• 제목/요약/키워드: Field Slope Length

검색결과 107건 처리시간 0.031초

경사지 경지정리지구의 등고선 구획 최적설계 (Optimal Design of Contour-Lined Plots for Land Consolidation Planning in Sloping Areas)

  • 강민구;박승우;강문성;김상민
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.83-95
    • /
    • 2003
  • In this study, a new concept in a paddy consolidation project is introduced in that curved parallel terracing with contour-lined layout is adopted in sloping areas instead of conventional rectangular terracing. The contoured layout reduces earth-moving considerably compared to rectangular methods in consolidation projects. The objective of the paper is to develop a combinatorial optimization model using the network theory for the design of contour-lined plots which minimizes the volume of earth moving. The results showed that as the length of short side of plot is longer or the land slope is steeper, the volume of earth moving for land leveling increases. The developed optimization model is applied for three consolidated districts and the resulting optimal earth moving is compared with the volume of earth from the conventional method. The shorter is the minimum length of short side of a polt with increases the number of plots, the less is the volume of earth. As the minimum length of short side is 20 m for efficient field works by farm machinery, the volume of earth moving of optimal plot is less by 21.0∼27.1 % than that of the conventional consolidated plots.

고상 결정화로 제작한 다결성 실리콘 박막 트랜지스터에서의 열화특성 분석 (The Analysis of Degradation Characteristics in Poly-Silicon Thin film Transistor Formed by Solid Phase Crystallization)

  • 정은식;이용재
    • 한국전기전자재료학회논문지
    • /
    • 제16권1호
    • /
    • pp.26-32
    • /
    • 2003
  • Then-channel poly-Si thin-film transistors (poly-Si TFT's) formed by solid phase crystallization (SPC) method on glass were measured to obtain the electrical parameters such as of I-V characteristics, mobility, leakage current, threshold voltage, and subthreshold slope. Then, devices were analyzed to obtain the reliability and appliability on TFT-LCD with large-size and high density. In n-channel poly-Si TFT with 5$\mu\textrm{m}$/2$\mu\textrm{m}$, 8$\mu\textrm{m}$, 30$\mu\textrm{m}$ devices of channel width/length, the field effect mobilities are 111, 116, 125 $\textrm{cm}^2$/V-s and leakage currents are 0.6, 0.1, and 0.02 pA/$\mu\textrm{m}$, respectively. Low threshold voltage and subthreshold slope, and good ON-OFF ratio are shown, as well. Thus. the poly-Si TFT's used by SPC are expected to be applied on TFT-LCD with large-size and high density, which can integrate the display panel and peripheral circuit on a targe glass substrate.

Magnetic Actuator for a Capsule Endoscope Navigation System

  • Chiba, Atsushi;Sendoh, Masahiko;Ishiyama, Kazushi;Arai, Ken Ichi;Kawano, Hironao;Uchiyama, Akio;Takizawa, Hironobu
    • Journal of Magnetics
    • /
    • 제12권2호
    • /
    • pp.89-92
    • /
    • 2007
  • The authors propose a magnetic actuator for use as a navigation system for capsule endoscopes. The actuator is composed of a capsule dummy, a permanent magnet inside the capsule, and an external spiral structure. The device rotates and propels wirelessly when exposed to an external rotational magnetic field. In this study we measured the effect of the spiral shape on the velocity and thrust force properties. According to our experimental results, the actuator obtained a maximum velocity and thrust force when the spiral angle was set at 45 degrees, the number of spirals was set at 4, and the spiral-height was set at 1-mmf. We also conducted a motion test in the large intestine of a pig placed on a 30 degrees slope. The actuator passed through a 700 mm length of the intestine in about 300 s. The device also managed to travel up and down the 30 degrees slope with no difficulty whatsoever. Our results demonstrate the great potential of this actuator for use as a navigation system for capsule endoscopes.

