휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정 (Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System)

  • 강나루;우영아;차봉수;이현철;김효진
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

FIBER OPTIC SENSOR FOR IN-SITU AND REALTIME MONITORING OF TRANSPORT OF GAS PHASE OZONE IN UNSATURATED POROUS MEDIA

  • Jung, Hae-Ryong;Park, Hee-Chul
    • Environmental Engineering Research
    • /
    • 제10권2호
    • /
    • pp.71-78
    • /
    • 2005
  • A series of column experiments was conducted to develop a monitoring system for in-situ and realtime measurement of ozone transport in unsaturated porous media using a fiber optic sensor. The calibration of the fiber optic transflection dip probe (FOTDP) system was successfully carried out at various ozone concentrations using a column with length of 30 cm and diameter of 5 cm packed with glass beads, which don't react with gaseous ozone. The breakthrough curves (BTCs) of ozone were obtained by converting the normalized intensity into ozone concentration. The FOTDP system worked well for in-situ monitoring of gas phase ozone at various water saturations and in presence of soil organic matter (SOM). However, the FOTDP system did not measure the ozone concentration at more than 70% water saturation.

베타/감마 동시 측정용 광섬유 이중 검출기의 개발을 위한 기초연구 (Feasibility Study on Development of a Fiber-Optic Dual Detector to Measure Beta- and Gamma-rays Simultaneously)

  • 홍승한;신상훈;심혁인;김선근;전혜수;장재석;김재석;권구원;장경원;유욱재;이봉수
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.284-290
    • /
    • 2014
  • A fiber-optic beta/gamma dual detector system with two types of sensing probes was fabricated to detect the beta- and gamma-rays simultaneously. As scintillators of the sensing probe type 1, two different inorganic scintillators, $CaF_2(Eu)$ and LYSO(Ce) crystals, were used to obtain the each scintillating efficiency with respect to beta-and gamma-rays and the inherent energy spectra of radioactive isotopes. In the case of the sensing probe type 2, which is composed of two identical inorganic scintillators and a beta shielding material based on the lead, it could discriminate beta- and gamma-rays using a subtraction method. In conclusion, we demonstrated that the proposed fiber-optic beta/gamma dual detector could measure and discriminate beta- and gamma-rays using both energy spectroscopy and subtraction method.

Optimized Working Distance of a Micro-optic OCT Imaging Probe

  • Kim, Da-Seul;Moon, Sucbei
    • Current Optics and Photonics
    • /
    • 제4권4호
    • /
    • pp.330-335
    • /
    • 2020
  • We have investigated optimization of the working distance (WD) for a highly miniaturized imaging probe for endoscopic optical coherence tomography (OCT). The WD is the axial distance from the distal end of the imaging probe to its beam focus, which is demanded for dimensional margins of protective structures, operational safety, or full utilization of the axial imaging range of OCT. With an objective lens smaller than a few hundred micrometers in diameter, a micro-optic imaging probe naturally exhibits a very short WD due to the down-scaled optical structure. For a maximized WD careful design is required with the optical aperture of the objective lens optimally filled by the incident beam. The diffraction-involved effect was taken into account in our analysis of the apertured beam. In this study, we developed a simple design formula on the maximum achievable WD based on our diffraction simulation. It was found that the maximum WD is proportional to the aperture size squared. In experiment, we designed and fabricated very compact OCT probes with long WDs. Our 165-㎛-thick fiber-optic probes provided WDs of 3 mm or longer w ith reasonable OCT imaging performance.

Milk Fat Analysis by Fiber-optic Spectroscopy

  • Ohtani, S.;Wang, T.;Nishimura, K.;Irie, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.580-583
    • /
    • 2005
  • We have evaluated the application of spectroscopy using an insertion-type fiber-optic probe and a sensor at wavelengths from 400 to 1,100 nm to the measurement of milk fat content on dairy farms. The internal reflectance ratios of 183 milk samples were determined with a fiber-optic spectrophotometer at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$. Partial least squares (PLS) regression was used to develop calibration models for the milk fat. The best accuracy of determination was found for an equation that was obtained using smoothed internal reflectance data and three PLS factors at 20$^{\circ}C$. The correlation coefficients between predicted and reference milk fat at 5$^{\circ}C$, 20$^{\circ}C$ and 40$^{\circ}C$ were r=0.753, r=0.796 and r=0.783, respectively. The predictive explained variances ($Q^2$) of the final model, moreover, were more than 0.550 at all temperatures, and the regression coefficients of determination ($R^2$) were more than 0.6 (60%). Our results indicate that milk has different internal reflectance measured in the range of visible and near infrared wavelengths (400 to 1,100 nm), depending on its fat content.

광섬유 Sagnac 간섭계를 이용한 초음파의 비접촉식 감지 (Non-contact Detection of Ultrasonic Waves Using Fiber Optic Sagnac Interferometer)

  • 이정주;장태성;이승석;김영길;권일범;이왕주
    • 대한기계학회논문집A
    • /
    • 제25권9호
    • /
    • pp.1400-1409
    • /
    • 2001
  • This paper describes a fiber optic sensor suitable for non-contact detection of ultrasonic waves. This sensor is based on a fiber optic Sagnac interferometer. Quadrature phase bias between two interfering laser beams in Sagnac loop is introduced by a polarization controller. A stable quadrature phase bias can be confirmed by observing the interferometer output versus phase bias. This method eliminates a digital signal processing for detection of ultrasonic waves using Sagnac interferometer. Interference intensity is affected by the frequency of ultrasonic waves and the time delay of Sagnac loop. Collimator is attached to the end of the probing fiber to focus the light beam onto the specimen surface and to collect the reflected light back into the fiber probe. Ultrasonic waves produced by conventional ultrasonic transducers are detected. This fiber optic sensor based on Sagnac interferometer is very effective for detection of small displacement with high frequency such as ultrasonic waves used in conventional non-destructive testing.

