• Title/Summary/Keyword: File Transfer

Search Result 209, Processing Time 0.026 seconds

Efficient Support for Adaptive Bandwidth Scheduling in Video Servers (비디오 서버에서의 효율적인 대역폭 스케줄링 지원)

  • Lee, Won-Jun
    • The KIPS Transactions:PartC
    • /
    • v.9C no.2
    • /
    • pp.297-306
    • /
    • 2002
  • Continuous multimedia applications require a guaranteed retricval and transfer rate of streaming data, which conventional file server mechanism generally does not provide. In this paper we describe a dynamic negotiated admission control and dick bandwidth scheduling framework for Continuous Media (CM : e.g., video) servers. The framework consists of two parts. One is a reserve-based admission control mechanism and the other part is a scheduler for continuous media streams with dynamic resource allocation to achieve higher utilization than non-dynamic scheduler by effectively sharing available resources among contending streams to improve overall QoS. Using our policy, we could increase the number of simultaneously running: clients that coo]d be supported and cot]d ensure a good response ratio and better resource utilization under heavy traffic requirements.

Development of ePosition Application Technology Based on ENC Data (전자해도 데이터 기반 ePosition 연계기술개발)

  • Seo, Ki-Yeol;Kim, Kyung-Hun;Lee, Sang-Zee;Oh, Se-Woong;Park, Jong-Min;Suh, Sang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.7
    • /
    • pp.1305-1310
    • /
    • 2007
  • ePosition is a technology that can provide the spacial position of the earth to the information of ePosition ID through the Internet. It is serving the information of land location based on the Internet using the ePosition technology now, but it needs the service technique which can supply the marine data and the information of maritime position. Moreover, to support the information service of marine position, it needs the ENC linked technique based on S-57 that is an IHO transfer standard for digital hydrographic data. In this paper, therefore, it develops a linkage method for applying and utilizing the ePosition technology to ENC data, and supplements the base technology for applying it to marine related fields. As study method, firstly, this paper analyses ENC data model and structure, and converses for processing ENC file to ePosition data. Lastly, it derives the interconnection method with ePosition database and shows the ePosition service application based on the linked data and its validity.

3GPP Standardization Activity for Small Cell Enhancement (3GPP 소형셀 향상 표준화 기술 동향)

  • Baek, SeungKwon;Chang, SungCheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.628-631
    • /
    • 2014
  • Recently, the proliferation of new applications, e.g., mobile TV, Internet gaming, large file transfer, and the various of user terminals, e.g., smart phones and notebooks, has dramatically increased user traffic and network load. In order to meet this traffic growth, vendors and cellular operators are working on the development of new technologies and cellular standards. Within them, small cell deployment has been heralded as one of most promising way to increase both coverage and capacity of future cellular network. Small cell technology enables to improve capacity of cellular radio network by tight cooperation between small cell and macro cell in multi-tier network where small cells are densely deployed within macro cell coverage. In this paper, we describe the deployment scenarios for cooperation between macro cell and small cells and state-of-the-art technologies related to dense small cell deployment. Then, we also provide design principles and standardization trends for small cell enhancement in 3GPP.

  • PDF

A Study on the Application of Zero Copy Technology to Improve the Transmission Efficiency and Recording Performance of Massive Data (대용량 데이터의 전송 효율 및 기록 성능 향상을 위한 Zero Copy 기술 적용에 관한 연구)

  • Song, Min-Gyu;Kim, Hyo-Ryoung;Kang, Yong-Woo;Je, Do-Heung;Wi, Seog-Oh;Lee, Sung-Mo;Kim, Seung-Rae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1133-1144
    • /
    • 2021
  • Zero-copy is a technology that is also called no-memory copy, and through its use, context switching between the user space and the kernel space can be reduced to minimize the load on the CPU. However, this technology is only used to transmit small random files, and has not yet been widely used for large file transfers. This paper intends to discuss the practical application of zero-copy in processing large files via a network. To this end, we first developed a small test bed and program that can transmit and store data based on zero-copy. Afterwards, we intend to verify the usefulness of the applied technology in detail through detailed performance evaluation