콩재배 포장 라이시메타를 이용한 alachlor, ethalfluralin, ethoprophos 및 pendimethalin의 유출량 평가 (Runoff and Erosion of Alachlor, Ethalfluralin, Ethoprophos and Pendimethalin from Soybean Field Lysimeter)

  • 김찬섭;이희동;오병렬;이영득
    • 한국환경농학회지
    • /
    • 제25권4호
    • /
    • pp.297-305
    • /
    • 2006
  • 강우에 의한 경사지 토양으로부터의 농약 유출양상을 파악하고 그에 대한 농약의 특성, 환경적 요인 및 영농방법 등의 영향 정도를 평가하기 위하여 콩 재배 경사지 포장에 설치된 포장 lysimeter에서의 경사도와 경사장 및 작물의 재배 유무에 따른 농약의 표면유출 양상을 파악하고자 하였다. Lysimeter 포장유출실험 결과 경사도 및 경사장별 나지구의 유실량은 alachlor $0.1{\sim}0.6%$, ethalfluralin $1.1{\sim}4.5%$, ethoprophos 0.03% 및 pendimethalin $8{\sim}31%$ 수준이었으며, 인공강우실험의 유실율에 비하여 $1/3{\sim}2.5$배 수준으로 나타났다. 콩재배구의 유실율은 나지구의 유실율에 비하여 평균적으로 $21{\sim}75%$ 감소된 것으로 나타났다. 경사조건의 영향을 살펴보면 유출수의 경우에는 그 차이가 크지 않았으나 유실토양에 의한 유실율은 최대 $4{\sim}12$배까지 증가하는 것으로 나타났다. 한편 유출수 중 농약성분의 최고농도는 콩재배구 및 나지구 각각 ethalfluralin $1.1{\sim}11.4{\mu}gL^{-1}$$0.9{\sim}16{\mu}gL^{-1}$, pendimethalin $7{\sim}42{\mu}gL^{-1}$$6{\sim}66{\mu}gL^{-1}$ 수준으로 작물재배 유무에 따른 유출수 중 농도의 차이는 크지 않은 것으로 나타났다. 따라서 농약의 살포지역 외부로의 유출은 기본적으로는 강우와 경사조건에 따른 물 유출량과 토양의 유실량에 의하여 결정되고 작물의 피복정도에 따라 감소하는 것으로 결론지을 수 있을 것이다.

콤바인의 자동제어에 관한 연구(I) -자탈형(自脱型) 콤바인의 주행방향제어(走行方向制御)- (Automatic Control of the Comnbine(I) -Automatic guidance control of the head-feed combine-)

  • 정창주;김성옥;김수성
    • Journal of Biosystems Engineering
    • /
    • 제13권2호
    • /
    • pp.38-45
    • /
    • 1988
  • This study was intended to develop the system automatically controlling travel direction of combine by means of sensing paddy rows. The control system was composed of three detecting levers having different length, micro-switch, microcomputer and electro-hydraulic control system. Sensor and control system developed was tested to estimate optimum design values and its actual performance as installed in combine. The computer simulation and performance test at simulated and actual field were conducted to test for possibility of practical use. The results of the study arc summarized. as follows: 1. The travel traces of combine hiving the conventional sensor with 2 levers and the new sensor detecting the slope of paddy rows were compared through computer simulation. Turning frequency of combine having new sensor was fewer than that of conventional sensor, but the rate of turning for the combine with new sensor was much greater than that of conventional sensor. 2. As sensor was established behind the tip of divider, the sensor itself well followed paddy rows but the tip of divider did not, resulting in divider being deviated from paddy rows. It was analyzed that the sensor should be attached closer to the tip of divider to have a better performance of the control system. 3. The greater the length of sensor lever for given location of sensor attachment and combine forward speed, the higher sensitivity of turning in control system. Moreover, increasing combine speed resulted in a worse performance of control system following paddy rows. Consequently, it was necessary that an optimum length of sensor attachment and for the range of combine operational speed. 4. Field test of combine installed with the sensor and electro-hydraulic system developed in this study showed that it may be operated smoothly and well behaved to paddy rows to 4th gear of combine speed which was 59cm/s. Consequently. it was concluded that the combine with the guidance control system developed in this study may be successfully used for paddy combining.

  • PDF

제주도 공공 농업용 지하수의 효율적 누수량 산정 연구 (Efficient Leakage Estimation of Public Agriculture Groundwater in Jeju Island)

  • 김민철;박원배;강봉래;김지명
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제25권3호
    • /
    • pp.1-11
    • /
    • 2020
  • In this study, leakage ratios of Jeju Island's public agricultural groundwater were calculated by utilizing field measurements of groundwater level and surface reservoir water level. The average leakage ratios were 75.6% at groundwater well A and 57.5% at well B, with the ratio inversely proportional to agricultural water usage. The level of agricultural reservoirs varied at constant intervals at night, and the amount of water leakage associated with the variation was estimated as 0.1 - 16.3 ㎥/h. The leakage ratio was also influenced by pipeline length, average slope, and number of farmhouses. Currently, the estimation of agricultural water leakage on Jeju Island is based upon field inspection which is very labor- and cost intensive. The leakage ratio estimated by monitoring the reservoirs associated with the well A and B were 73.3 and 54.7%, respectively, consistent with the values obtained by field measurements.

