• 제목/요약/키워드: Fiber Ratio

검색결과 2,432건 처리시간 0.032초

폴리프로필렌 섬유 보강 EVA 콘크리트의 압축강도 및 내구성 (The Compressive Strength and Durability Properties of Polypropylene Fiber Reinforced EVA Concrete)

  • 남기성;성찬용
    • 한국농공학회논문집
    • /
    • 제57권4호
    • /
    • pp.11-19
    • /
    • 2015
  • The important properties of EVA (ethylene vinyl acetate) redispersible polymer was waterproof, densification of internal pore space of concrete and ball bearing and micro filler. Also, the significant role of polypropylene(PP) fiber was crack control and blockade of movement for deterioration factors. The most studies for EVA were limited in the field of mortar and PP fiber reinforced concrete had been studied in the state of being restricted unit water content, rich mix and mixing much of the fiber without considering construction site. Therefore, the control mix design were applied in ready mixed concrete using 10 % fly ash of total cement weight used in batch plant. On the basis of control mix design, EVA contents ranging from 0 % to 10 % of total cement weight and PP fiber contents ranging from 0 % to 0.5 % of EVA concrete volume were used in the mix designs. The results showed the maximum compressive strength value was measured at EVA 5.0 % and PP fiber 0.1 %, the minimum water absorption ratio was at EVA 10 % and PP fiber 0 %, the durability factor for freezing and thawing resistance was at EVA 5.0 % and PP fiber 0.3 % and the minimum weight reduction ratio of resistance to sulfuric acid attack was at EVA 10 % and PP fiber 0.5 % after curing age 42days. Meanwhile, From these results, PP fiber reinforced EVA concrete would be very benefit, if each optimal mix types were used in hydraulic structures, underground utilities and agricultural structures.

전기저항 측정법을 이용한 탄소섬유/기지 간 계면에서의 섬유 미끌림 정도 측정방법 (Measurement of Electrical Resistance Method in Characterizing the Slip ratio of Carbon fiber/Matrix at the Interface)

  • 권동준;왕작가;구가영;박종만
    • Composites Research
    • /
    • 제25권6호
    • /
    • pp.205-210
    • /
    • 2012
  • 전기저항 측정법을 이용하여 단일 탄소섬유의 인장 실험을 실시하였다. 탄소섬유의 전도성을 이용하여 인장하중에 따른 신율과 전기저항 변화도간의 관계를 연구하였다. 섬유 인장 과정동안에 일정 신율 거리상 응력과 전기저항 변화율간의 상관관계를 통계적으로 정리하였다. 결과에 대해 추세선을 그어 섬유의 변형에 따른 거동 모델을 구성하였다. 프레그먼테이션 시편을 이용하여 인장 실험에 따른 인장 응력이 재료 내부로 전달되면서, 시편 내부 탄소섬유에도 인장 응력이 가해져 기지보다 섬유가 먼저 파괴되었다. 이 경우 탄소섬유의 전기저항 변화도를 측정한 결과 값을 탄소섬유의 거동 모델에 대입하여 프레그먼테이션 시편 내부에 있었던 탄소섬유의 거동을 분석할 수 있었다. 탄소섬유의 인장 신율을 예측하고 프레그먼테이션 시편의 실제 신율을 비교하여 섬유와 기지 사이에 발생된 섬유 미끌림 정도를 확인하였다. 섬유 미끌림 정도의 수치가 클 경우, 기지와 섬유 간 계면 상태가 약한 접합의 상태였다. 이러한 결과를 확인하기 위해서 접착일 평가법을 이용하였으며, 두 실험법의 결과, 동일한 경향임을 확인하였다.

CSA 팽창재를 혼입한 강섬유 보강 콘크리트의 역학적 성능 및 균열 저항성능 평가 (Evaluation of Mechanical Properties and Crack Resistant Performance in Concrete with Steel Fiber Reinforcement and CSA Expansive Admixture)

