• 제목/요약/키워드: Filter Media Test

검색결과 84건 처리시간 0.029초

Development of a Rapid PCR Test for Identification of Streptococcus agalactiae in Milk Samples Collected on Filter Paper Disks

  • Wu, Jiusheng;Liu, Yuehuan;Hu, Songhua;Zhou, Jiyong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제21권1호
    • /
    • pp.124-130
    • /
    • 2008
  • Streptococcus (Strep.) agalactiae is one of the major pathogens of bovine mastitis and is the main cause of subclinical infection. This study attempted to develop a rapid PCR diagnosis procedure using milk samples collected on filter paper disks. Chromatographic filter paper was employed as the preservation media and kept at room temperature for one to four weeks. The revival rate of Strep. agalactiae kept on dried filter paper disks was affected by the pretreatment preservation time. The revival test suggested that not all the bacteria in artificially contaminated milk samples on the filter paper disks could be recovered. After that, a PCR based on the 16-23S intergenic spacer region of Strep agalactiae was performed. The results distinguished the strep. agalactiae from major pathogens of bovine mastitis at a $2{\times}10^2$ colony forming units (CFU)/ml level, which showed similar sensitivity to the results from liquid milk samples. The results also showed that milk samples collected on filter paper disks could be kept at room temperature for one to four weeks with little negative effect on sensitivity and specificity. The field test showed that the diagnostic sensitivity and specificity was 96.15% and 98.60%, respectively. In conclusion, the protocol will provide a rapid and economic procedure for the detection of bovine mastitis.

고효율 항균 필터의 항균력 평가에 관한 연구 (A Study on Antibacterial Assesment of High Efficiency Antibacterial Air Filter)

  • 권혁구;정진도;류해열;정우성;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.549-554
    • /
    • 2002
  • Recently, interest in hygiene has been arouse in the health care field. Consequently, Filters with antibacterial agent applied to improve air quality by sterilizing bacteria, fungi, etc. We actually installed antibacterial air filter containing 2.5wt%Ag zeolite on the air intake route to air-conditioner in passenger cu, and evaluated filter's performance on antibacterial effect. By the microbe liquid spattering method, we found that the antibacterial air filter has notably sufficient antibacterial efficiency against standard strains and wild type strains. Antibacterial effect was observed at whole area of filter media by zone of inhibition test. The evaluation of microbe quantity was conducted through mixing dilution plate culture method. In comparison with ordinary filter, the amount of germs attached on antibacterial air filters was larger. The amount of germs attached on ordinary filters was very small since ordinary filters contained less dust. In comparison in antibacterial air filter with thickness, the amount of germs attached on 9mm filter was smaller than that of on 6mm filter. i.e. thicker filter, superior efficiency.

  • PDF

고효율 호흡보호구의 나노물질 입경별 제거 효율 (Fractional efficiency of Nanomaterials for the High efficiency respiratory filters)

