• 제목/요약/키워드: Fault-prevention

검색결과 149건 처리시간 0.034초

전기 절연물의 오염에 따른 누설전류 특성 및 사고위험성 연구 (The Accident Hazard and Properties of the Leakage Current on the Electrical Insulation by Pollution)

  • 김영석;송길목;정진수;정종욱;김선구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.463-467
    • /
    • 2007
  • It is necessary to study the prevention and the management of electrical facilities because the electrical fault took place at the dust occurrence area due to environmental pollution. In particular, the dust accumulates easily on insulation material which is exposed an external long time. The leakage current brings out electrical fault after all. Also, it is need to variation of material and shape to repress a leakage current on electrical material. In this paper, we measured a leakage current on electrical material of facilities by dust, and in experiments the prevention to electrical fault was studied.

  • PDF

Fault Tree Analysis에 의한 Press 안전사고의 체계적 분석 (A Systems Approach to Press Injuries Using Fault Tree Analysis)

  • 이면우;윤조덕
    • 대한산업공학회지
    • /
    • 제6권2호
    • /
    • pp.1-11
    • /
    • 1980
  • The purpose of this study is to attempt a systems approach to press injuries using Fault Tree Analysis. Three major techniques were used: Industrial Accident Dynamics (IAD) by which accident analysis can be made, Fault Tree Analysis (FTA) by which quantification of accident analysis can be made, Computerized Algorithm by which minimal cut set to accident can be identified. A survey has been made of ninety two cases of press injuries from seven industrial firms. All cases of the accident are analyzed using the three techniques. According to the analysis, lack of safety knowledge and improper scaffold seem to be the primal cause of accident. Comparisons of the accident causes to actual accident reports (National Institute of Labor Science) demonstrates that the FTA is a powerful tool for industrial accident prevention. On the basis of this result, some countermeasures are discussed.

  • PDF

지능화 차량의 고장진단 로직 개발 (Model-Based Fault Detection and Failsafe Logic Development)

  • 민경찬;김정태;이건복;이경수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.774-779
    • /
    • 2004
  • This paper describes the fault detection and failsafe logic to be used in the Electronic Stability Program (ESP). The Aim of this paper is prevention of erroneous control in the ESP. This paper introduces the fault detection logic and evaluation of residual signals. Failsafe logic consist of four redundant sub-models and they can be used for the detection of faults in each sensor (yaw rate, lateral acceleration, steering wheel angle). We presents two mathematical residual generation method ; one is the method by the average value, and the other is the method by the minimum value of the each residual. We verify a failsafe logic using vehicle test results, also we compare vehicle model based simulation results with test vehicle results.

  • PDF

특징 추출과 검출 오차 최소화 알고리듬을 이용한 회전기계의 결함 진단 (Fault Diagnosis for Rotating Machine Using Feature Extraction and Minimum Detection Error Algorithm)

  • 정의필;조상진;이재열
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.27-33
    • /
    • 2006
  • Fault diagnosis and condition monitoring for rotating machines are important for efficiency and accident prevention. The process of fault diagnosis is to extract the feature of signals and to classify each state. Conventionally, fault diagnosis has been developed by combining signal processing techniques for spectral analysis and pattern recognition, however these methods are not able to diagnose correctly for certain rotating machines and some faulty phenomena. In this paper, we add a minimum detection error algorithm to the previous method to reduce detection error rate. Vibration signals of the induction motor are measured and divided into subband signals. Each subband signal is processed to obtain the RMS, standard deviation and the statistic data for constructing the feature extraction vectors. We make a study of the fault diagnosis system that the feature extraction vectors are applied to K-means clustering algorithm and minimum detection error algorithm.

Evaluation of the relationship between maximum tsunami heights and fault parameters in Korea

  • Song, Min-Jong;Kim, Chang Hee;Cho, Yong-Sik
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2022년도 학술발표회
    • /
    • pp.275-275
    • /
    • 2022
  • Tsunamis triggered by undersea earthquakes have the characteristic of longer wavelengths and can propagate a very long distance. Although the occurrence frequency of tsunami is low, it can cause casualties and properties. Historically, tsunamis that occurred on the western coast of Japan attacked the eastern coast of the Korean Peninsula and damaged the property and the loss of human life in 1983 and 1993. By tsunami in 1983 especially, 2 people were killed, and more than 200 casualties occurred. In addition, it caused 2 million dollars in property damage at Imwon Port. In 2011, The eastern cities of Japan: Iwate, Miyagi, Ibaraki, and Fukushima were damaged by a tsunami that occurred near onshore along the Pacific ocean and caused more than 300 billion dollars in property damage, and 20,000 casualties occurred. Moreover, those provoked nuclear power plant meltdown at Fukushima. In this study, it was carried out a relationship between maximum tsunami heights and fault parameters of earthquake: strike angle, dip angle, and slip angle at Imwon port. Those fault parameters are known that it does not relate to the magnitude of earthquake directly. Virtual tsunamis, which could be triggered by probable undersea earthquakes in the future, were investigated and mutual information based on probability and information theory was introduced to figure out the relationship between maximum tsunami height and fault parameters. Fault parameters were evaluated according to the strong relationship with maximum tsunami heights finally.

