• Title/Summary/Keyword: Filter efficiency

Search Result 1,506, Processing Time 0.034 seconds

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

A Study on the Collecting Efficiency of Oil-mist Filter according to the Sub-filter Shape (서브필터 형상에 따른 Oil-mist Filter의 포집효율 향상에 관한 연구)

  • Kim, Yong Sun;Yun, Seong Min;Shin, Hee Jae;Ko, Sang Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Cooking oil in kitchen-fog is the most harmful factor to the health of a cook. The proposed filter is a tool that protects the cooked state, to prevent users from inhaling oil mist in the kitchen. Due to efficiency issues, existing filters are of the mesh type or baffle type. In this paper, CFD analysis is carried out to select a filter with low pressure loss and low efficiency, and to attach the sub-filter to improve efficiency. The results of the analysis on the collection efficiency and pressure loss of three sub-filters, i.e., circle type, droplet type, and cone type, showed that the collection efficiency was 64.09% and the pressure loss was 1.26 mmAq when the circle type sub-filter was applied. The position of the sub-filter showed the best efficiency and pressure loss when it was located at the bottom of the center of the gap of the main filter.

An Experimental Study on Enhancement of the Filter Efficiency by the Image Effect of Charged Particle (대전된 입자의 영상효과에 의한 필터효율 향상에 관한 실험적 연구)

  • Lee, Chang-Sun;Jeong, Hae-Young;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.760-768
    • /
    • 2000
  • Filter efficiency of electrically charged particle in uncharged fibrous filter was measured. In previous studies, the effect of charged particle on filter efficiency was investigated but there was difficulty in measuring of image effect that is appeared at the charged small particle. We could easily measure the image effect with charging small particles by photoelectric charging. The spark discharge aerosol generator and a differential mobility analyzer (DMA) were used to generate sub-micron monodisperse particles (${\leq}200$ nm). The generated particles were charged in photoelectric charging process using ultraviolet lamp and electric field. The filter efficiency of the charged particles, classified by another DMA, was measured in filter tester using a condensation nucleus counter (CNC) as function of particle diameter, particle charge and airflow velocity. It is shown that the filter efficiency increases with increasing charge number of the particle and is affected by particle size and flow velocity. Single fiber filter efficiency mainly depends on image force parameter and peclet number. The peclet number was not considered at previous other papers. We propose a modi fied experimental correlation as function of image force parameter and peclet number.

Charge Depletion Effect on Collection Efficiency of an Electret Cabin Air Filter for Submicron Particles (승용차용 정전 필터 내의 정전 섬유의 보유 하전 감쇄에 의한 미세 입자 포집효율 변화)

  • Ji, Jun-Ho;Kang, Suk-Hoon;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.71-76
    • /
    • 2001
  • An electret filter is composed of permanently charged electet fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles are loaded. Long-term experiments were conducted by applying different charging states, which are spray electrification and charge equilibrium by bipolar ionization. In order to investigate on the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. In NaCl 0.1%, the collection efficiency of electret filter decreased and then did not change in equilibrium state. In the case of relative larger particles of NaCl 1%, collection efficiency for the equilibrium charged particles increases due to the particle loading on the filter fibers. Particles charged by spray electrification are small in collection efficiency after equilibrium state and increase of filter media's pressure drop was very low in comparison of the equilibrium charged particles.

  • PDF

Effect of Particle Loading on the Collection Performance of an Electret Cabin Air Filter for Submicron Particles (입자 퇴적이 승용차용 정전 필터의 미세 입자 포집 특성에 미치는 영향)

  • Ji, Jun-Ho;Gang, Seok-Hun;Hwang, Jeong-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1102-1114
    • /
    • 2002
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles were loaded. Long-term experiments were conducted by applying two different charging states, which were spray electrification and charge equilibrium by bipolar ionization. In order to investigate the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. Liquid DOS particles were used to evaluate the effect of liquid particles on the collection efficiency of an electret filter. The results show significant effect of charge amount and size distribution of loading particles on the collection performance of a filter media in submicron region. Smaller particles loaded in electret fibers cause a more rapid degradation in collection efficiency and have lower minimum efficiency with time. The pressure drop of a filter media do rarely increase when the collection efficiency decreases to the minimum value. For the larger particles charged by spray electrification, which have charge amounts more than that of Boltzmann equilibrium charge distribution, the pressure drop of a filter media slowly increases in comparison with that of equilibrium charged particles. For DOS particles it is shown that the charging level of an electret filter severely decreases and the collection efficiency is below 10% in some particle size range.

