• 제목/요약/키워드: Fenton sludge

검색결과 23건 처리시간 0.022초

전기펜톤공정을 이용한 석유화학공장 폐활성슬러지의 감량화 가능성 평가 (A study on reduction of excess sludge in activated sludge system from a petrochemical plant using electro fenton process)

  • 정종민;김경일;심나타리아;박철희;이상협
    • 상하수도학회지
    • /
    • 제23권5호
    • /
    • pp.669-678
    • /
    • 2009
  • The reduction of excess activated sludge from petrochemical plant was investigated by the electro fenton (E-Fenton) process using electrogenerated hydroxyl radicals which lead to mineralization of activated sludge to $CO_2$, water and inorganic ions. Factors affecting the disintegration efficiency of excess activated sludge in E-Fenton process were examined in terms of five criteria: pH, $H_2O_2/Fe^{2+}$ molar ratio, current density, initial MLSS (mixed liquid suspended solids) concentration, $H_2O_2$ feeding mode. TSS total suspended solid and $TCOD_{cr}$ reduction rate increased with the increasing $H_2O_2/Fe^{2+}$ molar ratio and current density until 42 and $6.7 mA/cm^2$, respectively but further increase of $H_2O_2/Fe^{2+}$ molar ratio and current density would reduce the reduction rate. On the other hand, as expected, increasing pH and initial MLSS concentration of activated sludge decreas TSS and $TCOD_{cr}$ reduction rate. The E-Fenton process was gradually increased during first 30 minutes and then linearly proceed till 120 minutes. The optimal E-Fenton condition showed TSS reduction rate of 62~63% and $TCOD_{cr}$ (total chemical oxygen demand) reduction rate of 55~56%. Molar ratio $H_2O_2/Fe^{2+} = 42$ was determined as optimal E-Fenton condition with initial $Fe^{2+}$ dose of 5.4 mM and current density of $6.7{\sim}13.3 mA/cm^2$, initial MLSS of 7,600 mg/L and pH 2 were chosen as the most efficient E-Fenton condition.

정유 공장에서 발생된 폐수 슬러지의 최적 감량화 방안 연구 (Study of optimal reduction plan for wastewater sludge generated from oil refinery)

  • 최재우;정종민;심나탈리아;이상협;박철희
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.395-406
    • /
    • 2010
  • In this study, anaerobic digestion, electro-oxidation and electro-fenton oxidation processes were investigated to reduce oily refinery sludge. Anaerobic digestion process was not suitable for oily activated sludge reduction because of characteristics itself and, as experimental results revealed, reduction efficiency was low for electro-oxidation process. However, 40% total suspended solid reduction of oily activated sludge was obtained by electro-fenton oxidation process, operating at pH=1, 0.5 A and $Fe^{2+}$:$H_2O_2$ ratio = 1:30. In addition, higher reduction efficiency was obtained as reaction time was increased (30, 60, 90, 120 min) despite of low $H_2O_2$ concentration. From the results, it has been investigated that electro-fenton oxidation is efficient process for oily activated sludge reduction.

펜톤산화 공정에서 발생하는 슬러지의 재활용 방안 (Methodology Development for the Reuse of Sludge Generated from Fenton's Oxidation Process)

  • 구태완;조순행;최영수
    • 대한환경공학회지
    • /
    • 제22권6호
    • /
    • pp.1083-1091
    • /
    • 2000
  • 본 연구는 펜톤산화 공정에서 발생되는 펜톤슬러지를 응집제와 펜톤산화 공정에서의 촉매로 재이용할 수 있는지 여부를 검토하여 고농도의 난분해성 유기물질을 함유한 침출수를 효과적이고 경제적으로 처리할 수 있는 기술을 개발하는데 그 목적을 두었다. Batch-Scale 연구 결과 펜톤슬러지를 응집제와 펜톤산화 공정의 촉매제로 혼합사용하여 응집 공정과 펜톤산화 공정에 적용할 경우 약품만을 사용하는 경우보다 응집제의 사용량을 50%, 펜톤산화 공정의 촉매제 사용량을 50% 감소시킬 수 있었으며, 응집 공정과 펜톤산화 공정에서 발생되는 슬러지의 발생량도 감소시킬 수 있는 것으로 조사되었다. 실험실 규모의 연속식 처리 실험을 수행한 결과 펜톤슬러지를 응집제로 재이용함으로써 평균 8.5% 정도 유기물 제거효율이 증가하였으며, 슬러지의 발생량은 35% 감소하는 것으로 조사되었다. 또한 펜톤슬러지를 펜통촉매제로 재이용함으로써 유기물 제거면에서 평균 5.3% 정도 효율이 증가하였으며, 슬러지의 발생량은 14% 정도 감소하는 것으로 조사되었다. 이상의 결과로 펜톤산화 공정에서 발생하는 슬러지의 재이용은 약품 비용이나 슬러지 처리 비용을 절감시킬수 있을 것으로 결론지을 수 있다.

