• Title/Summary/Keyword: Field utilization factor

Search Result 108, Processing Time 0.028 seconds

Analysis on the Dielectric Characteristics of Various Insulation Gases for Developing a Sub-cooled Liquid Nitrogen Cooling System (과냉질소 냉각시스템 가압용 기체의 절연내력특성 분석)

  • Kang, H.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.27-30
    • /
    • 2011
  • A sub-cooled liquid nitrogen cooling system is known as a most promising method to develop large scale superconducting apparatuses such as superconducting fault current limiters and superconducting cables [1]. Gaseous helium (GHe), gaseous nitrogen ($GN_2$) and sulfur hexafluoride ($SF_6$) are commonly used for designing an high voltage applied superconducting device as an injection gaseous medium [2, 3]. In this paper, the analysis on the dielectric characteristics of GHe, $GN_2$ and $SF_6$ are conducted by designing and manufacturing sphere-to-plane electrode systems. The AC withstand voltage experiments on the various gaseous insulation media are carried out and the results are analyzed by using finite element method (FEM) considering field utilization factors (${\xi}$). It is found that the electric field intensity at sparkover ($E_{MAX}$) of insulation media exponentially decreases according to ${\xi}$ increases. Also, the empirical expressions of the functional relations between $E_{MAX}$ and ${\xi}$ of insulation media are deduced by dielectric experiments and computational analyses. It is expected that the electrical insulation design of applied superconducting devices could be performed by using the deduced empirical formulae without dielectric experiments.

A Study on the Dielectric Characteristics of GFRP in LN2 under Lightning Impulse Voltage According to Pressure (액체질소 내에서 뇌 임펄스전압에 대한 압력별 GFRP의 절연파괴 특성 분석)

  • Hong, Jong-Gi;Heo, Jeong-Il;Nam, Seok-Ho;Kang, Hyoung-Kul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1471-1476
    • /
    • 2012
  • A study on the dielectric characteristics of the Glass Fiber Reinforced Plastic (GFRP) is important for designing a reliable high voltage superconducting machines such as transmission superconducting fault current limiters, superconducting cables, and superconducting transformers. In this paper, dielectric experiments of the GFRP under lightning impulse voltage are conducted in liquid nitrogen($LN_2$) according to various experimental conditions such as the thicknesses of the GFRP, the diameters of electrode systems and the pressures. The dielectric characteristics of the GFRP are analyzed by using a Finite Elements Method(FEM) according to various field utilization factors. It has been reported that the electrical insulation design of the GFRP would be conducted by considering the mean electric field intensity($E_{mean}$) distributed inside the GFRP. In this study, it is found that the dielectric performance of the GFRP could be explained by not only $E_{mean}$ but also the maximum electric field intensity ($E_{max}$). Finally, the empirical formulae of the GFRP to estimate an electrical breakdown voltage at sparkover under the lightning impulse condition are deduced. It is expected that the presented experimental results in this paper are helpful to design electrically reliable high voltage superconducting machines using the GFRP as an insulation material.

Analytical and Experimental studies on Dielectric Characteristics of High Voltage Superconducting Machines in Liquid Nitrogen (액체질소를 사용하는 초전도 고전압 전력기기의 절연 특성 연구)

  • Na, J.B.;Ko, T.K.;Kang, H.;Seok, B.Y.;Kim, T.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.46-50
    • /
    • 2011
  • The electrical insulation design of high voltage superconducting fault current limiters (SFCLs) should be confirmed to be applied for the stabilization of the power grid. This paper describes numerical analysis and AC dielectric experiments for developing high voltage SFCLs. The electric field distributions between applied high voltage part and ground were calculated by finite element method (FEM) simulation tool and AC criterion of liquid nitrogen at 200 kPa was calculated from correlation between the field utilization factor and FEM simulation results. This paper deals with ceonceptual insulation design of a 154 kV class single-phase no-inductively wound solenoid type SFCL which was focused on gap distance between the cryostat and superconducting coils. Furthermore, the shield ring effect was confirmed to reduce maximum electric field at applied high voltage part.

