• Title/Summary/Keyword: Feedwater heater

Search Result 31, Processing Time 0.032 seconds

A Study on the Fluid Mixing Analysis for the Shell Wall Thinning Mitigation by Design Modification of a Feedwater Heater Impingement Baffle (급수가열기 충격판 설계변경에 따른 동체감육 완화에 관한 유동해석 연구)

  • Kim K. H.;Hwang K. M.;Jin T. E.
    • Journal of the Korea Society for Simulation
    • /
    • v.14 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • Feedwater heaters of many nuclear power plants have recently experienced wall thinning damage, which will increase as operating time progresses. As it is judged that the wall thinning damages have generated due to local fluid behavior around the impingement baffle installed in downstream of the high pressure turbine extraction steam line to avoid colliding directly with the tubes, numerical analyses using PHOENICS code were performed for two models with original clogged impingement baffle and modified multi-hole impingement baffle. To identify the relation between wall thinning and fluid behavior, the local velocity components in x-, y-, and z-directions based on the numerical analysis for the model with the clogged impingement baffle were compared with the wall thickness data by ultrasonic test. From the comparison of the numerical analysis results and the wall thickness data, the local velocity component only in the y-direction, and not in the x- and z-direction, was analogous to the wall thinning configuration. From the result of the numerical analysis for the modified impingement baffle to mitigate the shell wall thinning, it was identified that the shell wall thinning may be controlled by the reduction of the local velocity in the y-direction.

  • PDF

Investigation on Transient Vibration of Piping System to Heater in a Power Plant (발전소 가열기 급수용 배관계 이상 진동 고찰)

  • 양경현;조철환;배춘희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.975-978
    • /
    • 2004
  • There was transient vibration on the piping system from #4 heater to the deaerator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and vibration induced by flow of feedwater. We verified it would reduce vibration by increasing stiffness of the piping system. Therefore we concluded that it would be generally better to increase stiffness of the piping system to reduce vibration amplitude of 10Hz low for big sized piping systems.

  • PDF

Performance analysis of an organic Rankine cycle for ocean thermal energy conversion system according to the working fluid and the cycle (작동유체 및 사이클에 따른 해양온도차발전용 유기랭킨사이클의 성능분석)

  • Kim, Jun-Seong;Kim, Do-Yeop;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.881-889
    • /
    • 2015
  • Ocean thermal energy conversion is an organic Rankine cycle that generates power using the temperature difference between surface water and deep water. This study analyzes the thermodynamic efficiency of the cycle, which strongly depends on the working fluid and the cycle configuration. Cycles studied included the classical simple Rankine cycle, Rankine cycles with an open feedwater heater and an integrated regenerator, as well as the Kalina cycle. Nine kinds of simple refrigerants and three kinds of mixed refrigerants were investigated as the working fluids in this study. Pinch-point analysis that set a constant pinch-point temperature difference was applied in the performance analysis of the cycle. Results showed that thermodynamic efficiency was best when RE245fa2 was used as the working fluid with the simple Rankine cycle, the Rankine cycles with an open feedwater heater and an integrated regenerator, and when the mixing ratio of $NH_3/H_2O$ was 0.9:0.1 in the Kalina cycle. If the Rankine cycles with an open feedwater heater, an integrated regenerator, and the Kalina cycle were used for ocean thermal energy conversion, efficiency increases could be expected to be approximately 2.0%, 1.0%, and 10.0%, respectively, compared to the simple Rankine cycle.

Thermal Stress Estimation due to Temperature Difference in the Wall Thickness for Thinned Feedwater Heater Tube (감육된 급수가열기 튜브의 두께 방향 온도차이에 의해 발생하는 열응력 평가)

  • Dinh, Hong Bo;Yu, Jong Min;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.1-9
    • /
    • 2019
  • A major stress determining the remaining life of the tube in feedwater heater of fossil fuel power plant is hoop stress by the internal pressure. However, thermal stress due to temperature difference across the wall thickness also contributed to reduce the remaining life of the tube. Therefore, thermal loading must be considered even though the contribution of internal pressure loading to the stresses of the tube was known to be much higher than that of the thermal loading. In this study, thermal stress of the tubes in the de-superheating zone was estimated, which was generated due to the temperature difference across the tube thickness. Analytic equations were shown for determining the hoop stress and the radial stress of the tube with uniform thinning and for the temperature across the tube thickness. Accuracy and effectiveness of the analytic equations for the stresses were verified by comparing the results obtained by the analytic equations with those obtained from finite element analysis. Using finite element analysis, the stresses for eccentric thinning were also determined. The effect of heat transfer coefficient on thermal stress was investigated using series of finite element analyses with various values of heat transfer coefficient for both inner and outer surface of the tube. It was shown that the effect of heat transfer coefficient at outer surface was larger than that of heat transfer coefficient at inner surface on the thermal stress of the tube. Also, the hoop stress was larger than the radial stress for both cases of uniformly and eccentrically thinned tubes when the thermal loading was only considered without internal pressure loading.

