A Case of Phlegmasia Cerulea Dolens as a Complication Caused by Placement of Inferior Vena Cava Filter (하대정맥 필터 삽입 후 합병증으로 발생한 Phlegmasia Cerulea Dolens 1예)

  • Cho, Young Sin;Kim, Jong Hwa;Lee, Ho Sung;Choi, Jae Sung;Na, Ju Ock;Seo, Ki Hyun;Kim, Yong Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.3
    • /
    • pp.225-229
    • /
    • 2008
  • Inferior vena cava filters are increasingly being used as an alternative to anticoagulation therapy for the prevention of pulmonary embolism. However, using an Inferior vena cava filter may result in clinically significant complications. Phlegmasia cerulea dolens is a rare disease that presents with acute complete venous occlusion due to extensive thrombosis in the lower extremity. It is characterized by intense pain, edema, decreased pulses and a cyanotic extremity. We report here on a case of phlegmasia cerulea dolens that was accompanied with disseminated intravascular coagulation (DIC) as a complication of the placement of an inferior vena cava filter in a patient who had been previously diagnosed with pulmonary embolism, and the patient had recently developed a cerebral hemorrhage due to a traffic accident.

Duodenal Perforation Caused by an Inferior Vena Cava Filter

  • Bae, Mi-Ju;Chung, Sung-Woon;Lee, Chung-Won;Kim, Sang-Pil;Song, Seung-Hwan
    • Journal of Chest Surgery
    • /
    • v.45 no.1
    • /
    • pp.69-71
    • /
    • 2012
  • The inferior vena cava (IVC) filter is known as an effective and safe method for preventing fatal pulmonary thromboembolism in patients with deep vein thrombosis. Usually, the remaining IVC filters are asymptomatic and do not cause clinical problems. We report a case of duodenal perforation caused by a remaining IVC filter.

Should We Remove the Retrievable Cook Celect Inferior Vena Cava Filter? Eight Years of Experience at a Single Center

  • Son, Joohyung;Bae, Miju;Chung, Sung Woon;Lee, Chung Won;Huh, Up;Song, Seunghwan
    • Journal of Chest Surgery
    • /
    • v.50 no.6
    • /
    • pp.443-447
    • /
    • 2017
  • Background: The inferior vena cava filter (IVCF) is very effective for preventing pulmonary embolism in patients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. Methods: A retrospective study was performed of 159 patients who underwent retrievable Cook Celect IVCF implantation between January 2007 and April 2015 at a single center. Baseline characteristics, indications, and complications caused by the filter were investigated. Results: The most common underlying disease of patients receiving the filter was cancer (24.3%). Venous thrombolysis or thrombectomy was the most common indication for IVCF insertion in this study (47.2%). The most common complication was inferior vena cava penetration, the risk of which increased the longer the filter remained in the body (p=0.032, Exp(B)=1.004). Conclusion: If the patient is able to retry anticoagulation therapy and the filter is no longer needed, the filter should be removed, even if a long time has elapsed since implantation. If the filter cannot be removed, it is recommended that follow-up computed tomography be performed regularly to monitor the progress of venous thromboembolisms as well as any filter-related complications.

A New Fault Diagnosis Scheme between L1 Signals Using IES on the Metric Defined via Kalman Filter and Exponential Function Transformation (칼만추정과 초월함수 사영을 통한 L1 신호간의 거리 Metric에 IES을 적용한 새로운 고장진단 기법)

  • Kim, Sung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.23-28
    • /
    • 2015
  • Measuring the distances between signals in the signal space is usually determined by obtaining the ideal metric which is not easy to obtain. In this research we have investigated the scheme that measures the distances between the signals constructed with the measured voltage signals connected to electric apparatus using Kalman filter and exponential mapping. The metric is defined on the feature signals obtained via the estimation process of a Kalman filter and the mapping process using the exponential transformation. Diagnosis is on the voltage fluctuations is applied to determining whether the system is in the stable state or not due to the unexpected accidents, such as power overcharge, discharge, outages flow may be the cause of the accident. The decision making scheme evaluated with respect to the effectiveness and the degree of complication with different variances. Two methods, the Hard Limit Threshold Scheme(HLTS) and the Interval Energy Scheme(IES) are proposed and compared. In experiments the IES shows better tolerance to impulse noise than the HLTS.

