• Title/Summary/Keyword: Feeding Loop

Search Result 53, Processing Time 0.02 seconds

Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System (교류전기철도 급전시스템의 전차선 전압해석)

  • 이승혁;정현수;김진오
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.490-496
    • /
    • 2002
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode far locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Finally, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

  • PDF

Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System (단권변압기 교류전기철도 급전시스템의 전차선 전압해석)

  • 정현수;이승혁;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.9
    • /
    • pp.493-499
    • /
    • 2003
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode for locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Filially, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

Pattern-Switchable Microstrip Patch Antenna with Loop Structure (패턴 변환 루프 구조를 가지는 마이크로스트립 패치 안테나)

  • Kim, Yongjin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5447-5451
    • /
    • 2012
  • This paper presents a pattern-switchable microstrip patch antenna with loop structure. The loop structure for switchable radiation beam pattern is connected with feeding line of the microstrip patch antenna. As changing switch on/off state, the radiation beam pattern can be changed. The target frequency is 2.4 GHz and maximum radiation gain is 3.2dBi. The proposed antenna is useful for diversity antenna and smart antenna in modern wireless communication including MIMO (Multi-Input Multi-Output) and WLAN system. The sizes of the rectangular patch and the ground plane are $28mm{\times}28mm$ and $40mm{\times}50mm$, respectively. The simulation and experimental results show that the antenna radiation pattern can be changed with switch on/off configuration.

Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop (Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구)

  • Lee, K.O.;Choi, J.Y.;Choy, I.;Jung, Y.S.;Yu, G.Y.;Song, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

Active Frequency Drift Positive Feedback Method for Anti-islanding using Digital Phase-Locked-Loop (디지털 위상검출기법을 적용한 능동적 주파수 변화 정궤환기법)

  • Lee, Ki-Ok;Young, Young-Seok;Choi, Ju-Yeop;Choy, Ick;Song, Seung-Ho;Ko, Moon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.37-44
    • /
    • 2007
  • As photovoltaic(PV) power generation system becomes more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of the load and PV system are closely matched, islanding detection by Passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

Design of a Modified Alford Loop Antenna for On-Body Devices (인체 부착형 기기를 고려한 변형된 Alford 루프 안테나 설계)

  • Park, Joongki;Lee, Juneseok;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.25-31
    • /
    • 2014
  • In this paper, a modified Alford loop antenna for on-body communication system is proposed. The proposed antenna operating in the ISM band is designed with consideration of human body effect. One of advantages of the Alford loop antenna structure is low-profile, however the Alford loop antenna is not suitable for on-body devices since it does not have a ground plane for other electronic part of on-body system and requires balanced feeding structure. To be embedded on on-body devices, the proposed antenna is design with the unbalanced feed structure and ground. The performance of the proposed antenna is simulated and measured when it is placed on the human body phantom to consider the effect of the human body. The proposed antenna a 10 dB return loss bandwidth over the ISM band and monopole-like radiation pattern with low-profile. The antenna has the surface of appropriate for on-body communication environment.

Congenital Esophageal Atresia and Tracheoesophageal Fistula: Report of Two Cases (선천성 식도폐쇄 및 기관식도루: 2례 보고)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.6 no.1
    • /
    • pp.89-94
    • /
    • 1973
  • Esophagel atresia and tracheoesophageal fistula may occur as separate entities but usually occur in combination. First described by Durston in 1670, esophageal atresia was not successfully treated until 1939 when Ladd in Boston and Leven in St. Paul obtained the first survivors utilizing the methods of gastrostomy, esophagostomy and extrapleural ligation of the tracheoesophageal fistula as multiple operations which required months of hospitalization. Two years later Cameron Haight performed the first successful primary repair and afterward about 2000 cases of esophageal atresia with distal tracheoesophageal fistula reported in the world. In Korea, there appeared about 27 cases in the literature and 8 successful repaired cases noted in these year. Anther report two cases of esophageal atresia, of which one case was successfully treated with Haight`s method. Case 1.: Normal full term delivered boy with chief complaints of respiratory difficulty and persistent drooling with chocking, 3. lkg, was admitted with emergency 5 hours after delivery. Physical findings revealed no specific abnormal signs except distended abdomen and grunting respiration. Esophagograrn and bronchogram revealed proximal esophageal atresia and distal tracheoesophageal fistula proximal to the carina. Parent refused operative therapy and patient died 24 hours after discharge. Case 2. :3. lkg. normal full term delivered girl was admitted 4 days after delivery with chief complaints of regurgitation after feeding, chocking, cyanotic spell and fever since the day after delivery. Physical examination revealed persistent drooling, grunting respiration, and fever with moderate dehydration. Tracheoesophageal suction and fluid therapy with antibiotics improved her condition and subsided ]pneumonic condition. Esophagogram revealed markedly dilated proximal esophagus as blind loop and stomach distended with gas, and repairing operation as Haight`s method was performed on the 7th day after delivery. Patient tolerated all the operative procedure well and recovered uneventfully. Esophagogram on the 7th postoperative day showed passage of the lipiodol through the anastomotic side with moderate stricture,and feeding permitted. Patient tolerated all the feeding amount well and discharged on the 11th postoperative day. Followup revealed intermittent regurgitation after feeding and corrected with bougination.