Visualization Experiment for Nucleate Boiling Bubble Motion on a Horizontal Tube Heater Fabricated with Flexible Circuit Board (연성회로기판 기반 수평전열관 표면의 비등기포거동 가시화 실험 연구)

  • Kim, Jae Soon;Kim, Yu-Na;Park, Goon-Cherl;Cho, Hyoung Kyu
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.52-60
    • /
    • 2016
  • The Passive Auxiliary Feedwater System(PAFS) is one of the advanced safety concepts adopted in the Advanced Power Reactor Plus(APR+). To validate the operational performance of the PAFS, detailed understanding of a boiling heat transfer on horizontal tube outside is of great importance. Especially, in the mechanistic boiling heat transfer model, it is important to visualize the phenomena but there are some limitations with conventional experimental approaches. In the present study, we devised a heater based on the Flexible Printed Circuit Board (FPCB) for a more comprehensive visualization and subsequently, a digital image processing technique for the bubble motion measurement was established. Using the measurement technique, important parameters of the nucleate boiling are analyzed.

Evaluation of Corrosion Product Behavior in NPP Secondary System with Complex Amine (복합아민 적용에 따른 원전 2차 계통 부식생성물 거동평가)

  • JUNG, Hyunjun;RHEE, In Hyoung;Kim, Young In
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.96-99
    • /
    • 2014
  • The aim of the study was to evaluate the water treatment of pressurized water reactor secondary side by the mixed amine of ammonia and ethanolamine, from the standpoint of corrosion control, as compared with all volatile treatment of ammonia. The pressurized water reactor systems have switched a secondary side pH control agent to minimize the corrosion in the moisture separator/reheater and feedwater heater systems and the transport of corrosion products into steam generator. As results of field test, pH was increased in the steam generator and the wet steam area of moisture separator/reheater and the concentration of Fe were decreased by more than 50% as compared with water treatment of ammonia.

Energy and Exergy Analysis of a Steam Turbine Cogeneration System (증기터빈 열병합 시스템에 대한 에너지 및 엑서지 해석)

  • Cho, Sung-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1397-1405
    • /
    • 2009
  • In recent decades, exergy analysis has been holding spotlight as a useful tool in the design, assessment, optimization, and improvement of energy system. This paper presents the results of the energy and exergy analysis of a steam turbine cogeneration system for industrial complex using two efficiency concepts of conventional one and exergetic one. In order to obtain the destroyed exergy of each component, mathematical analysis is conducted by using exergy balance and the second law of thermodynamics, according as the parameters are changed, such as the ratio of returned process steam, process steam supplied, temperature and pressure of boiler and power. The computer program developed in this study can determine the efficiencies and exergy destroyed at each component of cogeneration system. As a result of this study, a component having the largest destroyed exergy was boiler. And closed and opened feedwater heater had the lowest one. The affects to the cogeneration system due to the variation of process steam flow and return rate of condensed water is shown that the total electric power efficiency(${\eta}_E$) is decreased as increasing the return rate of condensed water under constant process steam flow. As the boiler pressure is increased for the more production of electricity, the efficiency of cogeneration system was decreased.

  • PDF

A Study on the Thermal Hydraulic Analysis and B-Scan Inspection for LDIE Degradation of Carbon Steel Piping in a Nuclear Plant (원전 탄소강 배관의 액적충돌침식 손상에 대한 B-Scan 검사 및 수치해석적 분석)

  • Hwang, Kyeong Mo;Lee, Dae Young
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.218-224
    • /
    • 2012
  • Liquid droplet impingement erosion (LDIE) known to be generated in aircraft and turbine blades is recently appeared in nuclear piping. UT thickness measurements with both A-scan and B-scan UT inspection equipments were performed for a component estimated as susceptible to LDIE in feedwater heater vent system. The thickness data measured with B-Scan equipment were compared with those of A-Scan. Thermal hydraulic analysis based on ANSYS FLUENT code was performed to analyze the behavior of liquid droplets inside piping. The wall thinning rate and residual lifetime based on both existing Sanchez-Caldera equation and measuring data were also calculated to identify the applicability of the existing equation to the LDIE management of nuclear piping. Because Sanchez-Caldera equation do not consider the feature of magnetite formed inside piping, droplet size, colliding frequency, the development of new evaluation method urgently needs to manage the pipe wall thinning caused by LDIE.