• Title/Summary/Keyword: Field aging

Search Result 554, Processing Time 0.025 seconds

A Study on the case of residential facilities for the leisure of Active aging (Active aging의 여가생활을 고려한 유료노인주거시설의 부대시설에 관한 연구)

  • Kim, So-Yeon;Lee, Hyun-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.215-218
    • /
    • 2008
  • Recently most Elderly in 2050 Our country is becoming an "aging society" at a speed far more rapidly than expected, the interests of silver industry is also increasing. Many researches about the elderly are already presented in academic world, especially in the field of housing environment, the housing plans on the basis of physical, social and emotional characteristics for the elderly are proposed. As the number of elderly participating in economy activities is getting higher, we selected on "active aging" generation which given a definition by OECD. In this research, we examine the present situation related to the needs for leisure time with the elderly who want to have their comfortable life. This purpose of this study is to survey the residential facilities for elderly, and how that facilities are reflected to their needs for the leisure. This study will indicate to the direction of plans in elderly housing.

  • PDF

An On-Chip Test Clock Control Scheme for Circuit Aging Monitoring

  • Yi, Hyunbean
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.71-78
    • /
    • 2013
  • In highly reliable and durable systems, failures due to aging might result in catastrophes. Aging monitoring techniques to prevent catastrophes by predicting such a failure are required. Aging can be monitored by performing a delay test at faster clocks than functional clock in field and checking the current delay state from the test clock frequencies at which the delay test is passed or failed. In this paper, we focus on test clock control scheme for a system-on-chip (SoC) with multiple clock domains. We describe limitations of existing at-speed test clock control methods and present an on-chip faster-than-at-speed test clock control scheme for intra/inter-clock domain test. Experimental results show our simulation results and area analysis. With a simple control scheme, with low area overhead, and without any modification of scan architecture, the proposed method enables faster-than-at-speed test of SoCs with multiple clock domains.

Evaluation Technology of Electrical and reliableility Characteristics for Outdoor Polymer Insulator Materials (폴리머 절연물 소재의 전기적 밀 복합열화 특성평가 기술)

  • Ahn, Myeong-Sang;Park, Hoy-Yul;Na, Moon-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1343-1344
    • /
    • 2006
  • There have been numerous accelerated aging laboratory tests for evaluating suitability of polymeric materials and devices. Aging test for materials and its full scale device has been conducted. Service experience plays a key role in the utility section of composite insulators. A meaningful and reliable accelerated aging test is needed for evaluating composite insulator. During the service these insulators are subjected to aging stress such as humidity, pollution, and electrical field, and erosion and tracking of the weathershed occurs. This paper presents the criteria of reliability evaluation and evaluation facilities for 22.9 kV suspension composite insulator. We adopt the criteria of reliability evaluation consist of two test methods. One is CEA tracking wheel test for examining the tracking and erosion performance of composite insulator. The other is multi-stress aging test for examining effects of environmental factors such as UV, temperature, humidity, etc on composite insulator.

  • PDF

Multi-Stress Aging Test Technology for Suspension Polymer Insulator (폴리머 현수애자의 복합가속열화 평가기술)

  • Park, Hoy-Yul;Kang, Dong-Pil;Kim, Ik-Soo;Shin, Young-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.481-484
    • /
    • 2003
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators have significant advantages over porcelain and glass insulators. With the gradual improvement of their design and material, their reliability has also increased. It is however difficult to establish how they will perform after several years of service. Aging of the insulator weathershed may lead to damages such as excessive chalking and crazing, erosion and tracking which affect the insulator performance. In service insulator are subjected to aging stresses such as humidity, pollution and electrical field which act singly or in combination. There have been numerous accelerated laboratory tests developed with the intention of evaluating suitability of polymeric materials. Some of these are strictly material tests, where as, others evaluate full scale devices. Service experience plays a key role in the utility selection of polymer insulator, but is time consuming, and may not always be available. Hence there is a need for a meaningful and reliable accelerated aging test for polymer insulator. This paper describes multi-stress aging test for reliability of polymer insulator This paper presents the rule of multi-stress aging test and test chamber for polymer insulator in korea electrotechnology research institute.

  • PDF

Effect of Surface Morphology and Adhesion Force on the Field Emisson Properties of Carbon Nanotube Based Cathode (탄소나노튜브 캐소드의 전계방출 특성에 대한 표면 형상과 부착력의 영향)

  • Jung, Hyuk;Cho, You-Suk;Kang, Young-Jin;Kim, Do-Jin
    • Korean Journal of Materials Research
    • /
    • v.18 no.5
    • /
    • pp.277-282
    • /
    • 2008
  • The effects of the field emission property in relation to the surface morphology and adhesion force were investigated. The single-wall-nanotube-based cathode was obtained by use of an in-situ arc discharge synthesis method, a screen-printing method and a spray method. The morphologies of the formed emitter layers were very different. The emission stability and uniformity were dramatically improved by employing an in-situ arc discharge synthesis method. In this study, it was confirmed that the current stability and uniformity of the field emission of the cathode depend on the surface morphology and adhesion force of the emitters. The current stability of the field emission device was also studied through an electrical aging process by varying the current and electric field.