An investigation into the performance of a high-speed synthetic fiber filter employing different types of coagulants (응집제에 따른 합성섬유 여재를 충진한 고속필터의 여과특성에 관한 연구)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.125-139
    • /
    • 2017
  • In this paper, the performance of a synthetic fiber filter aimed at high-speed operation and dosed with different coagulants or filter aids was investigated. Without a coagulant, the filter efficiency was about 62% which was greatly enhanced when three types of coagulants namely PAC, Alum, and $FeCl_3$ were used. Among the coagulants tested, PAC was the most effective, giving 91% filter efficiency, followed by Alum with 90%, and $FeCl_3$ with 78%. PAC worked effectively at a very small range of dose, but Alum was relatively effective in a wide range of concentration. Compared with PAC and Alum, $FeCl_3$ provided more or less contant efficiency regardless of its dose but gave the poorest filter efficiency. Moreover, as the inflow turbidity increased, headloss increased and the efficiency decreased at any dose and type of coagulant. The headloss recorded in this particular synthetic fiber filter is not significant as compared to that observed in typical granular filters. The recovery of solids estimated after filter cleaning was about 80% for both PAC and Alum, but poorer at 72% in the case of $FeCl_3$ due to the heavy and large floc characteristics. The recurrence of filter efficiency verified through repetitive filter runs was found to be satisfactory.

Numerical Analysis of Fluid Flow and Filtering Efficiency in Centrifugal Oil Filter (원심 오일필터 유동 해석을 통한 필터링 효율 분석)

  • Bang, Kwang-Hyun;Kim, Kyung-Kyu;Song, Young-A;Kim, Pyung-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.867-872
    • /
    • 2009
  • In centrifugal oil filters particles are forced to move toward the filter casing wall by centrifugal force in the rotating oil flow and the particles are trapped and removed on the filter paper installed at the wall. In the present study, flow field of oil and particle motion in a centrifugal oil filter has been numerically calculated in order to estimate the filtering efficiency for various operating conditions. Fluent code was used for the numerical calculations. Uncoupling the oil flow and the particle motion and the use of particle tracking trajectory enabled the estimation of filtering efficiency for various particle sizes, particle density and the filter rotational speed. Higher filtering efficiency was observed for heavier and larger particles as well as higher filter rotational speed. For the typical case of the particle density of $6000kg/m^3$ and the particle size of $10{\mu}m$ at 3500 RPM, the calculated filtering efficiency per passage was 0.31.

Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations (지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구)

  • Ahn, Y.C.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries (산업용 필터백의 구조에 따른 여과성능 특성)

  • Jeon, Seong-Min;Hasolli, Naim;Lee, Kang-San;Lee, Jea-Rang;Kim, Kwang-Deuk;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.4
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

Characteristics of Electrostatic Cyclone-Bag Filter with Upper Inlet (상부유입식 전기 Cyclone-Bag Filter의 특성)

  • 여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.179-190
    • /
    • 2000
  • The main object of this study was to investigate experimentally the characteristics of electrostatic cyclone-bag filter with upper tangential inlet in order to overcome the low collection efficiency for the submicron particle and high pressure drop which were main problems of general fabric bag filters. The experiment was carried out for the analysis of collection efficiency and pressure drop of electrostatic cyclone-bag filter comparing to those of fabric bag filter with various experimental parameters such as the inlet velocity(filtration velocity) and applied voltage etc. In the results the upper tangential inlet type showed higher collection efficiency for submicron particles below 2 ${\mu}{\textrm}{m}$ in diameter than that of center inlet and over 99.9% for overall collection efficiency. Pressure drop reduction ratios were shown as 40-50% for the applied voltage 0kV by centrifugal force and 70-90% for 20k V by the centrifuga and electrostatic force with the tangential inlet velocity (12-21m/s)

  • PDF