부착식 앵커의 인발 특성에 관한 실험적 연구 (Experimental Study on Pull Out Characteristics of Adhesive Anchor)

  • 유성원;정상화;곽기석;이주형
    • 대한토목학회논문집
    • /
    • 제26권3A호
    • /
    • pp.555-563
    • /
    • 2006
  • 최근 많은 교량들이 점증하는 교통량에 의해 상부슬래브 폭이 부족해지거나 침식으로 인해 하부구조가 구조적으로 취약해지는 경향이 있다. 이 경우 상부슬래브나 교각을 확장하여 보강하는 것이 경제적이기 때문에 실험 자료와 현장의 시공경험 등을 통해 적절한 교량의 확장방안을 확립할 필요가 있다. 그렇지만, 부착식 앵커를 사용하여 교량의 하부구조를 보수 보강하는 경우 신 구 콘크리트의 일체성 확보와 관련된 기존 실험자료는 매우 부족한 실정이며, 이에 따라 부착식 앵커를 사용하여 구조적인 일체성을 확보하기 위한 실험적인 연구가 매우 시급하다고 할 수 있다. 이와 관련하여 본 논문에서는 부착식 앵커를 사용할 경우의 인발 및 전단 특성을 실험을 통해 밝히고자 하였다. 이를 위해 부착길이, 앵커직경 및 앵커경사를 포함한 다양한 실험변수를 가진 시편을 제작하여 인발 및 전단실험을 수행하였다. 실험결과 부착길이가 길어지고 앵커직경이 커질수록 부착력은 증가하고 부착강도는 감소하였다. 또한, 앵커경사가 커질수록 부착력 및 부착강도가 증가하지만 경사가 $5^{\circ}$ 이상인 경우 경사에 의한 효율이 감소하는 것을 알 수 있었다. 전단실험을 통해서는 앵커직경이 D19 이상을 사용하는 것이 적절할 것으로 판단되었다. 결론적으로, 향후 모델실험을 포함한 관련 자료의 축적이 이루어지는 경우 본 연구에서 수행한 실험 자료와 함께 부착식 앵커를 사용하여 보강된 신 구 콘크리트의 일체성을 확보하는데 많은 기여를 할 수 있을 것으로 기대된다.

경사지에 있어서의 상수의 근계에 관한 연구 (Studies on the Root System of Mulberry Tree at Slope. Land)

  • 김문협;임수호
    • 한국잠사곤충학회지
    • /
    • 제8권
    • /
    • pp.1-9
    • /
    • 1968
  • 폭 170cm의 간이계단식 경사지에 식재된 상수의 근계를 조사한 결과는 다음과 같다. 1. 2본소식한 경우의 1소당 총근중은 2.4-2.8kg, 직경 1mm이하의 세근을 제외한 총근장은 177-255m이며 그 중에서 총근중은 직경 10mm이상의 것이 가장 많고 1-5mm의 것이 그 다음이며 1mm이하의 것과 5-10mm의 것은 가장 적다. 총근장은 이와 반대로 1-5mm의 것이 가장 길고 10mm이상의 것은 극히 짧다. 2. 수직위치에 따르는 분포는 그 중량이나 길이가 다 같이 지표에서 20cm까지의 토층에 가장 많고 20-40cm의 토층이 그 다음이며 이 부위에 전체의 90% 이상이 분포해 있다. 3. 좌우위치에 따라서 보면 상수를 중심으로 하여 좌우 각각 30cm 이내의 부위에 대부분의 뿌리가 분포해 있다. 4. 계단의 전후위치별로 보면 계단전단에서 35-70cm의 부위와 70-80cm의 부위에 가장 많이 분포해 있고 이보다 멀어지는 데 파라서 적어지며 계단의 후면보다는 전면이 뿌리의 분포가 약간 많다. 5. 각 품종간에 있어서의 근계의 분포상태는 지적할 만한 차가 없는 것 같다.