Analysis of Electric Field Distribution and Characteristics of Volume Resistivity in HDPE/EVA Film for Recycling (재활용을 고려한 HDPE/EVA필름의 전계분포 및 체적저항특성 해석)

  • Lee, Hung-Kyu;Lim, Kee-Joe;Kim, Yong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.801-807
    • /
    • 2008
  • Recently, CV, CN-CV and CNCV-W cable are used for HVDC transmission and distribution cable. However, XLPE which is used as insulation layer of power cable has thermosetting properties. It is very difficult to recycling. In this paper, we prepared HDPE/EVA film, which the blending ratio are 80:20, 70:30, 60:40, 50;50 respectively for the purpose of recycling. Main factor such as electric field distribution and its resistivity in insulation system affected on insulation performance and reliability for HVDC applications. Therefore, electric field distribution formed by space charge and characteristics of volume resistivity was currently investigated. We suggest the possibility of utilization for HVDC insulation layer from the results.

The Effect of EAMaturity on Information Management and Performance (EA성숙도가 정보화관리 성과에 미치는 영향에 관한 연구)

  • Yi, Dong-Wook;Juhn, Sung-Hyun;Park, Chan-Uk
    • Journal of Information Technology Services
    • /
    • v.11 no.1
    • /
    • pp.39-58
    • /
    • 2012
  • This study was carried out to figure out the relationship between EAmaturity, information management capacity, and information performance, and find the effect between these variables and the reciprocal causation. The study found that EAmaturity has a positive effect on information resource management and performance. In other words, the effect of input, calculation, management and utilization factors on information planning in EAmaturity showed that calculation, management and utilization factors have a significant effect on the information planning. While the effect of input, calculation, management and utilization factors on information introduction and management showed that only both calculation and utilization have a significant effect on the information management factor. It says that EAinput in EAmaturity does not play a big part in the planning stage, as well as not go through a series of process that is connected to the maturity stage by immediate field application. Consequently, EAmaturity varies from the level that EAcreates introduction and performance according to organization. This suggests that the maturity and performance can be also changed by the level that EAcreates information performance by accepting and using this capability within organization as well as the capability to introduce and fully perform the EAsystem presented in enterprise architecture framework of public sector.

A numerical study on heat transfer and pressure drop of plate heat exchanger using at seawater air conditioning with the variation of channel spaces (채널 간격 변화에 따른 해수냉난방용 판형 열교환기의 열전달과 압력강하에 대한 수치해석적 연구)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Yoon, Jung-In;Son, Chang-Hyo;Jung, Young-Kwon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.704-709
    • /
    • 2014
  • Plate heat exchanger is being applied in the field of marine plants and chemical industry, such as OTEC and SWAC equipment. The study aims to interpret the heat transfer and pressure drop characteristics of plate heat exchangers to determine the geometric design parameters such as the channel space. In this study, heat transfer performance was numerically studied with respect to the variation of channel spaces. The results from numerical analysis indicated that the j factor was linearly decreased with the flowrate of seawater over every cases. As the flowrate of water increased with respect to channel spaces, the j factor decreased linearly. And the f factor decreased linearly with the increase of flowrate. When the channel space is 2.8~3.2 mm and 3.2~3.2 mm, respectively, the area goodness factor of plate heat exchanger showed the highest performance.