  • PDF

Folded Loop Antennas for RFID Appilication (RFID 응용을 위한 폴디드-루프 안테나)

  • Choi, Tea-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.4
    • /
    • pp.199-202
    • /
    • 2007
  • In this paper, we examined the operating principle of a passive tag antenna for RFID system in UHF band. Based on the study, we proposed a novel RFID tag antenna which adopts the inductively coupled feeding structure to match antenna impedance to a capacitively loaded commercial tag chip. The proposed tag antenna consists of microstrip lines on a thin PET substrate for low-cost fabrication. The detail structure of the tag antenna were optimized using a full electromagnetic wave simulator of IE3D in conjunction with a Pareto genetic algorithm, and the size of the tag antenna can be reduced up to kr=0.27(2 cm2). We built some sample antennas and measured the antenna characteristics such as a return loss, an efficiency, and radiation patterns. The readable range of the tag antenna with a commercial RFID system showed about 1 to 3 m.

  • PDF

Dualband Shared-Aperture Microstrip Antenna for Reflectarray Feeding Structure of LEO Satellite System

  • Bagas Satriyotomo;Ji-Woong Hyun;Seongmin Pyo
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.20-25
    • /
    • 2024
  • This paper presents a new dualband shared-aperture microstrip antenna to operate in the S-Band of 2 GHz and X-Band of 8 GHz, for a Low Earth Orbit satellite antenna system. The proposed antenna incorporates two types of patches those are a rectangular loop-shaped for the S-Band and a square patch for the X-Band. Each patch are optimized for its respective operating band with minimal interference. The proposed antenna achieves a bandwidth of 16 MHz in the S-Band and 572 MHz in the X-Band. The highest gain is measured 7.14 dBi at 1.99 GHz and 7.95 dBi at 7.88 GHz. The proposed antenna exhibits half power beamwidths of 85 degree and 80 degree at 1.99 GHz and 7.88 GHz, respectively. The proposed dualband shared-aperture microstrip antenna may be a good candidate for as a feeding system of a dualband reflectarray antenna With its unidirectional radiation pattern from excellent agreement between simulation and measurement results.

Hybrid Planar Inverted-F Antenna with a T-Shaped Slot on the Ground Plane

  • Jeon, Sin-Hyung;Choi, Hyeng-Cheul;Kim, Hyeong-Dong
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.616-618
    • /
    • 2009
  • In this letter, a novel hybrid planar inverted-F antenna (PIFA) with a T-shaped slot on the ground plane is proposed. The loop structure formed by the feed line and shorting pin can be operated as a series and shunt inductance for the PIFA and the T-shaped slot antenna, respectively. The PIFA operates at a frequency of 1.75 GHz, while the T-shaped slot on the ground plane operates at 2.4 GHz by the same voltage feeding source. The height of the PIFA is 6.5 mm, and the size of an upper patch is designed to be 30 mm${\times}$16 mm. The measured relative impedance bandwidth of the PIFA and the T-shaped slot are about 12% and 21%, respectively. In addition, good antenna performance was achieved.