• Title/Summary/Keyword: Fault tree analysis

Search Result 324, Processing Time 0.023 seconds

Bi-directional fault analysis of evaporator inspection system

  • Kang, Dae-Ki;Kang, Jeong-Jin
    • International journal of advanced smart convergence
    • /
    • v.1 no.1
    • /
    • pp.57-60
    • /
    • 2012
  • In this paper, we have performed a safety analysis on an automotive evaporator inspection system. We performed the bi-directional analysis on the manufacturing line. Software Fault Tree Analysis (SFTA) as backward analysis and Software Failure Modes, Effects, & Criticality Analysis (SFMECA) as forward analysis are performed alternately to detect potential cause-to-effect relations. The analysis results indicate the possibility of searching and summarizing fault patterns for future reusability.

A Systems Approach to Press Injuries Using Fault Tree Analysis (Fault Tree Analysis에 의한 Press 안전사고의 체계적 분석)

  • Lee, Myeon-U;Yun, Jo-Deok
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.6 no.2
    • /
    • pp.1-11
    • /
    • 1980
  • The purpose of this study is to attempt a systems approach to press injuries using Fault Tree Analysis. Three major techniques were used: Industrial Accident Dynamics (IAD) by which accident analysis can be made, Fault Tree Analysis (FTA) by which quantification of accident analysis can be made, Computerized Algorithm by which minimal cut set to accident can be identified. A survey has been made of ninety two cases of press injuries from seven industrial firms. All cases of the accident are analyzed using the three techniques. According to the analysis, lack of safety knowledge and improper scaffold seem to be the primal cause of accident. Comparisons of the accident causes to actual accident reports (National Institute of Labor Science) demonstrates that the FTA is a powerful tool for industrial accident prevention. On the basis of this result, some countermeasures are discussed.

  • PDF

Reliability Analysis Using Fault Tree (Fault Tree를 이용한 신뢰성 분석)

  • Lee, Chang-Hoon;Park, Soon-Dal
    • Journal of the military operations research society of Korea
    • /
    • v.6 no.1
    • /
    • pp.119-124
    • /
    • 1980
  • An efficient algorithm which can be employed in obtaining the minimal cut sets of a fault tree containing repeated events is introduced. A sample fault tree illustrates this algorithm. Efficiency of an algorithm is defined as the ratio of the number of minimal cut sets to the number of cut sets determined by the algorithm. An efficiency of the proposed algorithm is compared with those of two existing algorithms : Fussell and Vesely's algorithm and Bengiamin et al. 's algorithm. The proposed algorithm is shown to be more efficient than the existing two algorithms.

  • PDF

Diagnosis of Compressor Failure by Fault Tree Analysis (FTA기법을 이용한 콤프레서 고장진단)

  • 배용환;이석희;최진원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.127-138
    • /
    • 1994
  • The application of fault tree technique to the analysis of compressor failure is considered. The techniques involve the decomposition of the system into a form of fault tree where certain basic events lead to a specified top event which signifies the total failure of the system. In this paper, fault trees are made by using fault train of screw type air compressor failure. The fault trees are used to obtain minimal cut sets from the modes of system failure and, hence the system failure rate for the top event can be calculated. The method of constructing fault trees and the subsequent estimation of reliability of the system is illustrated through compressor failure. It is proved that FTA is efficient to investigate the compressor failure modes and diagnose system.

Simulation-Based Risk Analysis of Integrated Power System (시뮬레이션을 이용한 통합전력시스템의 위험도 분석)

  • Lee, Ji Young;Han, Young Jin;Yun, Won Young;Bin, Jae Goo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.42 no.2
    • /
    • pp.151-164
    • /
    • 2016
  • In this paper, we deal with a risk analysis for an IPS (Integrated power system) and propose a simulation model combining the fault tree and event tree in order to estimate the system availability and risk level, together. Firstly, the basic information such as operational scenarios, physical structure, safety systems is explained in order to make the fault tree and event tree of the IPS. Next, we propose a discrete-event simulation model using a next-event time advance technique to advance the simulation time. Also the state transition and activity diagrams are explained to represent the relationship between the objects. By numerical examples, the redundancy allocation is considered in order to decrease the risk level of the IPS.

