses of 15 and $50{\mu}g/kg$. With $15{\mu}g/kg$ sodium reabsorption in the tubules was increased, while with $50{\mu}g/kg$ free-water reabsorption was increased. However, a marked diuresis with increased sodium and potassium was observed with $150{\mu}g/kg$. Hemodynamic changes were not evident, indicating that the diuresis is of tubular origin. Dopamine (DA), on the other hand, produced antidiuresis when given i.c.v. in a dose-related fashion. With smaller doses of 5 and $15{\mu}g/kg$ the antidiuresis was related to increased reabsorption of sodium in the tubules, but higher doses of 50 and $150{\mu}g/kg$ the decreases in renal blood flow and glomerular filtration rate were evident in addition to the tubular action. After pretreatment with $150{\mu}g/kg$ HA, the effects of $15{\mu}g/kg$ DA was abolished, but the antidiuretic actions of 50 and $150{\mu}g/kg$ were not blocked, and the natriuretic diuretic action of HA was overcome and became inconspicuous. These observations indicate that the central dopaminergic system influences the renal function by producing antidiuresis, and HA elicits diuresis and natriuresis by competitively antagonizing DA specifically on the central dopaminegic receptors. The antidiuresis observed with smaller doses of HA can be best explained by the facts that there are more than two types of DA-receptors in the brain and that the presynaptic autoreceptors on the dopaminergic neurones which affect the dopamine release at the synapse are more sensitive than the postsynaptic receptors. Overall, these data provide an evidence indicating that the central dopaminergic system plays a role in the regulation of renal function in the rabbit.

  • PDF

Human Health Risk, Environmental and Economic Assessment Based on Multimedia Fugacity Model for Determination of Best Available Technology (BAT) for VOC Reduction in Industrial Complex (산업단지 VOC 저감 최적가용기법(BAT) 선정을 위한 다매체 거동모델 기반 인체위해성·환경성·경제성 평가)

  • Kim, Yelin;Rhee, Gahee;Heo, Sungku;Nam, Kijeon;Li, Qian;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.325-345
    • /
    • 2020
  • Determination of Best available technology (BAT) was suggested to reduce volatile organic compounds (VOCs) in a petrochemical industrial complex, by conducting human health risk, environmental, and economic assessment based on multimedia fugacity model. Fate and distribution of benzene, toluene, ethylbenzene, and xylene (BTEX) was predicted by the multimedia fugacity model, which represent VOCs emitted from the industrial complex in U-city. Media-integrated human health risk assessment and sensitivity analysis were conducted to predict the human health risk of BTEX and identify the critical variable which has adverse effects on human health. Besides, the environmental and economic assessment was conducted to determine the BAT for VOCs reduction. It is concluded that BTEX highly remained in soil media (60%, 61%, 64% and 63%), and xylene has remained as the highest proportion of BTEX in each environment media. From the candidates of BAT, the absorption was excluded due to its high human health risk. Moreover, it is identified that the half-life and exposure coefficient of each exposure route are highly correlated with human health risk by sensitivity analysis. In last, considering environmental and economic assessment, the regenerative thermal oxidation, the regenerative catalytic oxidation, the bio-filtration, the UV oxidation, and the activated carbon adsorption were determined as BAT for reducing VOCs in the petrochemical industrial complex. The suggested BAT determination methodology based on the media-integrated approach can contribute to the application of BAT into the workplace to efficiently manage the discharge facilities and operate an integrated environmental management system.

A Prediction Model for Removal of Non-point Source Pollutant Considering Clogging Effect of Sand Filter Layers for Rainwater Recycling (빗물 재활용을 위한 모래 정화층의 폐색특성을 고려한 비점오염원 제거 예측 모델 연구)

  • Ahn, Jaeyoon;Lee, Dongseop;Han, Shinin;Jung, Youngwook;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.6
    • /
    • pp.23-39
    • /
    • 2014
  • An artificial rainwater reservoir installed in urban areas for recycling rainwater is an eco-friendly facility for reducing storm water effluence. However, in order to recycle the rainwater directly, the artificial rainwater reservoir requires an auxiliary system that can remove non-point source pollutants included in the initial rainfall of urban area. Therefore, the conventional soil filtration technology is adopted to capture non-point source pollutants in an economical and efficient way in the purification system of artificial rainwater reservoirs. In order to satisfy such a demand, clogging characteristics of the sand filter layers with different grain-size distributions were studied with real non-point source pollutants. For this, a series of lab-scale chamber tests were conducted to make a prediction model for removal of non-point source pollutants, based on the clogging theory. The laboratory chamber experiments were carried out by permeating two types of artificially contaminated water through five different types of sand filter layers with different grain-size distributions. The two artificial contaminated waters were made by fine marine-clay particles and real non-point source pollutants collected from motorcar roads of Seoul, Korea. In the laboratory chamber experiments, the concentrations of the artificial contaminated water were measured in terms of TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) and compared with each other to evaluate the performance of sand filter layers. In addition, the accumulated weight of pollutant particles clogged in the sand filter layers was estimated. This paper suggests a prediction model for removal of non-point source pollutants with theoretical consideration of the physical characteristics such as the grain-size distribution and composition, and change in the hydraulic conductivity and porosity of sand filter layers. The lumped parameter ${\theta}$ related with the clogging property was estimated by comparing the accumulated weight of pollutant particles obtained from the laboratory chamber experiments and calculated from the prediction model based on the clogging theory. It is found that the lumped parameter ${\theta}$ has a significant influence on the amount of the pollutant particles clogged in the pores of sand filter layers. In conclusion, according to the clogging prediction model, a double-sand-filter layer consisting of two separate layers: the upper sand-filter layer with the effective particle size of 1.49 mm and the lower sand-filter layer with the effective particle size of 0.93 mm, is proposed as the optimum system for removing non-point source pollutants in the field-sized artificial rainwater reservoir.