• 제목/요약/키워드: Field impact tests

검색결과 126건 처리시간 0.024초

수질오염 방지를 위한 준설매립공법에 관한 연구 (Dredging and Reclamation Technology for Prevention of Water Pollution)

  • 신은철;오영인;이학주
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.41-45
    • /
    • 2000
  • Geotube is made of permeable but soil-tight geotextile, hydraulically filled with soil include dredged sand and mud, which has been successfully applied in hydraulic and coastal engineering projects. Ceotube method is getting popular and being used a lot in many countries of the world because of the simplicity of the placement and construction, cost effectiveness and minimum impact on the environment, and enable to store & isolate contaminated materials as obtained by harbor dredging. Laboratory tests and field construction were performed to determine the design methodology and construction procedures. From the results of laboratory and field construction, the retention ratio of solid particle is a minimum 86%. The minimum permeability and the tensile strength of geotextile are $\alpha$ x 10$^{-4}$ cm/sec and 20t/m, respectively Also, based on the environmental test results, it can be concluded that this method does meet the Korean EPA standards.

  • PDF

Numerical predictions of the time-dependent temperature field for the 7th Cardington compartment fire test

  • Lopes, Antonio M.G.;Vaz, Gilberto C.;Santiago, Aldina
    • Steel and Composite Structures
    • /
    • 제5권6호
    • /
    • pp.421-441
    • /
    • 2005
  • The present work reports on a numerical simulation of a compartment fire. The fire was modeled using a simplified approach, where combustion is simulated as a volumetric heat release. Computations were performed with the commercial code CFX 5.6. Radiation was modeled with a differential approximation (P1 model), while turbulence effects upon the mean gas flow were dealt with a SST turbulence model. Simulations were carried out using a transient approach, starting at the onset of ignition. Results are provided for the temperature field time evolution, thus allowing a direct comparison with the analytical and experimental data. The high spatial resolution available for the results proved to be of great utility for a more detailed analysis of the thermal impact on the steel structure.

해머 타격 반사법을 이용한 현장 록볼트 건전도 평가 (Integrity evaluation of rock bolts in the field by using hammer-impact reflection method)

  • 유정동;배명호;이용준;민복기;이인모;이종섭
    • 한국터널지하공간학회 논문집
    • /
    • 제11권1호
    • /
    • pp.47-56
    • /
    • 2009
  • 록볼트는 숏크리트와 함께 지하구조물의 주지보재로써 중요한 역할을 수행한다. 따라서 록볼트에 발생된 공동결함은 지하구조물의 안정성에 영향을 줄 수 있다. 최근 록볼트 건전도 평가를 위한 비파괴 검사 방법들 중 피에조 디스크 엘리먼트와 음향방출센서를 사용하는 유도초음파의 투과법과 반사법이 우수한 결과를 보여 주었다. 하지만 피에조 디스크 엘리먼트에서 발생되는 파는 현장에 적용하기에 부족한 에너지의 크기를 가진다. 또한 투과법의 경우 현장에서 록볼트 시공시 피에조 디스크 엘리먼트를 철근 끝단에 설치하여 시공하여야 한다. 본 연구의 목적은 충분한 에너지를 발생시킬 수 있는 유도초음파의 반사법을 개발하고 이를 현장에 시공된 록볼트의 건전도를 경가에 적용하는 것이다. 본 연구는 실내실험과 현장실험으로 수행되었다. 충분한 에너지를 갖는 유도초음파를 록볼트 두부에 자국정을 대고 해머로 타격하여 발생시켰으며, 이를 음향방출센서로 수신하였다. 측정된 신호의 분석을 위해 웨이브렛 변환을 이용하였다. 웨이브렛 변환의 최고점으로부터 에너지 속도를 산정하여 록볼트의 건전도를 평가하였다. 유도초음파의 에너지 속도는 실내에 설치된 록볼트 실험체와 현장에 시공된 록볼트의 결함비율이 증가함에 따라 증가하는 것으로 나타났다. 본 연구의 결과는 해머 타격방법이 현장에서 록볼트 건전도 평가에 유용한 방법이 될 수 있음을 보여 준다.

