• 제목/요약/키워드: Fe-GAC + GAC column

검색결과 4건 처리시간 0.017초

비소와 철 동시제거를 위한 Fe-GAC와 GAC로 충진된 컬럼 (Column filled with Fe-GAC and GAC to remove both As(V) and Fe(III))

  • 이용수;도시현;홍성호
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.87-97
    • /
    • 2016
  • First of all, Fe or/and Mn immobilized granular activated carbons (Fe-GAC, Mn-GAC, (Fe, Mn)-GAC) were synthesized and tested to remove arsenate (As(V)). The results in batch test indicated that Fe-GAC removed As(V) effectively, even though the surface area of Fe-GAC was reduced largely. Moreover, adsorption isotherm test indicated that the experimental data fit well with Langmuir model and the maximum adsorption capacity ($q_{max}$) of Fe-GAC for As(V) was $3.49mg\;g^{-1}$, which was higher than GAC ($2.24mg\;g^{-1}$). In column test, the simulated water, which consisted of As(V), Fe(III), Mn(II) and Ca(II) in tap water, was used. Fe-GAC column with 1 hr of pre-washing time treated As(V) effectively while GAC column removed Fe(III) better than Fe-GAC column. Moreover, the increasing pre-washing time from 1 to 9 hour in Fe-GAC column enhanced Fe(III) removal with little negative impact of As(V) removal. Mostly, the column filled with Fe-GAC and GAC (i.e. the mass ratio of Fe-GAC:GAC = 2:8) showed the higher treatability of both As(V) and Fe(III), even it operated with 1 hr pre-washing time.

철침착 입상활성탄(Fe-GAC)을 이용한 지하수 내 비소 제거기술 (Arsenic Removal Using Iron-impregnated Ganular Activated Carbon (Fe-GAC) of Groundwater)

  • 윤지영;고경석;유용재;전철민;김규범
    • 자원환경지질
    • /
    • 제43권6호
    • /
    • pp.589-601
    • /
    • 2010
  • 최근 들어 지질기원에 의해 발생되는 지하수내 비소오염이 많이 보고되고 있다. 본 연구에서는 지하수내 비소를 효과적으로 제거하거 위하여 철침착 입상활성탄(Fe-GAC)을 제조하고 이에 대한 흡착능을 평가하였다. Fe-GAC는 질산 염철 용액으로 입상활성탄에 철화합물을 침착시켜 제조하였으며, 이를 이용하여 침착반응시간에 따른 등온흡착, pH에 따른 비소 동력학 흡착반응 및 수처리시스템 예비평가를 위한 칼럼 실험을 수행하였다. 연구결과 침착반응 시간이 최소 12시간 이상에서 비소 제거에 필요한 철의 함량을 가진 Fe-GAC가 제조되었으며, 이들의 흡착능은 등온흡착실험에서도 확인되었다. 입상활성탄에 침착된 철화합물은 XRD 분석결과 대부분 질산염수산화철($Fe_4(OH)_{11}NO_3{\cdot}2H_20$)이었으나 일부 소량의 적철석($Fe_2O_3$)도 관찰되었다. 등온흡착실험은 Langmuir가 Freundlich 모델보다 더 적합하였으며, 모델링 결과 얻어진 Freundlich 분배계수($K_F$) 및 Langmuir 최대 흡착량($Q_m$)은 입상활성탄에 침착된 철 함량과 로그-로그 양의 상관관계를 보여주었다. 동력학 흡착실험 결과 pH 11을 제외한 모든 조건 (pH 4-9)에서 Fe-GAC는 비소에 대해 뛰어난 흡착능을 나타내었으며, 따라서 일반적인 지하수의 pH가 6-8 사이임을 고려하면 Fe-GAC는 비소를 흡착에 매우 효과적인 흡착제로 이용될 것이다. 동력학 모델링 결과 Fe-GAC와 비소의 흡착은 화학적 흡착(chemisorption) 과정을 나타내는 pseudo-second order 모델이 가장 적합하였다. 비소 수처리시스템에 대한 예비 평가를 위하여 칼럼실험을 수행한 결과, 지연계수 482.4이고 분배계수 581.1 L/mg으로 이는 12-24시간 침착반응에서 제조된 Fe-GAC의 Freundlich 등온흡착 모델의 분배계수(511.5-592.5 L/mg)와 유사한 값을 나타내었다. 이러한 연구결과는 향후 지하수를 활용하는 마을상수도 수처리시스템에서 Fe-GAC가 지하수의 비소를 제거하는 뛰어난 흡여재로 사용될 수 있음을 나타내는 것이다.

