• 제목/요약/키워드: Filter Quality

검색결과 1,542건 처리시간 0.028초

순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터 (3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation)

  • 한석우;최규하
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.544-551
    • /
    • 2000
  • In this paper, 3-phase hybrid series active power filter for compensate current harmonics, voltage drop and unbalanced voltage in the network presented. The proposed system is implemented with a space vector modulation voltage source inverter and a high pass filter connected in parallel to the power system. Here the load is six-pulses thyristor rectifier. The phase angle detected in order to generation reference voltage at load terminal is synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The proposed system has an function harmonic isolation between source and load, voltage regulation, and unbalance compensation. Therefore, what the power system is improved quality, the source current is maintained as a nearly sinusoidal waveform and the load voltage is regulated with a rated voltage regardless of the source variation condition. To verify the validity of the proposed compensating system, the computer simulation and experiment are carried out.

  • PDF

직렬형과 병렬형 능동필터를 조합한 통합형 전력품질 개선장치에 관한 연구 (The Study on Unified Power Quality Conditioner(UPQC) Aiming at the Integration of Series-active and Shunt-Active Filter)

  • 이현옥;노대석;오성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.305-307
    • /
    • 2001
  • This paper deals with single-phase unified power quality conditioner(UPQC), which aims at the integration of series-active and shunt-active filter. The series filter is used to compensate for the voltage distortions and the shunt filter is used to provide reactive power and counteract the harmonic current injected by the load. Also, the voltage of the DC link capacitor is controlled to a desired value by the shunt active filter. The performance of UPQC under load nonlinearities conditions is investigated using simulation as well as experimental results.

  • PDF

Feasibility study of improved median filtering in PET/MR fusion images with parallel imaging using generalized autocalibrating partially parallel acquisition

  • Chanrok Park;Jae-Young Kim;Chang-Hyeon An;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.222-228
    • /
    • 2023
  • This study aimed to analyze the applicability of the improved median filter in positron emission tomography (PET)/magnetic resonance (MR) fusion images based on parallel imaging using generalized autocalibrating partially parallel acquisition (GRAPPA). In this study, a PET/MR fusion imaging system based on a 3.0T magnetic field and 18F radioisotope were used. An improved median filter that can set a mask of the median value more efficiently than before was modeled and applied to the acquired image. As quantitative evaluation parameters of the noise level, the contrast to noise ratio (CNR) and coefficient of variation (COV) were calculated. Additionally, no-reference-based evaluation parameters were used to analyze the overall image quality. We confirmed that the CNR and COV values of the PET/MR fusion images to which the improved median filter was applied improved by approximately 3.32 and 2.19 times on average, respectively, compared to the noisy image. In addition, the no-reference-based evaluation results showed a similar trend for the noise-level results. In conclusion, we demonstrated that it can be supplemented by using an improved median filter, which suggests the problem of image quality degradation of PET/MR fusion images that shortens scan time using GRAPPA.

자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출 (Identification of operating parameters in auto-discharging filter system for treatment of urban storm water)

  • 김선희;권은미;박성순;조성주;임채환;강선홍
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.377-386
    • /
    • 2010
  • To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.

Power Quality Impacts of an Electric Arc Furnace and Its Compensation

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.153-160
    • /
    • 2006
  • This paper presents a new compensating system, which consists of a shunt active filter and passive components for mitigating voltage and current disturbances arising from an Electric Arc Furnace (EAF). A novel control strategy is presented for the shunt active filter. An extended method based on instantaneous power theory in a rotating reference frame is developed for extraction of compensating signals. Since voltages at the point of common coupling contain low frequency interharmonics, conventional methods cannot be used for dc voltage regulation. Therefore, a new method is introduced for this purpose. The passive components limit the fast variations of load currents and mitigate voltage notching at the Point of Common Coupling (PCC). A three-phase electric arc furnace model is used to show power quality improvement through reactive power and harmonic compensation by a shunt active filter using the proposed control method. The system performance is investigated by simulation, which shows improvement in power quality indices such as flicker severity index.