  • PDF

변형 펜턴산화법을 이용한 유기폐수의 처리 (Organic Wastewater Treatment Using Modified Fenton's Oxidation)

  • 김지연;윤태일;박세진
    • 청정기술
    • /
    • 제5권1호
    • /
    • pp.49-61
    • /
    • 1999
  • 펜턴산화는 산화력이 매우 우수한 $OH{\cdot}$을 생성하여, 난분해성 유기폐수의 생분해성을 향상시킬 수 있으므로 다양한 용존 유기오염물질을 함유하고 있는 산업폐수의 처리에 널리 이용되고 있지만, 철염과 과산화수소 등의 약품비용과 Sludge 처분비용 때문에 현재로서는 그리 경제적인 공정이라고 볼 수 없다. 본 연구에서는 펜턴산화의 약품비용을 줄이고, 적은 약품으로 처리효율을 향상시키기 위한 변형 펜턴산화법과 혼합한 슬러지 재이용의 가능성을 제시하고자 하였다. 본 연구는 펜턴산화에서 사용되는 철염용액에 NaOH용액을 첨가하였더니 철염용액의 폭발적인 반응을 보고 이를 펜턴산화에 응용하게 되었다. 본 연구에서 제안하는 변형 펜턴산화 공정이란 펜턴산화에서 사용되는 철염용액에 NaOH를 넣어 적정 pH로 조정하여, 수산화물을 형성시킨 후 처리대상 시료에 주입하여 과산화수소와 반응시켜 $OH{\cdot}$을 형성시키는 방법이다. 이 때 대상시료로서는 대표적인 오염물질인 페놀을 사용하였고 자연수의 이온강도와 유사한 수준으로 맞추기 위하여 $NaHCO_3$를 적량 첨가하여 페놀 인공폐수를 조제하였다. 이를 이용하여, DO의 영향, 이온강도의 영향, 과산화수소 주입횟수에 따른 영향을 알아보았다. 또한, 침출수와 염색폐수에 적용시켜 본 결과 기존의 펜턴산화보다 더 나은 처리효율을 얻을 수 있었으며, 변형 펜턴산화법과 슬러지 반송을 조합하여 실험한 결과 철염을 50%만 주입하여도 기존의 펜턴산화와 유사한 수준의 처리효율을 얻을 수 있었다.

  • PDF

폐수처리슬러지의 재활용기술개발 및 경제성 평가 -B염색조합을 중심으로- (Reuse Technology Development and Economic Evaluation of Dyeing Wastewater Treatment Sludge)

  • 임재호;이정연
    • 자원리싸이클링
    • /
    • 제9권1호
    • /
    • pp.36-43
    • /
    • 2000
  • 본 연구는 B 염색조합 공동폐수처리장의염색폐수 처리공정중 Fenton 공정에서 발생되는 무기슬러지의 처리 및 재활용에 관한 연구로서, Pilot plant에 의하여 재용해철($Fe^{3+}$)과 FECL의 혼합용액을 사용한 연속식 산화실험 결과, 처리수의 $COD_{cl}$ 는 대략 100 mg/l이하였으며 이때 $COD_{cl}$제거율은 78.9%로 $H_2O_2/Fe^{total}$가 대략 1.5범위에서 최적치를 나타내었다. 슬러지의 용해공정 후에 배출되는 2차 슬러지에 대하여 3성분을 측정하여 1차 슬러지와 비교해 볼 때 회분은 약 85%가 감소되었으며, 건조기준 총 슬러지는 약 65%의 감량율을 나타내었고, 슬러지의 속의 철염의 재용해율은 대략 90~95%정도였다 슬러지 재활용공정의 예상투자비용은 시설용량 30,000 $m^3$/d/d 기준으로 약 3.5억원이 소요되며, 예상운영비는 하루에 약 130만원(연간 4.2억원)의 절감을 예상할 수 있으며, 투자비에 대한 이자비용을 감안하면 설비투자비용에 대한 투자자본금 회수기간(PP)은 약 10.5개월이 필요하고, 회계적이익율(ARR)은 179%, 순현재가치(NPV)는 7.92억원, 내부수익률(IRR)은 약 110%로 충분한 투자가치가 있는 것으로 판명되었다.

