• Title/Summary/Keyword: Fault table

Search Result 68, Processing Time 0.03 seconds

Analysis of Geological Factors for Risk Assessment in Deep Rock Excavation in South Korea (한국의 대심도 암반 굴착 위험도 산정을 위한 인자 분석)

  • Ihm, Myeong Hyeok;Lee, Hana
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.211-220
    • /
    • 2021
  • Tunnel collapse often occurs during deep underground tunneling (> 40 m depth) in South Korea. Natural cavities as well as water supply pipes, sewer pipes, electric power cables, artificial cavities created by subway construction are complexly distributed in the artificial ground in the shallow depths of the urban area. For deep tunnel excavation, it is necessary to understand the properties of the ground which is characterized by porous elements and various geological structures, and their influence on the stability of the ground. This study analyzed geological factors for risk assessment in deep excavation in South Korea based on domestic and overseas case study. As a result, a total of 7 categories and 38 factors were derived. Factors with high weights were fault and fault clay, differential stress, rock type, groundwater and mud inrush, uniaxial compressive strength, cross-sectional area of tunnel, overburden thickness, karst and valley terrain, fold, limestone alternation, fluctuation of groundwater table, tunnel depth, dyke, RQD, joint characteristics, anisotropy, rockburst and so forth.

A Study on the Establishment of Preventive Measures for Electric Fires Using the 4M Technique (4M 기법을 활용한 전기화재 예방대책 수립 연구)

  • Oh, Teakhum;Park, Chanseok
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.23-29
    • /
    • 2021
  • The purpose of this study is to reduce the probability of occurrence of electric fires as a preemptive preventive measure, and to strengthen the capability of preventing electric fires by strengthening the cooperative function between electric fire-related departments and establishing a cooperative system. In this study, the general aspects of electric fires were identified by reviewing the literature such as ignition mechanisms of electric fires. And the major electrical fires that occurred in the last 10 years were classified into ignition factors (short circuit, overload/overcurrent, and earth leakage/ground fault) and ignition sources (wiring/wiring appliances, electrical equipment/household appliances). And the 4M technique was used to analyze the potential causes of ignition at the fire site and to suggest preventive measures. In the case In this study, out of 48 electrical fires in the past 10 years, 16 short-circuit fires, 3 overload/overcurrent fires, 3 short-circuit and earth fault fires, 16 fires in wiring/wiring appliances, and 10 fires in electrical equipment/home appliances classified as cases. And prevention measures were presented in terms of human, machine, media, and management by using the 4M technique. For the preemptive prevention of electric fires, strengthening the compulsory electrical safety inspection and making it mandatory to report when new or expanding electric facilities, charging a fee for electric safety inspection for detached houses and granting benefits subject to inspection completion, improvement of the electric safety voluntary inspection table and safety indications; It was suggested as a policy to organize and operate electrical safety inspection personnel in a two-person team (mixed), establish a close work cooperation system with related organizations, and strengthen electrical safety education and publicity.

A Development of a Robotic Switch Board System for Main Distributing Frames (주배선반용 로봇 스위치 보드 시스템의 개발)

  • Sung, Young-Whee;Chung, Hae;Yi, Soo-Yeong;Ahn, Hee-Wook
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.2
    • /
    • pp.155-162
    • /
    • 2009
  • A main distributing frame(MDF) is an interface unit that is used to connect office equipment cables in a telephone company to subscriber cables. Until now, there is no automated switching system for MDFs in Korea. Manual handling of an MDF has some drawbacks; It is time-consuming, very cumbersome, and expensive. It also makes maintenance hard. An automated main distributing frame system is proposed and commercialized in Japan. In that system, a robot gripper inserts connecting pins into the cross point holes of a matrix board, which reveals several disadvantages in the aspects of space, maintenance, fault tolerance, and economical efficiency. This paper describes a newly developed robotic switch board system for MDFs. In the developed system, switches are placed at the cross point of a matrix board. There is one robot in between two switch units, so one robot deals with two switch units. In the system, positioning the robot, opening and closing switches can be done by using only a pair of motors and a pair of solenoids. The newly developed system is compact in size, reduces cost, and shows high reliability.

  • PDF

A Study on the Design of DCT Module using Distributed Arithmetic Method

  • Yang Dong Hyun;Ku Dae Sung;Kim Phil Jung;Yon Jung Hyun;Kim Sang Duk;Hwang Jung Yeun;Jeong Rae Sung;Kim Jong Bin
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.636-639
    • /
    • 2004
  • In present, there are many methods such as DCT, Wavelet Transform, or Quantization -to the image compression field, but the basic image compression method have based on DCT. The representative thing of the efficient techniques for information compression is DCT method. It is more superior than other information conversion method. It is widely applied in digital signal processing field and MPEG and JPEG which are selected as basis algorithm for an image compression by the international standardization group. It is general that DCT is consisted of using multiplier with main arithmetic blocks having many arithmetic amounts. But, the use of multiplier requires many areas when hardware is embodied, and there is fault that the processing speed is low. In this paper, we designed the hardware module that could run high-speed operation using row-column separation calculation method and Chen algorithm by distributed arithmetic method using ROM table instead of multiplier for design DCT module of high speed.