High resolution 5" full color field emission displays with new aging technique

  • Kim, J.M.;Hong, J.P.;Park, N.S.;Ryu, Y.S.;Jung, J.E.;Hong S.S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.23-23
    • /
    • 1998
  • High resolution field emission dispplay(FED) devices of 5 inch diagonal in size are fully developped for the applications of near-future flat ppanel dispplays. Under the unique gate-switching drive scheme electron trajectory pprofiles are simulated and tested by considering leakage effects of each ppixel. Uniquely-pprinted sppacer with high asppect ratio are fabricated on real ITO glass for high vacuum ppackaging. In addition new gas aging scheme of stabilizing field emitting array are extensively investigated during the sealing and exhausting pprocess in order to pprevent oxidation effects on the micro tipp. Finally fulll color images of 64 gray scale will be demonstrated.

  • PDF

Acoustic Properties of Electrostrictive Buzzer Using PZN-BT-PT Ceramics (PZN-BT-PT 세라믹스를 이용한 전왜 BUZZER의 음향 특성)

  • 유준현;김현재;박창엽
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.1
    • /
    • pp.50-55
    • /
    • 1992
  • Piezoelectric Buzzer which has been generally used requires about 30kV/cm poling process and has the aging effects. In this study, 0.85 PZN - 0.10 BT - 0.05 PT system ceramics with additives of 0 - 2 wt% YS12TOS13T were fabricated and investigated on electromechanical coupling coefficient(kS1pT), electric field induced charge coefficient(dS131T), and sound level. As the results, in the 0.4 wt% YS12TOS13T added composition ceramics compared with the basic, kS1pT was increased from 0.355 to 0.39 and induced piezoelectric d constant increased from 204 to 220 x 10S0-12T (C/N) and sound level of electrostrictive Buzzer has the highest value of 71.5 dB under 8kV/cm bias electric field.

  • PDF

The Characteristics of RVM by Accelerated Aging in Insulating Materials of the Transformer (경년 열화에 따른 변압기 절연물의 회복전압 특성)

  • Kang, Seok-Young;Han, Sang-Ok;Kim, Jae-Hoon;Kim, Ju-Han;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.73-75
    • /
    • 2005
  • In present measurement of moisture contents is used as one of method for estimating degradation of transformer. Most of people use Karl-Fischer titration method for detection moisture contents but this measurement is inconvenient method because we must analyze transformer oil-paper after dismounting transformer and sampling in field. Therefore we don't directly investigate them in field. In this paper we will introduce Recovery Voltage Method(RVM) that is new method for estimating measurement in field though dismounting facility. For measure of moisture contents using RVM in accordance with accelerated thermal aging we have made experimental test cell and aged at a temperature up to 140$^{\circ}C$ for 300 hours. And we have been measured at intervals of 100 hours using RVM 5462 made in fetter company.

  • PDF

The Effect of Magnetic Field Direction on the EEG and PPG Obtained from Pulsed Magnetic Stimulus at Acupoint PC9

  • Kim, Sun-Wook;Lee, Jin-Yong;Lee, Hyun-Sook
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.259-262
    • /
    • 2011
  • Compared to acupuncture, the pulsed magnetic field (PMF) stimulus is a useful tool for treatment of many physical conditions and health maintenance due to its advantages as a noninvasive and nontoxic medical treatment. The purpose of this study was to investigate the effect of PMF stimulus direction at PC9 on the alpha activity of electroencephalogram (EEG) and vascular aging calculated from photoplethysmograph (PPG). It can be concluded that the direction of PMF stimulus affects the increase of alpha activity of EEG and PPG, indicating the vascular stiffness and the sclerosis level of blood vessels weakly relevant to the direction of PMF stimulus.

Characteristics of Undrained Cyclic Shear Behavior for the Nak-dong River Sand Due to the Aging Effect (Aging 효과에 따른 낙동강 모래의 비배수 반복전단거동 특성)

  • Kim Dae-Man;Kim Young-Su;Jung Sung-Gwan;Seo In-Shik
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.8
    • /
    • pp.13-26
    • /
    • 2005
  • It was known that the aging effect of sands is insignificant in comparison with clays, and hence the study on this effect had seldom been performed prior to the early 1980s. However, field tests for this effect have been actively carried out since it was investigated that penetration resistance of reformed sands increased with the lapse of time. Recently, the aging effect of sands has also been examined in laboratory testings. In this study, undrained static triaxial tests were performed to evaluate the effect on the Nak-dong River sands, with different .elative densities $(D_r)$, consolidation stress ratios $(K_c)$, and consolidation times. As a result of the tests, it was proved that the undrained cyclic shear strength $(R_f)$ increased with the aged time on the sands. The in situ range of Rf on the sands, which is applicable to the magnitude of earthquake in the Nak-dong River area, was proposed by using the test results.