  • PDF

Near-elliptic Core Triangular-lattice and Square-lattice PCFs: A Comparison of Birefringence, Cut-off and GVD Characteristics Towards Fiber Device Application

  • Maji, Partha Sona;Chaudhuri, Partha Roy
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.207-216
    • /
    • 2014
  • In this work, we report detailed numerical analysis of the near-elliptic core index-guiding triangular-lattice and square-lattice photonic crystal fiber (PCFs); where we numerically characterize the birefringence, single mode, cut-off behavior and group velocity dispersion and effective area properties. By varying geometry and examining the modal field profile we find that for the same relative values of $d/{\Lambda}$, triangular-lattice PCFs show higher birefringence whereas the square-lattice PCFs show a wider range of single-mode operation. Square-lattice PCF was found to be endlessly single-mode for higher air-filling fraction ($d/{\Lambda}$). Dispersion comparison between the two structures reveal that we need smaller lengths of triangular-lattice PCF for dispersion compensation whereas PCFs with square-lattice with nearer relative dispersion slope (RDS) can better compensate the broadband dispersion. Square-lattice PCFs show zero dispersion wavelength (ZDW) red-shifted, making it preferable for mid-IR supercontinuum generation (SCG) with highly non-linear chalcogenide material. Square-lattice PCFs show higher dispersion slope that leads to compression of the broadband, thus accumulating more power in the pulse. On the other hand, triangular-lattice PCF with flat dispersion profile can generate broader SCG. Square-lattice PCF with low Group Velocity Dispersion (GVD) at the anomalous dispersion corresponds to higher dispersion length ($L_D$) and higher degree of solitonic interaction. The effective area of square-lattice PCF is always greater than its triangular-lattice counterpart making it better suited for high power applications. We have also performed a comparison of the dispersion properties of between the symmetric-core and asymmetric-core triangular-lattice PCF. While we need smaller length of symmetric-core PCF for dispersion compensation, broadband dispersion compensation can be performed with asymmetric-core PCF. Mid-Infrared (IR) SCG can be better performed with asymmetric core PCF with compressed and high power pulse, while wider range of SCG can be performed with symmetric core PCF. Thus, this study will be extremely useful for designing/realizing fiber towards a custom application around these characteristics.

골부초와 자갈대에 의한 고랭지 감자재배지 토양보전 효과 (Effects of Minimum Furrow Mulching with Weed Straw and Gravel Furrow Barrier on Soil Conservation at Potato Field in Gangwon Highland)

  • 박철수;정영상;주진호;이원정;양재의
    • 한국환경농학회지
    • /
    • 제24권1호
    • /
    • pp.29-33
    • /
    • 2005
  • 강원도 고령지 지역의 밭은 경사지에 발달한 곳이 많아서 강우에 의한 유거수와 토양의 유실이 많이 일어나게 된다. 일부 지역에서는 석비레를 이용하여 농업을 하고 있어 강우침식을 쉽게 받을 수 있다. 이러한 농경지 밭에 쉽게 적용하여 토양유실을 저감시킬 수 있도록 하기 위해 농경지 인근에서 쉽게 구할 수 있는 잡초와 토양침식 후 표면에 남근 자갈을 이용하여 골에 일정 간격으로 두어 그 효과를 살펴보았다. 토양 유실량은 식양토이면서 13%의 경사를 가진 포장에서는 사경과 등고선 경작만으로도 토양 유실량을 현저히 줄일 수 있는 젓으로 나타났고, 경사가 23%인 석비레 사양토 포장에서는 토양 유실이 심하게 발생하는 것으로 나타났다. 부초와 자갈을 최소로 이용하는 골최소부초와 골자갈대를 시험구에 처리함으로써 처리하지 않은 구에 비해 횡계와 용산 포장에서 45% 이상의 토양 유실 저감 효과와 유거수 발생 또한 저감시킬 수 있는 것으로 나타났으나, 사양토인 석비레 성토 지역의 경우는 토양 유실량이 보전처리구에서 61 Mg/ha 이상이 발생하여 골최소부초와 골자갈대를 3 m 간격으로 처리 하여서는 그 효과를 허용 토양 유실량인 11 Mg/ha 이하로 낮출 수 없는 것으로 평가되어 단일한 방법으로는 토양보전에 부족한 것으로 평가되었다.