• Title/Summary/Keyword: Field-in-field technique

Search Result 4,916, Processing Time 0.03 seconds

Multi-axial Vibration Test on MAST System with Field Data (국내도로 주행 시험을 통한 6축 진동시험 방법에 관한 연구)

  • Kim, Chan-Jung;Bae, Chul-Yong;Lee, Bang-Hyun;Kwon, Seong-Jin;Na, Byung-Chul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.704-711
    • /
    • 2006
  • Vibration test on MAST(multi axial simulation table) system has several advantage over one-axial vibration test that could simulate 6-DOF, 3-axial translation and 3-axial moment, at the same time. Since field vibration motion can be fully represented with 6-DOF, multi-axial vibration test on vehicle component is widely conducted in technical leading companies to make sure its fatigue performance in vibration environment. On the way to fulfill the process, editing technique of obtained field data is key issue to success a reliable vibration testing with MAST system. Since the original signals are not only too large to fulfill it directly, but all of the measured data is not guarantee its convergency on generating its driving files, editing technique of the original signals are highly required to make some events that should meet the equal fatigue damage on the target component In this paper, key technique on editing a field data feasible for MAST system is described based on energy method in vibration fatigue. To explain its technique explicitly, author first introduced a process on field data acquisition of two vehicle component and then, representing events are produced to keep up with the editing strategy about a energy method. In the final chapter, a time information regarding a vibration test on MAST system is derived from the energy data which is critical information to perform a vibration test.

Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.

Performance Comparison of Pressure Sensitive Paint and Pressure Field Measurement of Oblique Impinging Jet (Pressure Sensitive Paint의 성능비교 및 경사충돌분류의 압력장 측정)

  • Lee, Sang-Ik;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.1031-1038
    • /
    • 2002
  • The pressure sensitive paint (PSP) has recently received a considerable attention in the fields of aerodynamics and fluid mechanics as a new revolutionary optical technique to measure pressure fields on a body surface. In this study, the feasibility and effectiveness of the PSP pressure field measurement technique have been investigated experimentally. Seven different PSP formulations including two porphyrins(PtOEP and PtTFPP) and four polymers(Polystyrene, cellulous acetate butyrate, GP-197 and Silicon-708) were tested to check the performance and characteristics of each combination. The static calibration of each PSP formulation was carried out in a constant-pressure chamber. The PSP technique was applied to an oblique impinging jet flow to measure variation of pressure field on the impinging plate at on oblique jet angle of ${\theta}=60^{\circ}$. Pressure field images were captured by an 12bit intensified CCD(ICCD, $1K{\times}1K$)camera. As a result, the dynamic response of PSP depends on the oxygen permeability of polymer and the photochemical interaction between luminophore and polymer as well as the reaction of luminophore itself. The reaction of luminophore was changed by employing different polymers. In conclusion, Among 7 PSP formulation tested, the combination of PtTFPP and cellulous acetate butyrate show the best performance. In addition, the detail pressure field of an oblique high-speed impinging jet was measured effectively using the PSP technique.

MAST Vibration on MAST System with Field Data (국내도로 주행 시험을 통한 6축 진동시험 방법에 관한 연구)

  • Kim, Chan-Jung;Bae, Chul-Yong;Lee, Bong-Hyun;Kwon, Seong-Jin;Na, Byung-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.764-769
    • /
    • 2006
  • Vibration test on MAST(multi axial simulation table) system has several advantage over one-axial vibration test that could simulate 6-DOF, 3-axial translation and 3-axial moment, at the same time. Since field vibration motion can be fully represented with 6-DOF, multi-axial vibration test on vehicle component is widely conducted in technical leading companies to make sure its fatigue performance in vibration environment. On the way to fulfill the process, editing technique of obtained field data is key issue to success a reliable vibration testing with MAST system. Since the original signals are not only too large to fulfill it directly, but all of the measured data is not guarantee its convergency on generating its driving files, editing technique of the original signals are highly required to make some events that should meet the equal fatigue damage on the target component In this paper, key technique on editing a field data feasible for MAST system is described based on energy method in vibration fatigue. To explain its technique explicitly, author first introduced a process on field data acquisition of two vehicle component and then, representing events are produced to keep up with the editing strategy about a energy method. In the final chapter, a time information regarding a vibration test on MAST system is derived from the energy data which is critical information to perform a vibration test.

