• Title/Summary/Keyword: Fibrin adhesive

Search Result 25, Processing Time 0.027 seconds

Surgical Treatment of Spontaneous Pneumothorax by Thoracoscopic Wedge Resection with Fibrin Glue (비디오흉강경을 이용한 자연기흉의 치료시 국소적 Fibrin Glue 도포)

  • 신화균
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.812-816
    • /
    • 2000
  • Background ; To evaluate the efficacy of Fibrin glue to decrease recurrence in video-assisted thoracoscopic surgery(VATS) for a treatment of spontaneous penumothorax. Material and Method : All medical records of 17 patients who underwent a thoracoscopic wedge resections of bullae with stapling device with Fibrin glue in our institute between May 1998 and December 1999 were reviewed. variables analyzed include affected sites primary indication of VATS. duration from admission to discharge duration of postoperative stay duration of chest tube drainage recurrence and complication. There were 16 men and 1 woman. Result : There was no evidence of hemodynamic instability or arterial blood gas abnormalities encountered during the procedure. Mean age at the time of the VATS was 26.9 years (range 15 to 61 years) The mean duration from admission to discharge was 7.8 days and mean postoperative stay was 5.1days mean chest tube indwelling period was 4..0 days. There was no recurrence of pneumothorx. Conclusion : Thoracoscopic wedge resections with introduction of fibrin glue are safe and effective and requires only a short hospital stay. We believe that this thoracoscopic technique will further simplify the surgical treatment of pneumothorax.

  • PDF

THE FIBRIN-ADHESIVE SYSTEM IN MUCOSAL GRAFT VESTIBULOPLASTY (조직접착제를 이용한 점막이식 전정성형술)

  • Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.2
    • /
    • pp.130-136
    • /
    • 1995
  • Vestibuloplasty are following categories : Mucosal advancement(submucous), secondary epithlization(reepithelization) and grafting vestibuloplasty. Although certain procedures are indicated for alveolar bone loss and sulcus shortening, relapse can occur. Every efforts to minimize or compensate for it is controversy. O'Steen(1970) reported the mucous graft methods that none of vestibular shrinkage and graft contracture. 15patients in mucous graft vestibuloplasty with fibrin adhesive system(Beriplast) were taken in cases of alveolar bone resorption and mucosal shortening due to traumatized alveolar bone defects, senile atrophic alveolar bone, postoperative cyst or tumor resection, edentulous alveolar bone loss, and others. A technique in the use of small piece of palatal mucosa$(1{\times}20mm)$ from the lateral aspect of the palate with adhesive system provided to secure the skin grafts, avoid stent fixation, postoperative patient's comfort and less time-consuming than the standard technique, especially excellent bleeding control.

  • PDF

HISTOLOGIC STUDY OF THE AUTOGENOUS AURICULAR CARTILAGE GRAFTS IN THE RABBITS FEMER (가토 대퇴골에 이식한 자가 이연골에 관한 조직학적 연구)

  • Sung, Gil-Hyun;Kim, Eun-Cheol;Min, Seung-Ki;Lee, Dong-Keun;Kim, Soo-Nam
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.1
    • /
    • pp.49-61
    • /
    • 1993
  • The transplantation of cartilage, especially auricular cartilage, has assumed a role of importance in the field of plastic and reconstructive surgery. From long years ago, many reports have appeared in the literature describing the experimental and clinical results of the use of cartilage. At present, the evidence for survival of autograft of cartilage is admitted, But, the results for interrelationship between the bone and cartilage grafts with or without perichondrium is not so conclusive. The purpose of this study were observed as to whether autogenous cartilage grafts were fixed by means of tie with 4-0 vicryl and fibrin adhesive on the femur or microscopic findings of union state in 16 rabbits. We sacrified the experimental animals after 1, 2, 4, 6 weeks postoperatively and made the specimens as a routine laboratory procedures and stained with Hematoxylin-Eosin stain, Verhoeff-van Gieson elastic fiber stain, and alcian blue periodic acid-Schiff(AB-PAS) for mucopolysaccharide. Histologic evaluation was performed under microscope. The obtaind results were as follows : 1. Fibrous union was formed between the grafting cartilage and the femur, nor any findings of calcification and formation of new bone. 2. Partial fibrous adhesion was observed in fibrin adhesive groups on 6 weeks postoperatively. 3. Appositional growth has performed more in fibrin adhesive groups than tie groups. 4. There are little difference in both for new copillary proliferation and fibroblast activations. 5. Degenerative changes have apperared more in tie groups than adhesive groups, but not related to the healing periods.