  • PDF

The design and performance evaluation of a high-speed cell concentrator/distributor with a bypassing capability for interprocessor communication in ATM switching systems (ATM교환기의 프로세서간 통신을 위한 바이패싱 기능을 갖는 고속 셀 집속/분배 장치의 설계 및 성능평가)

  • 이민석;송광석;박동선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1323-1333
    • /
    • 1997
  • In this paper, we propose an efficient architecture for a high-speed cell concentrator/distributor(HCCD) in an ATM(Asynchronous Transfer Mode) switch and by analyzeing the simulation results evaluate the performance of the proposed architecuture. The proposed HCCD distributes cells from a switch link to local processors, or concentrates cells from local processor s to a switch link. This design is to guarntee a high throughput for the IPC (inter-processor communication) link in a distributed ATM switching system. The HCCD is designed in a moudlar architecture to provide the extensibility and the flexibility. The main characteristics of the HCCD are 1) Adaption of a local CPU in HCCD for improving flexibility of the system, 2) A cell-baced statistical multiplexing function for efficient multiplexing, 3) A cell distribution function based on VPI(Virtual Path Identifier), 4) A bypassing capability for IPC between processor attached to the same HCCD, 5) A multicasting capability for point-to-multipoint communication, 6) A VPI table updating function for the efficient management of links, 7) A self-testing function for detecting system fault.

  • PDF

Development of On-line Performance Diagnostic Program of a Helicopter Turboshaft Engine

  • Kong, Chang-Duk;Koo, Young-Ju;Kho, Seong-Hee;Ryu, Hye-Ok
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.10 no.2
    • /
    • pp.34-42
    • /
    • 2009
  • Gas turbine performance diagnostics is a method for detecting, isolating and quantifying faults in gas turbine gas path components. On-line precise fault diagnosis can promote greatly reliability and availability of gas turbine in real time operation. This work proposes a GUI-type on-line diagnostic program using SIMULINK and Fuzzy-Neuro algorithms for a helicopter turboshaft engine. During development of the diagnostic program, a look-up table type base performance module are used for reducing computer calculating time and a signal generation module for simulating real time performance data. This program is composed of the on-line condition monitoring program to monitor on-line measuring performance condition, the fuzzy inference system to isolate the faults from measuring data and the neural network to quantify the isolated faults. Evaluation of the proposed on-line diagnostic program is performed through application to the helicopter engine health monitoring.

Modeling of Fine Cracks using Fuzzy Mathematical Morphology (퍼지 수학적 형태학을 이용한 미세균열 모델링)

  • Park, In-Kyoo;Choi, Gyoo-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.105-111
    • /
    • 2010
  • In this paper the elasticity of fault-detection algorithm based on fuzzy logic is proposed through lots of experiments, justifying its validity. The four mathematical morpholgical operators was defined to detect the cracks. The cracks was detected via center of area method with ${\lambda}$-fuzzy measure of fuzzy sets. However generally favorable, the result owes to how adequate the lighting device is designed in case of the so far fine crack of pieces. In an attempt to improve the response of the system, It is designed to minimize the use of memory via LookUp table in software.

Reducing Outgoing Traffic of Proxy Cache by Using Client-Cluster

  • Kim Kyung-Baek;Park Dae-Yeon
    • Journal of Communications and Networks
    • /
    • v.8 no.3
    • /
    • pp.330-338
    • /
    • 2006
  • Many web cache systems and policies concerning them have been proposed. These studies, however, consider large objects less useful than small objects in terms of performance, and evict them as soon as possible. Even if this approach increases the hit rate, the byte hit rate decreases and the connections occurring over congested links to outside networks waste more bandwidth in obtaining large objects. This paper puts forth a client-cluster approach for improving the web cache system. The client-cluster is composed of the residual resources of clients and utilizes them as exclusive storage for large objects. This proposed system achieves not only a high hit rate but also a high byte hit rate, while reducing outgoing traffic. The distributed hash table (DHT) based peer-to-peer lookup protocol is utilized to manage the client-cluster. With the natural characteristics of this protocol, the proposed system with the client-cluster is self-organizing, fault-tolerant, well-balanced, and scalable. Additionally, the large objects are managed with an index based allocation method, which balances the loads of all clients well. The performance of the cache system is examined via a trace driven simulation and an effective enhancement of the proxy cache performance is demonstrated.

A Study on the Imfluence of the Pipe Line of Boiler for Flame Distribution of Combustion Furnace (연소로의 화염분포가 보일러 관로에 미치는 영향에 관한 연구)

  • Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1435-1441
    • /
    • 2014
  • The fire took place in the synthetic heat transfer fluid boiler used in production process of medium density fiberboard. This study investigated pressure distribution of the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner. Pressure distribution at steady state in combustion furnace is 2~5mAq and pressure distribution at inverter under fault condition in combustion furnace is 10~-53mAq. The decrement of coil thickness measurement for synthetic heat transfer fluid boiler is 0~5mm.

A Study on FMEA Analysis Method for Fault Diagnosis and Predictive Maintenance of the Railway Systems (철도시스템 이상진단 및 예지정비를 위한 FMEA 분석 방안 연구)

  • Wang Seok Oh;Kyeong Hwa Kim;Jaehoon Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.43-50
    • /
    • 2023
  • With the advent of industrialization, consumers and end-users demand more reliable products. Meeting these demands requires a comprehensive approach, involving tasks such as market information collection, planning, reliable raw material procurement, accurate reliability design, and prediction, including various reliability tests. Moreover, this encompasses aspects like reliability management during manufacturing, operational maintenance, and systematic failure information collection, interpretation, and feedback. Improving product reliability requires prioritizing it from the initial development stage. Failure mode and effect analysis (FMEA) is a widely used method to increase product reliability. In this study, we reanalyzed using the FMEA method and proposed an improved method. Domestic railways lack an accurate measurement method or system for maintenance, so maintenance decisions rely on the opinions of experienced personnel, based on their experience with past faults. However, the current selection method is flawed as it relies on human experience and memory capacity, which are limited and ineffective. Therefore, in this study, we further specify qualitative contents to systematically accumulate failure modes based on the Failure Modes Table and create a standardized form based on the Master FMEA form to newly systematize it.