• 제목/요약/키워드: Feeder Automation

검색결과 70건 처리시간 0.031초

SCADA 기능과 전기품질 온라인 감시 및 배전설비 열화감시 기능을 갖는 배전지능화 시스템 개발 (Development of intelligent distribution automation system with the function of substation SCADA, power quality monitoring and diagnosis condition monitoring)

  • 하복남;이성우;신창훈;서인용;장문종;박민호;윤기갑;송일근;이병성;이정철;남궁원
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1776-1786
    • /
    • 2010
  • Intelligent distribution automation system have total monitoring and control capability. The system covers substation, distribution network, distributed generations and customers at HV system. Various intelligent distribution facilities installed at distribution systems have voltage sensor, current sensor, aging monitoring sensor. Intelligent Feeder Remote Terminal Unit (IFRTU) tied to intelligent distribution facilities process information from facilities and it checks information of fault, power quality and aging of distribution facilities. The information is transmitted to master station through communication line. The master station have remote monitoring system covers substation, distribution network, distributed generations and customers. It also have various application programs that maintain optimal network operation by using information from on-site devices.

산란계농가의 자동화계사 시설실태 및 의식조사 연구 (Survey on the Automation of Laying Hen Houses and Farmers' Awareness of its Significance)

  • 최희철;서옥석;이덕수;한정대
    • 한국축산시설환경학회지
    • /
    • 제2권2호
    • /
    • pp.103-110
    • /
    • 1996
  • This survey was conducted to investigate the situation of three types of laying hen houses and farmers' awareness of farm automation. Six windowless, three high-rising windowless and four open-sided laying hen houses were surveyed to compare their characteristics, and sixty farmers answered questionnaires. 1. Population density of laying hen was 13.9 birds/m^2$ in open-sided, 28.9 birds/m^2$ in high-rising windowless, and 44.9 birds/m^2$ in windowless laying hen houses. 2. Feeder space was $12{\sim}13.5cm$ in open-sided laying hen houses, but feeder space of windowless and high-rising hen houses was narrower than that of open-sided laying hen houses. 3. Thermal resistance values were $14.6{\sim}18.7\;m^2\;{\circ}C/W$ in wall, #22.0{\sim}23.7\;m^2\;{\circ}C/W$ in roof of windowless and high-rising windowless laying hen houses but the wall of open-sided laying hen houses was only $1.9\;m^2\;{\circ}C/W$. 4. Maximum ventilation capacity was 0.161{\sim}0.326$ cmm/bird in summer. Minimum rate of tunnel Ventilation laying hen houses in winter was $0.013{\sim}0.040$ cmm/bird, but minimum rate of crossflow and high-rising windowless laying hen houses was larger than that of tunnel ventilation houses. 5. One person managed about 8,100 birds in open-sided, and about 23,500 birds in windowless and high-rising windowless laying hen houses. 7. 90.7% of farmers responsed that they want to construct automatized laying hen houses in the future.

  • PDF

LabVIEW를 이용한 가상 배전계통의 HILS 시스템 구축에 관한 연구 (A Study on HILS System for Virtual Distribution System Using LabVIEW)

  • 이원석;황선환;김태성
    • 전기전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.385-391
    • /
    • 2020
  • 배전계통에서의 과전류 및 이상 전압 현상은 전력설비에 부담을 줄 뿐만 아니라 수용가에 치명적인 피해를 입힐 수 있다. 그로 인해 실시간 배전계통 시뮬레이터를 활용하여 신속한 고장처리와 정전구간 축소 및 고장복구를 통한 전력공급의 신뢰도를 높이는 배전자동화 관련 연구가 활발히 진행되고 있다. 기존의 디지털 시뮬레이터를 이용한 배전계통 모의시스템은 고가의 설비로 시스템 구축에 제약이 있고 실 배전계통을 통한 검증 또한 불가능하다. 본 논문에서는 배전계통 디지털 시뮬레이터의 계통해석결과를 기반으로 배전자동화용 단말장치와의 연동을 통해 실시간 시뮬레이션 및 기능검증이 가능한 시스템을 개발하였다. 제안한 시스템의 효용성은 실험을 통해 검증하였다.

배전자동화 중앙장치에서 필터링 알고리즘을 통한 고장표시 오류 개선방법 (An Improved Method of Fault Indication Information Using Filtering Algorithm)

  • 서정수;김형승;임성일;최면송;이승재
    • 전기학회논문지
    • /
    • 제64권10호
    • /
    • pp.1418-1425
    • /
    • 2015
  • In this paper, an filtering method of FI(Fault Indication) information generated by FRTU(Feeder Remote Terminal Unit)s is proposed for the present DAS(Distribution Automation System). In order to find fault area, correct FI information should be generated. But when a single line-to-ground fault occurs, FI information is generated in downside of the fault in some circumstance because existing FI algorithm considers only magnitude. These wrong FI information can be removed by changing existing algorithm. An improved algorithm considers both the direction of zero-sequence current and the phase of three-phase current&voltage. But many FRTUs are distributed in DAS and Changing the algorithm all of FRTU will spend a lot of time and cost. On the other hand, an filtering algorithm proposed in this paper can substitute for it. The filtering algorithm also considers both the direction of zero-sequence current and the phase of three-phase current&voltage. In case study, the proposed method has been shown the reasonability in filtering the fault indication information.

