Study on EMI filter for Eliminating Noise from Pole Transformer for PLC (전력선 통신을 위한 저압변압기에서 발생되는 EMI 노이즈 제거 필터 관한 연구)

  • Kim, Young-Sung;Jeong, Jung-Il;Kim, Jae-Chul;Cho, Sung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.533-534
    • /
    • 2007
  • This paper investigates impulsive noise from a pole transformer in low voltage distribution system for power line communication. EMI noise from the pole transformer is indicated from the experiment. The noise has certain characteristics because it is caused by partial discharge. The noise level is above -35dBm without a filter. Therefore, the filter which is made of ferrite is used in order to eliminate the noise. the noise filters should be applied to both the phase line and the neutral line. Otherwise, It is likely to have little overall impact on elimination of noises. the performance of filter is verified with various experiments. In conclusion, the equivalent circuit of power line communication including noise source is described as a lumped circuit.

  • PDF

The AC Chopper LED Driving System Using The Y Type Balancing Transformer (Y형 밸런싱 트랜스포머를 적용한 AC초퍼 LED 구동 시스템)

  • Kim, Jin-Gu;Yoo, Jin-Wan;Kim, Yong-Ha;Park, Chong-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.22-29
    • /
    • 2015
  • The AC-LED driving system which is connected directly to alternative current source is suitable for commercialization because of it's simple structure and low cost. However, it requires additional circuits compensating for current differences between the parallel connected LED strings. In this paper, we proposed the circuit compensating for current error of the three LED strings using the Y type balancing transformer. The proposed Half-bridge AC Chopper LED driving system used the ferrite material's balancing transformer. at the same time, it is able to dimming control. The proposed system is applied to 80W AC-LED module consist of three parallel strings. Experiment results present that Power factor and THD measured with power analyzer are 0.958 and 26.473% respectively satisfied with IEC61000-3-2 harmonics standard.

Brightness Characteristic as a Change of Antena Parameter on Electrodeless Fluorescent Lamp (무전극 램프의 안테나 파라미터 변화에 따른 휘도특성)

  • Yang, Jong-Kyung;Choi, Gi-Seung;Pack, Gwang-Hyeon;Choi, Yong-Sung;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.164-166
    • /
    • 2004
  • In Recent, it became necessary to develope the technology about electrodeless fluorescent lamp according to demand of the electodeless fluorescent lamp system that used higher efficiency and advantage of long-lifetime. Especially, in the electordeless fluorescent lamp which used H-mode, efficiency of lamp is decided from matching parameter of antena and inverter, so it is of the utmost importance to design antena and inverter. Therefore, this paper used a transformer principle for an efficiency rising of electrodeless fluorescent lamp and interpreted an equivalent circuit, and confirmed a luminance characteristic by ferrite change of antenna and change of coil turns. Also, this paper used the thermoelectric element which can let you cool ferrite and antenna and confirmed the luminance characteristic along a change of ferrite and an antenna temperature.

  • PDF

A Study on measuring the Initial Permeability of Magnetic Powder considered Demagnetizing factors (반자장계수를 고려한 자성분말의 초투자율 측정에 관한 연구)

  • Jun, Hong-Bae;Heo, Jin;Kim, Chul-Han;SaGong, Geon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.86-90
    • /
    • 2000
  • In this study, A equipment for measuring the initial permeability of soft-ferrite powder was developed by using a differential transformer coil, and was investigated demagnetizing factors. To measure the initial permeability of magnetic ceramic powder is cumbersome since there are not any measuring equipment and method. Magnetic powder is currently used for a magnetic fluid and microwave absorber materials, and the initial permeability of the magnetic powder is very important to be evaluated a powder for some applications.

  • PDF

Finite Element Analysis of Transformer for Forward Converter (Forward Converter 용 변압기의 유한요소 해석에 관한연구)

  • Kim, H.S.;Kim, B.T.;Kwon, B.I.;Park, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.49-51
    • /
    • 1997
  • This paper deals with analysis of high frequency transformer for forward converter using the finite element method and circuit analysis. Finite element analysis considering magnetic nonlinearity of ferrite core and circuit analysis are utilized when converter switch(FET) is on and off, respectively. As a result, the primary current and load current of a forward converter are obtained under the various load conditions.

  • PDF

The Trend Analysis of Technology Development for Auxiliary Power Supply of Electric Vehicle (전동차 보조전원장치의 기술개발 동향 분석)

  • Han, Young-Jae;Jo, Jeong-Min;Lee, Jin-Ho;Lee, Chul-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7957-7963
    • /
    • 2015
  • R&D trend for Auxiliary Power Supply(APU) of electric vehicle can be well understood by analyzing patents at home and abroad. Based on this trend analysis, domestic technology development direction is proposed. To get technique trend, patents of Korea, Japan, Europe and America published until February of 2014 are analyzed by WIPS DB. First, power converter and transformer two big category are classified. Power converter can be classified into resonant DC to DC converter and resonant Half bridge inverter; transformer can be classified into high frequency transformer, ferrite transformer and matching transformer. By analyzing R&D trend of different counties, companies and years, specific technology needed to be developed and trend of technology can be accurately grasped.

