• 제목/요약/키워드: Fiber architecture

검색결과 458건 처리시간 0.06초

멤브레인 형 섬유강화 복합재료의 열팽창 이방성을 고려한 열 기계적 특성 분석 (Analysis of Thermomechanical Properties Considering the Thermal Expansion Anisotropy of Membrane-Type Fiber-Reinforced Composite Material)

  • 정연제;김희태;김정대;오훈규;김용태;박성보;이제명
    • 대한조선학회논문집
    • /
    • 제58권1호
    • /
    • pp.17-23
    • /
    • 2021
  • The membrane-type Liquefied Natural Gas (LNG) cargo tank is equipped with a double barrier to seal the LNG, of which the secondary barrier serves to prevent LNG leakage and mainly uses fiber-reinforced composite materials. However, the composite materials have thermal expansion anisotropy, which deteriorates shape distortion and mechanical performance due to repeated thermal loads caused by temperature changes between cryogenic and ambient during the unloading of LNG. Therefore, in this study, the longitudinal thermal expansion characteristics of the composite materials were obtained using a vertical thermo-mechanical analyzer, and the elastic modulus was obtained through the tensile test for each temperature to perform thermal load analysis for each direction. This is considered that it is useful to secure reliability from the viewpoint of the design of materials for a LNG cargo hold.

강섬유보강 콘크리트와 일반 콘크리트 합성보의 전단강도 (Shear Strength of Steel Fiber Concrete - Plain Concrete Composite Beams)

  • 김철구;박홍근;홍건호;강수민
    • 콘크리트학회논문집
    • /
    • 제27권5호
    • /
    • pp.501-510
    • /
    • 2015
  • 최근 프리캐스트 콘크리트에 현장타설 콘크리트를 타설하는 복합화 공법의 사용이 증가하고 있다. 강섬유 콘크리트는 습식공법에서는 시공성 문제로 적용이 어렵지만, 공장에서 선 제작이 이뤄지는 프리캐스트 부재에는 충분히 사용 가능하다. 강섬유 콘크리트가 복합화 공법에 사용되면 서로 재료적 특성이 다른 강섬유 콘크리트와 일반 콘크리트 합성단면의 전단강도 산정법이 문제가 되고 있다. 하지만 현행 기준은 명확한 기준을 제시하지 못하고 있는 실정이다. 따라서 강섬유 콘크리트가 사용된 합성 부재의 전단강도 실험을 통해 강섬유 콘크리트가 합성단면의 전단강도에 미치는 영향을 살펴보았다. 실험 변수로는 합성단면적비와 전단철근비를 고려하였다. 실험결과를 살펴보면, 강섬유가 인장대에 보강된 경우 강섬유 보강 단면적에 비례하여 전단강도가 증가하였다. 하지만 강섬유의 영향으로 인해 계면에서 수평전단파괴가 쉽게 발생하기 때문에 최소 수평전단철근이 반드시 필요하다.

최소 전단철근 대용으로의 강섬유 콘크리트의 전단기여도 평가 (Evaluation on Shear Contribution of Steel Fiber Reinforced Concrete in Place of Minimum Shear Reinforcement)

  • 김철구;박홍근;홍건호;강수민
    • 콘크리트학회논문집
    • /
    • 제27권6호
    • /
    • pp.603-613
    • /
    • 2015
  • 현행 콘크리트 구조기준에는 전단파괴의 취성적 특성을 고려하여 휨 부재에 최소전단철근을 배근하도록 규정하고 있고, 강섬유 보강 콘크리트 사용시 강섬유가 최소전단철근을 대신하여 사용가능하도록 허용하고 있다. 본 연구에서는 이러한 최소전단철근과 강섬유가 전단강도에 미치는 영향을 단순지지 보 실험을 통해 분석하였다. 실험결과를 살펴보면, 강섬유 보강이 최소 전단철근보다 전단강도에 미치는 영향이 크게 나타났고 특히, 고강도콘크리트가 사용된 경우 강섬유 효과가 크게 발휘되었다. 강섬유 콘크리트의 특성을 살펴보기 위해 기존 실험 자료를 분석하였고 현행 기준에 사용되고 있는 최소전단철근 대용으로의 강섬유 보강 콘크리트 보의 적절성을 평가하였다.

