• Title/Summary/Keyword: Field Measurement

Search Result 5,067, Processing Time 0.033 seconds

So, You Need Reliable Magnetic Measurements You Can Use With Confidence? How the Magnetic Measurement Capabilities at NPL Can Help

  • Hall, Michael;Harmon, Stuart;Thomas, Owen
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.339-341
    • /
    • 2013
  • The magnetic field standards, facilities and capabilities available at NPL for the calibration of magnetometers and gradiometers and the measurement of the magnetic properties of materials will be introduced. The details of the low magnetic field facility will be explained and the capabilities this facility enables for the characterisation and calibration of ultra-sensitive room temperature magnetic sensors will be presented. Building on core material capabilities that are compliant with the IEC 60404 series of written standards, the example of a standard permeameter that has been modified for the measurement of strips for real world conditions is discussed. This was incorporated into a stress machine to measure the DC properties of the soft magnetic materials used by the partners of a collaborative industry led R&D project at stress levels of up to 700 MPa. The results for three materials are presented and the changes in the properties with applied stress compared to establish which material exhibits favourable properties.

Fast Measurement of Eyebox and Field of View (FOV) of Virtual and Augmented Reality Devices Using the Ray Trajectories Extending from Positions on Virtual Image

  • Hong, Hyungki
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.336-344
    • /
    • 2020
  • Exact optical characterization of virtual and augmented reality devices using conventional luminance measuring methods is a time-consuming process. A new measurement method is proposed to estimate in a relatively short time the boundary of ray trajectories emitting from a specific position on a virtual images. It is assumed that the virtual image can be modeled to be formed in front of one's eyes and seen through some optical aperture (field stop) that limits the field of view. Circular and rectangular shaped virtual images were investigated. From the estimated ray boundary, optical characteristics, such as the viewing direction and three dimensional range inside which a eye can observe the specified positions of the virtual image, were derived. The proposed method can provide useful data for avoiding the unnecessary measurements required for the previously reported method. Therefore, this method can be complementary to the previously reported method for reducing the whole measurement time of optical characteristics.

Measurement of Spectral Loss and Cut-off Wavelength of Single Mode Opticla Fiber by Variable Wavelength (파장변화에 따른 단 모드 광섬유의 스펙트랄 로스 및 차단파장 측정)

  • Hong, Bong Sik;Han, Byoung Sung;Koo, Kyoung Wan
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.2
    • /
    • pp.264-268
    • /
    • 1986
  • A thchnique has been studied for the measurement of the spectral loss and the cut-off wave length, at which the first high-order mode disappears. The near-field patterns of a fiber which is excited by a variable wavelength source are used for the measurement of cut-off wavelength. Because of the absorptive phenomenon of OH- molecular vibration, spectral loss of a single mode optical fiber sample is 5.6dB/km at 1380 nm wavelength and 1dB/km at 1240 nm wavelength. From the near field intensity patterns and the mode field diameter graph for the half power width, the cut-off wavelength of the fiber is measured to be 1120 nm.

  • PDF

Review on Current Status of Use and Measurement Condition of Heart Rate Variability in Clinical Study of Korean Medicine (한의학 임상연구에서의 심박변이도 검사 활용현황과 측정조건에 대한 고찰)

  • Kim, Sang-Ho
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.127-137
    • /
    • 2012
  • Objectives : The purpose of this study is to review on current status of use and measurement condition of heart rate variability(HRV) by reviewing clinical studies published in journal of Korean medicine registered Korea citraion index(KCI). Methods : One hundred twenty articles were found by searching the representative Korean databases. At first analysis was performed by current status of use(journal, academic field of corresponing author, purpose of study, disease of subject, HRV measurement devices, intervention methods and tests compared to HRV). At second analysis was performed by measurement condition(uncontrolled study, relaxation before measurement, measurement position, measurement place, measurement time period and restriction of smoking, alcohol, caffeine, meal). Results : The analysis showed that department of acupuncture & moxibustion, department of oriental neuropsychiatry are major part in journal & academic field. The purpose of study were classified under studies to verify therapeutic effect on normal subject(39%), to verify therapeutic effect on the patients(8%), to investigate characteristics of the patients(34%) and to be compared with other test(19%). Disease of subject & measurement devices in article were so various. Major intervention methods were acupuncture(61.4%), mind-body intervention(19.2%). Studies that measurement condition were not controlled were relax time(24%), measurement position(19%), measurement place(26%), measurement time period(91%) and restriction of smoking, alcohol, caffeine, meal(49%). Conclusions : This study showed that current status of use of HRV is widespread in Korean medicine but more controlled measurement conditon are needed to get more reliable result from clinical studies and to improve diagnosis and treatment of Korean medicine.

