• Title/Summary/Keyword: Fiber-optic interferometer

Search Result 103, Processing Time 0.021 seconds

Sound Pressure Sensitivity Variation of the Hollow Cylinder Type Sagnac Fiber Optic Sensor According to the Mandrel Install Direction and Its Material (Sagnac형 광섬유 센서를 이용한 중공 원통형 맨드릴의 재료 및 설치 방향에 따른 음압 감지 변화 연구)

  • Lee, Jong-Kil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.626-633
    • /
    • 2012
  • In this paper, sound pressure sensitivity of the fiber optic acoustic sensor according to sensor direction and mandrel material were investigated experimentally. Three different directions were selected as stand, lay, and hole. Hollow cylinder type mandrel dimension is 30 mm in outer diameter, 45 mm in length, and 2 mm in thickness, and about 50 m optical fibers were wounded on the surface of the mandrel. Non-directional sound speaker was used as a sound source. Sagnac interferometer and single mode fiber, a laser with 1,550 nm in wavelength, $2{\times}2$ coupler were used. Based on the experimental results, lay direction's sensitivity is the highest in the frequency range of 2 kHz~4 kHz. 'PTFE+carbon' material is more sensitive than PTFE in the frequency range of 5 kHz~20 kHz. Sound pressure detection sensitivity depends on the mandrel direction and material under certain frequency.

Experimental Analysis of Flow Induced Vibration Measurement Using Fiber Optic Sensor (광섬유 센서를 이용한 유체유기진동의 실험적 측정 연구)

  • Lee, Jongkil
    • 대한공업교육학회지
    • /
    • v.34 no.1
    • /
    • pp.274-286
    • /
    • 2009
  • Fiber optic sensor is widely used in measuring acoustic and vibration. Especially interferometric sensors are more suitable to measure the acoustic signal. In this paper, a Fabry-Perot interferometric fiber optic sensor was used to measure flow induced vibration. This vibration also measured using an accelerometer, and the data was compared to one other. The venture, nozzle, drop barrel, and rapid expansion in the pipeline are the measuring objects. The flow rate is changed from 50 L/min to 150 L/min and the average flow velocity was about 7 m/s. Based on the experimental results the suggested fiber optic sensor detects flow induced vibration effectively. Therefore, this kind of fiber optic sensor can be applied to the monitoring the flow induced noise and vibration such as pipelines, cables, buildings.

Investigation of Sound Pressure Detection of Fiber Optic Sensor in Transformer Oil According to TLS and CW Laser Source (TLS와 CW 광원에 따른 트랜스포머 오일 내에서 광섬유 센서의 음압 감지 특성 연구)

  • Lee, Jong-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.33-41
    • /
    • 2011
  • To substitute TLS in the hybrid system which is combined with Sagnac interferometer and fiber bragg grating (FBG) it is necessary to investigate how the laser source (TLS and CW) and sensor material variate the response of fiber optic sensor. Two different hollow cylinder type mandrel materials are proposed which are PTFE and PTFE+carbon and 18 m optical fiber is wounded at the mandrel surface. CW laser source experiments had been done in the oil tank which is filled with transformer oil in the 1 kHz~20 kHz frequency range. Also Sagnac interferometer fiber optic sensor is combined with FBG called hybrid system and TLS used as a light source. Based on the experimental results PTFE sensor showed more higher magnitude of detection signal rather than carbon sensor and this result is agreement with the McMahon's theoretical results. Phase variation is inversely proportional to the elastic modulus of the mandrel material. In PTFE fiber sensor, tunable laser source showed more higher performance rather than CW case. Therefore, TLS fiber optic sensor can be applied to the hybrid system which is combined with Sagnac and FBG.

Thermal Strain and Temperature Measurements of Structures by Using Fiber-Optic Sensors (광섬유 센서를 이용한 구조물의 열변형 및 온도 측정)

  • 강동훈;강현규;류치영;홍창선;김천곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.04a
    • /
    • pp.184-189
    • /
    • 2000
  • Two types of fiber-optic sensors, EFPI(extrinsic Fabry-Perot interferometer) and FBG(fiber Bragg grating), have been investigated for measurement of thermal strain and temperature. The EFPI sensor is only for measurement of thermal strain and the FBG sensor is for simultaneous measurement of thermal strain and temperature. FBG temperature sensor was developed to measure strain-independent temperature. This sensor configuration consists of a single-fiber Bragg grating and capillary tube which makes it isolated from external strain. This sensor can then be used to compensate for the temperature cross sensitivity of a FBG strain sensor. These sensors are demonstrated by embedding them into a graphite/epoxy composite plate and by attaching them on aluminum rod and unsymmetric graphitelepoxy composite plate. All the tests were conducted in a thermal chamber with the temperature range $20-100^{\circ}C$. Results of strain measurements by fiber-optic sensors are compared with that from conventional resistive foil gauge attached on the surface.