  • 이광재;지준호;김원근;육세진;김종규;김정호
    • 한국입자에어로졸학회지
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 2016
  • 본 연구에서는 호흡용 보호구 필터의 나노물질에 대한 여과특성을 측정하기 위해서 소금(NaCl)과 은나노입자(Ag)를 대상으로 입경별 집진효율을 평가하였다. 호흡용 보호구 필터는 특급 방진마스크와 1급 방진마스크의 두 가지 안면부 여과식 방진마스크인 사용하였고, 마스크의 배기밸브 부분을 제외한 필터 여재 부분을 직경 47 mm로 잘라내어 필터홀더에 부착하여 입경별 입자제거효율을 시험하였다. 시험입자는 일반적으로 시험 입자로 사용되는 소금입자는 분무형 입자발생장치를 사용하여 발생하였고 중화기를 통과시켜 입자의 하전특성을 볼츠만 분포로 만들어 공급하였다. 은나노입자의 경우, 기화-응축 방법을 이용한 금속나노입자 생성방법인 ISO10801 방법을 사용하였다. 작업장의 은나노입자의 고농도 노출을 모사하기 위해, 중화기를 통과하지 않은 나노입자를 시험입자로 사용하였다. 은나노입자의 경우 소금입자로 만들기 어려운 20nm 이하의 입자를 안정적으로 효과적으로 만들어 시험에 적용하였고, 나노 크기에서도 매우 안정적인 데이터를 확보할 수 있었다. 1급 마스크 필터와 특급 마스크 필터에 대한 소금입자의 평가에서, 입경별 최소효율이 30~50nm 사이에서 나타나는 특성은 기존 연구와 비슷한 결과를 얻었다. 반면, 은나노입자의 경우 1급 마스크 필터와 특급 마스크 필터 모두에서 비슷한 크기의 소금 입자와 비교할 때 높은 효율을 나타냈다. 이것은 소금 입자의 경우 중화기를 통과시켜 시험입자로 사 용한 반면, 은나노입자의 경우 중화기를 통과시키지 않았기 때문이다. 본 연구에서는 작업장에서 은나노 입자가 고농도로 노출될 경우를 모사하여, 기화-응축에 의한 방법의 은나노입자 발생장치를 사용하였는데, 이 때 상대적으로 높게 대전된 입자들이 많이 만들어진다(Jung et al., 2006). 이로 인해, 정전필터인 마스크 필터의 포집 효과가 상대적으로 크기 때문에, 입경별 효율이 높아진 것으로 생각된다. 본 연구에서 평가한 1급 및 특급 방진마스크 여재의 최소 포집효율은 유럽 EN 149 기준인 95 LPM 유량 기준을 만족하는 것으로 나타났지만, 이것은 여재에 대한 평가 결과로, 실제 마스크에 대해서는 여재의 구조적인 불균일성이나 마스크를 착용하는 과정에서 밀착이 되지 않아 누출될 가능성은 마스크 사용에 고려되어야 한다. 불시에 발생할 수 있는 작업장 내 안전사고의 예방을 위하여 적절한 보호구의 선택과 올바른 착용 및 유지관리가 필요할 것으로 생각된다.

중.저준위 방사성폐기물 유리화설비에서 금속필터 적용성평가 (Performance Evaluation of Sintered Metal Filter in LILW Vitrification Facility)

  • 박승철;김병렬;황태원
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.146-153
    • /
    • 2006
  • 중 저준위 방사성폐기물 유리화 공정에서 발생되는 분진을 제거하기 위하여 저온용융로 후단에 금속필터를 장착하여 성능시험 및 필터 적용 평가를 실시하였다. 실험결과 기존의 고온세라믹필터와 유사한 차압특성을 보였으며, 유량 $110Nm^{3}/hr$ 기준으로, 필터 자체에 의한 압력손실은 $25mmH_{2}O$, 분진 잔류층에 의한 압력손실은 $67mmH_{2}O$ 정도였다. 따라서 기저차압은 $92mmH_{2}O$ 정도임을 확인할 수 있었다. 또한 SEM-EDS 분석결과 대부분의 차압은 멤브레인층의 표면에서 발생된 것으로 판단되며, 열화현상에 의한 부식문제등도 발견되지 않았다. 따라서 금속필터의 경우 유리화설비에 적용 가능한지를 분석하고, 장기시험을 통한 충분한 검증이 필요할 것으로 판단된다.

알카리 전처리에 의한 NBKP의 형태학적 및 이화학적 변화 (Morphological and Physicochemical Changes of NBKP by Alkali Pretreatment)

  • 문성필;장민환
    • 펄프종이기술
    • /
    • 제41권4호
    • /
    • pp.58-64
    • /
    • 2009
  • This study was carried out to prepare high porosity pulp for oil and air filter media from commercial grade NBKP with 6 - 20% NaOH treatment. The fiber width of NBKP remarkably decreased by NaOH pretreatment. The air permeability of the test sheet prepared from alkali-pretreated NBKP increased with increasing NaOH concentration up to 15%. The burst factor was greatly decreased by alkali pretreatment. By 15 - 20% NaOH pretreatment of NBKP, it could be possible to prepare a high porosity pulp. It seems that the high porosity of the pulp was due to a strong swelling and a great change of the cellulose crystalline lattice from cellulose I to cellulose II with NaOH treatment of NBKP. The study suggested that alkali- pretreated NBKP could be used for manufacturing oil and air filter media.