Design and Implementation of Medical Information System using QR Code (QR 코드를 이용한 의료정보 시스템 설계 및 구현)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • The new medical device technologies for bio-signal information and medical information which developed in various forms have been increasing. Information gathering techniques and the increasing of the bio-signal information device are being used as the main information of the medical service in everyday life. Hence, there is increasing in utilization of the various bio-signals, but it has a problem that does not account for security reasons. Furthermore, the medical image information and bio-signal of the patient in medical field is generated by the individual device, that make the situation cannot be managed and integrated. In order to solve that problem, in this paper we integrated the QR code signal associated with the medial image information including the finding of the doctor and the bio-signal information. bio-signal. System implementation environment for medical imaging devices and bio-signal acquisition was configured through bio-signal measurement, smart device and PC. For the ROI extraction of bio-signal and the receiving of image information that transfer from the medical equipment or bio-signal measurement, .NET Framework was used to operate the QR server module on Window Server 2008 operating system. The main function of the QR server module is to parse the DICOM file generated from the medical imaging device and extract the identified ROI information to store and manage in the database. Additionally, EMR, patient health information such as OCS, extracted ROI information needed for basic information and emergency situation is managed by QR code. QR code and ROI management and the bio-signal information file also store and manage depending on the size of receiving the bio-singnal information case with a PID (patient identification) to be used by the bio-signal device. If the receiving of information is not less than the maximum size to be converted into a QR code, the QR code and the URL information can access the bio-signal information through the server. Likewise, .Net Framework is installed to provide the information in the form of the QR code, so the client can check and find the relevant information through PC and android-based smart device. Finally, the existing medical imaging information, bio-signal information and the health information of the patient are integrated over the result of executing the application service in order to provide a medical information service which is suitable in medical field.

Comparative accuracy of implant impression techniques with different splinting materials (임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교)

  • Ki-Yoon Hong;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • Purpose: We investigated the effect of open tray impression using pick-up impression coping and close tray impression using transfer impression coping on the accuracy of impression in edentulous patients on their mandibular parts. the effect of material types of pick-up type impression copings for splinting in open tray impression on the accuracy of impression was also evaluated. Materials and Methods: Two implant fixtures were implanted in parallel in the left molar of the mandibular in the shape of a mandibular partial edentulous model. The 40 individual trays were fabricated using 3D printer. The prepared individual trays were classified into 4 groups (i.e., PN, PG, PH, and TN groups), and a total of 40 impression-takings were conducted. A master cast was connected to a Scan Body. The converted STL file was super-imposed on the scan images of the various groups. Results: The order of standard deviation values decreased as follows: PN (0.2343 ± 0.0844 mm), TN (0.2192 ± 0.0840 mm), indicating that the high accuracy of impression for TN group. In addition, for the comparison results between the material types used in splinting the open tray impression, the PH group showed a relatively lower standard deviation (0.1910 ± 0.1176 mm) than that of the PN group (0.2343 ± 0.0844 mm), PG group (0.2556 ± 0.1082 mm). Conclusion: The acrylic resin synthesized by light-induced polymerization exhibited a higher accuracy of impression taking than that of autopolymerizing acrylic resin. Meanwhile, the accuracy of impression taking was not dependent on the implant impression taking method or the presence of connection/fixation of impression copings.

Usefulness of "Volumetrix Suite" with SPECT/CT (SPECT/CT 영상에서 Volumetrix Suite의 유용성)