공산오차를 적용한 환경영향평가 대상지역 설정 기준에 관한 연구 - 곡사화기 사격장 조성사업을 중심으로 - ('Probable Errors' as an EIA Method to Define Project Impact Area - Focusing on the Preparation of 'Howitzer' Fire Training Site -)

  • 강재구;최준규;조공장;주용준;한명수
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.495-502
    • /
    • 2007
  • In Korea, military authorities have neglected to consider impacts of military projects on local communities and natural environment. Moreover, local communities have had difficulties in dealing with the Ministry of National Defense (MND), which was stubborn enough not to implement environmental assessment on their projects. In this situation, recent case, "EIA of Baekgol Division's Howitzer Fire Training Site" in the Supreme Court-in which judges upheld the Higher Court's decision that the division violated the Environmental Impact Assessment law by ignoring to implement EIA-reveals that military projects can no longer forgo environmental assessment. The decision has serious ramifications on the future of Environmental Impact Assessment in military-led projects. This paper examines the proper scope of EIA in military-led projects and, more specifically, fire training site and searches for how to improve it through 'probable error,' a military training method that is applied to real 'howitzer' fire training. Probable error of the artillery field manual is nothing more than an error that exceeded as often as it is not exceeded and its scientific method was demonstrated through real fire tests in the US. Army. If it is applied to improve assessment methods about the proper scope of EIA in military 'howitzer' fire training site, 'probable error' will improve effect prediction, mitigation and reliability.

도로교의 간이 내하력평가를 위한 충격계수의 산출 (Impact Factor for Safety Evaluation of Highway Bridges)

  • 정철헌;김영진;박칠림
    • 콘크리트학회지
    • /
    • 제7권1호
    • /
    • pp.109-116
    • /
    • 1995
  • 본 연구에서는 단순 지지된 일반도로교의 통행차량에 의해서 발생하는 충격계수에 대해서 연구를 수행하였다. 최근에 화서 충격계수는 이론 및 실험적인 연구가 수행됨으로써 상당한 관심이 집중되고 있다. 현행, 국내 도로교 시방서에서 사용하는 충격계수는 지간길이에 따라 감소하는 식으로서 규정되어 있으며, 최대 30%이하로 제한하고 있다. 그러나, 현장실험결과에 의하여 동적하중효과는 대부분 현행 규정보다 낮게 나타나고 있으며, 시방서에서와 같이 지간길이에 다라 일정한 경향을 보여주지 못하고, 포장상태를 포함하는 노면조도에 의해서 큰 영향을 받는 것으로 나타났다. 따라서, 본 연구에서는 현장 실험결과를 바탕으로 노면조도의 상태를 3등급으로 분류하여 도로교의 간이 내하력평가시 사용할 수 있도록 각 등급에 해당하는 충격계수를 결정하였다. 끝으로, 본 연구의 결과는 향후 현존 교량의 내하력평가시 유용한 자료로 사용될 수 있을 것으로 사료된다.

Relation between Multiple Markers of Work-Related Fatigue

  • Volker, Ina;Kirchner, Christine;Bock, Otmar L.
    • Safety and Health at Work
    • /
    • 제7권2호
    • /
    • pp.124-129
    • /
    • 2016
  • Background: Work-related fatigue has a strong impact on performance and safety but so far, no agreed upon method exists to detect and quantify it. It has been suggested that work-related fatigue cannot be quantified with just one test alone, possibly because fatigue is not a uniform construct. The purpose of this study is therefore to measure work-related fatigue with multiple tests and then to determine the underlying factorial structure. Methods: Twenty-eight employees (mean: 36.11; standard deviation 13.17) participated in five common fatigue tests, namely, posturography, heart rate variability, distributed attention, simple reaction time, and subjective fatigue before and after work. To evaluate changes from morning to afternoon, t tests were conducted. For further data analysis, the differences between afternoon and morning scores for each outcome measure and participant (${\Delta}$ scores) were submitted to factor analysis with varimax rotation and each factor with the highest-loading outcome measure was selected. The ${\Delta}$ scores from tests with single and multiple outcome measures were submitted for a further factor analysis with varimax rotation. Results: The statistical analysis of the multiple tests determine a factorial structure with three factors: The first factor is best represented by center of pressure (COP) path length, COP confidence area, and simple reaction time. The second factor is associated with root mean square of successive difference and useful field of view (UFOV). The third factor is represented by the single ${\Delta}$ score of subjective fatigue. Conclusion: Work-related fatigue is a multidimensional phenomenon that should be assessed by multiple tests. Based on data structure and practicability, we recommend carrying out further studies to assess work-related fatigue with manual reaction time and UFOV Subtest 2.

지중 매설관의 세정을 위한 카본 다이옥사이드 펠릿의 현장 적용성 검토 (Field Applications of Carbon Dioxide Pellet for Underground Pipe Cleaning)

