• 제목/요약/키워드: Feeder Network

검색결과 109건 처리시간 0.023초

신경회로망과 DWT를 이용한 고장표시기의 고장검출 개선에 관한 연구 (A Study for the Improvement of Fault Detection on Fault Indicator using DWT and Neural Network)

  • 홍대승;임화영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.46-48
    • /
    • 2007
  • This paper presents research about improvement of fault detection algorithm in FRTU on the feeder of distribution system. FRTU(Feeder Remote Terminal Unit) is applied to fault detection schemes for phase fault, ground fault, and cold load pickup and Inrush restraint functions distinguish the fault current and the normal load current. FRTU is occurred FI(Fault Indicator) when current is over pick-up value also inrush current is occurred FRTU indicate FI. Discrete wavelet transform(DWT) analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate inrush current from the fault status by a gradient descent method. In this paper, fault detection is improved using voltage monitoring system with DWT and neural network. These data were measured in actual 22.9kV distribution system.

  • PDF

지능형 응집제 투입 시스템의 개발 (Development of intelligent coagulant feeding system)

  • 정우섭;오석영
    • 제어로봇시스템학회논문지
    • /
    • 제3권6호
    • /
    • pp.652-658
    • /
    • 1997
  • Coagulant feeding control is very important in the water treatment process. Coagulant feeding is related to the raw water quality such as turbidity, alkalinity, water temperature, pH and so on. However, since the process of chemical reaction has not been clarified so far, coagulant dosing rate has been decided by jar-test. In order to overcome the difficulty mentioned above, Fuzzy Neural Network to fuse fuzzy logic and neural network was proposed, and the scheme was applied to the automatic determination of coagulant dosing rate. This algorithm can automatically identify the if-then rules, tune the membership functions by utilizing expert's experimental data. The proposed scheme is evaluated by computer simulation and interfaced with coagulant feeder operated by magnetic flowmeter, control valve and PLC. It is shown that coagulant feeding according to real time sensing of water quality is very effective.

  • PDF

A FEEDER CONTROL FOR THE SMT MOUNTER USING LON CHIP

  • Lim Eung-Kyu;Rho Sung-Chan;Kim Yoon-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.121-125
    • /
    • 2001
  • SMD mounter is necessary in PCB assembling line. To feed SMD components to the mounter, high performance feeders are needed. Until now, mechanical air feeders have been mainly used. However, in these days, electrical feeders with network are developed. There are many kinds of feeders with various control techniques. In this paper, a feeder with BLDC motor and LON chip is designed and implemented. And, the experimental results are presented.

  • PDF

GTEM 셀 설계를 위한 전자파 모델링 및 회로망 해석 기법 연구 (A Study on the Electromagnetic Modeling and Network Analysis for GTEM Cell Design)

  • 이우상
    • 한국전자파학회논문지
    • /
    • 제19권7호
    • /
    • pp.791-799
    • /
    • 2008
  • 본 논문에서는 $DC{\sim}18\;GHz$에서 동작하는 GTEM 셀 설계를 위한 전자파 모델링과 회로망 해석 기법을 제시하였다. GTEM 셀의 동축선 입력 급전부의 모드 변환기, 전송선 길이가 5미터인 확장형 사각 동축선 그리고 전송부 동축선의 전류와 입력단으로부터 입사되는 전자파를 정합시킬 수 있는 종단 부하로 구성되는 3차인 전자파 수치 해석 모델을 제시하였다. GTEM cell의 급전부, 전송선부, 종단 부하부에 대한 등가 회로망 모델을 제시하였으며, 이를 이용하여 전자파 수치 해석 모델에서 구해진 산란 계수로부터 GTEM cell의 성능 평가 지수인 입력 반사 계수를 계산할 수 있도록 하였다. $DC{\sim}18\;GHz$에서 동작하는 $5.0{\times}2.5{\times}1.7\;m$ 크기의 GTEM cell을 설계, 제작, 성능 평가하여 제안한 기법의 효용성을 입증하였다.

퍼지클러스터링 기법과 신경회로망을 이용한 고장표시기의 고장검출 능력 개선에 관한 연구 (A Study on the Improvement of Fault Detection Capability for Fault Indicator using Fuzzy Clustering and Neural Network)

  • 홍대승;임화영
    • 한국지능시스템학회논문지
    • /
    • 제17권3호
    • /
    • pp.374-379
    • /
    • 2007
  • 본 논문은 전력계통의 배전계통시스템에서 FRTU(Feeder remote terminal unit)의 고장검출 알고리즘의 개선에 관한 연구이다. FRTU는 상과 지락에 관한 고장검출을 할 수 있다. 특히 고장픽업 기능과 돌입억제기능은 일반적인 부하전류로부터 고장전류를 구별할 수 있다. FRTU는 돌입전류 또는 설정값을 초과한 고장전류가 발생하면 고장표시기(FI)로 고장을 발생한다. 짧은 시간 푸리에 변환(STFT) 분석은 주파수와 시간에 관한 정보론 제공하고, 퍼지 중심 평균 클러스터링(FCM) 알고리즘은 고조파의 특성을 추출한다. 고장 검출기의 신경회로망 시스템은 최급강하법을 이용하여 고장상태로부터 돌입전류를 구별하도록 학습된다. 본 논문에서는 FCM과 신경회로망을 이용하여 고장검출기법을 개선하였다. 검증에 사용된 데이터는 22.9KV 배전계통 시스템에서 실제 측정된 데이터이다.