소성힌지부 강섬유 혼입 모르타르 적용 철근콘크리트 기둥의 내진성능평가 (Seismic Performance Evaluation of Reinforced Concrete Columns by Applying Steel Fiber-Reinforced Mortar at Plastic Hinge Region)

  • 조창근;한성진;권민호;임청권
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.241-248
    • /
    • 2012
  • 이 연구에서는, 철근콘크리트 기둥 실험체를 대상으로 기둥의 휨 위험 단면부에 국부적으로 강섬유 시멘트모르타르를 적용함으로서 기존 철근콘크리트 기둥에 비해 내진성능이 우수한 강섬유 모르타르 적용 철근콘크리트 복합기둥공법에 관해 제시하였다. 제시된 적용공법의 성능검증을 위하여 기존 철근콘크리트 기둥 1개 및 소성힌지구간에 국부적으로 강섬유 모르타르를 적용한 복합기둥 실험체 2개를 제작하여 일정 축하중 하에서 횡방향 반복하중을 받는 재하시험을 수행하였다. 콘크리트 및 강섬유 모르타르는 모두 현장타설되었다. 재하시험 결과 기존 철근콘크리트 기둥 실험체와 비교하여 강섬유 모르타르 적용 철근콘크리트 복합기둥 실험체의 경우 휨 및 전단 균열의 제어에 우수할 뿐만 아니라 기둥의 횡하중 내력 및 횡방향 변형 능력 향상에서도 우수한 것으로 평가되었다.

섬유로프 계류시스템의 크리프 효과가 부유체의 운동응답 및 계류선의 장력 변화에 미치는 영향에 관한 연구 (A Study on Creep Effect of Synthetic Fiber Rope Mooring System on Motion Response of Vessel and Tension of Mooring Line)

  • 박성민;이승재;강수원
    • 대한조선학회논문집
    • /
    • 제54권2호
    • /
    • pp.151-160
    • /
    • 2017
  • Growing demand and rapid development of the synthetic fiber rope in mooring system have taken place since it has been used in deep water platform lately. Unlike a chain mooring, synthetic fiber rope composed of lightweight materials such as Polyester(polyethylene terephthalate), HMPE(high modulus polyethylene) and Aramid(aromatic polyamide). Non-linear stiffness and another failure mode are distinct characteristics of synthetic fiber rope when compared to mooring chain. When these ropes are exposed to environmental load for a long time, the length of rope will be increased permanently. This is called 'the creep phenomenon'. Due to the phenomenon, The initial characteristics of mooring systems would be changed because the length and stiffness of the rope have been changed as time goes on. The changed characteristics of fiber rope cause different mooring tension and vessel offset compared to the initial design condition. Commercial mooring analysis software that widely used in industries is unable to take into account this phenomenon automatically. Even though the American Petroleum Institute (API) or other classification rules present some standard or criteria with respect to length and stiffness of a mooring line, simulation guide considers the mechanical properties that is not mentioned in such rules. In this paper, the effect of creep phenomenon in the fiber rope mooring system under specific environment condition is investigated. Desiged mooring system for a Mobile Offshore Drilling Unit(MODU) with HMPE rope which has the highest creep is analyzed in a time domain in order to investigate the effects creep phenomenon to vessel offset and mooring tension. We have developed a new procedure to an analysis of mooring system reflecting the creep phenomenon and it is validated through a time domain simulation using non-linear mooring analysis software, OrcaFlex. The result shows that the creep phenomenon should be considered in analysis procedure because it affects the length and stiffness of synthetic fiber rope in case of high water temperature and permanent mooring system.