The Occurence of Deep Vein Thrombosis in Abdominal Compartment Patient (복부구획증후군 환자에서 발생한 심부정맥혈전증)

  • Kim, Seong Yup;Jin, Sung Chan
    • Journal of Trauma and Injury
    • /
    • v.26 no.4
    • /
    • pp.312-315
    • /
    • 2013
  • Abdominal compartment syndrome is one cause of deep vein thrombosis of lower extremity. Although prophylactic dose of anticoagulation agent is safely started after 24~48 hours without the evidence of active bleeding, there may be bleeding complication related to invasive procedure which trauma victims undergo. Inferior vena cava filter should be considered in the treatment plan of this complex situation.

The Clinical Effects of Leukocyte-Depleting Filter on Cardiopulmonary Bypass (체외순환 시 백혈구 제거필터 사용의 임상효과)

  • 박경택;최석철;최국렬;정석목;최강주
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.454-464
    • /
    • 2001
  • Background: It has been recognized that systemic inflammatory reaction and oxygen free radical formed by activated leukocyte in the procedure of cardiopulmonary bypass(CPB) frequently produce postoperative cardiac and pulmonary dysfunction. The purpose of this study was to evaluate the efficacy of leukocyte-depleting filters in the cardiopulmonary bypass circuit for patients undergoing open heart surgery(OHS). Material and method: The study involved 15 patients who underwent OHS with a Leukoguard-6 leukocyte filter placed in the arterial limbs of the bypass circuit(filter group, n=15) and 15 patients who did not have the filter(control group, n=15). We analyzed the differences between the groups in intraoperative changes of peripheral blood leukocyte and platelet counts, pre- and postbypass changes of malondialdehyde(MDA), troponin-T(TnT), 5'-nucleotidase(5'-NT) in coronary sinus blood, spontaneous recovery rate of heart beat after CPB, pre-and postoperative cardiac index(Cl) and pulmonary vascular resistance(PVR), and the amounts of postoperative bleeding and sternal wound complication. Result: During CPB, total leukocyte count of the filter group(9,567$\pm$ 842/㎣) was significantly less than that of the control group(13,573+1,167/㎣) (p<0.01), but there was no significant difference in platelet count between the groups. Postoperative levels of MDA(3.78+0.32 $\mu$mol/L vs 5.86+0.65 $\mu$mo1/L, p<0.01), TnT(0.40$\pm$0.04 ng/mL vs 0.59$\pm$0.08 ng/mL, p<0.05) and 5'-NT(3.88$\pm$0.61 U/L vs 5.80$\pm$0.90 U/L, p<0.05) were all significantly lower in the filter group than the control group. Postoperative Cl was higher in the filter group than the control group(3.26$\pm$0.18 L/$m^2$min vs 2.75$\pm$0.17 L/$m^2$/min, p=0.05). PVR of the filter group was lower than that of the control group(65.87$\pm$7.59 dyne/sec/cm$^{5}$ vs 110.80+12.22 dyne/sec/cm$^{5}$ , p<0.01). Spontaneous recovery rate of heart beat in the filter group was higher than that in the control group(12 patients vs 8 patients, p<0.05). Postoperative wound infection occurred in one case in the filter group and 4 case in the control group(p<0.05). Postoperative 24 hour blood loss of the filter group was more than that of the control group (614$\pm$107 mL vs 380+71 mL, p=0.05).

  • PDF

Deep vein thrombosis caused by malignant afferent loop obstruction

  • Kang, Eun Gyu;Kim, Chan;Lee, Jeungeun;Cha, Min-uk;Kim, Joo Hoon;Park, Seo-Hwa;Kim, Man Deuk;Lee, Do Yun;Rha, Sun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.166-169
    • /
    • 2016
  • Afferent loop obstruction following gastrectomy is a rare but fatal complication. Clinical features of afferent loop obstruction are mainly gastrointestinal symptoms. A 56-year-old female underwent radical total gastrectomy with Roux-en-Y esophagojejunostomy for treatment of advanced gastric cancer. After fourteen months postoperatively, she showed gradual development of edema of both legs. Computed tomography (CT) scan showed disease progression at the jejunojejunostomy site and consequent dilated afferent loop, which resulted in inferior vena cava (IVC) compression. A drainage catheter was placed percutaneously into the afferent loop through the intrahepatic duct and an IVC filter was placed at the suprarenal IVC, and self-expanding metal stents were inserted into bilateral common iliac veins. With these procedures, sympotms related with afferent loop obstruction and deep vein thrombosis were improved dramatically. The follow-up abdominal CT scan was taken 3 weeks later and revealed the completely decompressed afferent loop and improved IVC patency. Surgical treatment should be considered as the first choice for afferent loop obstruction; however, because it is more immediate and less invasive, non-surgical modalities, such as percutaneous catheter drainage or stent placement, can be effective alternatives for inoperable cases or risky patients who have severe medical comorbidities.

