• Title/Summary/Keyword: Feeder Automation

Search Result 70, Processing Time 0.029 seconds

Development of Protection Coordination Algorithm for Smart Distribution Management System using Communication Method based on IEC61850 (IEC61850 기반의 통신방식을 이용한 스마트 배전운영시스템용 보호협조 알고리즘 개발)

  • Chu, Cheol-Min;Yun, Sang-Yun;Kwan, Seung-Chul;Chu, Kyung-Yong;Jin, Young-Kyu;Choi, Myeon-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1412-1419
    • /
    • 2012
  • In this paper, we propose the protection coordination algorithm using communication methode based on IEC 61850. The communication protocol in power distribution management system has been issued by IEC standard, IEC61850 of them, which was made for substation automation system, has researched to apply into power distribution system, even though the standard is not a suitable for the system. In smart distribution management system' launched in 2009, the communication network based on the ethernet network for IEC 61850 has been designed to apply the self-healing concept, which is to perform the system protection through the communication between remote terminal units(RTU) according to the standard. However, it is first time to apply the scheme in the real. Thus, this paper proposed the protection algorithm and consideration for applying communication method and introduced the result of demonstration.

A Study on Outage Restoration Guide Including Load Cutoff in Distribution System (부하차단을 포함한 배전계통 정전복구방안에 관한 연구)

  • 김세호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.98-104
    • /
    • 2004
  • This paper represents the fast and efficient load transfer guide for fault or outage restoration in distribution system. For restoration guide, system trace is performed to reverse direction(source side) from tie breaker in tree-structured distribution network. Search space and breaker's combinational number for restoration guide are greatly reduced. It is proposed the load transfer method including first stage restoration(single load transfer, double load transfer, triple load transfer), second stage restoration(transferring load to neighboring feeder in order to expand the capacity margin) and load cutoff guide. The proposed method can be easily applied to primary customer restoration, multi-fault recovery and distribution automation system.

Integrated Voltage/Var control based on Distributed Load Modeling with Distributed Generation in Distribution System (분산전원이 설치 된 배전 계통의 분포부하를 이용한 IVVC알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choe, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.95_96
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load with Distributed Generation and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

  • PDF

Integrated Volt/Var Control Algorithm based on the Distributed Load Modeling of Distribution Network (배전계통의 분포 부하 모델링을 통한 최적화 IVVC 알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Kwon, Sung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1463-1471
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

A Voltage Control Method based on Constants of Four Terminals Network Modeling of Distribution Networks

  • Yang, Xia;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Kim, Tae-Wan
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.354-362
    • /
    • 2008
  • In this paper, a new algorithm of optimal voltage control is proposed for the Distribution Automation System (DAS) based on constants of four terminal network modeling. In the proposed method, the voltage profiles along feeders are estimated from the measurement of the current and power factor by a Feeder Remote Terminal Unit (FRTU) installed at each node. Whenever the voltage profile violates the restriction, the voltage control strategy is applied to keep the voltage levels along the feeders within the pre-specified range through the modification and coordination of the transformer under-load tap changers (ULTC), step voltage regulator (SVR), as well as shunt condenser. In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with 11 nodes.

The Fault Distance Computation Method for Fault Location Identification of Distribution System (배전계통 고장위치 확인을 위한 고장점 표정기법)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.276-281
    • /
    • 2008
  • Because the distribution systems experience frequently the fault by several causes, the identification task of fault location plays very important role in the view point of power supply reliability. The distribution systems are designed as radial structure with three-phase and single-phase branch line to supply the electric power to the widely dispersed loads, and it have a several load taps within each line segment. it makes the accurate fault distance determination difficult. Accordingly in this papers, the existing fault point determination methods are surveyed and analyzed, and then a fault distance determination method for distribution feeder is adopted which can be executed effectively in DAS center. Finally, the adopted method is verified using EMTP simulation.

  • PDF

Ungrounded System Fault Section Detection Method by Comparison of Phase Angle of Zero-Sequence Current

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung;Lim, Seong-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.484-490
    • /
    • 2008
  • In this paper, an integrated fault section detection and isolation strategy is proposed based on the application of the Distribution Automation System(DAS) utilizing advanced IT and communication technologies. The Feeder Remote Terminal Unit(FRTU) has been widely used to collect data in the Korean distribution system. The achieved data is adopted in this method for detecting multiple fault types. Especially in the case of single phase-to-ground fault, the fault section is detected by comparison of the zero-sequence current phase angle. The test results have verified the effectiveness of the proposed method in a radial distribution system through extensive simulations in Matlab/Simulink. Furthermore, a communication-based demo system identical to the simulation model has been developed, and it can be applied as an online monitoring and control program for fault section detection and isolation.

Development of Individual Electronic Identification System Using the Inductive Transmission Method for Stockbreeding Management (개체관리를 위한 인덕터 전송방식의 개체인식 시스템 개발)

  • Ko, S.C.;Han, B.S.;Lee, J.;Kim, Y.J.;Lee, S.Y.
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.451-458
    • /
    • 2002
  • This paper introduces that livestock can be effectively managed by an individual electronic identification system. The proposed system was composed of the original code transmitter, receiver, personal computer, micro-processor, and RS485 telecommunications module. In the individual electronic identification system, the signal including encoded information of a milk-cow was transmitted from an original code transmitter to a micro-processor through RS485 telecommunications module. The transmitted signal can be successfully displayed in a personal computer. This system can be managed by 9999 individuals with a original code transmitter. The recognition rate of an individual electronic identification system was 98.5% and also auto-feeder operates very well. an individual electronic identification system was developed for automation of stockbreeding management. To automate the breeding management, it is necessary to obtain and analyze the individual information distinguished from others preferentially.

The Optimal Volt/Var Control Algorithm with Distributed Generation of Distribution System (분산전원이 연계된 배전계통의 최적 전압/무효전력 제어 알고리즘)

  • Kim, Young-In;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lee, Sung-Woo;Ha, Bok-Nam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.298-305
    • /
    • 2010
  • In this paper, a new algorithm of optimal Volt/Var Control is proposed using Volt/Var control for the Distribution Automation System (DAS) with Distributed Generation (DG) based on the modeling of the distributed load and the distributed current. In the proposed, algorithm based on the modeling of the distributed load and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU) and DG data from RTU for DG. For the optimal Volt/Var Control, the gradient method is applied to find optimal solution for tap, capacity and power control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), PC (Power Condenser) and DG (Distributed Generation). In the case studies, the estimation and control of the voltages have been testified in a radial distribution system with DG using matlab program.

Contingency Analysis about Restoration of outage in Distribution System (정전복구에 대한 배전계통 상정사고 해석법)

  • Park, Jeong-Eun;Kim, Hyung-Seung;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Seong-Il;Hyun, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1317-1325
    • /
    • 2016
  • This paper identifies the issues of contingency analysis for restoration in distribution systems. Contingency analysis has been applied to transmission systems but not to distribution systems. The distribution system is different from transmission system. So it is hard to apply for existing contingency analysis to distribution system. In this paper, a new contingency analysis method for distribution systems is proposed. The proposed method is based on service restoration capability. It aims to minimize outage left after service restoration in case of a fault in advance. The method estimates the vulnerability which is represented by zone restoration index proposed in [1]. Applying the proposed method, operators could change the system so that it does not leave any outage left after restoration. Case study has been carried out on a five feeder system and its results show effectiveness of the method.