  • 최세진;박기태;권성준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.75-83
    • /
    • 2014
  • 콘크리트의 취성파괴를 방지하기 위해 강섬유 보강재는 효과적인 복합재료이다. 그러나 시멘트 사용량이 많아지면 건조수축이 증가하고 이로 인해, 강섬유 보강재의 연성증가 효과가 제한될 수 있다. 팽창재를 사용한 콘크리트 내부의 강섬유 보강재는 화학적 프리스트레싱 효과가 발생하여 강섬유 보강효과를 증가시킬 수 있다. 본 연구에서는 CSA 팽창재와 강섬유 보강재를 혼입하여 콘크리트의 역학적인 특성을 분석하였다. 체적비 1~2%의 강섬유 보강재와 시멘트 중량의 10%의 CSA 팽창재를 혼입하였으며, 다양한 역학적 특성과 휨거동을 분석하였다. 강섬유 보강재를 혼입한 CSA 콘크리트는 인장강도와 초기균열강도의 증가를 나타냈으며, 균열후의 파괴에너지 증가와 같은 연성거동을 뚜렷하게 나타내었다. 적절한 팽창재 사용과 최적의 강섬유 보강재의 혼입률이 도출된다면 이들의 상호작용은 콘크리트의 취성을 더욱 효과적으로 제어할 수 있다.

단계적 다섬유 Fragmentation 시험법을 이용한 복합재료의 계면적 특성에 대한 새로운 평가방법 (A New Evaluation Method for Interfacial Properties of Composites using the Gradual Multi-Fiber Fragmentation Test)

  • 박종만;김진원
    • Composites Research
    • /
    • 제12권2호
    • /
    • pp.10-25
    • /
    • 1999
  • Fragmentation 시험법에 의한 섬유상 복합재료의 계면적 특성에 대한 새로운 평가방법이, 순차적으로 섬유간의 간격이 변하게 된 단계적 다섬유 복합재료를 사용하여 제시되었다. 섬유간의 간격이 증가함에 따라, 부서진 섬유들의 형상비는 감소하였으며, 섬유와 기지간의 계면전단강도는 증가함을 보여주었다. 섬유간 거리의 역수를 취했을 때에, 형상비와 계면전단강도 모두가 포화되는 값을 보여주었다. 이것은 단계적 다섬유 복합재료가 형상비에서의 상한값을 나타내고, 계면전단강도에서 하한값을 보여준다는 것을 의미한다. 이 fragmentation 시험법은 복합재료의 평가에 새로운 방법이 될 수 있다. 왜냐하면, 이 두 한계값의 차이를 줄이는 것이 복합재료의 강화에 효과적이기 때문이다. 또한, 섬유 파괴점 부근에서의 섬유응력 분포와 위의 결과를 관련시키기 위해 탄송-소성 유한요소 해석이 행해졌다. 단계적 다섬유 복합재료 시험에서 얻어진 한계값은 그룹형태의 다 섬유 파괴에 의해 야기된 응력집중과 밀접하게 관련되어 있다는 것이 입증되었다.

  • PDF

INVESTIGATION OF A STRESS FIELD EVALUATED BY ELASTIC-PLASTIC ANALYSIS IN DISCONTINUOUS COMPOSITES

  • Kim, H.G.
    • International Journal of Automotive Technology
    • /
    • 제8권4호
    • /
    • pp.483-491
    • /
    • 2007
  • A closed form solution of a composite mechanics system is performed for the investigation of elastic-plastic behavior in order to predict fiber stresses, fiber/matrix interfacial shear stresses, and matrix yielding behavior in short fiber reinforced metal matrix composites. The model is based on a theoretical development that considers the stress concentration between fiber ends and the propagation of matrix plasticity and is compared with the results of a conventional shear lag model as well as a modified shear lag model. For the region of matrix plasticity, slip mechanisms between the fiber and matrix which normally occur at the interface are taken into account for the derivation. Results of predicted stresses for the small-scale yielding as well as the large-scale yielding in the matrix are compared with other theories. The effects of fiber aspect ratio are also evaluated for the internal elastic-plastic stress field. It is found that the incorporation of strong fibers results in substantial improvements in composite strength relative to the fiber/matrix interfacial shear stresses, but can produce earlier matrix yielding because of intensified stress concentration effects. It is also found that the present model can be applied to investigate the stress transfer mechanism between the elastic fiber and the elastic-plastic matrix, such as in short fiber reinforced metal matrix composites.