Fast Bilateral Filtering Using Recursive Gaussian Filter for Tone Mapping Algorithm

  • 프리마스투티 대위;남진우;차의영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.176-179
    • /
    • 2010
  • In this paper, we propose a fast implementation of Bilateral filter for tone mapping algorithm. Bilateral filter is able to preserve detail while at the same time prevent halo-ing artifacts because of improper scale selection by ensuring image smoothed that not only depend on pixel closeness, but also similarity. We accelerate Bilateral filter by using a piecewise linear approximation and recursive Gaussian filter as its domain filter. Recursive Gaussian filter is scale independent filter that combines low cost 1D filter which makes this filter much faster than conventional convolution filter and filtering in frequency domain. The experiment results show that proposed method is simpler and faster than previous method without mortgaging the quality.

  • PDF

Power Quality Improvement Using Hybrid Passive Filter Configuration for Wind Energy Systems

  • Kececioglu, O. Fatih;Acikgoz, Hakan;Yildiz, Ceyhun;Gani, Ahmet;Sekkeli, Mustafa
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.207-216
    • /
    • 2017
  • Wind energy conversion systems (WECS) which consist of wind turbines with permanent magnet synchronous generator (PMSG) and full-power converters have become widespread in the field of renewable power systems. Generally, conventional diode bridge rectifiers have used to obtain a constant DC bus voltage from output of PMSG based wind generator. In recent years, together advanced power electronics technology, Pulse Width Modulation (PWM) rectifiers have used in WECS. PWM rectifiers are used in many applications thanks to their characteristics such as high power factor and low harmonic distortion. In general, L, LC and LCL-type filter configurations are used in these rectifiers. These filter configurations are not exactly compensate current and voltage harmonics. This study proposes a hybrid passive filter configuration for PWM rectifiers instead of existing filters. The performance of hybrid passive filter was tested via MATLAB/Simulink environment under various operational conditions and was compared with LCL filter structure. In addition, neuro-fuzzy controller (NFC) was preferred to increase the performance of PWM rectifier in DC bus voltage control against disturbances because of its robust and nonlinear structure. The study demonstrates that the hybrid passive filter configuration proposed in this study successfully compensates current and voltage harmonics, and improves total harmonic distortion and true power factor.

낙동강 하류원수에 적합한 여과지의 여재구성 (The adaptive filter configuration for down stream of Naktong river)

  • 김상구;류동춘;이영식;손진언
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.95-95
    • /
    • 1995
  • This study was carried out to evaluate the variations of headloss rate and of specific deposit to depths with effective size of media and configuration of filter layer during algae blooming period. 0.51mm size media was disqualified because most of headloss occurred rapidly below 5cm from surface layer however 0.91mm size media acted deep filtration more than 20cm from top, as result 0.91mm sixte media filter had 2∼3 times longer filtration time than 0.51mm sixte media filter, but 0.91mm size media have break-through potentiality. multi-layer filter with 1.02mm anthracite and 0.51mm sand had large deposit volume in upper layer that could longer filtration time, moreover smaller media in lower layer that could protect break-through.

급속여과공정에서의 여과보조제 사용에 따른 여과특성 (Characteristics of High-Rate Filtration with Filtration Aids)

  • 안종호;윤재흥
    • 상하수도학회지
    • /
    • 제14권3호
    • /
    • pp.260-270
    • /
    • 2000
  • The objective of this study is to evaluate the effect of filter aids in the dual-media rapid filtration. Paper-filter tests were conducted to determine the proper dosages of coagulant and filter aid, and pilot plant tests using two dual-media filter columns were performed for a variety of filtration rates. Using a filter aid (non-ionic polymer), the maximum feasible filtration rate is 480m/day, while turbidity is less than 0.3 NTU and filter run-time is about 70 hours. It is possible to increase the filtration rate up to 360 m/day for keeping the turbidity less than 0.1 NTU. Turbidity increases for the filtration rate greater than 360m/day. In general, the quality of filtered water with a filter aid is stable, while the filter maintains a sufficient filter run-time for a maximum allowable head loss. Particularly, the initial breakthrough can be effectively controlled. The use of a filter aid may be one of the methods applicable if the turbidity of filtered water is required to be improved or if the filter breakthrough limits filter run-time.

  • PDF