배전선로 고장인지 방식에 관한 연구 (A Study on Improving of Fault Recognition Method in Distribution Line)

  • 이진;박찬
    • 한국전기전자재료학회논문지
    • /
    • 제33권1호
    • /
    • pp.65-69
    • /
    • 2020
  • The aim of this study is to improve the fault decision ability of FRTU (Feeder remote terminal unit) in DAS (Distribution automation system). FRTU uses the FI (Fault indicator) algorithm based on fault current pickup and operation of the protection device. Even if the inrush current flows or the protection device is sensitive to the transient current, FRTU may indicate incorrect fault information. To address these problems, we propose an improved fault recognition algorithm that can be applied to FRTU. We will detect a specific wave that is indicative of a fault, and use this information to identify a fault wave. The specific wave-detection algorithm is based on the duration and periodicity of the voltage, current, and harmonic variations. In addition, we propose fault recognition algorithms using voltage factor variation analysis and DWT (Discrete wavelet transform). All the wave data used in this study were actual data stored in FRTU.

머신비전을 이용한 PWM Shaft의 자동검사 시스템 개발 (Development of an Automatic Inspection System for PWM Shaft Using Machine Vision)

  • 배진호;김성관
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.125-130
    • /
    • 2013
  • In this paper, in order to overcome shortcomings of manual inspection for the automotive PWM Shaft, we developed an automated inline inspection system. The automated inline inspection system consists of the work feeder unit, conveying unit, outer diameter check unit, run-out and roundness check unit, machine vision, defective separation unit and status alarm unit. We used the machine vision system for automatic inspection process and designed the inline systems for automatic feeding and selecting process. Also the repeated operation test was performed in order to verify the precision and reliability of the proposed automated inline inspection system.

배전자동화용 스위치 제어장치의 전자기적합성(EMC) 고찰 (Electromagnetic Compatability of Feeder Terminal Unit and Control Cubicle for Distribution Automation Switch)

  • 김언석;손화영;김재철;김태수;임태현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.340-342
    • /
    • 2002
  • 본 논문에서는 배전자동화용 스위치 제어장치의 전자기적합(EMC)에 대하여 고찰하였다. 먼저, 자동화용 제어장치의 EMC 성능에 영향을 주는 요인들을 분석하였다. 또한 제어장치 관련 국내외 규격들의 EMC 평가항목 및 기준을 검토하였다. 검토결과 국제규격보다 미흡함을 발견하였다. 검토결과를 바탕으로 국내 규격의 EMC 추가 항목 및 개선방안을 제안하였다.

  • PDF

배전자동화 기반의 배전계통 최적운전 기법 개발 (The development of optimal operating system in distribution networks based on distribution automation)

  • 하복남;설일호;정미애;신익수;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.427-429
    • /
    • 2003
  • The reliability performance of distribution networks will be enhanced with the installation of application programs including feeder reconfiguration program for loss minimization and optimization of system capacity. Although the basic functions of remote monitoring and remote control provide no measurable cost benefit the suite of application programs developed and now being commissioned by KEPCO, the future will continue to offer this utility with substantial savings in system operational costs, improve system reliability and customer service.

  • PDF

IEC 61850 기반 FRTU 개발에 관한 연구 (IEC61850 Based FRTU Development Scheme)

  • 관창;최면송;한승수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.497-498
    • /
    • 2007
  • When we implement the substation automation, the largest problem is that IEDs may come from different vendors, which will result in the reduction of the reliability of communication between IEDs. To solve the problem IEC61850 is investigated, which uniforms the communication interface. However, in order to communicate with an IEC61850 implanted IED, FRTU (Feeder Remote Terminal Unit) need to be compatible with IEC6185 consequentially. A new IEC61850 based FRTU development scheme is proposed. The performance shows his compatibility with other IEC61850 IED, which has already been tested in ARET (Agent-based Reliability Enhancement Technology) system.

  • PDF

배전선로의 특이파형 검출 방법에 관한 연구 (A Study on Detection Method of Specific Waveform in Distribution Line)

  • 이진;박찬
    • 한국전기전자재료학회논문지
    • /
    • 제32권2호
    • /
    • pp.151-156
    • /
    • 2019
  • The aim of this investigation is to detect specific waveforms in a distribution line prior to the occurrence of a fault. Conditions were introduced such that a feeder remote terminal unit (FRTU) of the distribution automation system selects and stores fault waveforms from the different waveforms detected in the distribution line. In addition, an algorithm was developed to detect specific waveforms from the fault waveforms stored using the FRTU. This algorithm exploits the duration and periodicity of harmonic changes in voltage and current. The efficacy of the algorithm was confirmed based on the measurements of fault waveforms in an actual distribution line. The results indicated that faults in a distribution line can be predicted via experimental measurements.