옹벽 배면토체 적용을 위한 단섬유 보강토의 전단강도 특성 (Shear Strength Characteristics of Short-fiber Reinforced Soil for the Application of Retaining Wall Backfill)

  • 박영곤;차경섭;장병욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.73-78
    • /
    • 2003
  • As a fundamental study to develop the retaining wall of new type, short-fibers are mixed with soils and a series of compaction tests and triaxial compression tests for short-fiber reinforced soils are performed. From the results of compaction tests, optimum moisture content is increased and maximum dry unit weight is decreased with fiber mixing ratio. When 60mm fibrillated fiber of 0.2$\%$ mixing ratio is added to SM soil, strength increment of short-fiber reinforced soil is above 1.2 times compared to soil only. Strength increment shows maximum value for composite reinforced soil, namely, soil+short-fiber+planar reinforcement. But in case of mixing with ML soil and short-fiber, the strength of short-fiber reinforced soil is nearly the same as soil only. Internal angle of short-fiber reinforced soil is increased about $2\~3$ degrees and cohesion is also increased above 10kPa compared to soil only. Therefore, it is judged that short-fiber is a good material to strengthen the soil.

  • PDF

잔골재율에 따른 PVA섬유를 사용한 고인성 콘크리트의 공학적 특성에 관한 실험적 연구 (An Experimental Study on the Engineering Properties of Ductile Concrete Using PVA Fibers with Sand-Aggregate Ratio)

  • 민원규;황문규;윤현도;남재현;이상수;송하영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.389-392
    • /
    • 2006
  • In this study, I examined hardening and non-hardening of the DFRCC (Ductile Fiber Reinforced Cementitious Composites) according to sand-aggregate ratio and the diameter of PVA fiber to develope PVA fiber reinforced concrete with the feature of DFRCC. As a result of this study, the fresh properties of DFRC is similar regardless of sand-aggregate ratio. The bending stress of DFRC also increased as the sand-aggregate ratio increased. And the bending stress-displacement was the most stable when the PVA $100{\mu}m$ was used regardless of sand-aggregate ratio.

  • PDF

An Experimental Study on the Evaluation of Shear Performance of PVA Fiber Reinforced RC Deep Beam with High Strength Headed Rebar

  • Kim, Seunghun;Lee, Kyuseon;Lee, Yongtaeg
    • Architectural research
    • /
    • 제19권4호
    • /
    • pp.109-115
    • /
    • 2017
  • This study is done to evaluate how existence of shear-span ratio and shear reinforcing bar effects on shear performance from through shear experiment using PVA fiber reinforced ferroconcrete building. Ratio of shear-span was set 1, 1.7, and arrangement of shear reinforcing bar was set with KCI2012 regulation. In result, subject with less shear-span ratio, and shear reinforcing bar with arrangement of bar shows high stiffness. Subjects with high shear-span ratio show large difference depending on existence of shear reinforcing bar. Therefore, theoretical shear strength followed by CEB code underestimates experimental shear strength by 43.9%. Shear strength of the deep beam with headed bars is more affected by the bearing strength of head than the bond strength of bar.

탄소섬유 복합재료의 AE 특성에 관한 연구 (A Study on the AE Characteristics of the Carbon Fiber Composite Material)

  • 옹장우;이영신;심봉식;지용관;주영상
    • 대한기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.105-114
    • /
    • 1989
  • 본 연구에서는 카본/에폭시 프리프렉으로부터 제작된 적층판을 사용하여 인장시험시 발생하는 AE특성과 파괴거동을 비교 검토하고 이들을 통하여 탄소섬유 복합재료의 파손특성과 AE법의 유용성을 규명하고자 한다.

Analysis of Polarization Properties of Optical Isolator for Fiber Laser

  • Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil;Cho, Kyung-Jae;Kang, Sung-Hak
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권6호
    • /
    • pp.241-244
    • /
    • 2011
  • An isolator transmits light in the forward direction and blocks light from passing in the reverse direction. It is regarded an essential optical component in medical, industrial, and research lasers for blocking reflection beams that cause optical damage and noise. It is also used as a communicative light intensifier to expand the lifespan of devices and enhance transmission quality. This study analyzed the characteristics of the core components in the construction of a polarization-independent isolator, namely, the walk-off polarizer and the Faraday rotator. Measurement of the extinction ratio of the resultant walk-off polarizer revealed that the ratio between the vertical and horizontal rays was 1,050:1 with a laser output of 0.032 W and 1,010:1 with a laser output of 2.68 W, thus presenting ratios similar to 1,000:1. In addition, the walk-off polarizer and Faraday rotator constructed in this study were used to compare output changes according to changes in power of input light and to check the penetration ratio. Results from the study presented variations in output value according to changes in power of input light. However, the average penetration ratio remained relatively consistent (~81.4%).