  • PDF

MBT 폐수의 생분해성 평가 (Evaluation on the Biodegradability of the MBT Wastewater)

  • 임지영;박정환;김진한
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.86-92
    • /
    • 2016
  • 본 연구는 가황촉진제 제조공정에서 발생되는 MBT 폐수의 생물학적 처리가능성을 평가하였다. MBT 폐수는 미생물 활동을 저하시키기 때문에 생물학적으로 처리가 불가능하였지만, 7일의 순응기간을 거쳐 약 10%의 COD가 제거되었다. MBT 폐수의 화학적 전처리를 위한 최적조건은 pH 3.5, 2시간동안 교반 후 $Fe^{3+}$를 주입하여 펜톤산화를 한 경우였다. 또한, 펜톤처리 된 MBT 폐수를 제지폐수와 혼합하여 활성슬러지공정에서 처리했을 경우 MBT 폐수의 COD가 약 20% 제거되었다.

소규모 쓰레기 매립장 침출수의 효율적인 처리 방안에 관한 연구 (Effective Treatment System for the Leachate from a Small-Scale Municipal Waste Landfill)

  • 조영하;권재현
    • 한국환경보건학회지
    • /
    • 제28권1호
    • /
    • pp.51-65
    • /
    • 2002
  • This study was carried out to apply some basic physical and chemical treatment options including Fenton's oxidation, and to evaluate the performances and the characteristics of organic and nitrogen removal using lab-scale biological treatment system such as complete-mixing activated sludge and sequencing batch reactor(SBR) processes for the treatment of leachate from a municipal waste landfill in Gyeongnam province. The results were as follows: Chemical coagulation experiments using aluminium sulfate, ferrous sulfate and ferric chloride resulted in leachate CO $D_{Cr}$ removal of 32%, 23% and 21 % with optimum reaction dose ranges of 10,000~15,000 mg/$\ell$, 1,000 mg/$\ell$ and 500~2,000 mg/$\ell$, respectively. Fenton's oxidation required the optimum conditions including pH 3.5, 6 hours of reaction time, and hydrogen peroxide and ferrous sulfate concentrations of 2,000 ~ 3,000 mg/$\ell$ each with 1:1 weight ratio to remove more than 50% of COD in the leachate containing CO $D_{Cr}$ between 2,000 ~ 3,000 mg/$\ell$. Air-stripping achieved to remove more than 97% of N $H_3$-N in the leachate in spite of requiring high cost of chemicals and extensive stripping time, and, however, zeolite treatment removing 94% of N $H_3$-N showed high selectivity to N $H^{+}$ ion and much faster removal rate than air-stripping. The result from lab-scale experiment using a complete-mixing activated sludge process showed that biological treatability tended to increase more or less as HRT increased or F/M ratio decreased, and, however, COD removal efficiency was very poor by showing only 36% at HRT of 29 days. While COD removal was achieved more during Fenton's oxidation as compared to alum treatment for the landfill leachate, the ratio of BOD/COD after Fenton's oxidation considerably increased, and the consecutive activated sludge process significantly reduced organic strength to remove 50% of CO $D_{Cr}$ and 95% of BO $D_{5}$ . The SBR process was generally more capable of removing organics and nitrogen in the leachate than complete-mixing activated sludge process to achieve 74% removal of influent CO $D_{Cr}$ , 98% of BO $D_{5}$ and especially 99% of N $H_3$-N. However, organic removal rates of the SBR processes pre-treated with air-stripping and with zeolite were not much different with those without pre-treatment, and the SBR process treated with powdered activated carbon showed a little higher rate of CO $D_{Cr}$ removal than the process without any treatment. In conclusion, the biological treatment process using SBR proved to be the most applicable for the treatment of organic contents and nitrogen simultaneously and effectively in the landfill leachate.e.