Result of Radiation Therapy of Sino-nasal Cancers Using Partial Attenuation Filter (투과성 필터를 이용하여 방사선 치료를 받은 부비동 및 비암의 치료 결과)

  • Kim, Jin-Hee;Kim, Ok-Bae;Choi, Tae-Jin
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.118-124
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study was to evaluate the survival and pattern of failure after radiation therapy of sino-nasal cancer using partial attenuation filer and wedged beams and to help radiotherapy planning of sino-nasal cancer. $\underline{Materials\;and\;Methods}$: Between February 1992 and March 2003, 17 patients with sino-nasal cancers underwent radiation therapy using partial attenuation filter at Dongsan Medical Center, Keimyung university. There were 9 male and 8 female patients. Patients' age ranged from 40 to 75 years (median 59 years). There were 10 patients of maxillary sinus cancer, 7 patiens of nasal cancer. The histologic type was squamous cell carcinoma in 11, adenoid cystic carcinoma in 4 and olfactory neuroblastoma in 2. The distribution of clinical stage by the AJCC system was 3 for stage II, 7 for III and 6 for IV. The five patients were treated with radiation alone and 12 patients were treated with surgery and postoperative radiation therapy. The range of total radiation dose delivered to the primary tumor was from 44 to 76 Gy (median 60 Gy). The follow-up period ranged from 3 to 173 months with median of 78 months. $\underline{Results}$: The overall 2 year survival rate and disease free survival rate was 76.4%. The 5 year and 10 year survival rate were 76.4% and 45.6% and the 5 year and 10 year disease free survival rate was 70.6%. The 5 year disease free survival rate by treatment modality was 91.6% for postoperative radiation group and 20% for radiation alone group, statistical significance was found by treatment modality (p=0.006). There were no differences in survival by pathology and stage. There were local failure in 5 patients (29%) but no distant failure and no severe complication required surgical intervention. $\underline{Conclusion}$: Radiation therapy of sino-nasal cancer using partial attenuation filter was safe and effective. Combined modality with conservative surgery and radiation therapy was more advisable to achieve loco-regional control in sino-nasal cancer. Also we considered high precision radiation therapy with dose escalation and development of multi-modality treatment to improve local control and survival rate in advanced sino-nasal cancer.

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

Pulmonary Thromboendarterectomy for Pulmonary Hypertension Caused by Chronic Pulmonary Thromboembolism (만성폐색전중으로 인한 폐동맥고혈압 환자에서 시행한 폐동맥내막절제술)

  • Song Seung-Hwan;Jun Tae-Gook;Lee Young-Tak;Sung Ki-Ick;Yang Ji-Hyuk;Choi Jin-Ho;Kim Jin-Sun;Kim Ho-Joong;Park Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.626-632
    • /
    • 2006
  • Background: Pulmonary hypertension caused by chronic pulmonary embolism is underrecognized and carries a poor prognosis. Medical therapy is generally unsatisfactory and palliative. With the improvement of operative technique and postoperative management, pulmonary endarterectomy has been the treatment of choice for this condition. Material and Method: Between January 2001 and December 2005, eleven patients were received pulmonary endarterectomy. All patients had chronic dyspnea and exercise intolerance. Diagnosis was made with cardiac echocardiography, lung perfusion scan and computed tomography. Before the operation, Greenfield vena cava filter were placed in all patient except one. Deep hypothermic circulatory arrest was used for the distal-most portion of the endarterectomy procedure. More than moderate degree of tricuspid reguirgitation was repaired during operation. Result: There was no early and late death. Right ventricular systolic pressure was reduced significantly after operation from $91{\pm}21$ mmHg to $40{\pm}17$ mmHg on echocardiography (p=0.001). NYHA class and tricuspid reguirgitaion were improved postoperatively. Although mild reperfusion injury in three case and postoperative delirium in one case were observed, all of them recovered without complication. Conclusion: Pulmonary thromboendarterctomy offers to patient an acceptable morbidity rate and anticipation of clinical improvement. This method is safe and effective operation for pulmonary hypertension caused by chronic pulmonary thromboembolism.