• Title/Summary/Keyword: Fe-Pc

Search Result 107, Processing Time 0.022 seconds

Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio (중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동)

  • Lee, Seung-Jun;Seo, Soo-Yeon;Pei, Wenlong;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.441-448
    • /
    • 2014
  • From several researches, recently, it was found that using hollowed precast concrete (HPC) column made more compact concrete casting in joint region possible than using normal solid PC (Precast concrete) column. Therefore, the rigidity of joints can be improved like those of monolithic reinforced concrete (RC). After filling the hollow with grout concrete, however, it is expected that the HPC column behaviors like composite structure since PC element and grout concrete have different materials as well as there is a contact surface between two elements. These may affect the structural behavior and strength of the composite column. A compressive strength test was performed for the HPC column with parameter of hollow ratio for the case with and without grout in the hollow and the result is presented in this paper. The hollow ratios in the test are 35, 50 and 59% of whole section of column. Concentrated axial force was applied to top of the specimens supported as pin connection for both ends. In addition, finite element (FE) analysis was performed to simulate the failure behavior of HPC column for axial compression. As a result, it was found that the hollow ratio did not affect the initial stiffness of HPC filled with grout regardless of the strength difference of HPC and grout. However the strength was increased inversely corresponding to the hollow ratio. The structural capacity of HPC without grout closely related to the hollow size. Especially, the local collapse governs the overall failure when the thickness of HPC is too thin. Based on these effect, a suitable equation was suggested for calculation of the compressive strength of HPC column with or without grout. FE analysis considering the contact surface between HPC and grout produced a good result matched to the test result.

Evaluation of Timependent Creep and Shrinkage of CIP Section in Asymmetric PSC Box Girder for Railroad Bridge (철도교용 비대칭 거더의 현장 타설부에서 나타나는 시간에 따른 크립 및 건조수축 평가)

  • Jung, Chi-Young;Park, Seung-Min;Ahn, Jin-Hee;Kim, Sang-Hyo
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.973-978
    • /
    • 2011
  • In this study, effects due to differences of creep and shrinkage which is caused by material differences such as concrete characteristic and age in an asymmetric PSC box girder were evaluated. For this purpose the prestress distribution, creep and shrinkage were analyzed with the FE analysis program, LUSAS 14.3. As a result of the prestress, the stress distribution was stable. In case of the analysis result which was conducted with 1,000 days response time, the shear stress between PC section and CIP section is satisfied with design shear strength.

  • PDF

Fast Fabrication of Nanoporous Anodic Alumina Membrane by Hard Anodization (하드애노디제이션에 의한 나노다공질 양극산화 알루미나 멤브레인의 제조)

  • Ha, Yoon-Cheol;Jeong, Dae-Yeong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.429-429
    • /
    • 2009
  • Nanoporous anodic alumina membranes (NAAM) with high-density through-hole pores fabricated by hard anodization of aluminum in 0.3 M oxalic acid under the applied voltage of 40 (mild anodization), 80, 100, 120 and 140 V were investigated. The current-time responses monitored using a PC-controlled anodization cell and the corresponding pore structures attainable from field-enhanced scanning electron microscopy (FE-SEM) were analyzed in order to establish the optimum fabrication process. The nanoporous structure can be produced for all the voltage conditions, while the stabilized through-hole pore formation seems to occur at 40, 80 and 140 V. The growth rate under 140 V hard anodization was over 30 times higher than under 40 V mild anodization (1.5 um/hr).

  • PDF

The NMRD Profiles of Ultrasmall Superparamagnetic Iron Oxide: Computer Simulation

  • 장용민;황문정;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.107-107
    • /
    • 2001
  • 목적: 초상자성 nano-particle 조영제의 자기이완효과에 관한 out sphere 기전에 기초하여 각각의 자기장의 세기에서 T1/T2 자기이완율을 나타내는 NMRD profile을 수치적으로 simulation 하는 프로그램을 개발하고자 하였다. 대상 및 방법: 초상자성 nano-particle 조영제의 경우 초상자성 물질을 생체적합성 고분자로 표면 coating하기 때문에 상자성 조영제와는 달리 전적으로 "out sphere"기여도만을 고려하였고 또한 초상자성 물질의 경우 자기적 에너지의 크기가 매우 크기 때문에 상자성 조영제의 기전에서 사용되는 "low field"근사를 사용할 수 없으므로 Brillouin 함수로 표현되는 총자화에 대한 표현을 적용하였다. nano-particle내에 포함된 Fe 원자수에 따른 T1 및 T2 NMRD Profile과 온도에 따른 T1 및 T2 NMRD Profile 그리고 초상자성 nano-particle size에 따른 T1 및 T2 NMR Profile을 PC (CPU=800 Mhz, memory=128 MB) 환경하에서 symbolic computation tool 인 MathCad (MathCad, USA)를 사용하여 구현하였다.