  • PDF

Does Fibrin Sealant Reduce Seroma after Immediate Breast Reconstruction Utilizing a Latissimus Dorsi Myocutaneous Flap?

  • Cha, Han Gyu;Kang, Sang Gue;Shin, Ho Seong;Kang, Moon Seok;Nam, Seung Min
    • Archives of Plastic Surgery
    • /
    • v.39 no.5
    • /
    • pp.504-508
    • /
    • 2012
  • Background The most common complication of latissimus dorsi myocutaneous flap in breast reconstruction is seroma formation in the back. Many clinical studies have shown that fibrin sealant reduces seroma formation. We investigated any statistically significant differences in postoperative drainage and seroma formation when utilizing the fibrin sealant on the site of the latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction after skin-sparing partial mastectomy. Methods A total of 46 patients underwent immediate breast reconstruction utilizing a latissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedure without fibrin sealant and the other 23 were administered the fibrin sealant. All flaps were elevated with manual dissection by the same surgeon and were analyzed to evaluate the potential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U test were used for analyzing the drainage volume according to age, weight of the breast specimen, and body mass index. Results Although not statistically significant, the cumulative drainage fluid volume was higher in the control group until postoperative day 2 (530.1 mL compared to 502.3 mL), but the fibrin sealant group showed more drainage beginning on postoperative day 3. The donor site comparisons showed the fibrin sealant group had more drainage beginning on postoperative day 3 and the drain was removed 1 day earlier in the control group. Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Because the benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussed with patients before its use as a part of informed consent.

APPLICATION OF FIBRIN ADHESIVE IN DISK REPLACEMENT AFTER MENISCECTOMY (관절원판 절제술후 중간삽입물 고정에 피브린 접착제의 응용)

  • Chung, Hoon;Kim, Hyeong-Keun;Kim, Young-Soo;Yu, Ki-Jun;Ahn, Byoung-Guen
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.3
    • /
    • pp.175-184
    • /
    • 1992
  • Meniscectomy is indicated for the internal derangement of disk with perforation and gross morphological changes, nonreactive to conservative treatment procedures. After the meniscectomy, permanent disk replacement can be followed. Variable materials have been introduced for disk replacement. Of them, relatively harder replacing materials should have been fixed with surgical wire only. This poor fixation method provide inadequate retentive force and conclusively can be attributed to postoperative noise, poor prognosis. We tried to use biocompatible fibrin adhesive in order to obtain additional fixation force in the method above mentioned and treated two patients with the late stage of internal derangement of disk In both cases, satisfactory results were obtained.

  • PDF

Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report

  • Shin, Jin Yong;Lee, Nae-Ho;Kim, Min-Seok;Roh, Si-Gyun;Chung, Yoon Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.5
    • /
    • pp.228-231
    • /
    • 2022
  • Fibrin glue is a topical agent widely used for hemostasis, wound healing, and surgical adhesion. Complications of fibrin glue itself are extremely rare because it is absorbed over time, but can occur as a result of inappropriate application. We report a case of a postoperative complication caused by inappropriate application of fibrin glue in blow-out fracture surgery. A 65-year-old male patient presented with periorbital swelling and an open wound on the right infraorbital area. Computed tomography showed a right orbital floor fracture. After reduction of the herniated tissue into the orbit, an implant was inserted and fibrin glue was applied to stabilize the implant. This procedure was performed without difficulty, but the patient complained of persistent diplopia and limited eyeball movement after surgery. An imaging study showed a mass-like lesion, which was not a hematoma, in the orbital cavity. In a second operation, the mass was identified as clotted fibrin glue that had not been applied properly. After removal, the patient's symptoms were relieved without further complications. Appropriate and careful application of fibrin glue is necessary to avoid unnecessary complications.