  • PDF

Demodulation of FBG and Acoustic Sensors Embedded in a Fiber-Optic Sagnac Loop (광섬유 사낙간섭계에 삽입된 광섬유격자센서와 음향센서의 복조)

  • Kim, Hyun-Jin;Lee, June-Ho;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.44-50
    • /
    • 2012
  • When the fiber Bragg gratings are embedded in a fiber-optic Sagnac loop for measuring temperature or strain, it is difficult to separate the Bragg wavelengths. The transmitted light is mixed with the reflected Bragg wavelengths in the photo-detector, working as noises. To suppress the noises, we placed the FBG sensors and a fiber-optic attenuator at asymmetric positions in the loop. With the arrangement the reflected light became much bigger than the transmitted light, enabling the separation of the reflected Bragg wavelengths with almost the same signal-to-noise ratio of the FBG sensors outside the loop.

Characteristics of Underwater Sound Detection of the Fiber Optic Hydrophone Array (광섬유 하이드로폰 배열의 수중음향 감지특성 연구)

  • Lee, Jong-Kil
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.102-107
    • /
    • 1999
  • In this paper, to develop the fiber optic hydrophone for the use of low frequency applications, two channels TDM(Time Division Multiplexing) fiber-optic hydrophone array was fabricated and their acoustic charateristics were investigated in the acoustic water tank. A fiber length of the order of 150m is wounded at the hollow cylinder type aluminum mandrel and the fundamental natural frequency of the mandrel maintained above 10kHz. An unbalanced interferometer (discrete Mach-Zehnder type) was used. Sound detection performance is tested in the underwater tank with 3kHz continuous sound source. Finally, it is shown that two channels TDM fiber-optic hydrophone array can detect 3kHz sound stably. This results can also applicable for the development of multi-channel fiber optic hydrophone array.

  • PDF

A study on stabilization of a fiber-optic current sensor using sagnac interferometer (Sagnac 간섭계형 광섬유 전류센서의 안정화 연구)

  • 정래성;강현서;이종훈;송정태;이경식
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.4
    • /
    • pp.94-99
    • /
    • 1997
  • A new method of stbilizing the sagnac interferometric fiber optic current sensor inteh presence of birefringences and phase is presented. This method is realized by dividing the output of the ac current signal with the modulation signal output. Using the technique the stability of the current sensor was improve dmore than 4.5 times at 800Arms for 2 hours. The current sensor also shows good linearity up to 100Arms.

  • PDF

COMMOM MODE COMPENSATION IN FIBER OPTIC INTERFEROMETRIC SENSOR WITH LESS COHERENT LIGHT

  • Park, Kyung-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1108-1111
    • /
    • 1990
  • Sorce noise effect in 1.5 Mach-Zehnder (MZ) interferometer is analyzed. It is shown numerically that with fine adjustments to the feedback gain and initial phase biases, the operating point of the interferometer to achives common mode compensation can be made to lie in a region where the measurand sensitivity is greater than it would be in a conventional Mach-Zehnder interferometer even if the source is less coherent.

  • PDF

A simultaneous wavelength tuning and stabilization scheme of a fiber-optic interferometer filter

  • Ahn, Joon-Tae;Lee, Hak-Kyu;Jeon, Min-Yong;Lim, Dong-Sung;Kim, Kyong-Hon
    • Journal of the Optical Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.32-34
    • /
    • 1999
  • We successfully demonstrated a stabilized fiber-optic Mach­Zehnder interferometer filter with continuous tunability. The tunable scheme was achieved with fine wavelength control of an 1.3${\mu}{\textrm}{m}$ tunable laser diode used as a stabilization light source. The transmission wavelength of the tunable filter was shifted linearly with respect to the wavelength change of the stabilization light source.