  • PDF

Development and Performance of Automated Calibration System of Sound Level Meters (소음계 교정 자동화 시스템 개발 및 성능평가)

  • 김용태;조문재;이용봉;서재갑
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

On the Leakage Safety Analysis of $9\%$ Nickel Type LNG Storage Tank with Thermal Resistance Effects (열저항 효과를 고려한 $9\%$ 니켈강재식 LNG 저장탱크의 누설 안전성에 관한 연구)

  • Kim C.K.;Cho S.H.;Suh H.S.;Hong S.H.;Lee S.R.;Kim Y,G.;Kwon B.K.
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.1-8
    • /
    • 2005
  • In this study, the FE analysis has been presented for the leakage safety of $9\%$ nickel type LNG storage tank based on the thermal resistance effects between insulation panels, comer protection and prestressed concrete(PC) structures. The FEM calculated results show that the leakage safety of fiber glass blanket, perlite powder and cellular glass insulators does not guarantee any more due to a strength failure of the insulation structure. But the corner protection and PC structure of outer tank may delay or sustain the leaked LNG of 10 days even though the inner tank and insulation structure are simultaneously failed. This means that $9\%$ nickel steel type LNG storage tank may be safe because of a high strength of the corner protection and outer tank structures.

  • PDF

Application of Science for Interpreting Archaeological Materials(II) - Production and Flow of Lead Glass from Mireuksa Temple - (고고자료(考古資料)의 자연과학(自然科學) 응용(應用)(II) - 익산(益山) 미륵사지(彌勒寺址) 납유리(琉璃)의 제조(製造) 및 유통(流通) -)

  • Kang, Hyung-Tae;Kim, Seong-Bae;Huh, Woo-Young;Kim, Gyu-Ho
    • Korean Journal of Heritage: History & Science
    • /
    • v.36
    • /
    • pp.241-266
    • /
    • 2003
  • Glass pieces excavated from Mireuksa Temple dated $7^{th}$ century A.D. were characterized by chemical composition, specific gravity and melting point. Lead isotope ratios of lead glasses were also compared with those of lead ore to attribute which lead ore was delivered for making lead glass. It was known that some lead glasses found in Japan were similar with those of Mireuksa Temple as comparing the data of chemical composition and lead isotope ratios. Characteristics of lead glass from Mireuksa Temple Thirty five glass pieces of Mireuksa Temple were analyzed for five oxides and found that all was lead glass system(PbO-$SiO_2$) with the range of 70~79% for PbO and 20~28% for $SiO_2$. The concentrations of oxides such as $Al_2O_3$, $Fe_2O_3$ and CuO were below 0.4%, 0.3% and 0.9%, respectively. Principal component analysis(PCA) as a statistical method was carried out to classify glasses with the similarities of chemical concentrations. The result of PCA has shown that three groups of glasses were created according to the excavation positions and two major oxides(PbO and $SiO_2$) greatly contributed to the dispersion of glasses on principal component 1(PC1) axis and trace element oxides($Al_2O_3$ and $Fe_2O_3$) for PC2 axis. Most of lead glasses were greenish by the efficacy of iron and copper oxides and some showed yellowish-green. The gravity of lead glasses was about 4.4~5.4 and estimated melting point was near $670^{\circ}C$. Lead isotope ratios of glasses were analyzed and found quite close to a lead ore from the Bupyeong mine in Gyeonggi-do. Comparison with lead glasses found in Japan Lead glasses of Mireuksa Temple were compared with those of Japan on the basis of chemical and physical data. Chemical compositions of Japanese lead glasses dated $7^{th}{\sim}8^{th}$ century A.D. were nearly similar with those of Mireuksa Temple but lead isotope ratios of those were separated into two groups. Three distribution maps of lead ores of Korea, Japan and China with lead isotope ratios were applied for lead glasses found in Japan. The result have shown that the locations of lead glasses from Fukuoka Prefecture coincided with the region of northen part of Korea and similar with those of Mireuksa Temple and lead glasses from Nara Prefecture dated $8^{th}$ century A.D. were located in the region of Japanese lead ore. This research has demonstrated that lead glasses of Mireuksa Temple conveyed to Miyajidake site, Fukuoka Prefecture around $7^{th}$ century A.D. and glass melting pots and glass beads excavated from Nara Prefecture confirmed the first use of Japanese lead ore for production of lead glasses from the end of $7^{th}$ century A.D.