  • Cho, Seung-Wook;Shin, Byeong-Ho;Kim, Jong-Pil;Yoon, Seok-Hwan;Kim, Tae-Yeub;Seung, Yong-Joon;Moon, Il-Sang;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Purpose: The SPECT/CT is able to acquire diagnostic information resolved the difficult problems that discriminate regions of focals by intergrating functional images and anatomical images. We introduce the usefulness of "Volumetrix Suite" which can describe 3D images by the convergence of the SPECT/CT images and reference CT images. Materials and Methods: We applied Volumetrix Suite program (Volumetrix IR, Volumetrix 3D) to patients, Bone, Venography, Parathyroid, WBC, taken diagnostic CT examination which have same regions of focal in Seoul Metropolitan Government Seoul National University Boramae Medical Center. After acquiring SPECT/CT images and reference CT images, we fused a couple of scans applying for this programs. The CT scan of Infinia Hawkeye 4 shows limitation of anatomical information. For this reason, we tried to transfer CT images that have lots of diagnostic informations as the form of Dicom file in PACS, and changed from 2D images to 3D images after image registering in Xeleris Workstaion of Hawkeye 4. Results & Conclusion: By using Volumetrix Suite program, we're able to acquire more accurate anatomical informations with 3D rendering which can distinguish both location and range of focals in Infinia Hawkeye 4. Thus, the result of utilizing this program indicate that nuclear medicine anatomical images can be improved by providing more diagnostic imformations produced by its program.

  • PDF

Performance Evaluation of Workstation System within ATM Integrated Service Switching System using Mean Value Analysis Algorithm (MVA 알고리즘을 이용한 ATM 기반 통합 서비스 교환기 내 워크스테이션의 성능 평가)

  • Jang, Seung-Ju;Kim, Gil-Yong;Lee, Jae-Hum;Park, Ho-Jin
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.6 no.4
    • /
    • pp.421-429
    • /
    • 2000
  • In present, ATM integrated switching system has been developed to a mixed modules that complexed switching system including maintenance, operation based on B-ISDN/LAN service and plug-in module, , which runs on workstation computer system. Meanwhile, workstation has HMI operation system feature including file system management, time management, graphic processing, TMN agent function. The workstation has communicated with between ATM switching module and clients. This computer system architecture has much burden messages communication among processes or processor. These messages communication consume system resources which are socket, message queue, IO device files, regular files, and so on. Therefore, in this paper we proposed new performance modeling with this system architecture. We will analyze the system bottleneck and improve system performance. In addition, in the future, the system has many additional features should be migrated to workstation system, we need previously to evaluate system bottleneck and redesign it. In performance model, we use queueing network model and the simulation package is used PDQ and C-program.

  • PDF

A Study on File Transfer Methods on IEEE-1394 Serial Bus (IEEE-1394 버스에서의 파일 전송 기법에 연구)

