• 제목/요약/키워드: Field pullout test

검색결과 45건 처리시간 0.024초

풍화토지반에서 전기방전에 의한 확공앵커의 극한 인발력 (Ultimate Pullout Capacity of Underreamed Anchors Using Electric Discharge in weathered soil)

  • 김성규;김낙경;김재원;강병철;김태훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1354-1359
    • /
    • 2009
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The anchor is an underreamed anchor by using high voltage electric discharge energy. In this study, a series of field test were carried out in order to find ultimate load of underreamed anchors in weathered soil at the new apartment construction site located in Inchon, Korea. Data were analyzed in order to define a relation between ultimate load and the number of electric discharge.

  • PDF

쐐기형 그라운드앵커의 인발 거동 특성 (Pullout Resistance Characteristics of the Wedge-shaped Ground Anchor)

  • 김정무;정원용;윤용수;정민규;장순호;이용준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1060-1064
    • /
    • 2010
  • Ground anchors are mostly used to improve the resistance capacity of retaining walls. The end of the anchor is connected to retaining wall through tendons and the forces in tendons are transferred to ground. In this study, we plan that the new anchor system increases the tension force in tendons and improves the pullout resistance characteristics of the system. In order to increase the pullout resistance capacity of existing anchor system, the new anchor system is made by attaching four steel sticks to the tip of anchor end. So the field test results showed that the pullout resistance capacity of the wedge-shaped ground anchor was acceptable to elastic displacement range.

  • PDF

신장형 띠형 보강재의 형상에 따른 인발저항 및 시공성능 평가 실험 연구 (The Evaluation of Pullout Resistance and Installation Damage according to the Shape of Flexible Strip Reinforcement)

  • 정재형;김재홍
    • 지질공학
    • /
    • 제31권3호
    • /
    • pp.321-332
    • /
    • 2021
  • 최근 새로운 개념의 보강토 옹벽이 많이 개발되고 있으나, 개발된 보강재에서 발생되는 시공과정에서 문제나 붕괴와 같은 문제의 연구는 부족한 실정이다. 이에 본 연구에서는 신장형 띠형 보강재의 형상에 따른 현장 적용성을 인발저항시험과 내시공성시험으로 평가하고자 하였다. 시험체는 일반적인 신장형 띠형 보강재, 돌기가 부착된 개발된 신장형 띠형 보강재, 지오그리드를 절단하여 만든 띠형 보강재를 사용하여, 신장형 띠형 보강재 형상의 차이에 대한 기초적인 연구를 수행하고 각 보강재료의 장단점을 비교하였다. 연구 결과로서 보강재의 형상에 따른 장·단점을 명확하게 가지고 있는 것으로 나타났으며, 보강토 옹벽의 설치 조건과 뒤채움재의 입도를 고려하여 선택한다면 최선의 보강재를 선택할 수 있을 것으로 나타났다.

펄스방전 그라운드 앵커의 확공 특성에 관한 연구 (Expansion Ratio of Pulse Power Underreamed Anchor)

  • 김낙경;주용선;김성규;서효균;김선주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.1107-1112
    • /
    • 2009
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The pulse powered anchor is an underreamed anchor by using high voltage electrokinetic pulse energy. In this study, a series of field test were carried out in order to find expansion rate related in number of pulse charge. and Anchor pull-out tests were performed at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. Data were analyzed in order to define a relation between expansion rate and ultimate pullout load.

  • PDF

가압식 압축형 지반앵커의 인발저항력 증대효과 및 군효과 특성 (The Effect of Pressurized Grouting on Pullout Resistance and the Group Effect of Compression Ground Anchor)

