• Title/Summary/Keyword: Femoral fixation

Search Result 82, Processing Time 0.03 seconds

Arthrodesis of the Knee Using a Retrograde Femoral Intramedullary Nail: Technical Report (역행성 대퇴부 골수강 내 금속정을 이용한 슬관절 고정술: 술기 보고)

  • Wang, Lih;Kim, Sun Hyo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.183-189
    • /
    • 2021
  • Arthrodesis is one of the last options available to obtain a stable, painless knee in patients who are unable to undergo reconstructive surgery due to a damaged knee joint. A variety of techniques have been used, including external fixation, internal fixation by compression plates, intramedullary fixation through the knee with a modular nail, and antegrade nailing through the piriformis fossa. Another option is the use of a short nail such as the Neff nail, the Wichita nail, or the Huckstep nail, but there are no commercial short nails available for use in Korea. This technical report describes a technique for knee arthrodesis using a retrograde femoral intramedullary nail.

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF

Correlation between anterior thigh pain and morphometric mismatch of femoral stem

  • Chung, Haksun;Chung, So Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.1
    • /
    • pp.40-46
    • /
    • 2020
  • Background: Postoperative pain occurring after hip arthroplasty has become common since the expanded use of cementless femoral stems. The characteristic pain develop in the anterolateral thigh area. This study aimed to predict anterior thigh pain based on the measurements of postoperative anteroposterior (AP) and lateral (Lat) radiographs of the hip joint. Methods: The present study included 26 patients (29 hips) who underwent total hip replacement or bipolar hemiarthroplasty between March 2010 and May 2016, whose complete clinical information was available. AP and Lat radiographs of the affected hip were taken on the day of surgery and 1 and 6 months postoperatively. Patients with improper radiographs were excluded. The distance from the femoral stem to the nearest cortical bone in the distal region of the stem was measured. The patient group with a visual analog scale (VAS) score of ≥6 points was designated as patients with anterior thigh pain. Results: Sex, age, weight, height, body mass index, and bone mineral density in the lumbar spine and femur did not have a significant effect on postoperative VAS scores (p>0.05). Presence of contact between the femoral stem and cortical bone was associated with postoperative anterior thigh pain. Conclusion: Hip AP and Lat radiographs are usually taken to confirm fixation and alignment of the femoral stem after hip arthroplasty. The measurement method introduced in this study can be utilized for predicting anterior thigh pain after hip arthroplasty.

Ultrasonographic Finding of Trochanteric Pain after Proximal Femoral Nailing in Patients with Intertrochanteric Fracture - 2 Cases Report - (대퇴 전자간 골절의 근위 대퇴 골수정 삽입술 후 발생한 전자부 통증의 초음파 소견 - 2예 보고 -)

  • Nam, Woo Dong;Han, Kye Young;Cha, Seong Moo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.38-41
    • /
    • 2011
  • After closed reduction and internal fixation with proximal femoral nail for intertrochanteric fracture, some patients complained lateral hip pain. We report two cases of lateral hip pain due to tendinopathy confirmed by ultrasonography.

  • PDF

Pseudoaneurysm Originating from the Lateral Femoral Circumflex Artery after Retrograde Intramedullary Nailing of a Distal Femur Shaft Fracture (원위 대퇴골 골절에서 역행성 골수 정 시행 후 발생한 외측 대퇴 회선 동맥 기원의 가성동맥류)

  • Yu, Jeongseok;Lee, Beom-Seok;Kim, Han-Bit
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.535-539
    • /
    • 2021
  • Vascular complications following a femoral fracture are rare but can result in serious issues. Several case studies have reported pseudoaneurysms occurring after direct trauma or the insertion of a proximal femoral nail in the case of a proximal femoral fracture. The authors encountered an 85-year-old patient treated with retrograde intramedullary nail fixation for a distal femur fracture and suffered a decrease in the hemoglobin level, swelling, and pain on the 9th day after surgery. The authors initially attributed the temporary hematoma and pain to ordinary postoperative processes. On the 16th day after surgery, a pseudoaneurysm originating from the descending branch of the lateral femoral convolutional artery was diagnosed and treated by percutaneous vascular embolization. After the procedure, the hemoglobin level increased, and the swelling and pain decreased.

An Atypical Subtrochanteric Femoral Fracture in a Patient with Multiple Myeloma Received Zoledronic Acid: A Case Report (졸레드론산을 투여한 다발성 골수종 환자에서 발생한 비전형적 대퇴골 전자하 골절: 증례 보고)

  • Jeong, Won-Ju;Na, Sang-Bong;Cho, Hwan-Seong;Kim, Joon-Woo;Park, Il-Hyung
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.18 no.2
    • /
    • pp.99-103
    • /
    • 2012
  • Little literature exists about the risk of atypical femoral fracture in patients received zoledronic acid for prevention of skeletal metastasis. We report an atypical subtrochanteric femoral fracture in a patient with multiple myeloma received zoledronic acid. The patient was treated by closed reduction and internal fixation with cephalomedullary nailing.

Biomechanical characteristics of the distal filling effects in cementless femoral stem (무시멘트형 대퇴스템에서 원위부 압박 정도에 따른 생체역학적 특성)

  • Park, Sang-eok;Park, Jae-Won;Chae, Soo-Won
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.387-392
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The initial stability has close relationship with the relative displacement of prosthesis and spongy bone at the proximal of femur. After implantation of the prosthesis. the surrounding bone is partially shielded from load carrying and starts to resort. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems, Three types of stems employed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

  • PDF

Arthroscopic Anterior Cruciate Ligament Reconstruction Using Autogenous Hamstring Tendon Graft Without Detachment of the Tibial Insertion (경골 종지부를 분리하지 않은 자가슬괵건을 이용한 관절경적 전방십자인대 재건술)

  • Kim Sung-Jae;Lee Yun-Tae;Kim Hyun-Kon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.81-85
    • /
    • 1997
  • This article describes a modified arthroscopic technique of anterior cruciate ligament (ACL) reconstruction using quadrupled hamstring tendon graft. The autogenous semitendinosus and gracilis grafts are harvested without detachment of the tibial insertion. To obtain longer graft, the accessory tibial insertions of the hamstring tendons are dissected. The EndoButton(Acupex Microsurgical, Andover, MA) is used for femoral fixation and two spiked staples are used for tibial fixation in a belt buckle fashion. Then the residual anterior laxity is restored by additional absorbable interference screw fixations. In this technique. more viable graft is obtained and firmer distal fixation is achieved by preservation of the tibial insertion of hamstring tendons.

  • PDF