A Study Fuzzy model for Risk Analysis of Uncertainly FTA(Fault Tree Analysis) (FTA(Fault Tree Analysis)에서 불확실한 위험분석을 위한 퍼지모형 연구)

  • 임총규;박주식;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.1
    • /
    • pp.37-47
    • /
    • 2002
  • Risk analysis is a formal deductive procedure for determining combinations of component failures and human errors that could result in the occurrence of specified undesired events at the system level. This method can be used to analyze the vast majority of industrial system reliability problems. This study deals with the application of knowledge-engineering and a methodology for the assessment & measurement of reliability, availability, maintainability, and safety of industrial systems using FTA(fault tree analysis), A fuzzy methodology for fault-tree evaluation seems to be an alternative solution to overcome the drawbacks of the conventional approach (insufficient Information concerning the relative frequencies of hazard events). To improve the quality of results, the membership functions must be approximated based on heuristic considerations, The purpose of this study is to describe the knowledge engineering approach, directed to integrate the various sources of knowledge involved in a FTA.

Development of uncertainly failure information for FFTA (FFTA(Fuzzy Fault Tree Analysis)에 의한 불확실한 고장정보 연구)

  • 정영득;박주식;김건호;강경식
    • Journal of the Korea Safety Management & Science
    • /
    • v.3 no.2
    • /
    • pp.113-121
    • /
    • 2001
  • Today, facilities are composed of many complex components or parts. Because of this characteristics, the frequency of failures is decreasing, but the strength of failures is increasing; therefore, the failure analysis about many complex components or parts was needed. In the former research about Fault Tree Analysis, failure data of similar facilities have been used for forecasting about target system or components, but in case that the system or components for forecasting failure is new or qualitative and quantitative data are given simultaneously, there are many difficulty in using Fault Tree Analysis with this incorrect failure data. Therefore, this paper deal with the Fault Tree Analysis method which be applied with Fuzzy theory in above case. In case that , therefore, if there is no the correct failure data, it is represented a system or components as qualitative variable. subsequently, it converted to the quantitative value using fuzzy theory, and the values used as the value for failure forecast.

  • PDF

The Condition and Safety Assessment using Fuzzy Fault Tree Analysis for Bridge System (퍼지결함수분석을 이용한 교량시스템의 상태 및 안전성 평가)

  • 이중빈;나기현;손용우;박주원
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.79-86
    • /
    • 1999
  • This paper aims to propose a method that helps maintenance engineers to evaluate the damage states of bridge systems by using a Fuzzy Fault Tree Analysis(FFTA). It may be stated that Fuzzy Fault Tree Analysis may be may useful for the systematic md rational condition and safety assessment for real bridge systems problems because the approach is able to effectively deal with all the related bridge system damages in terms of the linguistic variables that incorporate systematically experts experiences and subjective judgement.

  • PDF

Fuzzy Sets Application to System Reliability Analysis (시스템 신뢰도 분석에서의 퍼지집합 응용)

  • Yun, Won-Young;Heo, Gil-Hwan
    • IE interfaces
    • /
    • v.6 no.2
    • /
    • pp.67-78
    • /
    • 1993
  • In this paper, we deal with the application of the fuzzy sets theory to evaluate and estimate the system reliability under the fault tree analysis. We formulate the uncertainty of component reliability to fuzzy sets, and propose a procedure for obtaining the system reliability in case the system structure is described by fault tree. An importance measure of each component is proposed. Computer program for fuzzy fault tree analysis(FFTA) is developed using C language to obtain the system reliability and the component‘s fuzzy importance.

  • PDF

An Integrative Method of Fault Tree Analysis and Fault Modes and Effect Analysis for Security Evaluation of e-Teaching and Learning System (전자 교수학습 시스템의 보안성 평가를 위한 결함트리분석과 고장유형에 대한 영향분석의 통합적 방법)

  • Jin, Eun-Ji;Kim, Myong-Hee;Park, Man-Gon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.1
    • /
    • pp.7-18
    • /
    • 2013
  • These days, the teaching and learning system has been increasing for the rapid advancement of the information technologies. We can access education systems of good quality anytime, anywhere and we can use the individually personalized teaching and learning system depending on developing the wireless communication technology and the multimedia processing technology. The more the various systems develop, the more software security systems become important. There are a lot kind of fault analysis methods to evaluate software security systems. However, the only assessment method to evaluate software security system is not enough to analysis properly on account of the various types and characteristic of software systems by progressing information technology. Therefore, this paper proposes an integrative method of Fault Tree Analysis (FTA) and Fault Modes and Effect Analysis(FMEA) to evaluate the security of e-teaching and learning system as an illustration.