Study on the Dielectric Characteristics of Gaseous Nitrogen for Designing a High Voltage Superconducting Fault Current Limiter

  • Heo, Jeong-Il;Hong, Jong-Gi;Nam, Seok-Ho;Kang, Hyoung-Ku
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.2
    • /
    • pp.28-31
    • /
    • 2012
  • The study on the dielectric characteristics of gaseous insulation medium is important for designing current leads of superconducting machines using a sub-cooled liquid nitrogen ($LN_2$) cooling method. In a sub-cooled $LN_2$ cooling system, the temperature of gaseous insulation medium surrounding current leads varies from the temperature of coolant to 300 K according to the displacement between the electrode system and the surface of sub-cooled $LN_2$. In this paper, AC withstand voltage experiments on gaseous nitrogen according to temperature are conducted. Also, AC withstand voltage experiments on gaseous nitrogen according to pressure, size of electrode, and gap length between two electrodes are performed. It is found that there is a functional relation between the electrical breakdown voltage and the field utilization factor (${\xi}$). As a result, the empirical formula for estimating an electrical breakdown voltage is deduced by adopting the concept of field utilization factors. It is expected that the experimental results presented in this paper are helpful to design current leads for a high voltage superconducting apparatus such as a superconducting fault current limiter (SFCL) using a sub-cooled $LN_2$ cooling system.

Utilization of the Outflowing Groundwater Resources in an Underpass Structure

  • Jin, Kyu-Nam;Park, Jae-Hyeon;Lee, Jung-Min;Lee, Sang-Ho
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.117-121
    • /
    • 2013
  • For underpasses in Yeongjong Sky City business district, the guided drainage system, as a buoyancy prevention system has been designed, and is under construction. This paper investigates the safety of the guided drainage system for underpass structures being constructed in Yeongjong Sky City business district. This paper also calculates the amount of outflowing groundwater generated by the guided drainage system, and proposes alternative usages of the water. In order to investigate safety and field applicability of the guided drainage system for underpasses, characteristics of the surface flow for the area of interest have been analyzed, and the flow change of groundwater following the underpass structure construction has been evaluated using the 3-dimensional groundwater program MODFLOW. The influence of ground water on safety of the underpass structures has been calculated by FLAC2D analysis. For alternative usages for the outflowing groundwater generated by the guided drainage system, utilization methods of the outflowing groundwater in national and international resources have been researched. The amount of an outflowing groundwater to be generated in the area of interest has been analyzed, and efficient potential usages of this groundwater have been researched. When guided drainage technique is applied, the change in flow of groundwater must be evaluated and considered as safety factor relating to the buoyancy of the structure. As a result, safety factor demonstrated more than 1.2, meaning that the underpass structure is safe. The amount of subsoil drain generated by the guided drainage system was also analyzed. The quality and amount of water satisfied the standards and volume requirements, so as to make it applicable for a number of uses, such as X, Y, and Z, and should prove to be a valuable resource as the circumstances of the neighboring area change over time. These resources can be used as basic data for future urban water circulation studies, as well as generating research of alternative water usages.

A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.

A Study on the Electrical Breakdown Characteristics of Air according to Electrode Gap (전극 간격에 따른 공기의 절연파괴 특성에 관한 연구)

  • Kang, Jong O;Lee, Onyou;Kim, Junil;Bang, Seungmin;Lee, Hongseok;Lee, Jong Doug;Kang, Hyoungku
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.301-306
    • /
    • 2014
  • Recently in accordance with the rapid development of the industrial society, the accidents caused by dielectric breakdown have been increasing in power grid. It is important to prevent the dielectric breakdown of a high voltage apparatus to reduce the damage from electrical hazards. To establish an electrically reliable database of insulation design criteria for high voltage apparatus, a study on dielectric characteristics test is indispensable. In this study, dielectric characteristics according to field utilization factors (${\xi}$) which are represented as the ratio of mean electric field to maximum electric field are investigated. the dielectric breakdown experiments by using several kinds of electrode systems made with stainless steel are performed by AC breakdown voltage under air-insulation. Also, the experimental results are analyzed by the Weibull distribution. As a result, it is found that the dielectric characteristics of air-insulation are determined by ${\xi}$ as well as arrangement of electrode systems. It is considered that the results of this study would be applicable to designing the air-insulated high voltage apparatuses.