Geomagnetic Field Monitoring at King Sejong Station, Antarctica (남극 세종기지에서의 지자기 모니터링)

  • Kim, DonIl;Jin, YoungKeun;Nam, SangHeon;Lee, JooHan
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.1
    • /
    • pp.11-21
    • /
    • 2004
  • The variation of geomagnetic field and absolute magnetic field at the geomagnetic observatory of King Sejong Station has been measured with 3-component ring core fluxgate magnetometer, proton magnetometer and D-I magnetometer. With data obtained from King Sejong Station during 2003, thediurnal and annual variations of geomagnetic field were researched and compared with those at other observatories. The deviation of daily variation of magnetic field in antarctica decreased gradually during winter season due to sun effect. The rates of componental annual variation of magnetic field at King Sejong Station were calculated using the least-square method under the assumption that the annual variation of magnetic field is linear. The rates are -55.93 nT/year in horizontal intensity, -0.87 min./year in declination, 58.30 nT/year in vertical intensity, and -69.85 nT/year in total intensity of magnetic field. A remarkable variation was caused by the magnetic storms occurred on 29~30 October, which were so powerful that the variation was observed in mid latitudes as well as high latitudes. The values of variation are generally 1500 2000 nT in Antarctica including King Sejong Station, 350 500 nT in East Asia. The measurement of absolute magnetic field shows that ring core fluxgate magnetometer has relatively large error range under cold temperature.

  • PDF

Development of an Uplift Measurement System for Overhead Contact Wire using High Speed Camera (고속카메라를 이용한 전차선 압상량 검측 시스템 개발)

  • Park, Young;Cho, Yong-Hyeon;Lee, Ki-Won;Kim, Hyung-Jun;Kim, In-Chol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.864-869
    • /
    • 2009
  • The measurement of contact wire uplift in electric railways is one of the most important test parameters to accepting the maximum permitted speed of new electric vehicles and pantographs. The contact wire uplift can be measured over short periods when the pantograph passes monitoring stations. In this paper, a high-speed image measurement system and its image processing method are being developed to evaluate dynamic uplift of overhead contact wires caused by pantograph contact forces of Korea Tilting Train eXpress (TTX) and Korea Train eXpress (KTX). The image measurement system was implemented utilizing a high-speed CMOS (Complementary Metal Oxide Semiconductor) camera and gigabit ethernet LAN. Unlike previous systems, the uplift measurement system using high speed camera is installed on the side of the rail, making maintenance convenient. On-field verification of the uplift measurement system for overhead contact wire using high speed camera was conducted by measuring uplift of the TTX followed by operation speeds at the Honam conventional line and high-speed railway line. The proposed high-speed image measurement system to evaluate dynamic uplift of overhead contact wires shows promising on-field applications for high speed trains such as KTX and TTX.

Investigation of the heavy-weight floor impact sound field in a testing building with bearing wall structure (벽식구조 표준시험동에서 중량충격음장에 관한 연구)

  • Yoo, Seung-Yup;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.969-973
    • /
    • 2007
  • The heavy-weight floor impact sound field of the receiving room in a testing building with bearing wall structure was investigated using bang machine and impact ball. The sound field was investigated through the impact sound pressure level distribution by the field measurement and computational analysis. Predicted sound field using the computational analysis agree with measurement result in the low frequency band. Result shows that standard deviations of the single number rating value are about 2dB in each impact source. Particularly, impact sound pressure level at 120cm height in 63Hz octave band was 5dB lower than spatial averaging value. It was found that receiving positions in the ministry of construction and transportation notice should be reconsidered.

  • PDF

Magnetic Field Distribution of Power Line Using Amorphous Wire (아몰포스선을 이용한 전력선의 자계분포)

  • Moriyama, T.;Cho, M.W.;Hikita, M.;Hong, J.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.609-612
    • /
    • 2001
  • To investigate the magnetic field distribution of power line, we used amorphous wire sensor. And we discuss extremely low frequency magnetic field distribution dependent upon arrangement of power line and shielding pipe made from iron or alumimum materials by both measurement and FEM(Finite Element Method) analysis. Appling current of single phase 60 [Hz] 15 [A] is supplied to copper wire coated enamel resign. As the results, we confirmed that linear characteristics of amorphous wire sensor is very excellent and measurement value agrees with FEM calculation. Magnetic field distribution due to shielding materials is changed by permeability and conductivity.

  • PDF

Field Application of Power Cable Diagnosis System (전력케이블 열화진단기법의 현장적용)

  • Kim, Ju-Yong;Han, Jae-Hong;Song, Il-Keun;Kim, Sang-Jun;Lee, Jae-Bong;Oh, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

Temperature field measurement of convective flow in a Hele-Shaw Cell with TLC and color image processing (TLC와 컬러화상처리를 이용한 Hele-Shaw Cell 내부 대류 온도장 측정)

  • Yun, Jeong-Hwan;Do, Deok-Hui;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.3
    • /
    • pp.1114-1122
    • /
    • 1996
  • Variation of temperature field in a Hele-Shaw convection cell was measured by using a HSI true color image processing system and TLC(Thermochromic Liquid Crystal) solution. The relationship between the hue value of TLC color image and real temperature was obtained and this calibration result was used to measure the true temperature. The temperature field in the Hele-Shaw convection cell shows periodic characteristics of 45 sec at Ra = 9.3 * 10$\^$6/. The temperature field measurement technique developed in this study was proved to be a useful and powerful tool for analyzing the unsteady thermal fluid flows.