  • 김태섭;심보경;이규상;이인모
    • 한국지반공학회논문집
    • /
    • 제26권6호
    • /
    • pp.5-19
    • /
    • 2010
  • 본 연구는 가압식 압축형 지반앵커의 실내모형 챔버시험, 현장시험을 통해 가압그라우팅이 지반앵커의 인발저항력에 미치는 영향을 고찰하고 현장 군앵커 인발시험을 통해 압축형 지반앵커의 군효과 특성을 규명하는데 그 목적이 있다. 3가지 시료에 대한 실내시험 결과, 가압그라우팅으로 인한 앵커체의 직경 증가량은 시험값과 공동팽창 이론에 의한 값이 대체적으로 일치하였다. 또한 지반의 투수계수에 따른 가압 그라우팅 최소 주입시간을 제안하였다. 현장시험 결과 가압그라우팅으로 인한 앵커체의 직경 증가, 구근 표면 거칠기 증가, 인발저항력 증가의 효과는 SPT-N치가 작은 상대적으로 연약한 지반에서 가압 그라우팅의 효과가 큰 것을 확인할 수 있었다. 또한 SPT-N치가 50이상인 지반에서는 가압그라우팅의 효과를 기대할 수 없는 것을 확인하였다. 현장시험결과를 바탕으로 단위극한주면마찰력 산정식을 지반의 SPT-N치에 대한 함수로 제안하였다. 또한 현장 군앵커 인발시험 결과를 바탕으로 앵커간격과 영향원추반경의 비 및 앵커간격과 천공직경의 비의 2가지 형태로 압축형 지반앵커에 적합한 군효과 저감률 산정식을 제안하였다.

결합강그리드보강재의 특성 및 적용 (Charateristics of the Jointed Steel-Grid Reinforcement and the Application)

  • 한중근
    • 한국환경복원기술학회지
    • /
    • 제5권3호
    • /
    • pp.15-22
    • /
    • 2002
  • To analysis of the embanked slope stability using a jointed reinforcement, the internal stability and the external stability have to be satisfied, respectively. But, because the lengths of ready-made steel-grid were limited, the reinforcements must be connecting themselves to the reinforcing. In this study, the mechanical test was carried out to investigate the tensile failure and the pullout failure at the joint parts of them, which was based on the analysis of reinforced slope in field. Through the tensile tests in mid-air for the jointed steel-grid, the deformation behavior was seriously observed as follows : deformation of longitudinal member, plastic deformation of longitudinal member and of crank part. Those effects were due to the confining pressure and overburden pressure of the surrounding ground. The bearing resistance at jointed part of jointed steel-grid was due to the latter only. The maximum tensile forces were higher about 20kN~27kN than ultimate pullout resistance, but, the results of those was almost the same in mid-soil. The failures of steel-grid occurred at welded point both of longitudinal members and transverse members and of jointed parts. The strength of jointed parts itself got pullout force about 20kN, which was about 65% for ultimate pullout force of the longitudinal members N=2. To the stability analysis of reinforced structure including the reinforced slope, the studying of connection effects at jointed part of reinforcement members must be considered. Through the results of them, the stability of reinforced structures should be satisfied.

소형 압력 토조내에 타입된 말뚝의 인발 거동과 극한 인발 지지력 결정에 관한 연구 (Study on Pullout Behavior and Determination of Ultimate Uplift Capacity of Pile Driven in Small Pressured Chamber)

  • 최용규
    • 한국지반공학회지:지반
    • /
    • 제11권2호
    • /
    • pp.19-28
    • /
    • 1995
  • 소형 압력 토조(small pressure chamber)를 이용하여 포화된 사질토에 타입된 폐단 강관 말뚝의 인발거동 특성을 연구하였다. 소형 압력 토조 시험에서는 인발 하중이 인발변위와 함께 증가하다가 급작스러운 미끄러짐 변위가 발생되는 현상이 2-3회 반복되다가 완전 인발파괴에 이르게 되는데, 이때 첫번째 미끄러짐 변위가 발생하는 하중의 크기를 극한 인발 지지력으로 정의할 수 있다. 또한, 소형 압력 토조 시험에서는 미세한 시험 조건에 의해서도 극한 인발 지지력의 크기가 50% 이상의 오차를 나타낼 수도 있으므로 모형 지반을 형성할 때마다 인발 재하 시험에 의하여 극한 인발 지지력을 결정하여 사용하는 것이 좋을 것으로 판단되며, 이때 1차 인발 시험에 의해 교란된 지반의 상태는 모형 말뚝의 크기에 적합한 타격에너지를 가해주어 회복시킬 수 있다.