  • 최재순
    • 한국지반신소재학회논문집
    • /
    • 제16권4호
    • /
    • pp.75-82
    • /
    • 2017
  • 본 연구에서는 지중 매설관의 새로운 세정공법으로 개발된 카본 다이옥사이드 펠릿을 이용한 분사 세정공법의 현장 적용성을 검토하였다. 이를 위해 우선적으로 미국 철강도금도장위원회에서 제안하고 있는 관 세정 전후에 관한 시방내용들을 조사하고 이를 기초로 하여 본 공법의 금속표면 처리기준을 선정하였으며 임의의 녹이 슨 관을 대상으로 카본 다이옥사이드 분사세정의 현장시험을 수행하고 세정도가 선정기준에 부합되는지를 검토하였다. 또한, 모양을 달리한 2가지의 노즐시스템이 적용되어 분사압에 따른 세정효과가 분석되었으며 각 노즐시스템에 대해서 최종 충격량 계측시험을 수행하여 공기압 대비 최종 분사압의 압력손실을 검토하였다. 연구결과, 제안된 공법은 미국철강도금위원회에서 규정하고 있는 수준을 상회하는 세정효과가 있음을 확인하였으며 노즐 비교실험으로부터 세정효과가 우수한 노즐도 선정되었다. 이로부터 카본 다이옥사이드 펠릿을 이용한 관 세정공은 완전탈락수준에 이르는 관 세정효과를 기대할 수 있을 뿐만 아니라 냉각제로의 이용 등에 국한되는 이산화탄소 재활용 부분의 활성화에 크게 기여할 수 있을 것으로 판단된다.

콘크리트 지반구조물의 비파괴검사를 위한 충격반향-표면파 병행기법 : II. 실험적 연구 (IE-SASW Method for Nondestructive Testing of Geotechnical Concrete Structure : II. Experimental Studies)

  • 김동수;서원석;이광명
    • 한국지반공학회논문집
    • /
    • 제18권4호
    • /
    • pp.271-283
    • /
    • 2002
  • 콘크리트 구조물의 건전성 평가에 사용되는 충격반향기법에서는 콘크리트의 P파 속도가 부재의 두께 및 결함의 위치를 찾는데 있어서 매우 중요한 요소이다. 본 논문의 동반논문인 수치해석편에서 표면파기법을 이용하여 콘크리트 부재의 P파 속도를 신뢰성 있게 추정함을 알 수 있었다. 수치해석 연구에 이어서 본 논문에서는 공극, 불량콘크리트 등의 결함이 내재된 콘크리트 모형 슬래브를 제작하여 제안된 충격반향-표면파 병행기법의 실제 구조물에 대한 적용성 연구를 수행하였다. 실험결과, 표면파기법으로부터 구한 부재의 P파 속도는 두께를 알고 있는 부분에서 충격반향기법으로부터 구한 P파 속도와 거의 일치하였으며, 표면파기법으로부터 구한 P파 속도를 적용하여 충격반향기법을 수행한 결과, 여러 결함의 위치를 신뢰성있게 찾아낼 수 있었다. 또한, 실제 지중에 매설되는 관 형태의 지중 구조물과 지중에 매설된 개착식 터널에서 제안된 비파괴검사기법을 수행한 결과, 구조물의 두께를 신뢰성 있게 구하여 실제 지반구조물에서의 현장 적용성을 확인하였다.

Advanced Field Weakening Control for Maximum Output Power Operation of Induction Motor in a Limited Environment

  • Seo, Yong-Joo;Go, Hee-Young;Kim, Jang-Mok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.217-218
    • /
    • 2012
  • A load motor used for warship or submarine is with limited volume and weight, also specific environmental tests like impact, vibration, noise, temperature and EMC/EMI have to be satisfied. Induction motors, synchronous motors, BLDC motor and etc, are used depending on the purpose of using military equipment. Induction Motors are used for a number of military equipment more commonly due to the robust structure and simple maintenance. Domestic and foreign warships have a wide range of voltages as the DC voltage sources with battery are mainly used for them. The ${\Delta}-connection$ operation of the induction motor is required to make the maximum power in a low voltage level. But the elements' temperature of the inverter increases due to high input current when it is in the ${\Delta}-connection$ operation. Therefore, the induction motor must be driven with the Y-connection. The lack of voltage needs to be with the field weakening control. This paper suggests the optimum field weakening control algorithm to drive the induction motor with maximum power in a limited thermal and DC voltage condition.

  • PDF

고무방진매트가 적용된 플로팅궤도시스템의 거동분석을 위한 실험적 연구 (Experimental Study on the Evaluation of Behavior for Floating Track System Using a Resilient Rubber Mat)

  • 이시용;정인철;최정열;박용걸
    • 한국철도학회논문집
    • /
    • 제17권4호
    • /
    • pp.281-288
    • /
    • 2014
  • 본 연구는 고가정거장 구간에 부설된 고무방진매트 플로팅궤도시스템의 방진성능 및 적용효과를 실험적으로 입증하고자 고무방진매트가 적용되지 않은 개소와 비교 측정을 수행하였다. 또한 고무방진매트 플로팅 궤도시스템의 측정 궤도지지강성 및 궤도충격계수를 산출하고 이론 및 설계치와 비교하여 현재 시공된 고무방진매트 플로팅궤도시스템에 대한 궤도상태의 건전성 및 궤도 충격의 수준을 평가하였다.