Electromagnetic Properties of Mo-Zn ferrite for Low Voltage and High Current Transformer Application With Using Multi cores (다중 코어를 이용한 저전압, 대전류 변압기용 Mn-Zn ferrite의 전자기적 특성)

  • Kim, Hyun-Sik;Lee, Hae-Yon;Kim, Jong-Ryung;Huh, Jeong-Seob;Lee, Jun-Hui;An, Yong-Woon;Oh, Young-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.294-295
    • /
    • 2005
  • 다중 코어를 이용한 대전류 변압기용 Mn-Zn ferrite를 제조하고 전자기적 특성을 분석하였으며, 제조된 자심재료를 이용하여 변압기를 제조하고 전원장치에 탑재하여 효율특성을 분석하였다. ZnO의 몰비가 증가할수록 혼합 스피넬의 형성을 통한 보아 자자의 증가로 인해 투자율은 증가하고 상대적으로 전력손실이 감소하여 $Fe_2O_3$ : MnO : ZnO = 53 : 36 : 11 mo\% 일 때 가장 우수한 특성을 나타냈고, 열처리 공정의 승온 과정에서부터 산소 분압을 제어하고 최적의 대기압 상수를 산출함으로써 Zn-loss 현상을 최소화하여 ZnO 11 mol%, 대기압 상수 7.7일 때 투자율 2350, 밀도 4.9 $g/cm^3$, 비저항 480 ${\Omega}cm$, 300 mT의 최대 자속 밀도 특성을 갖는 우수한 자심 재료를 개발하였다. 그리고 최소 손실 온도를 $90^{\circ}C$ 이하로 감소시켰으며 100 kHz에서 250 $kW/m^3$의 낮은 전력손실을 나타냈다. 또한 개발된 자심재료를 이용하여 제조된 전원장치는 30~80A의 출력 전류에서 85% 이상의 고효율을 얻었다.

  • PDF

Design and Implementation of Flux-Driven Waveguide Ferrite Phase Shifters (자속밀도 제어형 페라이트 도파관 변위기 설계 및 제작)

  • 김동석;박동철;이용희;김윤명
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.3 no.1
    • /
    • pp.3-10
    • /
    • 1992
  • Flux-drive waveguide phase shifter is designed by twin-slab model. Measured differential phase shifts are smaller than the theoretical values by 8-9 percents. Measured insertion loss and VSWR of the phase shifter using TT73-2200 ferite are less than 0.45dB and 1.25 respectively, within pass band. The phase shifter using double-setup transformer shows wider bandwidth characteristics. Finally the reduced-height waveguide phase shifter using TT3-2900 ferrite shows very efficient suppression of higher-oreder modes.

  • PDF

A Wireless Energy Transmission For Capsule Endoscopes (캡슐형 내시경 구동을 위한 무선 에너지 전송)

  • Seo, Min-Sung;Ko, Young-Suk;Park, Shi-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.80-85
    • /
    • 2008
  • Capsule endoscopes generally use primary cells as a power source due to its limited space. However, the primary cells have several limitations such as high cost, limited power and no reuse. To solve these problems, a new wireless energy transmission method is proposed. The proposed approach uses air-gap transformer concepts and LC resonance to transmit energy from transmitter(primary side) to capsule endoscopes(secondary side). The ferrite core with 3-axis winding is used to increase energy transfer efficiency regardless of direction and location. The experimental results show that the proposed method stably supplies 30mW power to secondary circuit.

Variation of Magnetic Properties of Cu-Zn-Mg Ferrites with Various Compositions and Sintering Temperatures (Cu-Zn-Mg ferrite의 조성성분 및 소결온도에 따른 자기적 특성변화 연구)

  • Koh, Jae-Gui
    • Korean Journal of Materials Research
    • /
    • v.13 no.6
    • /
    • pp.365-368
    • /
    • 2003
  • Small amounts of additives such as mol % 0.13 NiO and mol % 0.01 $CaCO_3$were added to Cu-Zn-Mg ferrites. Basic composition of the Cu-Zn-Mg ferrites was $Cu_{Cu}$X/$Fe_{0.054}$ /$Zn_{0.486}$$Mg_{0.407}$ $Fe_{1.946}$ $O_4$(group A) and $Cu_{0.263}$$Fe_{0.027}$ $Zn_{0.503}$ $Mg_{0.262}$ $Fe_{1.973}$ $O_4$(group B). Specimens were sintered at different temperatures (1010, 1030, $1050^{\circ}C$) for 2 hours in air followed by an air cooling. Then, effects of various composition and sintering temperatures on the microstructure and the magnetic properties such as inductions, coercive forces, and initial permeabilities of the Cu-Zn-Mg ferrites were investigated. The average grain size increased with the increase of sintering temperature. The magnetic properties obtained from the aforementioned Cu-Zn-Mg ferrite specimens were 1,724 gauss for the maximum induction, 1.0 oersted for the coercive force, and 802 for the initial permeability. These magnetic properties indicated that the specimens could be utilized as the core of IFT (intermediate frequency transformer) and antenna in the amplitude modulation.