  • 편기현;강성일;이흥규
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10a
    • /
    • pp.261-263
    • /
    • 1998
  • IEEE-1394 버스(이하 13394 버스)는 가정용 가전기기와 컴퓨터를 서로연결 할 수 있는 버스로 100Mbps, 200Mbps, 400Mbps의 광대역폭을 제공하고 데이터를 전달하는 방법으로 비동기 (asynchromous)전송뿐만 아니라 등시성(isochronous)전송도 제공한다. 비동기 전송은 시간의 제약이 없고 정확한 전달이 필요한 데이터에 적합한 반면 등시성 전송은 실시간을 요구하고정확한 전잘이 필요없는 데이터에 적합한 특성을 가진다. 1394 버스는 멀티미디어 데이터를 생성하고 편집하는 장치들을 서로 연결시키고 기존의 LAN이 갖는 대역폭의 부족과 프로토콜살의 실시간 전송 방법의 부재 때문에 진정한 의미의 실시간 구현이 어려웠던 화상 전화기, 화상회의 시스템, 비디오편집 시스템을 가능하게 한다. 이러한 멀티미디어 응용 시스템은1)대용향의 멀티미디어 파일 전송을 필요로 하고 화상전화기 혹은 화상회의 시스템은 2) 고속의 파일 전송을 요구하게 된다. 또 두사람이 화상 전화기를 통해 통신을 하면서 여러 가지 문서를 교환하는 경우 최대한 빠르게 파일 전송이 완료될 필요가 있다. 현재 1394버스에서 IP가 올리는 일이 진행중이므로 기존의 FTP는 사용할 수 없다. 게다가 1394 버스에 IP가 올라가더라도 1394 버스 내에서 대용량의 파일을 더 빠르고 정확하게 전달하기 위해서는 IP오버헤드가 없고 1394 버스의 특성을 직접 이용한 새로운 파일 전송 기법이 필요하다. 1394 버스내에서 대용량의 파일을 빠르고 정확하게 전송하는 기법을 찾기 위해서는 비동기 전송과 등기성 전송의 특성을 잘 이해해야하고 각 전송 방법으로 파일을 전송 할 때 생기는 장단점들을 파악해야한다. 본 논문에서는 비동기 전송과 등기성 전송을 이용한 팔일 전송 기법을 각각 제시하고 실험을 통해 이들의 특성을 비교분석하였다.미에서 uronic acid 함량이 두 배 이상으로 나타났다. 흑미의 uronic acid 함량이 가장 많이 용출된 분획은 sodium hydroxide 부분으로서 hemicellulose구조가 polyuronic acid의 형태인 것으로 사료된다. 추출획분의 구성단당은 여러 곡물연구의 보고와 유사하게 glucose, arabinose, xylose 함량이 대체로 높게 나타났다. 점미가 수가용성분에서 goucose대비 용출함량이 고르게 나타나는 경향을 보였고 흑미는 알칼리가용분에서 glucose가 상당량(0.68%) 포함되고 있음을 보여주었고 arabinose(0.68%), xylose(0.05%)도 다른 종류에 비해서 다량 함유한 것으로 나타났다. 흑미는 총식이섬유 함량이 높고 pectic substances, hemicellulose, uronic acid 함량이 높아서 콜레스테롤 저하 등의 효과가 기대되며 고섬유식품으로서 조리 특성 연구가 필요한 것으로 사료된다.리하였다. 얻어진 소견(所見)은 다음과 같았다. 1. 모년령(母年齡), 임신회수(姙娠回數), 임신기간(姙娠其間), 출산시체중등(出産時體重等)의 제요인(諸要因)은 주산기사망(周産基死亡)에 대(對)하여 통계적(統計的)으로 유의(有意)한 영향을 미치고 있어 $25{\sim}29$세(歲)의 연령군에서, 2번째 임신과 2번째의 출산에서 그리고 만삭의 임신 기간에, 출산시체중(出産時體重) $3.50{\sim}3.99kg$사이의 아이에서 그 주산기사망률(周産基死亡率)이 각각 가장 낮았다. 2. 사산(死産)과 초생아사망(初生兒死亡)을 구분(區分)하여 고려해 볼때 사산(死産)은 모성(母性)의 임신력(姙娠歷)과 매우 밀접한 관련이 있는 것으로 사료(思料)되었고 초생아사망(初生兒死亡)은 미숙아(未熟兒)와 이에 관련된 병발이 거의 결정

  • PDF

The Preliminary Operator Risk Assessment of High Toxicological Pesticides in Korea (고독성 농약의 국내 농작업자 위해성 평가)

  • Hong, Soon-Sung;Jeong, Mi-Hye;Park, Kyung-Hun;You, Are-Sun;Park, Yeon-Ki;Lee, Je-Bong;Kim, Chan-Sub;Shin, Jin-Sup;Park, Jae-Eup
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.2
    • /
    • pp.116-122
    • /
    • 2010
  • This study was carried out to estimate the risk of pesticide operators who use high toxicological pesticides. The class II (highly hazardous) pesticides registered in korea were 15 products, and 11 products were spray type pesticides at orchard file in 2009. The using information based on the pesticide label and the data searched through survey of actual condition on pesticides were used for calculate the pesticide operator exposure dose. The risk quotients of these pesticides against the pesticides operator were calculated as devide pesticide exposure dose by reference dose which were presented by EFSA (European Food Safety Authority), JMPR (Joint FAO Meeting on Pesticide Residues), and US/EPA (United States Environmental Protection Agency). Omethoate showed the highest risk quotient and the values were 338 and 75 when the operator spray using speed sprayer and motor sprayer respectively. Risk quotients of all class II pesticide were above 1. This result means that the risk potential of these pesticides are very high.