LAN을 이용한 분산전원 연계 계통의 보호 (LAN-Based Protective Relaying for Interconnect Protection of Dispersed Generators)

  • 정태영;백영식
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.491-497
    • /
    • 2007
  • As dispersed generators was driven in condition interconnecting with utility, it could cause a variety of new effects to the original distribution system that was running as considered only the one-way power flow. Therefore, the protection devices that is builted in distribution system should be designed to be able to operate with disposing of not only a fault of the generator, but also utility condition. Especially, the fault of the feeder interconnected with Dispersed Generator can cause the islanding phenomenon of open DG(Dispersed Generators). This phenomenon has many problems such as a machinery damage, electricity qualify degradation and a difficulty of the system recovery. In the fault therefore, we must separate Dispersed Generator from the system quickly. In this paper, for the fault classification of the interconnected DG and the outside feeder we judge the fault of the interconnected DG and the outside feeder in HMI through data provided by IED(Intelligent Electronic Device) on the network and decide whether it operates or not by sending the result to each relay.

Distribution Network Switching Automation Using Active Web Based Management

  • Choi, Sang-Yule
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.81-86
    • /
    • 2007
  • Electric utility companies have the responsibility of providing good electricity for their customers. They have introduced the DAS(Distribution Automation System) to automate the power distribution networks. DAS engineers require state-of-the-art applications, such as a way to actively manage the distribution system and gain economic benefits from a flexible DAS architectural design. The existing DAS is not capable of handling these needs. It requires operator intervention whenever feeder overloading is detected while operator error could cause the feeder overload area to be extended. It also utilizes a closed architecture and it is therefore difficult to meet the system migration and future enhancement requirements. This paper represents a web based, platform-independent, flexible DAS architectural design and active database application. Recent advanced Internet technologies are fully utilized in this new DAS architecture allowing it to meet the system migration and future enhancement requirements. By using an active database, the DAS can minimize the feeder overloading area in the distribution system without operator intervention, thereby minimizing mistakes due to operator error.

경험적 탐색기법에 근거한 배전계통의 선로 재구성 앨고리즘 (NETWORK RECONFIGURATION ALGORITHM FOR AUTOMATED DISTRIBUTION SYSTEM BASED ON THE BEST-FIRST TREE SEARCH)

  • 정경희;김호용;고윤석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.350-353
    • /
    • 1991
  • This study develops an expert system which solves the problems of the MTr/feeder overloads and the feeder constraints in automated radial distribution systems. Then, the objective is to perform the network reconfiguration by switching the tie and sectionalizing switches which eliminates the system violation, while achieving the load balance of the MTrs/feeders. To reduce the search space, an expert system based on heuristic rules is presented, and implemented in AI language Prolog. This system adopts the best-first tree search technique. The computational results are also prepared to show the performance of the heuristic algorithm developed.

  • PDF

버스운행관리 및 수송전략에 관한 연구 (A Study on the Bus Operation Management and Transport Strategy)

    • 한국항만학회지
    • /
    • 제13권2호
    • /
    • pp.323-332
    • /
    • 1999
  • The bus should supply an equal service to the whole community as feeder trip. However the existing bus route can not supply an effective feeder service in spite of the changes in the latent demand by the variety of regional structural change. This study aimed to establish the concept which frames the bus operation and management to cope with the latent demand to the bus. This study tackled this evidence by analyzing the transportation problems in terms of the urban growth emphasizing the following issues ; First, the strategy to improve the bus operation Second the land use control appropriate for the public transportation network Third economical range to justify the bus operation Second, the land use control appropriate for the public transportation network Third, economical range to justify the bus operation Fourth, the allowance for the private transportation mode On the latter part, the difference on the bus operation was compared to determine the range within which the bus operation could be justified. This study would provide some implications to improve the management for bus operation and fundamental information to develop the bus operation system.

  • PDF

코호넬 신경회로망을 이용한 배전시스템의 전압/무효전력 제어게 관한 연구 (A Study on the Voltage/Var Control of Distribution System Using Kohonen Neural Network)

  • 김광원;김종일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.329-331
    • /
    • 1998
  • This paper presents a modified Learning Vector Quantization rule to control shunt capacitor banks and feeder voltage regulators in electric distribution systems with Kohonen Neural Network(KNN). The objective of the KNN is on-line decision of the optimal state of shunt capacitor banks and feeder voltage regulators which minimize $I^{2}R$ losses of the distribution system while maintaining all the bus voltages within the limits. The KNN is tested on a distribution system with 30 buses, 5 on-off switchable capacitor banks and a nine tap line voltage regulator.

  • PDF