  • PDF

A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements (현장실측에 의한 메시(Mesh)접지저항 출정기법 연구)

  • 한기붕;김삼수;정세중;이상익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

Optimum AC losses Determination for Duty Cycle of Superconductive Magnetic Energy Storage (초전도에너지 저장장치의 운전주기에 따른 최적교류손실 결정에 관한 연구)

  • Hwang, Seuk-Yong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.7
    • /
    • pp.653-667
    • /
    • 1990
  • Superconductor is consolidated, for required current capacity, with proper numbers of basic strands which are multifilamentary composites. Althouth superconductors are perfectly loss-free under DC conditions of current and field, AC losses occur under time-varying condition of the current and field. The AC losses are a controllable inherent characteristics of supercondectors. The AC losses dependent on the changing rate of current and field can be reduced by reducing the filament diameter. On the other hand, finer filament results in manufacturing cost increase. Therefore, in this paper optimization technique of superconductor for SMES is proposed from the viewpoint of AC loss reduction and manufacturing cost increase. The case study shows that the technique can be effectively used for the design of superconductor for SMES, appreciating the influence of various parameters related to superconductor itself and operating condition of SMES. As a result of the case study, it is confirmed that the technique is more effective for the design of superconductor for SMES for electric power power system stabilization rather then SMES for energy storage.

  • PDF

Dosimetry of Irregular Field Using Thermoluminescence Dosimetry (부정형 조사면에서의 TLD를 이용한 방사선 흡수선량 측정)

  • Lee, Jong-Young;Park, Kyung-Ran;Kim, Kye-Jun
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.263-267
    • /
    • 1994
  • In clinical radiotherapy, the use of wide and irregular field techniques frequently results in considerable tumor dose inhomogeneity because of, the variation in physical characteristics of irradiated volumes. This report describes an analysis of the dosimetry of the irregular fields such as radiation fields for Hodgkin's disease(mantle field), esophageal cancer, and lung cancer when a 6 MV and a 15 MV linear accelerators are utilized. Doses were measured in a Rando phantom using methods of thermoluminescence dosimetry(TLD), and were calculated by radiotherapy planning computer system with the Clarkson's method for calculation of a irregular field. A dose variation of $5-22\%,\;6-9\%,\;6-14\%$ were found in the mantle field, esophageal cancer field, lung cancer field respectively. Higher doses occurred in the superior portion of the irregular field. The sites of maximum dose variation were the supraclavicular and the upper spinal cord region. To adjust for these substantial differences, a compensator or a shrinking field technique should be adopted.

  • PDF

High-Accuracy Current Sensing Technique Based on Magnetic Sensors for Three-Phase Switchboards (삼상 배전반에서 자기센서 기반의 고정밀 전류 측정 기법)

  • Lee, Sungho;Kim, Taemin;Kim, Namsu;Ahn, Youngho;Lee, Sungchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.12
    • /
    • pp.993-998
    • /
    • 2017
  • In this paper, a high-accuracy current sensing technique for three-phase current paths in an electrical switchboard is proposed. Conventional open-style current sensors using magnetic sensors show inaccurate sensing performance with more than 10% error due to undesired magnetic field interference from neighboring paths. To increase accuracy, large and expensive current transformers with large permeabilities have been used, which increased the cost and size. The proposed technique can improve the measured magnetic field by the calculation of magnetic interference effect from neighboring current paths. The relationship between neighboring magnetic fields and the desired magnetic field is theoretically analyzed in a general case. The proposed technique is verified using magnetic field simulations in a three-phase busbar environment.

Development of Micro-size Search Coil Magnetometer for Magnetic Field Distribution Measurement

  • Ka, E.M.;Son, De-Rac
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.34-36
    • /
    • 2008
  • For the measurement of the magnetic field distribution with high spatial resolution and high accuracy, the magnetic field sensing probe must be non-magnetic, but the MFM probe and sub-millimeter-meter size Hall probe use a ferromagnetic tip and block, respectively, to increase the sensitivity. To overcome this drawback, we developed a micro-size search coil magnetometer which consists of a single turn search coil, Terfenol-D actuator, scanning system, and control software. To reduce the noise generated by the stray ac magnetic field of the actuator driving coil, we employed an even function $\lambda$-H magnetostriction curve and lock-in technique. Using the developed magnetometer, we were able to measure the magnetic field distribution with a magnetic field resolution of 1 mT and spatial resolution of $0.1mm{\times}0.2mm$ at a coil vibration frequency of 1.8 kHz.

Azimuthal anchoring measurement of nematic liquid crystals using the strong magnetic field

  • Jang, Tae-Sug;Im, Ji-Young;Goh, Wan-Hee;Kim, Jong-Hyun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.664-667
    • /
    • 2009
  • We would like to show a measuring technique of azimuthal anchoring energy of the nematic liquid crystals. The electro-optical setup of liquid crystal cell, crossed polarizers and magnetic field was assumed. The planar or hybrid alignment cells were prepared. The director in the light entering substrate and the polarization of light was adjusted into parallel to the magnetic field. The director orientation of exit substrate and analyser maintained perpendicular to the magnetic field. As the magnetic field strength is increased, the director deviates from the easy axis and rotates to the field direction. We obtained an equation calculating the change of transmission with the field and measured experimentally the transmission. By comparing the calculating and experimental data, we obtained the azimuthal anchoring strength.

  • PDF