염화철(III)로 표면개질 활성탄을 이용한 비소제거 (Arsenic Removal using the Surface Modified Granular Activated Carbon treated with Ferric Chloride)

  • 박유리;홍성혁;김정환;박주양
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.77-85
    • /
    • 2012
  • The present study investigates treatment methods for removal of arsenic from wastewater. The granular activated carbon (GAC) with the coating of iron chloride ($FeCl_3$) was used for the treatment of a low concentration of arsenic from wastewater. Batch experiments were performed to investigate the synthesis of Fe-GAC (Iron coated granular activated carbon), effects of pH, adsorption kinetics and the Langmuir model. The synthesized Fe-GAC with 0.1 M $FeCl_3$ shows best removal efficiency. Adsorption studies were carried out in the optimum pH range of 4-6 for arsenic removal. The Fe-GAC showed promising results by removing 99.4% of arsenic. In the adsorption isotherm studies, the observed data fitted well with the Langmuir models. In continuous column study showed that As(V) could be removed to below 0.25 mg/L within 1,020 pore volume. Our results suggest that the surface modified granular activated carbon treated with $FeCl_3$ for effective removal of arsenic from wastewater.

입상활성탄을 이용한 인공 조제 지하수내의 Cr(VI) 제거와 그 활성탄의 재생 (Cr(VI) Removal from Artificial Groundwater by Granular Activated Carbon and Regeneration of the Spent Carbon)

  • Ihnsup Han
    • 한국토양환경학회지
    • /
    • 제4권2호
    • /
    • pp.11-31
    • /
    • 1999
  • 회분식 및 연속류 주상 실험을 통해 인공 조제 지하수로부터 입상활성탄에 의한 6가크롬 (Cr(VI)) 제거에 대한 연구를 수행하였다. 실험에 적용된 변수로는 용액의 pH, 용존산소의 존재여부를 사용하였고 2가철(Fe(II))로 활성탄을 전처리한 것을 처리하지 않은 활성탄과 그 결과를 비교하였다. 용액의 pH를 4.0에서 7.5로 증가 시킴에 따라 무처리 및 Fe(II)로 전처리한 활성탄 모두에 흡착된 Cr(VI)의 양이 현저히 감소하였다. 용존산소가 배제 (무산소조건) 되었을 경우 Cr(VI) 제기량이 증가하였는데, 이는 Cr(VI)의 Cr(III)로의 환원 때문으로 추측된다. 그러나, Fe(II)에 의한 활성탄의 전처기는 Cr(Vl)제거에 거의 영향을 미치지 않았다 흡착된 Cr(VI)를 추출하기위해 0.01M $K_2$$HPO_4$와 침전 또는 흡착된 Cr(III)를 제거하기위해 0.02N $K_2$$HPO_4$로 세척하였는데, 이는 Cr(VI)로 흡착능이 고갈된 활성탄 재생의 한 방법으로 고려될 수 있으리라 사료된다. 재생된 활성탄은 본래의 활성탄보다 큰 흡착능을 보였는데, 그 이유는 Cr(VI)가 낮은 pH에서 흡착이 잘되며 또 Cr(III)로 환원되기 때문으로 사료된다. 산세척수중의 Cr(III)의 존재는 비교적 산성 조건하에서 Cr(VI)의 Cr(III)로의 환원을 보여주는 증거로 사료된다. 5회의 재생 및 재사용 실험에서 이 재생방법이 흡착능을 악화시키는 것 없이 지속적으로 사용될 수 있음을 알 수 있었다.

  • PDF