A DNN-Based Personalized HRTF Estimation Method for 3D Immersive Audio

  • Son, Ji Su;Choi, Seung Ho
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권1호
    • /
    • pp.161-167
    • /
    • 2021
  • This paper proposes a new personalized HRTF estimation method which is based on a deep neural network (DNN) model and improved elevation reproduction using a notch filter. In the previous study, a DNN model was proposed that estimates the magnitude of HRTF by using anthropometric measurements [1]. However, since this method uses zero-phase without estimating the phase, it causes the internalization (i.e., the inside-the-head localization) of sound when listening the spatial sound. We devise a method to estimate both the magnitude and phase of HRTF based on the DNN model. Personalized HRIR was estimated using the anthropometric measurements including detailed data of the head, torso, shoulders and ears as inputs for the DNN model. After that, the estimated HRIR was filtered with an appropriate notch filter to improve elevation reproduction. In order to evaluate the performance, both of the objective and subjective evaluations are conducted. For the objective evaluation, the root mean square error (RMSE) and the log spectral distance (LSD) between the reference HRTF and the estimated HRTF are measured. For subjective evaluation, the MUSHRA test and preference test are conducted. As a result, the proposed method can make listeners experience more immersive audio than the previous methods.

여과 성능향상을 위한 이단이층 복합여과시스템의 공정선정 연구 (A Study on the Process Selection for Two-stage and Dual Media Filtration System for Improving Filtration Performance)

  • 송시범;조민;남상호;우달식
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.203-214
    • /
    • 2007
  • This study aimed at researching the process selection for two-stage and dual media filtration system, as a technology substituting the existing sand filter without expanding the site when retrofitting an old filter bed or designing a new one. In order to select the process for optimum complex filtration system, three running conditions have been tested. Test results demonstrated that Run 3 in which the 1st stage was filled with anthracite and coarse sand, and the 2nd stage was filled up with activated carbon and fine sand reduced the head loss and the load of turbidity substances. Also, Run 3 showed better performance in removing TOC, particle counts, THMFP and HAAFP, compared to other two conditions. 99 % of Cryptosporidium was removed. Bisphenol-A was rarely removed from the 1st stage of coarse sand and 2nd stage of fine sand, but 99 % of it was removed from the 2nd stage of activated carbon. In conclusion, when it is required to retrofit an old rapid filter bed or design a new one for the purpose of improving filtration performance, the following two-stage and dual media filtration system is suggested: the 1st stage of filter bed needs to be filled up with coarse sand to remove turbidity as the pretreatment for extending duration of filtering, the top part of 2nd stage needs to be filled up with granular activated caron to remove dissolved organic matters and others as the main process, and finally the bottom part of 2nd stage needs to be filled up with fine sand as the finishing process.

Direct Horizontal-Flow Roughing Filtration의 조립 여상에서의 입자 제거 모델링 (Modeling of Particle Removal in the Coarse Media of Direct Horizontal-Flow Roughing Filtration)

  • 안효원;박노석;이선주;이경혁;왕창근
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.338-347
    • /
    • 2005
  • Horizontal-Flow Roughing Filtration (HRF) is one of altemative pretreatment methods e.g. prior to Slow Sand Filtration (SSF). However, some of its limitations are that the effluent quality drops drastically at higher turbidity (>200 NTU) and at higher filtration rate (>1 m/h). To overcome these drawbacks, we suggested Direct Horizontal-Flow Roughing Filtration (DHRF), which is a modified system of Horizontal-Flow Roughing (HRF) by addition of low dose of coagulant prior to filtration. In this study to optimize the DHRF configuration, a conceptual and mathematical model for the coarse compartment has been developed in analogy with multi-plate settlers. Data from simple column settling test can be used in the model to predict the filter performance. Furthermore, the model developed herein has been validated by successive experiments carried out. The conventional column settling test has been found to be an handy and useful to predict the performance of DHRF for different raw water characteristics (e.g. coagulated or uncoagulated water, different presence of organic matter, etc.) and different inital process conditions (e.g. coagulant dose, mixing time and intensity, etc.). An optimum filter design for the coarse compartment (grain size 20mm) has been found to be of 3 m/h filtration rate with filter length of 4-4.5 m.