Evaluation of Cumulative and Conditional Antibiotic Release from Vancomycin-Embedded Fibrin Sealant and Its Antibacterial Activity : An In Vitro Study

  • Shin, Dong-Won;Sohn, Moon-Jun;Cho, Chong-Rae;Koo, Hae-won;Yoon, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.1
    • /
    • pp.45-55
    • /
    • 2020
  • Objective : Fibrin sealants have been used for hemostasis, sealant for cerebrospinal fluid leakage, and adhesive barrier in neurosurgery. Further, as its clinical use and role of an effective drug delivery vehicle have been proposed. This study was performed to measure antibacterial activity and continuous local antibiotic release from different concentrations of vancomycin-impregnated fibrin sealant in vitro. Methods : Antibacterial activity was investigated by disk diffusion test by measuring the diameter of the growth inhibition zone of bacteria (methicillin-resistant Staphylococcus aureus, ATCC29213) from vancomycin-embedded fibrin sealant disc diluted at five different concentrations (C1-C5; 8.33, 4.167, 0.83, 0.083, and 0.0083 mg/disc, respectively). Continuous and conditioned release of vancomycin concentration (for 2 weeks and for 5 days, respectively) were also measured using high-performance liquid chromatography (HPLC) method. To mimic the physiologic wound conditions with in vitro, conditioned vancomycin release in phosphate buffer solution (PBS) was measured and replaced PBS for five consecutive days, half a day or completely daily. Results : In the disk diffusion test, the mean diameters of bacterial inhibition zone were 2.54±0.07 cm, 2.61±0.12 cm, and 2.13±0.15 cm (C1, C2, and C3 respectively) but 1.67±0.06 cm and 1.23±0.15 cm in C4 and C5, respectively. Continuous elution test elicited the peak release of vancomycin from the fibrin sealant at 48 hours, with continued release until 2 weeks. However, conditioned vancomycin release decreased to half or more on day 2, however, the sustainable release was measured over the therapeutic dose (10-20 ㎍/mL) for 5 days and 4 days in assays of half and total exchange of PBS. Conclusion : This study suggests that fibrin sealant can provide an efficient vehicle for antibiotic drug release in a wide range of neurosurgical procedures and the safe and effective therapeutic dose will be at the concentration embedded of 4.167 mg/disc or more of vancomycin.

The Covering of the Suture Area with an Absorbable Cellulose Mesh and Fibrin Glue in Bullectomy of Primary Spontaneous Pneumothorax (일차성 자연기흉의 수술시 흡수성 셀룰로스 망사 및 Fibrin glue의 도포와 재발에 대한 임상적 고찰)