과산화수소 산화처리에 의한 정수슬러지의 감량화 (The Reduction of Waterworks Sludge by Hydrogen Peroxide Treatment)

  • 권재현;김영도;박기영;이석헌;김일규
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.123-130
    • /
    • 2007
  • The effects of hydrogen peroxide treatment on the reduction of waterworks sludge were investigated in this study. Sludge treated by peroxidation $H_2O_2$ oxidation) was dewatered using a pressure filter at 3atm. It was observed that $H_2O_2$ treatment at the acidic condition significantly reduce both cake water content and specific resistance to filtration (SRF), indicating the enhancement of dewaterability and filterability. The filterability by hydrogen peroxide treatment at pH 3.5 was better than acidic treatment and became comparable with polymer conditioning. The sludge filterability evaluated by SRF was optimal at a dose 2ml $H_2O_2$/sludge($0.02g\;H_2O_2/gTS$) after adjusting of pH to 3.5. The $H_2O_2$ oxidation at pH 3.5 also produced even more dewatered cake when compared with polymer conditioning. The reduction rate of sludge mass at an optimal condition showed 34% compared with untreated sludge. The effects of peroxidation on sludge properties including zeta potential, bound water and particle size were also evaluated. Peroxidation at the acidic condition reduced both bound water and zeta potential. By $H_2O_2$ combined with sulfuric acid leached iron caused Fenton's reaction, which showed a potential to significantly reduce the amount of solids mass and to produce more compact cake with higher filterability.

펜톤산화와 오존산화 조합에 따른 염색폐수의 유기물질 및 색도 처리효율 비교 평가에 관한 연구 (Eveluation of Comparable Removal Efficiency of Organics and Color for the Dyeing Wastewater by Fenton Oxidation and Ozonation)

  • 김선희;이상호
    • 상하수도학회지
    • /
    • 제18권6호
    • /
    • pp.778-784
    • /
    • 2004
  • Dyeing wastewater contains recalcitrant organics which can not be easily treated by conventional biological treatment. Therefore it has to be treated by other advanced oxidation process in order to remove COD and Color more efficiently. Fenton oxidation process is one of the most commonly applied processes in removal of COD and color for the dyeing wastewater. However it increase the treatment cost and the production of sludge by the use of the excessive chemical reagent. Ozonation is not suitable in Single treatment process because it is not effective in organics removal compared with Color removal. The purpose of this research in order to evaluate the comparable removal efficiency of COD and color by the combination of advanced oxidation processes for the dyeing wastewater. The sequential treatment processes of Fenton process and ozonation was more effective to remove organics and color than ozonation and Fenton process. The result of Fenton process for the pretreatment presented as the 81% removal of organics whereas ozonation process for the pretreatent presented as the 22.1% removal of organics. The removal of colour was higher as 81.3% for the ozonation as the pretreatment than 77.7% for the Fenton process as the pretreatment.

PHOTO-FENTON 공정을 이용한 축산폐수처리시 운전인자의 최적조건 (Optimal Condition of Operation Parameter for Livestock Wastewater Treatment using Photo-Fenton Process)

  • 박재홍;장순웅;조일형
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.284-288
    • /
    • 2005
  • In this study, photochemical advanced oxidation processes (AOPs) utilizing the Photo Fenton reaction ($Fe^{2+}+H_2O_2+UV$) were investigated in lab-scale experiments for the treatment of livestock wastewater. For the experimets, the livestock wastewater was pretreated by coagulation with $3,000mg/L\;FeCl_3$. The optimal conditions for Photo-Fenton processes were determined: pH was 5, the concentration of ferrous ion (Fe II) was 0.01 M. The concentration of hydrogen peroxide was 0.1 M, and molar ratio ($Fe^{2+}/H_2O_2$) was 0.1. The optimal reaction time was 80 min. Under the optimal condition of Photo-Fenton process, chemical oxygen demand (COD), color and fecal coliform removal efficiencies were about 79, 70, and 99.4%, respectively and sludge production was 7.5 mL from 100 mL of solution.