  • PDF

DC 급전케이블 지락사고 보호방안에 관한 연구 (The study on the prevention of DC feeder line cable grounding fault)

  • 박지수;송중호;박정욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.202-207
    • /
    • 2008
  • This study provides review and improvement plans for the possible problems caused when the CV cable is used as a positive feeder line which supplies power from the DC HSCB (high-speed circuit breaker) to the catenariesin Seoul Metro which is using direct-current feeder method. In detail, this study contributes to stabilizing the power line by triggering a protective device by instantly detecting potential rise which happens when grounding fault occurs in non-grounding type CV cable shield.

  • PDF

변전설비의 보수 정비 사례 및 고장 실태 조사 연구 (A case study on the prevention and occurrence of fault in Transmission & Substation)

  • 이석규;박희우;김인건;이종학;이만선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.83-85
    • /
    • 1999
  • Recently, a rapid increase of electricity demands have made Transmission & Substation device large-sized. complicated and diverse. Moreover, a rising level of customer's requirement and high growth of industry increase the reliability of electricity service. Therefore on the basis of the case study on the occurrence of fault, the prevention of defects for each device and the analyzing of the outbreak and prevention of systematic breakdown in Sin-Incheon Power Transmission Branch Office, this paper presents some important matters and suggests the method of improvement in design, construction, maintenance, and repairing the Transmission & Substation device.

  • PDF

사고전압 감지형 아크차단 제어회로 개발 (Development of Arc Fault Interruption Control Circuit of Fault Voltage Sensing Type)

  • 곽동걸;변재기;이봉섭
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.1-5
    • /
    • 2013
  • 본 논문은 사고전압 감지형의 아크차단 제어회로에 대한 연구로써, 전기사고 발생 시 선간전압의 순간적인 전압감쇠를 감지하여 기존 차단기를 동작시키는 전압감지형 전기화재 예방장치이다. 현재 저압배전 계통에 사용중인 누전차단기, 배선용차단기 그리고 RCD 등은 전기화재의 주요 요인인 아크사고에 대해 보호능력이 없는 것으로 분석된다. 본 논문에서는 이러한 문제점들을 개선하기위하여 이전의 전류감지에 의한 아크사고 차단방식이 아닌 사고발생 시 전압파형의 왜곡을 이용한 새로운 전압감지형 아크차단 제어회로를 개발하여 전기화재를 예방하고자 한다. 제안한 아크차단 제어회로는 소형 경량으로 제작되는 장점과 다양한 동작분석을 통하여 그 실용성을 검증하였다.

FDR를 위한 RDWT에 의한 주파수 추정 기법 (Frequency Estimation Method using Recursive Discrete Wavelet Transform for Fault Disturbance Recorder)

  • 박철원;반우현
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1492-1501
    • /
    • 2011
  • A wide-area protection intelligent technique has been used to improve a reliability in power systems and to prevent a blackout. Nowadays, voltage and current phasor estimation has been executed by GPS-based synchronized PMU, which has become an important way of wide-area blackout protection for the prevention of expending faults in power systems. As this technique has the difficulties in collecting and sharing of information, there have been used a FNET method for the wide-area intelligent protection. This technique is very useful for the prediction of the inception fault and for the prevention of fault propagation with accurate monitoring frequency and frequency deviation. It consists of FDRs and IMS. It is well known that FNET can detect the dynamic behavior of system and obtain the real-time frequency information. Therefore, FDRs must adopt a optimal frequency estimation method that is robust to noise and fault. In this paper, we present comparative studies for the frequency estimation method using IRDWT(improved recursive discrete wavelet transform), for the frequency estimation method using FRDWT(fast recursive discrete wavelet transform). we used the Republic of Korea 345kV power system modeling data by EMTP-RV. The user-defined arbitrary waveforms were used in order to evaluate the performance of the proposed two kinds of RDWT. Also, the frequency variation data in various range, both large range and small range, were used for simulation. The simulation results showed that the proposed frequency estimation technique using FRDWT can be the optimal frequency measurement method applied to FDRs.

원자력발전소의 물리적방호를 위한 핵심구역파악 규칙 개발 및 적용 (Vital Area Identification Rule Development and Its Application for the Physical Protection of Nuclear Power Plants)

  • 정우식;황미정;강민호
    • 한국안전학회지
    • /
    • 제32권3호
    • /
    • pp.160-171
    • /
    • 2017
  • US national research laboratories developed the first Vital Area Identification (VAI) method for the physical protection of nuclear power plants that is based on Event Tree Analysis (ETA) and Fault Tree Analysis (FTA) techniques in 1970s. Then, Korea Atomic Energy Research Institute proposed advanced VAI method that takes advantage of fire and flooding Probabilistic Safety Assessment (PSA) results. In this study, in order to minimize the burden and difficulty of VAI, (1) a set of streamlined VAI rules were developed, and (2) this set of rules was applied to PSA fault tree and event tree at the initial stage of VAI process. This new rule-based VAI method is explained, and its efficiency and correctness are demonstrated throughout this paper. This new rule-based VAI method drastically reduces problem size by (1) performing PSA event tree simplification by applying VAI rules to the PSA event tree, (2) calculating preliminary prevention sets with event tree headings, (3) converting the shortest preliminary prevention set into a sabotage fault tree, and (4) performing usual VAI procedure. Since this new rule-based VAI method drastically reduces VAI problem size, it provides very quick and economical VAI procedure. In spite of an extremely reduced sabotage fault tree, this method generates identical vital areas to those by traditional VAI method. It is strongly recommended that this new rule-based VAI method be applied to the physical protection of nuclear power plants and other complex safety-critical systems such as chemical and military systems.