Optimal Design of Long-fiber Composite Cover Plate with Ribs (리브를 가진 장섬유 복합재료 커버 플레이트의 최적설계)

  • Han, Min-Gu;Bae, Ji-Hun;Lee, Sung-Woo;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.30 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • Carbon fiber reinforced composites have light weight and high mechanical properties. These materials are only applicable in limited shape structure cause by complex curing process and low drapability. To solve this problem, Long Fiber Prepreg Sheet (LFPS) has been proposed. In this research, electric device cover plate was selected and designed by using LFPS. Before the design process, we analyzed the target structure to which the rib structures were applied. And 8-inch tablet PC product was selected. For FE analysis, simple loading and boundary conditions were applied. Stiffness of rib structure was investigated according to the rib pattern and shape changes. Rib pattern and shape were selected based on fixed volume condition analysis results. And uneven rib width model was selected for the best case whose deflection was reduced 6~10% than uniform rib model.

Analysis of the Polymer Properties and Sound Characteristics of Interlayer Films for Laminated Glass (접합유리용 고분자 필름의 물성 및 음향학적 특성 분석)

  • Ko, Sangwon;Hong, Jiyoung;Sunwoo, Yerim;Kim, Young Jun
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • To improve the sound insulation performance of laminated glass in high speed trains, it is beneficial to study the relationship between the characteristics of interlayer films and the acoustical performance. In addition to those of conventional PVB (polyvinyl butyral), the dynamic mechanical properties of PVB derivatives and PC (polycarbonate), which are candidates for interlayer films, were analyzed. We assumed that PVB-HEMU, which has a glass transition temperature ($T_g$) around room temperature and a large tan ${\delta}$ (loss tangent) value, can be made to damp efficiently. The damping capability was tested utilizing sound transmission loss measurement and simulation under the identical structure of laminated glass in high speed trains. We also built a database for analysis of relations between interlayer film characteristics and acoustical performance; this was followed by the determination of sound transmission loss using the intensity technique and FEA.

THE BRIGHT PART OF THE LUMINOSITY FUNCTION FOR HALO STARS

  • Lee, Sang-Gak
    • Journal of The Korean Astronomical Society
    • /
    • v.28 no.2
    • /
    • pp.139-146
    • /
    • 1995
  • The bright part of the halo luminosity function is derived from a sample of the 233 NLTT propermotion stars, which are selected by the 220 km/ see of cutoff velocity in transverse to rid the contamination by the disk stars and corrected for the stars omitted in the sample by the selection criterion. It is limited to the absolute magnitude range of $M_v=4-8$, but is based on the largest sample of halo stars up to now. This luminosity function provides a number density of $2.3{\cdot}10^{-5}pc^{-3}$ and a mass density of $2.3{\cdot}10^{-5}M_{o}pc^{-3}$ for 4 < $M_v$ < 8 in the solar neighborhood. These are not sufficient for disk stability. The kinematics of the sample stars are < U > = - 7 km/sec, < V > = - 228 km/sec, and < W > = -8 km/sec with (${\sigma_u},{\sigma_v},{\sigma_w}$) = (192, 84, 94) km/sec. The average metallicity of them is [Fe/H] = $- 1.7{\pm}0.8$. These are typical values for halo stars which are selected by the high cutoff velocity. We reanalyze the luminosity function for a sample of 57 LHS proper-motion stars. The newly derived luminosity function is consistent with the one derived from the NLTT halo stars, but gives a somewhat smaller number density for the absolute magnitude range covered by the LF from NLTT stars. The luminosity function based on the LHS stars seems to have a dip in the magnitude range corresponding to the Wielen Dip, but it also seems to have some fluctuations due to a small number of sample stars.

  • PDF