여재의 인 제거기능 회복을 위한 물리화학적 재사용 방안 비교 (Comparisons of Regeneration Methods Using Physical and Chemical Treatment for Phosphate Removal Restoration of Filter Media)

  • 김지아;최이송;오종민;김원재;박재로
    • Ecology and Resilient Infrastructure
    • /
    • 제3권3호
    • /
    • pp.201-206
    • /
    • 2016
  • 본 연구에서는 물리화학적 처리를 통하여 여재의 인 흡착능 회복을 위한 재생 방안을 연구하는 데 그 목적을 둔다. 실험에 사용한 여재는 Adphos이다. 열 처리 방법의 경우, 기 사용한 여재를 고온에 가열한 후 흡착실험을 수행한 결과, 재사용 여재의 $PO{_4}^{3-}-P$ 흡착량은 0.0021 - 0.0030 mg/g, 제거효율은 26.1 - 39.4%의 범위로 나타났다. 산 또는 pH 조건을 조절하여 수행한 실험 결과, 산성을 띠는 pH 1 - pH 5 조건에 처리한 경우 재사용 여재의 $PO{_4}^{3-}-P$ 흡착량은 0.0010 - 0.0066 mg/g, 제거효율은 15.8 - 87.1% 범위로 나타났다. 염기성을 띠는 pH 8 - pH 11 조건에 처리한 경우 재사용 여재의 $PO{_4}^{3-}-P$ 흡착량은 0.0018 - 0.0034 mg/g, 제거효율은 26.7 - 48.0% 범위로 조사되었다. 0.1 M, 0.01 M, 0.001 M 농도의 NaCl에 처리한 경우 재사용 여재의 $PO{_4}^{3-}-P$ 흡착량은 0.0036 - 0.0050 mg/g, 제거효율은 50.5 - 71.1%로 나타나 0.1 M NaCl을 이용한 약품처리법에서 재사용 여재의 인 흡착능 회복성이 높은 것으로 조사되었다.

압축성 여재 여과를 이용한 하수의 고형물질 제거 타당성 연구 (Feasibility Study on Removal of Total Suspended Solid in Wastewater with Compressed Media Filter)

  • 김예슬;정찬일;오재일;윤여민
    • 대한환경공학회지
    • /
    • 제36권2호
    • /
    • pp.84-95
    • /
    • 2014
  • 최근 미국과 일본을 중심으로 높은 공극과 압축성이라는 장점을 지닌 압축성 섬유여재 여과에 대한 다양한 기술이 개발되면서 이를 이용한 집약적 하 폐수 처리에 대한 관심이 높아지고 있다. 이에 따라 본 연구에서는 다양한 유입수질의 하수에 대하여 압축성 섬유여재 여과의 적용성을 검토하고자 하며, 해당 유입수에 대한 최적의 운전조건을 도출하고자 한다. 이를 위하여 예비 실험으로서 추적자 시험을 진행하였으며, 이를 통하여 다양한 압축률 및 여과율에서의 여과 양상을 검토하였다. 그 결과 높은 압축률에서 높이에 따라 다른 공극률이 적용되어 이론적인 결과값과의 뚜렷한 차이를 관찰할 수 있었다. 하수처리장의 침사지 유출수를 대상으로 다양한 압축률 조건에서 압축성 섬유여재 여과의 TSS 제거 및 제거 입자크기분포를 살펴본 결과, 압축률 30%가 최적의 운전조건으로서 제거효율 70% 이상을 나타냈으며, 작은 크기의 입자 제거율 증대를 위해 최소 15% 이상의 압축률이 요구되었다. 또한 여과 유출수 농도의 주요 영향인자인 $10{\mu}m$ 이하 입자의 제거 효율을 증대시키기 위해서는 응집과 같은 추가 공정이 필요하다고 판단되었다. 모델링 결과를 통하여 압축률이 증가할수록 여과 초기에 입자 크기에 따른 TSS 제거효율이 두드러지게 나타남을 관찰하였고, 유입수의 입자크기분포에서 가장 큰 비율을 차지하는 $10{\mu}m$ 크기 입자를 대상으로 높이에 따른 모델링 결과 높이 150-300 mm 여재층이 해당 입자 크기에 대하여 가장 활발한 여과 작용을 나타내었다.