Flow and Engineering Properties of Fiber Reinforced Hwangtoh Mortars

  • Mun, Ju-Hyun;Yang, Keun-Hyeok;Hwang, Hye-Zoo
    • 한국건축시공학회지
    • /
    • 제12권3호
    • /
    • pp.332-339
    • /
    • 2012
  • In this study, six mortar mixes were tested in order to examine the significance and limitations of hydrophilic fiber in terms of its capacity to enhance the tensile resistance of Hwangtoh mortar. Lyocell, polyamide and polyvinyl alcohol (PVA) fibers were selected for the main test parameters. The tensile capacity of mortars tested was evaluated based on the splitting tensile strength and the modulus of fracture, while their ductility was examined using the toughness indices specified in ASTM. Test results showed that the addition of lyocell and PVA fibers had little influence on the flow of the Hwangtoh mortars. To enhance the tensile capacity and toughness index of Hwangtoh mortar, it is proposed that fiber spacing above 0.0003 is required, regardless of the type of fiber.

Multiple Brillouin Stokes Generation Utilizing a Linear Cavity Erbium-Doped Fiber Laser

  • AL-Mansoori, Mohammed Haydar;Noordin, Nor Kamariah;Saripan, M. Iqbal;Mahdi, Mohd Adzir
    • Journal of Communications and Networks
    • /
    • 제10권1호
    • /
    • pp.1-4
    • /
    • 2008
  • This paper reports the design of a multiwavelength fiber laser source that utilizes a linear cavity of hybrid Brillouin/Erbium fiber laser (BEFL). The output power, threshold power and free running cavity modes were investigated against the pump powers. The structure exhibited low threshold operation of 4 mW at 2.3 mW injected Brillouin pump power. The optimization of Brillouin pump wavelength, power and Erbium gain led to a maximum possible number of channels generated. Simultaneous and stable operation of 21 channels with 10.88 GHz channels spacing were obtained from this architecture at 1 mW injected Brillouin pump power and 90 m W Erbium doped fiber pump power in the 1555 nm region.

10kW 화이버레이저를 이용한 후판소재 용접 및 응용 (A weldability of thick materials with 10kW fiber laser and its application)

  • 이목영;류충선;장웅성;박서정
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.177-180
    • /
    • 2007
  • The laser welding process was effective way to join the metals, because of the high productivity, the low distortion and the good weld quality. The fiber laser used the double-clad fiber architecture, the single element diode laser and the fully-spliced side pumping. It has the advantages in the views of the energy conversion efficiency, the beam quality, the robustness and the mobility. Recently, the thick material was welded with the high power laser in ship building or construction industry owing to the super bright fiber laser. In this study, we introduced the characteristics of high power fiber laser and its welding performance of thick gauge materials.

  • PDF

섬유보강 순환잔골재 콘크리트의 공학적 특성 및 수축균열저감특성에 관한 실험적 연구 (An Experimental Study on the Properties of Engineering and Shrinkage Cracking Reduction of Fiber Reinforced Concrete Using Recycled Fine Aggregate)

  • 김규용;남정수;김무한;이도헌;송하영
    • 한국건설순환자원학회논문집
    • /
    • 제4권3호
    • /
    • pp.82-89
    • /
    • 2009
  • 최근 국내에서는 건설생산현장에서 순환골재 및 이를 활용한 순환골재 콘크리트의 사용을 적극적으로 도모하기 위하여 순환골재 콘크리트의 제조기술에 관한 다양한 연구개발이 활발하게 이루어지고 있으나 순환굵은 골재에 비하여 순환잔골재에 관한 적용 및 연구는 미흡한 실정이다. 따라서 본 연구에서는 순환잔골재를 사용한 환경부하저감형 콘크리트의 공학적 성능 및 수축균열저감 성능 향상을 위한 섬유보강 순환잔골재 콘크리트의 공학적 특성 및 수축균열특성에 관하여 실험 실증적으로 비교 검토함으로써 향후 환경부하 저감형 섬유보강 순환잔골재 콘크리트의 개발을 위한 기초자료를 제시하고자 한다. 그 결과, 천연잔골재에 비해 순환잔골재의 사용으로 콘크리트의 균열면적이 증가하였으며, W/C비가 증가할수록 균열면적도 증가하는 것으로 나타났다. 또한 섬유종류중 PVA 및 Nylon섬유를 혼입한 시험체의 균열면적이 가장 적은 것으로 나타났으며, 섬유혼입율이 증가할수록 균열면적이 감소하는 것으로 나타나 섬유혼입에 의한 균열저감성능을 확인할 수 있었다.

  • PDF