  • 허동명;김병호
    • Journal of Chest Surgery
    • /
    • v.34 no.5
    • /
    • pp.393-398
    • /
    • 2001
  • 배경: 일차성 자연기흉의 재발방지를 위해서 폐기포절부위에 흡수성 셀룰로스망사와 Fibrin gluefm 도포하여 수술후 재발율을 줄일 수 있는 지 알아보았다. 대상 및 방법: 1996.4우러부터 2000.6월까지 2명의 술자가 222례의 일차성 자연기흉을 수술하였으며, 수술시기와 치료방법에 따라 4군으로 나누어 비교하였다. 제1군은 1996년부터 1997년가지 비디오흉강경수술 및 기계적 늑막유착술로 시술받은 군(25례), 제 2군은 같은 기간동안 액와개흉술 및 늑막유착술로 시술받은 군(53례), 제 3군은 1998년부터 2000.4월까지 흉강경수술 및 늑만유착술로시술받은 군(110례), 제 4군은 1999.7월부터 2000.6월까지 흉강경수술 및 봉합부위를 셀룰로스망사와 Fibrin glue로 보강한 군(34례)이었다. 각 군간, 엑스선상 기흉의 크기 및 폐기포의 수나 크기에 따라 재발율, 공기누출시간 및 흉관지속지간등을 일반선형모델을 사용하여 비교 분석하였다. 결과: 대상환자는 남자 203례, 여자 19례 이었고, 나이는 14게에서 68세이었고, 평균연령은 23.2$\pm$9.6세였다. 재발한 경우는제 1군이 5례(25%), 제 2군이 2례(3.8%), 제 3군이 5례(4.5%)이었고, 제 4군은 재발례가 없었다. 재발례는 모두 수술자의 수술경험이 2년이내일 때 발생하였다. 흉관지속기간은 제 4군이 제 3군(p<0.0006) 및 제1, 제2군(p<0.0001)에 비해서 더 짧았고, 술후 공기누출이 제 4군에서는 없었다. 술전흉부엑스선상 기흉의 크기에 따른 수술후 기흉의 재발울은 경도의 기흉에서 14.3%(2/14)이었고, 중등도 기흉에서 7.4%(10/134)이었으며, 심한 기흉에서는 재발례가 없었다. 재수술한 12례중 봉합부위근처에서 기포가 발행된 경우가 9례(75%)로 많았다. 결론: 재발방지를 위한 시술로 늑막유착술을 시행하지 않고 폐기포절제부위를 흡수성 셀룰로스망사와 Fibrin glue로 덮어주는 시술은 비교적 용이하며, 수술 후 공기 누출이 없었고, 수술 후 흉관지속기간이 더 짧았고, 단기간 추적에서 재발이 없었다. 재발에 영향을 미치는 것으로 흉부엑스선상 기흉의 크기가 작은 경우에는 재발율이 더 높았고, 수술자의 경험이 중요하였다.

  • PDF

Fibrin Sealant and Lipoabdominoplasty in Obese Grade 1 and 2 Patients

  • Mabrouk, Amr Abdel Wahab;Helal, Hesham Aly;Al Mekkawy, Soha Fathy;Mahmoud, Nada Abdel Sattar;Abdel-Salam, Ahmed Mohamed
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.621-626
    • /
    • 2013
  • Background Ever since lipoabdominoplasty was first developed to achieve better aesthetic outcomes and less morbidity, the rate of seroma formation, especially in obese patients, has disturbed plastic surgeons. The aim of this study was to evaluate the effect of fibrin sealant in the prevention of seroma formation after lipoabdominoplasty in obese patients. Methods Sixty patients with a body mass index (BMI) between 30 and 39.9 were assigned randomly to 1 of 2 groups (30 patients each). Group A underwent lipoabdominoplasty with fibrin glue, while group B underwent traditional lipoabdominoplasty; both had closed suction drainage applied to the abdomen. The patients' demographics and postoperative complications were recorded. Seroma was detected using abdominal ultrasound examinations at two postoperative periods: between postoperative days 10 and 12 and, between postoperative days 18 and 21. Results The age range was 31 to 55 years ($38.5{\pm}9.5$ years) in group A and 25 to 58 years ($37.8{\pm}9.1$ years) in group B, while the mean BMI was 31.4 to 39.9 $kg/m^2$ (32.6 $kg/m^2$) in group A and 32.7 to 37.4 $kg/m^2$ (31.5 $kg/m^2$) in group B. In group A, the patients had a complication rate of 10% in group A versus 43% in group B (P<0.05). The incidence of seroma formation was 3% in the fibrin glue group but 37% in the lipoabdominoplasty-alone group (P<0.05). Conclusions Lipoabdominoplasty with the use of autologous fibrin sealant is a very effective method that significantly reduces the rate of postoperative seroma.