광섬유 사냑 간섭형 센서에 기반한 링형 탐촉자의 수중 음향 민감도 해석 (Acoustic Sensitivity Analysis of a Ring-type Probe Based on a Fiber-optic Sagnac Interferometric Sensor)

  • 이연우;권휴상;권일범
    • 한국광학회지
    • /
    • 제31권1호
    • /
    • pp.13-19
    • /
    • 2020
  • 광섬유 사냑 간섭형 센서를 이용해 수중 음향을 측정하기 위하여 링형 탐촉자를 적용하는 경우 민감도를 이론과 실험을 통하여 조사한다. 링형 탐촉자는 단일 모드 광섬유를 지름 5 cm의 링형으로 감아서 접착제로 패키징하였다. 링형 탐촉자는 감지 광섬유의 길이를 46.84 m로 하여 제작한 A형 탐촉자와 감지 광섬유의 길이를 112.22 m로 한 B형 탐촉자를 준비하였다. 수중 음향 시험은 상용 음향 발생기와 1 m 떨어진 거리에서 링형 탐촉자를 사용하여 50, 70, 90 kHz의 주파수에 대하여 20~100 Pa의 음향 압력 범위에서 음향 민감도를 조사하는 실험을 수행하였다. 실험 결과, 링형 탐촉자는 주파수에 대하여 다른 민감도를 나타내었으며, 이론과 비교하기 위하여 평균값을 구하였다. 세 주파수에 대한 평균 민감도는 A 탐촉자와 B 탐촉자에 대하여 각각 25.48 × 10-5, 60.79 × 10-5 rad/Pa으로 측정되었으며, 이로부터 영률 보정 계수 c값을 0.35로 결정할 수 있었다.

Skin depth profiling by using fiber optic probes in the near infrared

  • Woo, Young-Ah;jung, Suh-Eun;Kim, Hyo-Jin
    • 대한화장품학회:학술대회논문집
    • /
    • 대한화장품학회 2003년도 IFSCC Conference Proceeding Book II
    • /
    • pp.218-218
    • /
    • 2003
  • Recently we showed the prototype portable device for the determination of human skin moisture by using near infrared spectroscopy. In order to optimize the acquiring condition of NIR spectrum of skin and control the target information of water depending the site such as epidermis and dermis, skin depth profiling was investigated changing the distance between illuminations and receiving of radiation in the terminal of fiber probe. The colleted light information could be controlled by changing the distance of the fiber optic probes. It was confirmed that the longer distance we used, the deeper site from the skin surface we could get information from in this study. Four kinds of probes with distances such as 0.03 mm, 0.1 mm, 0.5 mm, and 1.0 mm were used. In addition, the gap size from 0.3 mm to 3.0 mm was studied to control the intensity of water absorbance effectively and to avoid saturation of water absorption. We also investigated the reference materials depending the reflectance ratio for water absorption not to be saturated because of the strong absorptivity of water. Furthermore, spectroscopic information regarding free water and bound water around 1850 nm was investigated by using the different distance of fiber optic probes. This study would be great help to control the spectroscopic information of water to be measured depending the site where water exists.

  • PDF

뉴트럴레드가 고정화된 다공성 졸-겔 필름을 이용한 고감도 광섬유 pH 센서의 특성 (High-Sensitive Fiber-Optic pH Sensor Using Neutral Red Immobilized in Porous Sol-Gel Film)

  • 전다영;유욱재;신상훈;한기택;박장연;박병기;조승현;이봉수
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.223-228
    • /
    • 2012
  • In this study, a fiber-optic pH sensor based on a pH sol-gel film is fabricated. The sol-gel film is made by co-polymerizing tetramethoxysilane, trimethoxymethylsilane, ethanol and distilled water. As a pH indicator, a neutral red is immobilized in a thin porous film formed by the sol-gel process. The pH change in a sensing probe gives rise to a change in the color of the pH sol-gel film, and the absorbance of reflected light through the pH sol-gel film is also changed. By using a spectrometer, therefore, the spectra of reflected lights in the sensing probe with different pH values are measured. Also, the relationships between the pH values and the absorbance are analyzed on the basis of the color variations of the pH sol-gel films. In repeated experiments, the fiber-optic pH sensor shows that it has reversibility, a high reproducibility and a wide absorbance change in a pH range from pH 5 to 9. Also, we confirmed that the fabricated pH sol-gel film exhibits a fast response time, little or no pH indicator leaching and a dynamic range of 2.04 dB from pH 5 to 9. Based on the results of this study, a fiber-optic pH sensor can be developed for the pH monitoring in the harsh environments.

광섬유와 OTDR을 이용한 실시간 수위 및 온도 측정 (Real-time Measurements of Water Level and Temperature using Fiber-optic Sensors Based on an OTDR)

  • 심혁인;유욱재;신상훈;장재석;김재석;장경원;조승현;문주현;이봉수
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1239-1244
    • /
    • 2014
  • In this study, two fiber-optic sensors were fabricated to measure water level and temperature using optical fibers, a coupler, a Lophine and an OTDR (optical time-domain reflectometer). First, using Fresnel's reflection generated at the distal-ends of each optical fiber, which was installed at different depth, we measured the water level according to the variation of water level. Next, we also measured the temperature of water using a temperature sensing probe based on the Lophine, whose absorbance changes with the temperature. The measurable temperature range of the fiber-optic sensor is from $5^{\circ}C$ to $65^{\circ}C$ because the maximum operation temperature of the optical fiber without a physical deterioration is up to $80^{\circ}C$.