  • PDF

체인 보강재의 현장 인발저항력 평가 (An Evaluation of In-situ the Pullout Resistance of Chain Reinforcement)

  • 김상수;유찬;이봉직;신방웅
    • 한국지반공학회논문집
    • /
    • 제18권4호
    • /
    • pp.339-347
    • /
    • 2002
  • 보강토 옹벽에 체인을 보강재로 사용한 경우의 인발저항력 평가를 위한 현장실험을 실시하였다. 실험에서는 횡방향 부재로 강봉이나 L-형 강재앵글을 고려하였으며, 체인의 길이(20m, 2.5m 그리고 3.0m), 보강재의 조합(체인단독, 체인+강봉 그리고 체인+앵글) 그리고 설치위치 등을 다르게 하여 총 80개소에 대해서 인발실험을 실시하였다. 체인 또는 체인+강봉의 경우, 최대 변위는 평균 150mm였으며, 인발하중은 지속적으로 증가하다가 체인의 극한강도에 도달하면 파단(인장파괴)되는 것으로 나타났다. 그러나 체인에 L-형 앵글을 조합한 경우에는 최대변위가 평균 100mm정도로서 변위 억제에 큰 효과가 있는 것으로 나타났다. 현장에서 측정된 항복 인발하중값을 이론값과 비교했을 때는 보강 방법 또는 연직응력에 따라서 현장 측정값이 이론값 보다 약 1.2~3배정도 큰 것으로 나타났으며, 체인의 길이, 연직하중의 크기, 횡방향 부재의 조합에 따라서 항복 인발하중의 크기는 변화하는 것으로 나타났다. 그러나 강봉과 L-형 앵글사이에 차이는 현저하지 않았다. 체인을 보강재로 사용하는 경우 기존의 이론식을 적용한 설계나 시공은 안전측으로 나타났으나, 체인의 인발 저항력이 너무 과소 평가되어 있다고 판단되었다.

Experimental and numerical investigation of uplift behavior of umbrella-shaped ground anchor

  • Zhu, Hong-Hu;Mei, Guo-Xiong;Xu, Min;Liu, Yi;Yin, Jian-Hua
    • Geomechanics and Engineering
    • /
    • 제7권2호
    • /
    • pp.165-181
    • /
    • 2014
  • In the past decade, different types of underreamed ground anchors have been developed for substructures requiring uplift resistance. This article introduces a new type of umbrella-shaped anchor. The uplift behavior of this ground anchor in clay is studied through a series of laboratory and field uplift tests. The test results show that the umbrella-shaped anchor has higher uplift capacity than conventional anchors. The failure mode of the umbrella-shaped anchor in a large embedment depth can be characterized by an arc failure surface and the dimension of the plastic zone depends on the anchor diameter. The anchor diameter and embedment depth have significant influence on the uplift behavior. A finite element model is established to simulate the pullout of the ground anchor. A parametric study using this model is conducted to study the effects of the elastic modulus, cohesion, and friction angle of soils on the load-displacement relationship of the ground anchor. It is found that the larger the elastic modulus and the shear strength parameters, the higher the uplift capacity of the ground anchor. It is suggested that in engineering design, the soil with stiffer modulus and higher shear strength should be selected as the bearing stratum of this type of anchor.

압력재주입 그라우팅 방식을 이용한 보강재의 인발특성 (Pullout Characteristics of Reinforcing Body Using Pressure Re-injection Grouting Method)

  • 이봉직;김상수;윤준식;이종규
    • 한국지반환경공학회 논문집
    • /
    • 제11권10호
    • /
    • pp.25-31
    • /
    • 2010
  • 사면보강 및 기초공법으로 앵커공법, 소일네일공법 및 소구경 말뚝공법 등이 널리 사용되고 있다. 이들 공법은 공통적으로 보강재를 설치한 후 그라우팅을 실시한다. 국내의 경우 중력식과 가압식 그라우팅 방식을 주로 사용하고 있다. 반면, 재주입 그라우팅 방식은 시공장비와 적용 실적의 부족 및 보강효과 검증이 어려워 널리 적용되지 못하고 있는 실정이다. 재주입 그라우팅은 포스트 그라우팅 방식의 일종으로 그라우트체 주면의 응력을 증대시키고 정착장에 불규칙한 표면을 조성함으로써 그라우트와 지반의 저항을 크게 할 수 있다. 이에 본 연구에서는 그라우팅 주입 방식에 따른 보강효과를 비교하고, 재주입 그라우팅 방식으로 시공된 보강재의 인발특성을 평가하기 위하여 현장실험을 실시하였다. 실험결과 재주입 그라우팅에 따른 인발력 증대를 확인할 수 있었다.